Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Bionutrients-1: Utilizing Genomics and Transcriptomics to Assess the Reliability of Microorganisms for In Situ Nutrient Production on Long Duration Missions

The resupply of current long-duration crewed missions to the ISS relies on ground-launched supplies. As NASA looks toward Mars, ground-based resupply will no longer be an option. Critical nutrients, including vitamin C, vitamin K, folate, and thiamin, degrade during long-term storage, and regular consumption of these nutrients is essential for astronaut health. Another challenge of current food systems is the difficulty of consuming sufficient calories when subsisting on the limited flavors of freeze-dried food, which can lead to weight loss. The inclusion of microorganism-based food systems could alleviate both concerns. For example, the fermentation of rehydrated milk into yogurt with microorganisms genetically incorporating genes to produce critical vitamins would allow for both in situ production of nutrients and a fresh food product with additional flavor profiles. In comparison to plant food production, microorganisms require less flight infrastructure. The BioNutrients-1 mission is demonstrating viability of microbial fermentation food production in microgravity and testing the reliability of this approach for long-duration missions lacking resupply. While the BioNutrients-1 mission includes the collection of multiple phenotypic measurements, this status update will focus on the processing of samples for genomics and transcriptomics analyses as well as the planned analysis pipelines. First, the BioNutrients-1 mission seeks to identify microorganisms capable of surviving long-duration storage at ambient temperatures while maintaining genetic fidelity. To achieve this, nine commonly employed microbial species were stored at ambient temperatures in Stasis Packs on the ISS for five years. The viability and mutation rates will be measured at multiple time points for both flown and ground control samples. From an omics perspective, the changes in the bulk rates of point mutations and genetic rearrangements across the Stasis Pack species during the five years of storage will be determined, providing valuable insights into the potential of these microorganisms for long-duration space missions. Second, the BioNutrients-1 mission is characterizing the impact of microgravity on fermentation. Two strains of the yeast Saccharomyces cerevisiae, each encoding antioxidants (β-carotene or zeaxanthin) were flown to ISS for storage and fermentation within simplified bioreactors (Production Packs). The impact of microgravity on the expression of the antioxidant production genes and general metabolic genes will be determined using RNA sequencing. Ultimately, the transcriptome data will be compared to phenotypic measurements, such as the antioxidant yield, end-state biomass, and the production of EtOH, to determine the impacts of microgravity and long-term storage on microbial fermentation. The findings from this research will be instrumental in understanding the challenges and opportunities of microorganism-based food systems in space missions.

BioNutrients↗

Feasibility of a Fieldable Mass Spectrometer FY 2015 Year-end Report

Currently, the International Atomic Energy Agency (IAEA) monitors the production of enriched uranium hexafluoride (UF 6 ) at declared facilities by collecting a few grams of product in sample tubes that are then sent to central laboratories for processing and isotope ratio analysis by thermal ionization mass spectrometry. Analysis of results may not be available for some time after collection. In addition, new shipping regulations will make it more difficult to transport this amount of UF 6 to a laboratory. The IAEA is interested in an isotope ratio technique for uranium in UF 6 that can be moved to and operated at the enrichment facility itself. This report covers the tasks and activities of the Feasibility of a Fieldable Mass Spectrometer Project for FY 2015, which investigates the feasibility of an in-field isotope ratio technique— the forward deployment of a technique to the non-laboratory situation of a protected room with power and heat at the facility of interest. A variety of nontraditional elemental ionization techniques were considered. It was determined that only two of these should be moved forward for testing with the candidate in-field mass spectrometer and with the adsorbed UF 6 sample types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Amorphous Chains in Nanoplastic Formation from Semicrystalline Polymers

Semicrystalline polymers, e.g., polyethylene terephthalate (PET), release micro- (100 nm to 1 mm) and nanoplastics (up to 100 nm) [MNPL] when they are degraded under quiescent conditions. However, the exact molecular mechanisms leading to material fragmentation into MNPL are unknown. Here, we monitor the evolution of chain molecular weight and the MNPL production kinetics during hydrolysis of PET pellets. We find that only ~0.6% of the amorphous phase ester bonds are hydrolyzed at the onset of MNPL release. Then, by combining a random scission model with measured amorphous spacings, we estimate that only ~15% of the stress transmitters in the amorphous phase, namely, bridges and entangled loops, have failed by this point. Thus, spontaneous fragmentation of the semicrystalline nanostructure occurs despite significant intercrystalline connectivity. We resolve this apparent contradiction by proposing that fragmentation can only occur when progressive tie-chain scission causes the material to undergo the ductile/brittle transition. Mechanistically, we speculate that the internal stresses responsible for material fragmentation are caused by processing (i.e., residual stresses) and/or sample densification induced by chemi-crystallization. We discuss additional factors that may affect our analysis and thus require further investigation, such as skin-core effects, preferential degradation of stress transmitters and/or recrystallization processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Some aspects of analytical chemistry as applied to water quality assurance techniques for reclaimed water: The potential use of X-ray fluorescence spectrometry for automated on-line fast real-time simultaneous multi-component analysis of inorganic pollutants in reclaimed water

The potential use of isotopically excited energy dispersive X-ray fluorescence (XRF) spectrometry for automated on line fast real time (5 to 15 minutes) simultaneous multicomponent (up to 20) trace (1 to 10 parts per billion) analysis of inorganic pollutants in reclaimed water was examined. Three anionic elements (chromium 6, arsenic and selenium) were studied. The inherent lack of sensitivity of XRF spectrometry for these elements mandates use of a preconcentration technique and various methods were examined, including: several direct and indirect evaporation methods; ion exchange membranes; selective and nonselective precipitation; and complexation processes. It is shown tha XRF spectrometry itself is well suited for automated on line quality assurance, and can provide a nondestructive (and thus sample storage and repeat analysis capabilities) and particularly convenient analytical method. Further, the use of an isotopically excited energy dispersive unit (50 mCi Cd-109 source) coupled with a suitable preconcentration process can provide sufficient sensitivity to achieve the current mandated minimum levels of detection without the need for high power X-ray generating tubes.

Ling, A. C.↗

Performance modeling & simulation of complex systems (A systems engineering design & analysis approach)

Modeling of the Multi-mission Image Processing System (MIPS) will be described as an example of the use of a modeling tool to design a distributed system that supports multiple application scenarios. This paper examines: (a) modeling tool selection, capabilities, and operation (namely NETWORK 2.5 by CACl), (b) pointers for building or constructing a model and how the MIPS model was developed, (c) the importance of benchmarking or testing the performance of equipment/subsystems being considered for incorporation the design/architecture, (d) the essential step of model validation and/or calibration using the benchmark results, (e) sample simulation results from the MIPS model, and (f) how modeling and simulation analysis affected the MIPS design process by having a supportive and informative impact.

Hall, Laverne↗

Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry

Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein–protein and protein–ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chirp Scaling Algorithms for SAR Processing

The chirp scaling SAR processing algorithm is both accurate and efficient. Successful implementation requires proper selection of the interval of output samples, which is a function of the chirp interval, signal sampling rate, and signal bandwidth. Analysis indicates that for both airborne and spaceborne SAR applications in the slant range domain a linear chirp scaling is sufficient. To perform nonlinear interpolation process such as to output ground range SAR images, one can use a nonlinear chirp scaling interpolator presented in this paper.

nonlinear chirp scaling.↗

Coherent Digital Demodulation of a Residual Carrier Signal Using IF Sampling

An analysis is presented of a digital technique for the coherent demodulation of a residual carrier signal with a biphase modulated square wave subcarrier. The processing technique employs the concept of intermediate frequencies IF sampling. An optimum Costas loop is used for subcarrier demodulation and data-aided carrier tracking, i.e., combined Costas and residual carrier tracking. It is shown that the loops perform essentially the same as the corresponding analog loops in terms of signal-to-noise ratio and loop bandwidth. The sampling does not introduce biases or other significant effects on the loops, provided that the loop bandwidth is very small compared to the symbol rate, and that the number of samples per symbol is large compared to inverse loop bandwidth.

Sfeir, R.↗

Carbon dioxide (CO2) flux, amplicon sequencing and liquid chromatography–mass spectrometry (LC-MS) data for pyrogenic organic matter (PYOM) amended soil incubations in lab, Madison, WI, 2021-22

This dataset comprises soil-pyrogenic organic matter (PyOM) incubation experiments conducted in a laboratory setting. The focus was on measuring carbon dioxide (CO2) flux emitted in the headspace of incubation jars over a one-month period. The aim was to estimate carbon mineralization from two different carbon fractions in PyOM, as well as carbon mineralization from soil organic carbon (SOC). Bacterial and fungal community profiles were tracked at various time points during the incubation to observe changes in the overall community and specific responders to PyOM. LC-MS analysis of soil samples was also performed to monitor changes in the soil's chemical composition.The provided dataset includes processed CO2 flux measurements obtained from the Picarro-multiplexer measurement setup for each sample incubation jar. This data is available in the "CO2Flux.csv" file. Additionally, the dataset includes CO2 flux data partitioned to estimate mean carbon mineralization from the two PyOM carbon fractions, bulk PyOM, and SOC. The cumulative carbon mineralization data is provided in "cml_respired.csv," while the rate of carbon mineralization data is in "rate_respired.csv." The file "cml_respired_lastcyc.csv" contains cumulative carbon mineralization data for the PyOM carbon fractions, bulk PyOM, and SOC throughout the entire incubation period.For the LC-MS analysis, the raw data can be found in the "20220721_NZ_PeakHeights_FinalAnalysis.csv" file, while sample metadata is provided in "20220721_NZpilot_Metadata.csv". Processed LC-MS data is available in the file "20220721_NZ_FINAL_msdat_sub3.csv". Lastly, the dataset includes the relative abundance data for bacterial genera that exhibited a significant positive response to the addition of PyOM produced at 350 degrees Celsius, which can be found in "resp_genera_350.csv".

54 ENVIRONMENTAL SCIENCES↗

Thermal analysis of Bridgman-Stockbarger growth

A thermal analysis of a cylindrical HgCdTe sample in a Bridgman-Stockbarger crystal growth configuration was conducted with emphasis on the thermal profile, interface shape and position, and the thermal gradients at the liquid-solid interface. Alloys of HgTe and CdTe with compositions approximating 20 percent CdTe, 80 percent HgTe were used. This composition results in a bandgap suited for the detection of 10.6 micron CO2 radiation. The sensitivity of the sample thermal characteristics to important growth parameters, such as thermal diffusivities, thermal conductivities, furnace temperature profile, ampoule dimensions, and growth velocity was assessed. Numerical techniques and associated computational models necessary to analyze the heat transfer process within the sample and the Bridgman-Stockbarger boundary conditions were developed. This thermal analysis mode was programmed in FORTRAN V, and is currently operational on the MSFC Univac 1100 system.

Knopf, F. W.↗

On-Orbit Quantitative Real-Time Gene Expression Analysis Using the Wetlab-2 System

NASA Ames Research Center's WetLab-2 Project enables on-orbit quantitative Reverse Transcriptase PCR (qRT-PCR) analysis without the need for sample return. The WetLab-2 system is capable of processing sample types ranging from microbial cultures to animal tissues dissected on-orbit. The project developed a RNA preparation module that can lyse cells and extract RNA of sufficient quality and quantity for use as templates in qRT-PCR reactions. Our protocol has the advantage of using non-toxic chemicals and does not require alcohols or other organics. The resulting RNA is dispensed into reaction tubes that contain all lyophilized reagents needed to perform qRT-PCR reactions. System operations require simple and limited crew actions including syringe pushes, valve turns and pipette dispenses. The project selected the Cepheid SmartCycler (TradeMark), a Commercial-Off-The-Shelf (COTS) qRT-PCR unit, because of its advantages including rugged modular design, low power consumption, rapid thermal ramp times and four-color multiplex detection. Single tube multiplex assays can be used to normalize for RNA concentration and integrity, and to study multiple genes of interest in each module. The WetLab-2 system can downlink data from the ISS to the ground after a completed run and uplink new thermal cycling programs. The ability to conduct qRT-PCR and generate results on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. Specifically, the ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. On orbit gene expression analysis can also eliminate the confounding effects on gene expression of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of fixed samples and provide on-orbit gene expression benchmarking prior to sample return. Finally, the system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental pathogens and crew health. The validation flight of the WetLab-2 system using E. coli bacteria and mouse liver launched on SpaceX-7 in June 2015 and will remain on the ISS National Laboratory.

ISS tools↗

Visualizing metagenomic and metatranscriptomic data: A comprehensive review

The fields of Metagenomics and Metatranscriptomics involve the examination of complete nucleotide sequences, gene identification, and analysis of potential biological functions within diverse organisms or environmental samples. Despite the vast opportunities for discovery in metagenomics, the sheer volume and complexity of sequence data often present challenges in processing analysis and visualization. This article highlights the critical role of advanced visualization tools in enabling effective exploration, querying, and analysis of these complex datasets. Emphasizing the importance of accessibility, the article categorizes various visualizers based on their intended applications and highlights their utility in empowering bioinformaticians and non-bioinformaticians to interpret and derive insights from meta-omics data effectively.

59 BASIC BIOLOGICAL SCIENCES↗

Omics-Lethal Human Viruses, West Nile Experiment WCB001

The purpose of this experiment was to evaluate the host response to wild-type West Nile virus (WNV-NY99 382) and mutant WNV-E218A virus infection. Sample data was obtained from mouse cerebellum tissue and processed for mRNA, miRNA, proteomics, metabolomics, and lipidomics expression analysis. Tissues from this experiment were matched to tissues from GSE77193 (WCT001), using 1/4 of the cortex and 1/2 of cerebellum from the same mice. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Leveraging unique high-resolution Omics capabilities for proteomics, metabolomics, lipidomics, and transcriptomics dataset downloads each have a direct relationship to a primary sample submission corresponding to a specific West Nile virus infection.

59 BASIC BIOLOGICAL SCIENCES↗

Combinations of NIR, Raman spectroscopy and physicochemical measurements for improved monitoring of solvent extraction processes using hierarchical multivariate analysis models

The reliability of chemical processes can be greatly improved by implementing inline monitoring systems. Combining multivariate analysis with non-destructive sensors can enhance the process without interfering with the operation. Here, we present here hierarchical models using both principal component analysis and partial least square analysis developed for different chemical components representative of solvent extraction process streams. A training set of 380 samples and an external validation set of 95 samples were prepared and Near infrared and Raman spectral data as well as conductivity under variable temperature conditions were collected. The results from the models indicate that careful selection of the spectral range is important. By compressing the data through Principal Component Analysis (PCA), we lower the rank of the data set to its most dominant features while maintaining the key principal components to be used in the regression analysis. Within the studied data set, concentration of five chemical components were modeled; total nitrate (NO 3 - ), total acid (H + ), neodymium (Nd 3+ ), sodium (Na + ), and ionic strength (I.S.). The best overall model prediction for each of the species studied used a combined data set comprised of complementary techniques including NIR, Raman, and conductivity. Finally, our study shows that chemometric models are powerful but requires significant amount of carefully analyzed data to capture variations in the chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmological parameter uncertainties from SALT-II type Ia supernova light curve models

We use simulated type Ia supernova (SN Ia) samples, including both photometry and spectra, to perform the first direct validation of cosmology analysis using the SALT-II light curve model. This validation includes residuals from the light curve training process, systematic biases in SN Ia distance measurements, and a bias on the dark energy equation of state parameter w. Using the SN-analysis package SNANA, we simulate and analyze realistic samples corresponding to the data samples used in the SNLS3 analysis: ∼120 low-redshift (z < 0.1) SNe Ia, ∼255 Sloan Digital Sky Survey SNe Ia (z < 0.4), and ∼290 SNLS SNe Ia (z ≤ 1). To probe systematic uncertainties in detail, we vary the input spectral model, the model of intrinsic scatter, and the smoothing (i.e., regularization) parameters used during the SALT-II model training. Using realistic intrinsic scatter models results in a slight bias in the ultraviolet portion of the trained SALT-II model, and w biases (w {sub input} – w {sub recovered}) ranging from –0.005 ± 0.012 to –0.024 ± 0.010. These biases are indistinguishable from each other within the uncertainty; the average bias on w is –0.014 ± 0.007.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser Induced Breakdown Spectroscopy analysis of europium and samarium in aluminum oxide

The use of Laser Induced Breakdown Spectroscopy as a technique for analysis of europium and samarium concentrations in ceramic aluminum oxide samples was investigated for application to studying lanthanide separation processes. Metal oxide powders of europium and/or samarium were mixed with aluminum oxide at varying concentrations and pressed into pellets. A comparison of different approaches to building a univariate simple linear regression analysis curve is presented. A linear behavior was seen over the total lanthanide concentration range from 0.086 to 12.358 weight percent (wt%). In conclusion, the calculated limits of detection for the univariate calibration curves were determined to range from 0.001 to 0.108 wt% and 0.001 and 0.183 wt% for europium and samarium, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated analysis of video data

A software/hardware system designed and developed to perform automated video imagery analysis is described. Major elements included in the analysis system are: (1) sampling oscilloscope; (2) programmable trigger unit; (3) central computer; and (4) software processing library. The function of the scope and trigger unit, in conjunction with the control computer, is to digitize the selected portion of the video image and store as amplitude and time data in computer memory. Evaluation of the video data, analogus to interpretation of a visual image, is accomplished by the processing software. It is indicated that this technique of video image analysis is applicable to a wide variety of nonaerospace applications involving video data and image analysis.

Hafner, D. J.↗

Actual Waste Demonstration of the Nitric-Glycolic Flowsheet for Sludge Batch 9 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs qualification testing to demonstrate that the sludge batch is processable. Testing performed by the Savannah River National Laboratory has shown glycolic acid to be effective in replacing the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the catalytic generation of hydrogen and ammonia which could allow purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective rheology adjustment, and is favorable with respect to melter flammability. In order to implement the new flowsheet, SRAT and SME cycles, designated SC-18, were performed using a Sludge Batch (SB) 9 slurry blended from SB8 Tank 40H and Tank 51H samples. The SRAT cycle involved adding nitric and glycolic acids to the sludge, refluxing to steam strip mercury, and dewatering to a targeted solids concentration. Data collected during the SRAT cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. The SME cycle demonstrated the addition of glass frit and the replication of six canister decontamination additions. The demonstration concluded with dewatering to a targeted solids concentration. Data collected during the SME cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. Slurry and condensate samples were collected for subsequent analysis

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗