Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Assessment of the visibility impairment caused by the emissions from the proposed power plant at Boron, California

The current atmospheric conditions and visibility were modeled, and the effect of the power plant effluent was then added to determine its influence upon the prevailing visibility; the actual reduction in visibility being a function of meteorological conditions and observer-plume-target geometry. In the cases investigated, the perceptibility of a target was reduced by a minimum of 10 percent and a maximum of 100 percent. This significant visual impact would occur 40 days per year in the Edwards area with meteorological conditions such as to cause some visual impact 80 days per year.

Bergstrom, R. W.↗

Conceptual design of a lunar base solar power plant lunar base systems study task 3.3

The best available concepts for a 100 kW Solar Lunar Power Plant based on static and dynamic conversion concepts have been examined. The two concepts which emerged for direct comparison yielded a difference in delivered mass of 35 MT, the mass equivalent of 1.4 lander payloads, in favor of the static concept. The technologies considered for the various elements are either state-of-the-art or near-term. Two photovoltaic cell concepts should receive high priority for development: i.e., amorphous silicon and indium phosphide cells. The amorphous silicon, because it can be made so light weight and rugged; and the indium phosphide, because it shows very high efficiency potential and is reportedly not degraded by radiation. Also the amorphous silicon cells may be mounted on flexible backing that may roll up much like a carpet for compact storage, delivery, and ease of deployment at the base. The fuel cell and electrolysis cell technology is quite well along for lunar base applications, and because both the Shuttle and the forthcoming Space Station incorporate these devices, the status quo will be maintained. Early development of emerging improvements should be implemented so that essential life verification test programs may commence.

Source record↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators: Preprint

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Failure Mechanism Traceability and Application in Human System Interface of Nuclear Power Plants using RESHA

In recent years, there has been considerable effort to modernize existing and new nuclear power plants with digital instrumentation and control systems (DI&C). However, there has also been considerable concern both by industry and regulatory bodies for the risk and consequence analysis of these systems. Of particular concern are digital common cause failures (CCFs) specifically related to software defects. These “misbehaviors” by the software can occur in both the control and monitoring of a system. While many new methods have been proposed to identify potential software failure modes, such as Systems-theoretic Process Analysis (STPA), Hazard and Consequence Analysis for Digital Systems (HAZCADS), etc., these methods are focused primarily on the control action pathway of a system. In contrast, the information feedback pathway lacks unsafe control actions (UCAs), which are typically related to software basic events; thus, assessment of software basic events in such systems is unclear. In this work, we present the idea of intermediate processors and unsafe information flow (UIF) to help safety analysts trace failure mechanisms in the feedback pathway and how they can be integrated into a fault tree for improved assessment capability. The concepts presented are demonstrated in two comprehensive case studies, a smart sensor integrated platform for unmanned autonomous vehicles and another on a representative advanced human system interface (HSI) for safety critical plant monitoring. The qualitative software basic events are identified, and a fault tree analysis is conducted based on a modified Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) methodology. The case studies demonstrate the use of UIF and intermediate processors in the fault tree to improve traceability of software failures in highly complex digital instrumentation feedback. The improved method can also clarify fault tree construction when multiple component dependencies are present in the system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Failure Mechanism Traceability and Application in Human System Interface of Nuclear Power Plants using RESHA

In recent years, there has been considerable effort to modernize existing and new nuclear power plants with digital instrumentation and control systems (DI&C). However, there has also been considerable concern both by industry and regulatory bodies for the risk and consequence analysis of these systems. Of particular concern are digital common cause failures (CCFs) specifically related to software defects. These “misbehaviors” by the software can occur in both the control and monitoring of a system. While many new methods have been proposed to identify potential software failure modes, such as Systems-theoretic Process Analysis (STPA), Hazard and Consequence Analysis for Digital Systems (HAZCADS), etc., these methods are focused primarily on the control action pathway of a system. In contrast, the information feedback pathway lacks unsafe control actions (UCAs), which are typically related to software basic events; thus, assessment of software basic events in such systems is unclear. In this work, we present the idea of intermediate processors and unsafe information flow (UIF) to help safety analysts trace failure mechanisms in the feedback pathway and how they can be integrated into a fault tree for improved assessment capability. The concepts presented are demonstrated in two comprehensive case studies, a smart sensor integrated platform for unmanned autonomous vehicles and another on a representative advanced human system interface (HSI) for safety critical plant monitoring. The qualitative software basic events are identified, and a fault tree analysis is conducted based on a modified Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) methodology. The case studies demonstrate the use of UIF and intermediate processors in the fault tree to improve traceability of software failures in highly complex digital instrumentation feedback. The improved method can also clarify fault tree construction when multiple component dependencies are present in the system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Integration of a Concentrating Solar Steam Topping Turbine to an Existing Geothermal Binary Power Plant (CRADA CRD-17-700 Final Report)

U.S. Geothermal Inc. is a publicly traded leading renewable energy company focused on the development, production, and sale of electricity from geothermal energy with operating generation facilities at Raft River, Idaho; San Emidio, Nevada; and Neal Hot Springs, Oregon. (U.S. Geothermal was acquired by Ormat Technologies, Inc. since the execution of this project). This project will evaluate the integration of a concentrating solar steam topping cycle with a geothermal bottoming binary cycle. This hybrid plant configuration will enable high efficiency conversion of the solar heat to electrical power, while simultaneously increasing the power output of the bottoming cycle. Such a design has the potential to reduce the cost of electrical power from concentrating solar power (CSP) and geothermal plants, and a viable design could be deployed at existing geothermal plants that have experienced resource productivity decline as well as in greenfield projects. This analysis will examine US Geothermal’s Raft River power plant for implementation of this concept. INL and NREL have previously collaborated in the analysis of geo-solar hybrid power plants. These two labs will again work together to model the solar field, steam-topping, and geothermal bottoming cycles in order to investigate the performance of the proposed cycle. This analysis will provide US Geothermal with technical information including equipment specifications and estimated power generation necessary to advance the concept toward implementation. A successful project outcome has two parts: One would be for US Geothermal to have a process flow diagram (heat and mass balance), and performance parameters for the major pieces of equipment. US Geothermal could then use this information evaluate the techno-economic feasibility of the hybrid power cycle, and serve as the basis for subsequent detailed equipment design, purchase, and installation of the cycle. The second would be for the developed solution to be published by DOE for use by other geothermal developers both to retrofit underperforming plants and to lower the LCOE of new developments.

15 GEOTHERMAL ENERGY↗

Synthetic Methanol/Fischer–Tropsch Fuel Production Capacity, Cost, and Carbon Intensity Utilizing CO 2 from Industrial and Power Plants in the United States

Captured CO 2 is a potential feedstock to produce fuel/chemicals using renewable electricity as the energy source. In this study, we explored resource availability and synergies by region in the United States and conducted cost and environmental analysis to identify unique opportunities in each region to inform possible regional and national actions for carbon capture and utilization development. This study estimated production cost of synthetic methanol and Fischer–Tropsch (FT) fuels by using CO 2 captured from the waste streams emitted from six industrial [ethanol, ammonia, natural gas (NG) processing, hydrogen, cement, and iron/steel production plants] and two power generation (coal and NG) processes across the United States. The results showed that a total of 1594 million metric ton per year of waste CO 2 can be captured and converted into 85 and 319 billion gallons of FT fuels and methanol, respectively. FT fuels can potentially substitute for 36% of the total petroleum fuels used in the transportation sector in 2018. Technoeconomic analysis shows that the minimum selling prices for synthetic FT fuels and methanol are 1.8–2.8 times the price of petroleum fuel/chemicals, but the total CO 2 reduction potential is 935–1777 MMT/year.

54 ENVIRONMENTAL SCIENCES↗

Optimization of Mitigating System Performance Index to Improve Nuclear Power Plant Safety and Efficiency

MSPI (Mitigation System Performance Index) is one of the risk-informed, plant-specific performance indicators of NRC’s Reactor Oversight Process. MSPI is used by the regulator and nuclear industry to monitor and assess the performance of plant mitigating systems. In this project, a calculation tool has been developed by incorporating the plant operation data, Probabilistic Risk Assessment (PRA) data, and industry baseline values to automate the calculation process of MSPI and the generation of the report. This is the first stage in an effort to optimize the MSPI through advanced artificial intelligence (AI) and machine learning (ML) techniques to improve nuclear power plant safety and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow Redirection and Induction in Steady State (FLORIS) Wind Plant Power Production Data Sets

This dataset contains turbine- and plant-level power outputs for 252,500 cases of diverse wind plant layouts operating under a wide range of yawing and atmospheric conditions. The power outputs were computed using the Gaussian wake model in NREL's FLOw Redirection and Induction in Steady State (FLORIS) model, version 2.3.0. The 252,500 cases include 500 unique wind plants generated randomly by a specialized Plant Layout Generator (PLayGen) that samples randomized realizations of wind plant layouts from one of four canonical configurations: (i) cluster, (ii) single string, (iii) multiple string, (iv) parallel string. Other wind plant layout parameters were also randomly sampled, including the number of turbines (25-200) and the mean turbine spacing (3D-10D, where D denotes the turbine rotor diameter). For each layout, 500 different sets of atmospheric conditions were randomly sampled. These include wind speed in 0-25 m/s, wind direction in 0 deg.-360 deg., and turbulence intensity chosen from low (6%), medium (8%), and high (10%). For each atmospheric inflow scenario, the individual turbine yaw angles were randomly sampled from a one-sided truncated Gaussian on the interval 0 deg.-30 deg. oriented relative to wind inflow direction. This random data is supplemented with a collection of yaw-optimized samples where FLORIS was used to determine turbine yaw angles that maximize power production for the entire plant. To generate this data, a subset of cases were selected (50 atmospheric conditions from 50 layouts each for a total of additional 2,500 cases) for which FLORIS was re-run with wake steering control optimization. The IEA onshore reference turbine, which has a 130 m rotor diameter, a 110 m hub height, and a rated power capacity of 3.4 MW was used as the turbine for all simulations. The simulations were performed using NREL's Eagle high performance computing system in February 2021 as part of the Spatial Analysis for Wind Technology Development project funded by the U.S. Department of Energy Wind Energy Technologies Office. The data was collected, reformatted, and preprocessed for this OEDI submission in May 2023 under the Foundational AI for Wind Energy project funded by the U.S. Department of Energy Wind Energy Technologies Office. This dataset is intended to serve as a benchmark against which new artificial intelligence (AI) or machine learning (ML) tools may be tested. Baseline AI/ML methods for analyzing this dataset have been implemented, and a link to their repository containing those models has been provided. The .h5 data file structure can be found in the GitHub repository under explore_wind_plant_data_h5.ipynb.

AI↗

Efficient prediction of concentrating solar power plant productivity using data clustering

Concentrating solar power (CSP) plants convert solar energy to electricity and can be deployed with a thermal storage capability to shift electricity generation from time periods with available solar resource to those with high electricity demand or electricity price. Rigorous optimization of plant design and operational strategies can improve the market-competitiveness and commercial viability; however, such optimization may require hundreds of annual performance simulations, each of which can be computationally expensive when including considerations such as optimization of dispatch scheduling, sub-hourly time resolution, and stochastic effects due to uncertain weather or electricity price forecasts. This paper proposes a methodology to reduce the computational burden associated with simulation of electricity yield and revenue for CSP plants over a single- or multi-year period. Data-clustering techniques are employed to select a small number of limited-duration time blocks for simulation that, when appropriately weighted, can reproduce generation and revenue over a single year or within each year of a multi-year period. After selection of appropriate data features and weighting factors defining similarity between time-series profiles, the methodology captured annual revenue within 2.3%, 1.7%, or 1.2% using simulation of 10, 30, or 50 three-day exemplar time blocks, respectively, for each of three single-year location/weather/market scenarios and five plant configurations ranging from low to high solar multiple and storage capacity. When applied to multi-year datasets, the proposed methodology can capture inter-year variability that is unavailable from typical meteorological year (TMY) datasets while simultaneously requiring simulation of less than a single year of data.

14 SOLAR ENERGY↗

Cost Analysis of Heavy-Duty Vehicle Proton Exchange Membrane Fuel Cell Stationary Power Plants

Heavy-duty PEM fuel cells could be a low-cost, low emission alternative to combustion turbines for re-electrifying hydrogen if used as part of a long duration grid energy storage systems. Many studies expect heavy duty PEM fuel cell production costs to reduce as manufacturing volumes ramp up and their expected durability of 25,000-30,000 hours aligns well with a 30-year life for hydrogen seasonal energy storage plants that would likely operate less than 10% of the year. The labor, material, and equipment costs associated with installing PEM fuel cells and their required balance of plant for stationary applications have not been thoroughly explored, however. This study performs a detailed design and cost analysis of a 100 MW stationary PEM fuel cell power plant, capturing costs such as cooling, power electronics, pipes, valves, fittings, cabling, conduit, concrete foundations, buildings, and land. It employs methods consistent with NLR's solar PV benchmarking cost analysis and annual technology baseline to derive the total installed costs of stationary PEM fuel cell plants that utilize heavy duty PEM fuel cells.

08 HYDROGEN↗

Evaluation of a ducted-fan power plant designed for high output and good cruise fuel economy

Theoretical analysis of performance of a ducted-fan power plant designed both for high-output, high-altitude operation at low supersonic Mach numbers and for good fuel economy at lower fight speeds is presented. Performance of ducted fan is compared with performance (with and without tail-pipe burner) of two hypothetical turbojet engines. At maximum power, the ducted fan has propulsive thrust per unit of frontal area between thrusts obtained by turbojet engines with and without tail-pipe burners. At cruise, the ducted fan obtains lowest thrust specific fuel consumption. For equal maximum thrusts, the ducted fan obtains cruising flight duration and range appreciably greater than turbojet engines.

ENGINES, DUCTED PROPELLER↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Development of high concentration photovoltaics (HCPV) power plants in the US Southwest: Economic assessment and sensitivity analysis

High concentration photovoltaic (HCPV) technologies offer several advantages over typical PV systems. In this study, a detailed economic assessment and sensitivity analysis of deploying HCPV plants in the US southwest is performed. To do this, a 20 MWdc HCPV power plant is designed using the System Advisor Model (SAM) and is evaluated from both technical and financial aspects. The sensitivity analysis shows that reducing the installed cost per capacity of the HCPV system can significantly improve the economics and reduce the levelized cost of electricity (LCOE) and levelized power purchase agreement (LPPA). Also, providing proper incentives including both investment tax credits (ITC) and production tax credit (PTC), loan debt ratio, and interest rate are among the most influential parameters. The analysis shows that with the 30% ITC, the LCOE, and LPPA of the designed HCPV projects are between $65.4/MWh and $69.3/MWh and between $71.0/MWh and $75.2/MWh, respectively. The estimated LCOE and LPPA values are almost 50% higher than the utility-scale PV projects. If proper funding is provided to continue the support of the HCPV system, they would become more economical and competitive with PV plants. Federal and state government policies must also be established to advocate HCPV systems.

14 SOLAR ENERGY↗

Characterization of wind conditions and impact on wind loading at an operational parabolic trough concentrating solar power plant using LiDAR observations

Wind loading is a major factor influencing the structural design costs of Concentrating Solar Power (CSP) collector systems, including heliostats and parabolic troughs. Traditionally, these designs have been based on wind-tunnel data, which often fail to accurately represent the dynamic effects experienced at full scale. This study presents a first-of-its-kind experimental characterization of wind conditions within an operational parabolic-trough CSP power plant focusing specifically on using lidar observations. The lidar observations give a unique opportunity to provide insights into wind flow conditions deep within the trough arrays. Our results suggest that (1) after being blocked by the first few rows, the wind speed above the troughs recovers to 73% of its inflow magnitude as it flows further over the trough field due to enhanced turbulent mixing and (2) due to the wind speed recovery, troughs in the interior field will likely experience higher shear-induced turning moments compared those at the front. The conclusions from this work stress the importance of better understanding the wind patterns and interior wind loads when designing solar collectors and highlights the need for more interior load measurements in the future field campaigns.

17 WIND ENERGY↗

Manual of phosphoric acid fuel cell power plant optimization model and computer program

An optimized cost and performance model for a phosphoric acid fuel cell power plant system was derived and developed into a modular FORTRAN computer code. Cost, energy, mass, and electrochemical analyses were combined to develop a mathematical model for optimizing the steam to methane ratio in the reformer, hydrogen utilization in the PAFC plates per stack. The nonlinear programming code, COMPUTE, was used to solve this model, in which the method of mixed penalty function combined with Hooke and Jeeves pattern search was chosen to evaluate this specific optimization problem.

Lu, C. Y.↗

Characterization of Recovery Human Action Mechanisms in Nuclear Power Plants

Recovery human action is defined as the action that prevents deviant conditions from producing unwanted effects. Analyzing recovery actions has been a critical part in human reliability analysis (HRA). However, there are a couple of limitations to treat recovery actions only depending on the current HRA methods. Representatively, the existing recovery analysis does not specifically consider recovery actions as are occurred in actual nuclear power plants (NPPs). The overall goal of this study aims to develop a novel recovery analysis method to account for human action recoveries in context of scenarios as well as complement the limitations of existing recovery analysis. In this paper, the recovery analysis in current HRA methods and their challenges are introduced. A strategy to achieve the goal is introduced with a modified recovery definition. Then, how we have researched the approach will be introduced in the paper.

99 GENERAL AND MISCELLANEOUS↗