Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Understanding the unique optical and vibrational signatures of sequential infiltration synthesis derived indium oxyhydroxide clusters for CO 2 absorption

Sequential infiltration synthesis (SIS) is a vapor phase synthesis technique with potential to exert precise control over metal oxyhydroxide incorporation into polymer scaffolds. Here, we observe strong size-dependent properties of InO x (OH) y few-atom clusters deposited with variable SIS cycle numbers within a polymethylmethacrylate (PMMA) matrix. Infrared spectroscopy and ultraviolet-visible absorption spectroscopy reveal that the metal atom coordination and optical properties of the clusters depend on the number of SIS cycles performed as well as the choice of processing parameters. The incorporation of indium oxyhydroxide in PMMA via SIS presents an opportunity to improve the CO 2 absorption capacity and gas selectivity of inexpensive polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Exploring the Neutron Substructure with Advanced Polarized Helium-3 Targets (Or: How I Learned to Stop Worrying and Love Spectroscopy)

As we seek to understand the smallest, physical aspects of our universe, we cannot simply rely on our senses to probe the world around us as we did in the past. The smallest physical elements of our universe behave in strange, probabilistic ways and are completely invisible to the naked eye/ear/etc. So, we design clever experiments (such as scattering experiments) to probe these minute realms. Then, just as with the larger, observable world, we devise models and equations to describe what we think is happening. Due to the nature of the physical universe at the quantum scale and with the aid of symmetries such as Lorentz invariance, we can write down equations that describe the scattering, but the expressions contain functions, which we call ?form factors? and ?structure functions?, that we cannot compute from first principles. We can, however, formulate models that make predictions for these functions. By comparing our predictions with the observed data, we can gain insight into the validity of our models and thus a better physical understanding of what is happening at these minuscule scales. Studying the constituents inside of the nucleus of an atom adds another layer of difficulty if we can?t remove those components from the nucleus. This is the case with the neutron. When not bound in the nucleus with protons and other neutrons, the neutron will decay into a proton after about 15 minutes. So, we?re forced to study the neutron while it is still bound in the nucleus of an atom such as helium-3 (3He). For the last 1,000 years (rounding up), our group has developed high quality, polarized 3He targets made of an aluminosilicate glass. These targets are made in order to perform experiments at Jefferson Lab (JLab), experiments which let us determine the form factors and structure functions of the neutron by scattering polarized electrons from polarized neutrons (or rather polarized 3He). The specific experiments reported on in this thesis push the bounds of our understanding of the internal structure of the neutron. Good science is often about pushing experimental techniques to a new level. Toward that goal we study our polarized 3He targets both to advance the technology and to choose the best ones for our experiments. We do this using a process called nuclear magnetic resonance (NMR) to gauge the maximum polarization of a target and how fast the polarization decays with time. While these tests primarily provide us information that make analysis of our experimental scattering data possible, they also let us determine whether or not a target-cell is useful or even, dare I say, of spectacular quality. Our latest targets utilize a novel convection design allowing 3He to be polarized and quickly moved in front of the electron-beam, making it possible to use larger targets with higher electron-beam currents than ever before. This means more electrons scatter and we get more data. And by studying our targets in detail prior to using them in our experiments, we have found techniques to take effects which could have been detrimental to target quality and turn them to our advantage! It?s a real case of making lemonade out of lemons. We also use laser spectroscopy to study the absorption lines of alkali-metals in the target (potassium and rubidium, specifically). We add these alkali-metals to our target to facilitate polarizing the 3He. We can use the measurement of these pressure broadened absorption lines to determine the 3He density inside of the target with great precision. Historically, we understood the width of these lines would be dependent on the temperature of the target. Specifically, if I raise the temperature, the width should get bigger. I found that was not the case, which was very confusing at first, though very exciting now that I realize the data are self-consistent and suggestive of unexpected behavior. This thesis details the development of high quality, glass, polarized 3He targets for the 2020 An 1 /dn 2 and 2023 Gn E experiments, which utilized the first 3He convection targets and broke records in target quality. This thesis also covers the initial development of metal windows for the next-generation of 3He target-cells. Finally, this thesis documents the temperature dependence of the width of potassium (K) and rubidium (Rb) absorption lines as measured with laser spectroscopy.

Jantzi, Christopher↗

Development and validation of a quantitative proton NMR method for the analysis of pregnenolone

Pregnenolone (PREG) is an endogenous steroid frequently sold as an over-the-counter dietary supplement touted to promote neurological and immunological health. While the PREG dietary supplement is added to the diet for health benefits, there are no FDA approved PREG drugs. However, compounded PREG drug products are available to U.S. patients. The FDA works with state regulatory authorities on the oversight of compounding activities, including developing 503A and 503B lists of bulk substances that compounders are permitted to use. PREG is one of the substances publicly nominated to be included on the 503B list. Compounded hormone therapies such as those using PREG are of interest given the lack of standardization in compounded drug products which may increase the possibility of underdosing, overdosing, or contamination. However, no USP monograph currently exists to evaluate the quality of PREG drug substance or product. To address knowledge gaps and assist in quality control, a simple and rapid quantitative proton nuclear magnetic resonance spectroscopy (qNMR) method for the identification and assay of PREG in different types of PREG products was developed and validated. PREG samples were characterized using 1D 1 H and 2D 1 H– 13 C HSQC NMR spectra. The qNMR assay method (taking approximately 10 min per NMR spectrum) was validated for precision, accuracy, specificity, robustness and linearity per ICH Q2(R1) guidance. The method was validated in a range from 0.032 to 3.2 mg/mL. As a proof of concept, seven PREG bulk substance samples, three tablet and two capsule PREG dietary supplements were assessed by the qNMR analytical procedure. NMR data from all tested samples met the expected criteria for identification and assay. The results demonstrate the potential of qNMR for the quality assessment of different types of PREG samples.

60 APPLIED LIFE SCIENCES↗

Flat epitaxial quasi-1D phosphorene chains

The emergence of peculiar phenomena in 1D phosphorene chains (P chains) has been proposed in theoretical studies, notably the Stark and Seebeck effects, room temperature magnetism, and topological phase transitions. Attempts so far to fabricate P chains, using the top-down approach starting from a few layers of bulk black phosphorus, have failed to produce reliably precise control of P chains. We show that molecular beam epitaxy gives a controllable bottom-up approach to grow atomically thin, crystalline 1D flat P chains on a Ag(111) substrate. Scanning tunneling microscopy, angle-resolved photoemission spectroscopy, and density functional theory calculations reveal that the armchair-shaped chains are semiconducting with an intrinsic 1.80 ± 0.20 eV band gap. This could make these P chains an ideal material for opto-electronic devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrochemical reactivity and passivation of organic electrolytes at spinel MgCrMnO 4 cathode interfaces for rechargeable high voltage magnesium-ion batteries

Magnesium transition metal oxides such as MgCr 2−x Mn x O 4 are promising high-voltage and high-capacity cathode materials for rechargeable magnesium batteries (RMBs). Understanding and improving the chemical and electrochemical stability of the cathode–electrolyte interface (CEI) has been the primary technical emphasis to enable this category of cathode materials, which has been significantly underexplored. Herein, in this study, we focus on investigating the fundamental mechanism of parasitic reactions at the charged surface of the high-voltage MgCrMnO 4 model cathode with different organic electrolytes. The aim is to reveal the underlying effect of anions and solvents responsible for the passivation behavior of the cathode by using three exemplary anions: [(CF 3 SO 2 ) 2 N] − (TFSI − ), Al[OC(CF 3 ) 3 ] 4 − (TPFA − ), and [CB 11 H 12 ] − (MC) and three solvents: diglyme (G2), triglyme (G3), and 3-methoxypropylamine (MPA). High precision leakage current measurements during potentiostatic hold reveal that the electrolyte solvent chemistry has a more profound impact than anion's on the passivation of the MgCrMnO 4 cathode surface during deintercalation of Mg 2+ . X-ray photoelectron spectroscopy exhibits the differences in CEI composition. Amine solvents like MPA show poor passivation due to a higher degree of solvent decomposition, while the thin and anion-derived CEI in glyme-based electrolytes is directly linked with the better passivation behavior on the cathode. Furthermore, we leverage the knowledge from these findings to modify the electrolyte structure by adding a solvent additive, with the goal of reducing the parasitic reaction.

25 ENERGY STORAGE↗

Physics through the 1990s: Atomic, molecular and optical physics

The volume presents a program of research initiatives in atomic, molecular, and optical physics. The current state of atomic, molecular, and optical physics in the US is examined with respect to demographics, education patterns, applications, and the US economy. Recommendations are made for each field, with discussions of their histories and the relevance of the research to government agencies. The section on atomic physics includes atomic theory, structure, and dynamics; accelerator-based atomic physics; and large facilities. The section on molecular physics includes spectroscopy, scattering theory and experiment, and the dynamics of chemical reactions. The section on optical physics discusses lasers, laser spectroscopy, and quantum optics and coherence. A section elucidates interfaces between the three fields and astrophysics, condensed matter physics, surface science, plasma physics, atmospheric physics, and nuclear physics. Another section shows applications of the three fields in ultra-precise measurements, fusion, national security, materials, medicine, and other topics.

Source record↗

DD 13 - A very young and heavily reddened early O star in the Large Magellanic Cloud

This paper investigates the Large Magellanic Cloud star DD 13, which is likely the major ionizing source of the nebula N159A. New optical spectroscopy and new estimates of the broadband photometric properties of DD 13 are obtained. A spectral type of O3-O6 V, E(B-V) = 0.64, and M(V) = -6.93 is found. The spectral type cannot be more precisely defined due to contamination of the spectral data by nebular emission, obliterating the important He I classification lines. These results, plus a published estimate of the Lyman continuum photon injection rate into N159A, suggest that DD 13 actually consists of about 2-4 young, early O stars still enshrouded by their natal dust cloud. The star DD 13 may be a younger example of the type of tight cluster represented by the LMC 'star' Sk-66 deg 41, recently revealed to be composed of six or more components.

Conti, Peter S.↗

The size of the Proton: Recent Results from the PRad Experiment

Two new extremely high precision measurements of the proton rms charge radius performed in 2010-2013 with muonic hydrogen atom demonstrated up to six standard deviations smaller values than the accepted average from all previous experiments performed with different methods (scattering and atomic spectroscopy) on ordinary hydrogen. This discrepancy triggered the well-known ?proton radius puzzle? in hadronic physics. To address this puzzle, the PRad collaboration in spring of 2016 performed a novel magnetic-spectrometer-free ep-scattering experiment in Hall B at Jefferson Lab accumulating high statistics and a rich experimental data set. The specifics of the PRad experiment and the final physics results, including the extracted proton radius, as well as, the current status of the puzzle will be presented and discussed in this talk.

Gasparian, Ashot↗

Precise half-life determination of 131 Ba and 125 Xe

Barium-131 and Xenon-125 are valuable radioisotopes with numerous scientific and medical applications. Here, we produced both isotopes via proton irradiation of a cesium iodide (CsI) target at the Brookhaven Tandem Van de Graaff accelerator (BTVG). Following irradiation, we conducted systematic γ-ray spectroscopy measurements at the National Nuclear Data Center (NNDC) decay station using a calibrated High-Purity Germanium (HPGe) detector, collecting data over a 2-month period (spanning approximately 4.5 half-lives for 131 Ba). Through careful analysis of the characteristic γ-ray emissions from both isotopes, we determined the half-life of 131 Ba to be 11.55(6) days, which agrees with the previously evaluated value. For 125 Xe, we measured a half-life of 16.56(8) hours, slightly lower than the evaluated value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Coordination Behaviour of Cu I Photosensitizers Bearing Multidentate Ligands Investigated by X-ray Absorption Spectroscopy

A systematic series of four novel homo- and heteroleptic CuI photosensitizers based on tetradentate 1,10-phenanthroline ligands of the type X^N^N^X containing two additional donor moieties in the 2,9-position (X=SMe or OMe) were designed. Their solid-state structures were assessed by X-ray diffraction. Cyclic voltammetry, UV-vis absorption, emission and X-ray absorption spectroscopy were then used to determine their electrochemical, photophysical and structural features in solution. Following, time-resolved X-ray absorption spectroscopy in the picosecond time scale, coupled with time-dependent density functional theory calculations, provided in-depth information on the excited state electron configurations. For the first time, a significant shortening of the Cu–X distance and a change in the coordination mode to a pentacoordinated geometry is shown in the excited states of the two homoleptic complexes. These findings are important with respect to a precise understanding of the excited state structures and a further stabilization of this type of photosensitizers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recycling of silver from silicon solar cells by laser debonding

A laser-debonding approach to silver electrode recovery from solar cells is presented to address the critical need for efficient and eco-friendly recycling methods. The study explores the use of UV nanosecond and IR continuous-wave lasers to precisely debond silver electrodes from silicon wafers. By optimizing parameters like laser power, scan speed, and the number of passes, intact silver electrical contact lines were recovered from solar cells. Scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDS) analysis confirmed the successful separation of silver from silicon wafers. Furthermore, an increase in the number of laser passes led to the production of silver microparticles, as validated by morphology and compositional studies using EDS. The estimated silver is approximately 90 mg for the Si solar cells of 15.4 * 15.4 cm 2 used in the study. To achieve a large area recovery of silver, a MATLAB code incorporating detection algorithms and specific criteria to automate laser scanning by accurately identifying the location of silver electrodes was developed. This presented laser debonding method is not confined to silicon solar cells but can be extended to other solar cell types featuring metal electrodes, offering a versatile solution. By minimizing the use of hazardous chemicals and reducing operational costs, the developed process aligns with the imperative of environmentally responsible photovoltaic waste management.

14 SOLAR ENERGY↗

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 micrometers thick) that are wrapped around the sample tray assembly. Soda lime spheres (approximately 49 m in diameter) have been accelerated with a light-gas-gun into flight-grade Al foils at 6.35 km s(sup -1) to simulate the potential capture of cometary debris. The preserved crater penetrations have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, high-precision focused ion beam (FIB) milling has been used to isolate and then extract an individual melt residue droplet from the interior wall of an impact penetration. This enabled further detailed elemental characterization, free from the background contamination of the Al foil substrate. The ability to recover pure melt residues using FIB will significantly extend the interpretations of the residue chemistry preserved in the Al foils returned by Stardust.

Graham, G. A.↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Chemical structure and complex growth modes of magnesium silicate hydrate: Nanoparticle orientation, aggregation, and fusion

The extent of utilization of magnesium silicate hydrate (MSH) in construction is limited partly because of insufficient data ascertaining the kinetics of its precipitation. In this report MSH grown homogeneously or heterogeneously in the range of magnesium to silicon solution molar concentration ratios, [Mg]/[Si] = 0.5-1.5, and temperature = 25-80 °C was analyzed for its chemical structure and morphology. Infrared spectroscopy and geochemical modeling show that increasing the [Mg]/[Si] ratio results in less silicate polymerization in MSH. Atomic force microscopy reveals the presence of nanoparticles that aggregate and fuse to form films. Oriented attachment of nanoparticles and features indicative of enhanced crystallinity were observed at higher temperatures and longer reaction times. These data provide direct evidence for the persistence of hierarchical structures (i.e., nanoparticles forming 3D microparticles and 2D film layers) at the nanoscale to mesoscale. These findings offer insights into the precise chemical synthesis of MSH and its widespread use as a binder for construction purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acousto-Optic Imaging Spectrometers for Mars Surface Science

NASA's long term plan for Mars sample collection and return requires a highly streamlined approach for spectrally characterizing a landing site, documenting the mineralogical make-up of the site and guiding the collections of samples which represent the diversity of the site. Ideally, image data should be acquired at hundreds of VIS and IR wavelengths, in order to separately distinguish numerous anticipated species, using principal component analysis and linear unmixing. Cameras with bore-sighted point spectrometers can acquire spectra of isolated scene elements, but it requires 10(exp 2) to 10(exp 2) successive motions and precise relative pointing knowledge in order to create a single data cube which qualifies as a spectral map. These and other competing science objectives have to be accomplished within very short lander/rover operational lifetime (a few sols). True, 2-D imaging spectroscopy greatly speeds up the data acquisition process, since the spectra of all pixels in the scene are collected at once. This task can be accomplished with cameras that use electronically tunable acousto-optic tunable filters (AOTFs) as the optical tuning element. AOTFs made from TeO2 are now a mature technology, and operate at wavelengths from near-UV to about 5 microns. Because of incremental improvements in the last few years, present generation devices are rugged, radiation-hard and operate at temperatures down to at least 150K so they can be safely integrated into the ambient temperature optics of in-situ instruments such as planetary or small-body landers. They have been used for ground-based astronomy, and were also baselined for the ST-4 Champollion IR comet lander experiment (CIRCLE), prior to cancellation of the ST-4 mission last year. AIMS (for Acousto-optic Imaging spectrometer), is a prototype lander instrument which is being built at GSFC with support by the NASA OSS Advanced Technologies and Mission Studies, Mars Instrument Definition and Development Program (MIDP). AIMS is capable of tunable spectroscopic imaging of surface mineralogy, ices and dust between 0.5 and 2.4 microns, at a resolving power (lambda/delta lambda) which is typically several hundred. The design spatial resolution, similar to IMP and SSI, will allow mapping at scales down to about 1 cm.

Glenar, D. A.↗