Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Polymer derived Nicalon/Si-C-O composites - Processing and mechanical behavior

Ceramic matrix composites fabricated using Nicalon fiber and several polysilsesquioxane-derived Si-C-O matrices were characterized by optical and SEM and in four-point bending. In the matrix material linear shrinkages of up to 19 percent were observed for the vinylmethyl copolymer pyrolyzed to 1200 C, and up to 13 percent for the phenylmethyl material pyrolyzed to the same temperature, resulting in considerable matrix cracking. Under four-point loading, most composite samples fractured in a brittle manner as the result of strong fiber-matrix bonding. Flexural strengths, moduli, and ultimate strain varied with fiber sizing and processing parameters. Testing and analysis is being applied to promote more fibrous pullout during fracture.

Hurwitz, Frances I.↗

Mineralogy of three slightly palagonitized basaltic tephra samples from the summit of Mauna Kea, Hawaii

The paper characterizes the mineralogy and spectral properties of three slightly palagonitized basaltic tephra samples collected near the summit of Mauna Kea in order to contribute to the basis for inferring mineralogy and processes for Martian surface materials. The mineralogy of size fractions of these samples is examined by diffuse reflectance and FIR spectroscopy, optical microscopy, X-ray diffraction, Moessbauer spectroscopy, magnetic analysis, EMPA, TEM, and SEM. For the 20-1000 micron size fraction, sample HWMK11 (red) is essentially completely oxidized and has a hematite (Ti-hematite) pigment dispersed throughout the silicate matrix. Sample HWMK12 (black) has the lowest proportion of ferric-bearing phases and is thus least weathered. For HWMK11, the amount of hematite is essentially constant, and mica is present only in the coarse clay-sized fraction; smectites are low in structural Fe.

Golden, D. C.↗

Sensory characterization of a ready-to-eat sweetpotato breakfast cereal by descriptive analysis

The sweetpotato [Ipomoea batatas (L.) Lam], an important industry in the United States, has been selected as a candidate crop to be grown on future long-duration space missions by NASA. Raw sweetpotato roots were processed into flour, which was used to formulate ready-to-eat breakfast cereal (RTEBC). Twelve trained panelists evaluated the sensory attributes of the extruded RTEBC using descriptive analysis. The samples were significantly different (P<0.05) for all attributes. Twelve perceived sensory attributes, which could be used to differentiate the appearance, texture, and flavor of sweetpotato RTEBC, were described. The data could be used to optimize the RTEBC and for designing studies to test its consumer acceptance.

NASA Discipline Life Support Systems↗

Accounting for Uncertainties in Strengths of SiC MEMS Parts

A methodology has been devised for accounting for uncertainties in the strengths of silicon carbide structural components of microelectromechanical systems (MEMS). The methodology enables prediction of the probabilistic strengths of complexly shaped MEMS parts using data from tests of simple specimens. This methodology is intended to serve as a part of a rational basis for designing SiC MEMS, supplementing methodologies that have been borrowed from the art of designing macroscopic brittle material structures. The need for this or a similar methodology arises as a consequence of the fundamental nature of MEMS and the brittle silicon-based materials of which they are typically fabricated. When tested to fracture, MEMS and structural components thereof show wide part-to-part scatter in strength. The methodology involves the use of the Ceramics Analysis and Reliability Evaluation of Structures Life (CARES/Life) software in conjunction with the ANSYS Probabilistic Design System (PDS) software to simulate or predict the strength responses of brittle material components while simultaneously accounting for the effects of variability of geometrical features on the strength responses. As such, the methodology involves the use of an extended version of the ANSYS/CARES/PDS software system described in Probabilistic Prediction of Lifetimes of Ceramic Parts (LEW-17682-1/4-1), Software Tech Briefs supplement to NASA Tech Briefs, Vol. 30, No. 9 (September 2006), page 10. The ANSYS PDS software enables the ANSYS finite-element-analysis program to account for uncertainty in the design-and analysis process. The ANSYS PDS software accounts for uncertainty in material properties, dimensions, and loading by assigning probabilistic distributions to user-specified model parameters and performing simulations using various sampling techniques.

Nemeth, Noel↗

Microbes Share Rides Too: Updating Encapsulated Bioburden Estimate Values in Electronic Parts Common to Class D Mission Platforms.

As NASA develops more planetary protection missions that are Category III and in the Class D/rideshare mission platform, there is an increasing reliance on estimation of prelaunch bioburden to understand needs for burn up and breakup analyses or other methods to meet pre-launch bioburden levels. Current levels estimated for the encapsulated bioburden of semiconductor parts cited by NASA have been based on estimates of semiconductor manufacturing approaches from the 1970s that do not incorporate over fifty years of evolving cleanliness of semiconductor manufacturing processes and facilities. This investigation will focus on direct sampling of semiconductor parts for encapsulated bioburden values, drawing upon Goddard’s strength in EEE parts, supply chain management, destructive parts analysis and existing local planetary protection lab facilities to prepare and measure encapsulated bioburden at a statistically significant level for standard electronics parts common to known Class D/rideshare platforms.

planetary protection↗

Development of Gas Analysis Capabilities

Project Description: The project objective was to develop gas analysis methodology and processes to identify and quantify contaminants specific to KSC, primarily volatile organic compounds (VOCs), utilizing the recently purchased gas chromatograph-mass spectrometer (GCMS) coupled with a sample pre-concentrator. This work established a standing, quick-turnaround quantitative GCMS methodology for KSC-specific VOCs associated with launching and landing spacecraft at trace-levels far below previous detection limits. Closeout Summary: This project established a standing methodology for rapid turnaround identification and quantification of 119 targeted VOCs considered most likely to be encountered at KSC. Of these, 111 of the calibration files are based on manufacturer-certified gas standard mixes. The other eight were generated using standards generated in-house from neat, certified reference materials using procedures for standard generation that were developed under this project. Additionally, the spectral signatures of two hydrofluorocarbon precision cleaning solvents, that are widely used in flight hardware processing, have been added to the mass spectral library for rapid qualitative identification.

Cristina Oropeza↗

Noble Gases in Samples Returned From Asteroids Ryugu and Bennu

Introduction: The asteroid sample return missions, JAXA’s Hayabusa2 [1] and NASA’s OSIRIS-REx [2], fromC-rich asteroids Ryugu and Bennu offer unique opportunities to sample pristine early solar system material, unaffected by terrestrial weathering and contamination, and with a known geological context. The comparison with most primi-tive members of carbonaceous –and inner solar system ordinary and enstatite– chondrite classes allows us to (i) assess the variation (or the lack of thereof) of the distribution of the most volatile elements throughout the entire early solar system, (ii) determine the effects of parent body thermal and aqueous alteration, and (iii) learn about the dynamic evolution and history of the various parent bodies, as sampled by both return missions and meteorite delivery. Here we will present noble gas data obtained from newly received particles from Ryugu and Bennu. Samples & Analysis: We received nine particles allocated by JAXA, with masses of 0.5-1.7 mg mass: four col-lected during Hayabusa2’s first touchdown (chamber A) and five from a small artificial crater (chamber C). We received three particles from Bennu of 0.07, 0.89 and 0.94 mg mass (OREX-800032-102/3/4). All particles were processed, allocated, weighed, and transferred into our UHV sample chamber within pure N2, to prevent any contact with air. We examined all He-Xe isotopes with our custom-built mass spectrometer “Albatros” ([3,4]). Gases were extracted individually from each particle by melting induced by a 1064 μm Nd:YAG IR laser in 2–4 heating steps. Large amounts of water and other reactive volatiles were released, consistent with the presence of abundant volatiles from both Ryugu and Bennu. Residues of Ryugu particles remaining after lasering, subsequently exposed to air, were additionally extracted in a crucible to verify complete gas extraction. Only the particle that still showed a “crystalline” structure after lasering contained detectable Ryugu noble gases, whereas all other particles turned immediately into glassy spheres by laser heating and lacked any gas. Results & Discussion: Ryugu and Bennu matter contains noble gases similar to the most pristine, unheated aqueously altered meteorites, e.g., CM or CI chondrites [5,6]. Remarkably, all four chamber A samples that originated from Ryugu’s surface show solar wind (SW) Ne (trapped (20Ne/22Ne)tr ~12–13), whereas all five chamber C samples do not ((20Ne/22Ne)tr ~9.0–10.7 consistent with the presence of non-solar trapped Ne components such as Q and HL). This demonstrates that JAXA’s sampling strategy succeeded: Chamber C samples analyzed in this work originated from areas shielded from SW, slightly below the surface, that was sampled after the impactor excavated material. The three Bennu particles populate the same range as the Ryugu particles in Ne isotope space with one particle containing SW suggesting that it was part of the uppermost surface layer of Bennu during sampling, while Ne in the smallest sample can be explained best by mixing Ne from presolar diamonds and SiC or graphite, and that in the third one by mixing of, e.g., Q and HL. Using cosmic ray production rates given by [7] yields preliminary exposure ages for Ryugu particles in the same range as determined in [7]. There is, as expected, also no systematic difference between samples from chambers A and C because both sample sets were likely collected within the uppermost layer of Ryugu, which were not shielded from cosmic rays. The concentration of cosmogenic (cos) Ne in the Bennu particle, where Necos was resolvable, is in the same range as found for Ryugu, suggesting roughly similar exposure time to cosmic rays for 5–8 Ma for all particles examined here. The Xe isotopic compositions of all particles are consistent with those of phase Q, with small additions of Xe-HL from presolar diamonds and excess 129Xe* from short-lived 129I decay. The comparably high 129Xe*/129XeQ ratio is similar in all samples, suggesting similar initial I concentrations and closure to Xe loss –or the incorporation of a well-mixed Xe reservoir. The Bennu material was in brief contact with air in the capsule, after atmospheric entry and before storage in pure N2 in a clean room. Both, the –most diagnostic– Xe isotopes and the Ar/Xe vs. Kr/Xe systematics prove that the noble gases are not affected by terrestrial contamination, in contrast to many CI, CY, and CM chondrites found on Earth [5,6], illustrating the importance of sample return. He-Xe concentrations in all particles unaffected bySW are comparable to but at the upper end of ranges reported [5-7]. In accordance with the strong aqueous alteration experienced on the parent bodies of Ryugu and Bennu [1,2], all samples lack the Ar-rich and water-susceptible noble gas components found in less aqueously altered CMs or CRs [e.g., 5,8] and all COs.

Henner Busemann↗

Lunar and Planetary Science XXXV: Missions and Instruments: Hopes and Hope Fulfilled

The titles in this section include: 1) Mars Global Surveyor Mars Orbiter Camera in the Extended Mission: The MOC Toolkit; 2) Mars Odyssey THEMIS-VIS Calibration; 3) Early Science Operations and Results from the ESA Mars Express Mission: Focus on Imaging and Spectral Mapping; 4) The Mars Express/NASA Project at JPL; 5) Beagle 2: Mission to Mars - Current Status; 6) The Beagle 2 Microscope; 7) Mars Environmental Chamber for Dynamic Dust Deposition and Statics Analysis; 8) Locating Targets for CRISM Based on Surface Morphology and Interpretation of THEMIS Data; 9) The Phoenix Mission to Mars; 10) First Studies of Possible Landing Sites for the Phoenix Mars Scout Mission Using the BMST; 11) The 2009 Mars Telecommunications Orbiter; 12) The Aurora Exploration Program - The ExoMars Mission; 13) Electron-induced Luminescence and X-Ray Spectrometer (ELXS) System Development; 14) Remote-Raman and Micro-Raman Studies of Solid CO2, CH4, Gas Hydrates and Ice; 15) The Compact Microimaging Spectrometer (CMIS): A New Tool for In-Situ Planetary Science; 16) Preliminary Results of a New Type of Surface Property Measurement Ideal for a Future Mars Rover Mission; 17) Electrodynamic Dust Shield for Solar Panels on Mars; 18) Sensor Web for Spatio-Temporal Monitoring of a Hydrological Environment; 19) Field Testing of an In-Situ Neutron Spectrometer for Planetary Exploration: First Results; 20) A Miniature Solid-State Spectrometer for Space Applications - Field Tests; 21) Application of Laser Induced Breakdown Spectroscopy (LIBS) to Mars Polar Exploration: LIBS Analysis of Water Ice and Water Ice/Soil Mixtures; 22) LIBS Analysis of Geological Samples at Low Pressures: Application to Mars, the Moon, and Asteroids; 23) In-Situ 1-D and 2-D Mapping of Soil Core and Rock Samples Using the LIBS Long Spark; 24) Rocks Analysis at Stand Off Distance by LIBS in Martian Conditions; 25) Evaluation of a Compact Spectrograph/Detection System for a LIBS Instrument for In-Situ and Stand-Off Detection; 26) Analysis of Organic Compounds in Mars Analog Samples; 27) Report of the Organic Contamination Science Steering Group; 28) The Water-Wheel IR (WIR) - A Contact Survey Experiment for Water and Carbonates on Mars; 29) Mid-IR Fiber Optic Probe for In Situ Water Detection and Characterization; 30) Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water; 31) The Subsurface Ice Probe (SIPR): A Low-Power Thermal Probe for the Martian Polar Layered Deposits; 32) Deploying Ground Penetrating Radar in Planetary Analog Sites to Evaluate Potential Instrument Capabilities on Future Mars Missions; 33) Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument; 34) Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation; 35) A New Celestial Navigation Method for Mars Landers; 36) Mars Mineral Spectroscopy Web Site: A Resource for Remote Planetary Spectroscopy.

Source record↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

Potential Mercurian Analogues: Aubrite and Enstatite Chondrite Impact Melt Meteorites

The MESSENGER (MErcury Surface Space ENvironment GEochemistry and Ranging Spacecraft) mission provided new data that have helped us better constrain the surficial mineralogy and composition of Mercury. Mercury has an extremely low oxygen fugacity (f O2) (Iron Wustite (IW) -7.3 to IW -2.6), and at these unique conditions, elements, which usually exhibit lithophile behavior on Earth, can exhibit chalcophile or siderophile behavior on Mercury. No samples have been returned from Mercury; therefore, we must study candidate meteorite analogs to better understand the formation conditions of minerals inferred to be present at the Mercurian surface and Mercurian magmatic processes. In this study, we present a comprehensive analysis of a representative suite of eight aubrites and four enstatite chondrite impact melts (ECIM), which both have a similar f O2 to Mercury, and contain exotic sulfides that have been inferred to be present at the Mercurian surface. These characteristics allow us to assess their relevance for understanding the mineralogy and magmatic processes of Mercury. The ECIM were previously classified as aubrites, but we show that they are actually ECIM with a potential EH (high enstatite) parent body origin due to the presence of niningerite, Si-enriched kamacite, and uniform Ni in schreibersite. We propose that, with respect to the aubrites, the ECIM represent an ideal candidate for Mercurian studies due to their mineralogy and modal mineralogy. Compared to the aubrites, the ECIM samples do not contain forsterite or diopside, show a poorer sulfide diversity, contain graphite, and have a higher volume percentage of metal phases. Although the Mercurian surface contains forsterite and diopside, graphite and a similar amount of metal and sulfides as seen in the ECIM are inferred to be present on Mercury. According to the calculated normative Mercurian mineralogy, both candidate meteorites are most analogous to the Caloris Basin and Northern Plains Lower Mg regions.

Wilbur, Zoe E.↗

Automatic bio-sample bacteria detection system

Electromechanical device analyzes urine specimens in 15 minutes and processes one sample per minute. Instrument utilizes bioluminescent reaction between luciferase-luciferin mixture and adenosine triphosphate (ATP) to determine number of bacteria present in the sample. Device has potential application to analysis of other body fluids.

Chappelle, E. W.↗

An inventory of California's irrigated land

Currently in the fourth year of its applications pilot test project to assess irrigated lands for water management, California officials found that the performance goal of plus or minus 5% at the 95% confidence level by each of the state's 10 major hydrologic basins was bettered in all but a few cases using manual analysis techniques for estimation. The process used was photointerpretation of enlarged LANDSAT scenes (1:150,000 scale), adjusting the determined acreage using a regression estimator and ground truth data from 637 sample cells. Sample cells were allocated to areas stratified on the basis of field size and selected crop types. Interpretation of three dates of imagery was required to span the complete time during which irrigated crops are grown in California. The registration of multitemporal data and classification procedures for estimating irrigated land using digital techniques are being studied as part of the second task in the project.

Sawyer, G. B.↗

Preparation and cleanliness verifications of a space simulation chamber for contamination sensitive test specimens

Contamination sensitive optical devices were to be evaluated under thermal vacuum conditions. Test specifications called for an extremely clean chamber environment, ambient temperature chamber walls, and optical surface temperatures at approximately - 30 C. Chamber preparation included the replacement of diffusion pumps with cryopumps and the cleaning of the chamber walls to reduce contamination levels. Chamber cleaning using vacuum bake was tried and abandoned as time consuming and ineffective. Chemical cleaning and cleanliness verification methods were developed. Gas chromatograph analysis techniques were used extensively throughout the cleaning process to verify cleanliness levels prior to evacuating the chamber. A chamber cleanliness verification test using a thermoelectric quartz crystal microbalance and witness samples was performed to demonstrate that an appropriate cleanliness level was achieved.

Koch, W. R.↗

Study of the production of some superconducting and magnetic materials by solidification in the drop tube and drop tower

A systematic study on the relationship between the microstructure and physical properties of several superconducting materials prepared by solidification in low gravity was conducted. Further study of the materials, such as the applications of hydrostatic pressure which is known to be an effective mean to vary the electronic structure of materials, in conjunction with the detailed microstructure analysis of the samples was also performed to better understand the low gravity effects on the enhancement of the electronic properties. Results of the studies on the directionally solidified AlInSn alloys processed in the KC-135 aircraft and immiscible GaBi alloy prepared during free fall in the Marshall Space Flight Center Drop Tower are presented.

Wu, M. K.↗

A statistical comparison of two carbon fiber/epoxy fabrication techniques

A statistical comparison of the compression strengths of specimens that were fabricated by either a platen press or an autoclave were performed on IM6/3501-6 carbon/epoxy composites of 16-ply (0,+45,90,-45)(sub S2) lay-up configuration. The samples were cured with the same parameters and processing materials. It was found that the autoclaved panels were thicker than the platen press cured samples. Two hundred samples of each type of cure process were compression tested. The autoclaved samples had an average strength of 450 MPa (65.5 ksi), while the press cured samples had an average strength of 370 MPa (54.0 ksi). A Weibull analysis of the data showed that there is only a 30 pct. probability that the two types of cure systems yield specimens that can be considered from the same family.

Hodge, A. J.↗

The EXOSAT database and archive

The EXOSAT database provides on-line access to the results and data products (spectra, images, and lightcurves) from the EXOSAT mission as well as access to data and logs from a number of other missions (such as EINSTEIN, COS-B, ROSAT, and IRAS). In addition, a number of familiar optical, infrared, and x ray catalogs, including the Hubble Space Telescope (HST) guide star catalog are available. The complete database is located at the EXOSAT observatory at ESTEC in the Netherlands and is accessible remotely via a captive account. The database management system was specifically developed to efficiently access the database and to allow the user to perform statistical studies on large samples of astronomical objects as well as to retrieve scientific and bibliographic information on single sources. The system was designed to be mission independent and includes timing, image processing, and spectral analysis packages as well as software to allow the easy transfer of analysis results and products to the user's own institute. The archive at ESTEC comprises a subset of the EXOSAT observations, stored on magnetic tape. Observations of particular interest were copied in compressed format to an optical jukebox, allowing users to retrieve and analyze selected raw data entirely from their terminals. Such analysis may be necessary if the user's needs are not accommodated by the products contained in the database (in terms of time resolution, spectral range, and the finesse of the background subtraction, for instance). Long-term archiving of the full final observation data is taking place at ESRIN in Italy as part of the ESIS program, again using optical media, and ESRIN have now assumed responsibility for distributing the data to the community. Tests showed that raw observational data (typically several tens of megabytes for a single target) can be transferred via the existing networks in reasonable time.

Reynolds, A. P.↗

Collection requirements for trace-element analyses of extraterrestrial samples

Trace-element abundances have proven important in understanding the evolution of and interrelationships between different meteorites. Preliminary investigations of the trace-element contents of interplanetary dust particles indicate that trace-element abundances will prove equally important in distinguishing between micrometeorites of different types, comparing the interplanetary dust to the meteorites, and assessing the degree of thermal alteration experienced either on the parent body or during the collection process. Sample collection, delivery, and curation must be accomplished in a manner to avoid contamination with even trace amounts of the elements to be analyzed. The present SXRF sensitivity for micrometeorite analysis is of order 1 femtogram, but anticipated improvements in sensitivity will require sample contamination substantially below this level. Sample collection and handling equipment should be constructed from materials selected for ultrahigh purity, and serious consideration should be given in selecting the particular set of elements from which the collection apparatus is composed so as not to compromise useful information.

Flynn, George J.↗

The Composition of Organics and Volatiles in the Interstellar Medium

Tremendous progress has been made in our understanding of the composition of interstellar dust through the combined use of telescopic observations, theoretical models, laboratory studies of analogs, and the analysis of interstellar samples found in meteorites. It is increasingly clear that the interstellar medium (ISM) contains an enormous diversity of materials created by a wide range of chemical and physical processes. This paper reviews some of our current knowledge of the organic and volatile materials thought to exist in the ISM. These compounds supply a significant portion of the material that makes up the interstellar dense molecular clouds from which new stars and planetary systems are formed, and thus represents an important reservoir of material that could play key roles in the formation and evolution of life. This paper will largely focus on solid materials, as opposed to gases, since solids contain a major fraction of the heavier elements in clouds and because solids are most likely to survive incorporation into new planetary systems in identifiable form. The paper concludes with a brief discussion of the astrobiological relevance of some of the compounds now known or suspected to be present in the ISM.

Sandford, Scott A.↗