SEARCH · Engineering Papers
Results for “QC”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
AAF_UHSAS-air_CACTI
The UHSAS-air is the bench version of the UHSAS that measures particle size from 0.06 to 1.0 micro-meters. Aerosol passes through a laser beam and the resulting intensity of scattered light is directly correlated to the diameter of the particle passing through the beam. This isntrument has been modified to volumetricaly control the Sheath Flow using an Alicat flow controller. Data is reported at 1.000s and missing data is reported as -9999 Multiple data flags are present in this version. Counts?: The coincident error is deemed minimal until the counts exceed 4000. Counts between 3000 and 4000 are flagged with a caution flag (1). After 4000 counts a bad flag (2) is triggered and the data should not be used. Noise?: Instrument noise detected in 65-75nm size range. 1: Caution slight noise observed. 2: High amount of noise observed data should not be used. Total? Sum of all the flags triggered Max Flag: Max flag triggered by the above QC test CloudFlag: Warns of the presence of a cloud. Clouds can cause shattering on the probe and result in questionable measurements. Data during these periods of thin clouds (1) or heavy clouds (2) should be used with extreme caution.
Shortwave Spectrometer (SWS) zenith radiance swsrad.b1 v3 and higher
Hyperspectral zenith radiances from the SWS instrument reported at 1 Hz. This data stream contains calibrated, dark-subtracted, radiances from two grating array spectrometers: a Si-detector based spectrometer denoted by SW and an InGaAs based detector denoted by LW. Spectra from both spectrometers are calibrated based on the spectral responsivity determined by reference against NIST-traceable light sources are reported independently as separate arrays having the same time record but wavelength dimension specified for each detector. Because the LW spectrometer is more susceptible to temperature-induced changes, a scale factor adjustment is applied the the LW spectra to yield agreement with the SW spectra over the wavelength range where they overlap. The final radiances incorporate QC to flag saturated values, periods where house-keeping fields fall outside acceptable bounds, and to flag pixels for which the spectral responsivity is not acceptable.
ARM Aerial Facility (AAF) - Unmanned Aircraft Systems, Air temperature, Relative humidity
Data collected from aircraft, with lat/log/alt, and some qc
TROPoe retrievals from SGP C1
The TROPoe (formerly called AERIoe) algorithm (Turner and Löhnert 2014, 2021; Turner and Blumberg 2019) retrieves profiles of temperature and water vapor mixing ratio, together with cloud properties for a single-layer cloud (i.e., LWP, effective radius), from AERI-observed infrared radiance spectrum. The data can be used to characterize the evolution of the planetary boundary layer and boundary layer clouds. This data set was collected at the ARM SGP Central Facility (CF) during and after the MicroPulse DIAL Demonstration (MPDDEMO) field campaign. The TROPoe retrieval was run at 5-minute resolution, but retrievals can be performed at the maximum temporal resolution of the AERI instrument (order 30 s) -- if this higher temporal resolution is desired, please contact Dave Turner. This is a physical-iterative retrieval method. The retrieval of thermodynamic profiles from spectral infrared radiance observations is an ill-posed problem, and thus constraints need to be included in the retrieval algorithm to provide physically plausible results. Here, we use a climatology of radiosonde profiles collected at the ARM SGP site during the summer as our prior information in an optimal estimation framework. Surface meteorology and output from the rapid-refresh (RAP) numerical weather prediction model (above 4 km) were used as additional constraints by the retrieval. As the method uses an optimal estimation framework, a full error covariance matrix of each solution is included in the output file. The 1-sigma uncertainty of each retrieved variable, which is derived from the error covariance matrix, is included for each scientific field and is named "sigma_X", where "X" is the name of the scientific field (e.g., 'temperature'). The information content in the AERI observations, which is in the "dfs" field, on the thermodynamic profiles is primarily concentrated in the lowest 3 km or up to cloud base; the retrieved data should not be used above that level (or used with caution). There is an overall "qc_flag" field that is set when a retrieval should not be trusted. However, the logic that sets this flag did not work correctly, and it should not be used. Instead, consider all retrievals that have a value for "converged_flag" greater than 0 as valid. If you have any questions, contact Dave Turner. This is Release_2_12 of the TROPoe algorithm.
MARCUS ARM CN and CCN data reprocessed to remove ship exhaust influence
The data presented in this collection are the cloud condensation nuclei (CCN) and condensation nuclei (CN) from the MARCUS (Measurements of Aerosols, Radiation and CloUds over the Southern Oceans) campaign. This campaign involved the deployment of the ARM Mobile Facility aboard the RSV Aurora Australis between October 2017 and March 2018 during its summer season resupplying Australia’s Antarctic research stations from its port in Hobart, Australia. Routine processing undertaken by ARM does not remove platform exhaust associated with its deployment aboard ships. Consequently, the raw data were obtained and manually filtered to remove the influence of platform exhaust on the measurements by reviewing CCN, CN and BC data simultaneously and flagging all affected periods. Remaining data were then quality controlled for when instrument parameters were out of specification. CCN data are split into different streams for supersaturation settings before statistics for each hour being calculated. All data files contain NaN values for periods when data was removed for QC or exhaust reasons. Original raw data available at: Kulkarni, G. R., Flynn, C. and Koontz, A.: Atmospheric Radiation Measurement (ARM) user facility. 2017, updated hourly. Cloud Condensation Nuclei Particle Counter (AOSCCN100). 2017-10-29 to 2018-03-24, ARM Mobile Facility (MAR) Hobart, AUS to Antarctic Coast - resupply ship Aurora Australis; AMF2 (M1)., Atmospheric Radiation Measurement (ARM) user facility Data Center: Oak Ridge, Tennessee, USA [online] Available from: http://dx.doi.org/10.5439/1227964 (Accessed 9 November 2018), 2018. Kuang, C., Salwen, C., Boyer, M. and Singh, A.: Atmospheric Radiation Measurement (ARM) user facility. 2017, updated hourly. Condensation Particle Counter (AOSCPCF). 2017-10-29 to 2018-03-26, ARM Mobile Facility (MAR) Hobart, AUS to Antarctic Coast - resupply ship Aurora Australis; AMF2 (M1)., Atmospheric Radiation Measurement (ARM) user facility Data Center: Oak Ridge, Tennessee, USA [online] Available from: http://dx.doi.org/10.5439/1046184 (Accessed 9 November 2018), 2018.
NCSU Flux Tower Data
NCSU Flux Tower Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument descripotion Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Sonic Anemometer, 3 Condensation Particle Counters, 1 SP2, 1 POPS Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU flux tower was located next to the AMF sampling pad. The flux tower consisted of a 10 m telescoping tower. Mounted at the top of the tower was a sonic anemometer (RM Young 8000) and a Krypton Hygrometer. A sample line (¼” conductive tubing) and communication line was laid to a trailer located underneath and slightly adjacent to the tower. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts. Also sampling was a printed particle optical spectrometer (POPS) and a single particle soot photometer (SP2). Please contact mdpetter@ncsu.edu for further information.
NCSU RDMA data
NCSU RDMA Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Nano-Scanning Mobility Particle (SMPS); A Radial Differential Mobility Analyzer (RDMA) coupled with 1 Condensation Particle Counter Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU RDMA was operated at a sheath-to-sample flow ratio of 5:1.5 L min−1. The RDMA was configured to scan from 5 to 55 nm. It was located into the temperature-controlled trailer adjacent to the NCSU Flux Tower to observe size distributions of the aerosols.The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. Please contact mdpetter@ncsu.edu for further information.
NCSU HTDMA data
NCSU HTDMA data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Humidified Tandem Differential Mobility Analyzer; 2 Differential Mobility Analyzers (DMA1 and DMA2). Start Date: 2022-06-01 End Date: 2022-09-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU HTDMA was operated at a sheath-to-sample flow ratio of 5:1 L min−1. The HTDMA was configured to measure hygroscopic growth factors of dry particles with mobility diameters of D = 15, 20, 30, 40, and 50 nm at RH ~ 70%. A complete cycle for all diameters took ~30 minutes. A sample line brought aerosol inside the trailer at 2.5 L min-1, where it was distributed between NCSU RDMA (1.5 L min-1) and NCSU HTDMA (1 L min-1) lines. The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. The sample line entered DMA1 (operated as an electrostatic classifier). Monodisperse particles with certain fractions were humidified with temperature controlled Nafion membrane immersed in water before entering DMA2 (operated in scanning mobility particle sizer). Please contact mdpetter@ncsu.edu for further information.
NCSU Black Carbon (SP2) Data
NCSU SP2 Data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Single Particle Soot Photometer (SP2) Start Date: 2022-06-01 End Date: 2022-09-27 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The SP2 was located in the temperature-controlled trailer adjacent to the NCSU Flux Tower to observe refractory black carbon (rBC) number concentration and mixing states of black carbon. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts, a printed particle optical spectrometer (POPS), and SP2. Please contact mdpetter@ncsu.edu for further information.
ARM Aerial Facility (AAF) Dew Point Temperature from Gust Probe Sensor, Corrected and Merged with Nav Data
Merges the aafdewpoint.a1 data with aafnav.b1 data to make an aafdewpoint.b1 datastream that has only data in flight. Applies standard QC, as well.
EPCAPE-PT-LANL Measurements: Condensation Particle Counter
Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Condensational particle counter 3070 (TSI) Calibration: No calibration during the campaign. Files: data_10sec_CPC.csv, data_10min_CPC.csv Header: - NumberConcentration[/cm3]: Number concentration of aerosol particles measured by the CPC, expressed in particles per cubic centimeter. - NumberConcentration[/cm3]_QC: Number concentration of aerosol particles after quality control adjustments or filtering, expressed in particles per cubic centimeter. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement is flagged for quality control checks, (0=pass) - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement
A single fracture toughness parameter for fibrous composite laminates
A general fracture toughness parameter Qc was previously derived and verified to be a material constant, independent of layup, for centrally cracked boron aluminum composite specimens. The specimens were made with various proportions of 0 and + or - 45 degree plies. A limited amount of data indicated that the ratio Qc/epsilon tuf' where epsilon tuf is the ultimate tensile strain of the fibers, might be a constant for all composite laminates, regardless of material and layup. In that case, a single value of Qc/epsilon tuf could be used to predict the fracture toughness of all fibrous composite laminates from only the elastic constants and epsilon tuf. Values of Qc/epsilon tuf were calculated for centrally cracked specimens made from graphite/polyimide, graphite/epoxy, E glass/epoxy, boron/epoxy, and S glass graphite/epoxy materials with numerous layups. Within ordinary scatter, the data indicate that Qc/epsilon tuf is a constant for all laminates that did not split extensively at the crack tips or have other deviate failure modes.
Maximum likelihood estimates of polar motion parameters
Two estimators developed by Jeffreys (1940, 1968) are described and used in conjunction with polar-motion data to determine the frequency (Fc) and quality factor (Qc) of the Chandler wobble. Data are taken from a monthly polar-motion series, satellite laser-ranging results, and optical astrometry and intercompared for use via interpolation techniques. Maximum likelihood arguments were employed to develop the estimators, and the assumption that polar motion relates to a Gaussian random process is assessed in terms of the accuracies of the estimators. The present results agree with those from Jeffreys' earlier study but are inconsistent with the later estimator; a Monte Carlo evaluation of the estimators confirms that the 1968 method is more accurate. The later estimator method shows good performance because the Fourier coefficients derived from the data have signal/noise levels that are superior to those for an individual datum. The method is shown to be valuable for general spectral-analysis problems in which isolated peaks must be analyzed from noisy data.