Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

A Nonstationary and Non-Gaussian Moving Average Model for Solar Irradiance

Historically, power has flowed from large power plants to customers. Increasing penetration of distributed energy resources such as solar power from rooftop photovoltaic has made the distribution network a two-way-street with power being generated at the customer level. The incorporation of renewables introduces additional uncertainty and variability into the power grid. Distribution network operation studies are being adapted to include renewables; however, such studies require high quality solar irradiance data that adequately reflect realistic meteorological variability. Data from satellite-based products are spatially complete, but temporally coarse, whereas solar irradiances exhibit high frequency variation at very fine timescales. We propose a new stochastic method for temporally downscaling global horizontal irradiance (GHI) to 1 min resolution, but we do not consider the spatial aspect due to limited availability of the in situ irradiance measurements. Solar irradiance's first and second-order structures vary diurnally and seasonally, and our model adapts to such nonstationarity. Empirical irradiance data exhibits highly non-Gaussian behavior; we develop a nonstationary and non-Gaussian moving average model that is shown to capture realistic solar variability at multiple timescales. We also propose a new estimation scheme based on Cholesky factors of empirical autocovariance matrices, bypassing difficult and inaccessible likelihood-based approaches. The model is demonstrated for a case study of three locations that are located in diverse climates through the United States. The model is compared against competitors from the literature and is shown to provide better uncertainty and variability quantification on testing data.

Cholesky factor↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

SEAS Communication Engine: An Extensible, Flexible Wrapper for Co-Simulation Agents

When modeling and analyzing the power grid and other large scale systems, researchers often express scenarios as optimization problems and feed them into advanced software solvers. In order to allow multiple solvers to communicate with each other and share data from different domains, the National Renewable Energy Laboratory (NREL) and associated Department of Energy (DOE) labs have developed a software framework called the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS). HELICS allows cosimulation via a collection of client libraries for different languages that can be called from the appropriate optimization software. However, these client libraries do not provide a higher level of abstraction beyond reading and writing data off of the shared HELICS bus. In this paper, we describe a new software library called the SEAS Communication Engine that exposes a higher-level API for running cosimulation problems. The SEAS Engine provides a class-based abstraction on top of the Python HELICS client, in order to allow users to implement their domain-specific cosimulations without needing to interact with core HELICS primitives. This will make adoption of HELICS and cosimulation in general easier, by exposing a simpler API. In the second part of the paper, we validate our library on a collection of different simulation examples, including the canonical IEEE 13 Bus Feeder. Lastly, we demonstrate using the SEAS Engine to directly call domain-specific code written in the Julia programming language. Our hope is that this will serve as a template for easily calling software in different programming languages via the SEAS Engine, thereby avoiding code duplication and complexity.

co-simulation↗

PMU-data-driven Event Classification in Power Transmission Grids

This paper presents an event classification in transmission grids. The convolutional neural network (CNN)-based classifier is proposed to capture the temporal similarity of time-synchronized data stream from phasor measurement units (PMUs). The proposed CNN is trained using Bayesian optimization to search for the best hyperparameters. The effectiveness of the proposed event classification is validated through the real-world dataset from the U.S. transmission grids. This dataset includes line outage, transformer outage, frequency, and oscillation events. The validation process also includes different PMU outputs, such as voltage magnitude, phase angle, current magnitude, frequency, and rate of change of frequency (ROCOF). The results show that ROCOF gives the best classification performance compared to other PMU outputs. In addition, it is shown that the classifier trained with a larger dataset has higher accuracy. Moreover, the superiority of the proposed method is validated through comparison with other state-of-the-art classification methods.

Niazazari, Iman↗

Trust Model System for the Energy Grid of Things Network Communications

Network communication is crucial in the Energy Grid of Things (EGoT). Without a network connection, the energy grid becomes just a power grid where the energy resources are available to the customer uni-directionally. A mechanism to analyze and optimize the energy usage of the grid can only happen through a medium, a communications network, that enables information exchange between the grid participants and the service provider. Security implementers of EGoT network communication take extraordinary measures to ensure the safety of the energy grid, a critical infrastructure, as well as the safety and privacy of the grid participants. With the dynamic nature of network communication of the EGoT, the information provided by the customer or the service provider can be falsified by a malicious attacker. Therefore, a trust model is necessary to monitor any abnormal activities. This paper describes a distributed trust model system that meets the need of the EGoT. This paper describes methods for evaluating and improving the distributed trust model using standard hypothesis testing metrics such as true positive, false positive, true negative, false negative, equal error rate, and F1 score. Example calculations are shown based on generated sample data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL Overview of Grid-Tied Power Electronics

This presentation focuses on the power electronics related research efforts carried out by researchers at the Power Systems Engineering Center at NREL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Supporting Cyber Security of Power Distribution Systems by Detecting Differences Between Real-time Micro-Synchrophasor Measurements and Cyber-Reported SCADA (Final Report)

As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Safe Reinforcement Learning for Emergency Load Shedding of Power Systems

The paradigm shift in the electric power grid necessitates a revisit of existing control methods to ensure the grid’s security and resilience. In particular, the increased uncertainties and rapidly changing operational conditions in power systems have revealed outstanding issues in terms of either speed, adaptiveness, or scalability of the existing control methods for power systems. On the other hand, the availability of massive real-time data can provide a clearer picture of what is happening in the grid. Recently, deep reinforcement learning (RL) has been regarded and adopted as a promising approach leveraging massive data for fast and adaptive grid control. However, like most existing machine learning (ML)- based control techniques, RL control usually cannot guarantee the safety of the power systems. In this paper, we introduce a novel method for safe RL-based load shedding of power systems that can enhance the safe voltage recovery of the electric power grid after experiencing faults. Numerical simulation on the IEEE 39-bus testcase is performed to demonstrate the effectiveness of the proposed safe RL emergency control, as well as its adaptive capability to faults not seen in the training.

reinforcement learning, emergency control, power g↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗