Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Development of satellite position location system for aircraft and boat distress beacons

An international satellite system for the detection and location of distress beacons carried on aircraft and vessels is in its technical checkout phase. User demonstration and evaluation (D&E) will start in early 1983 and continue for two years. The D&E phase and a subsequent transition period will form the basis for improved search and rescue operations for the 1980's and beyond. The system, called COSPAS/SARSAT, has international participation involving the U.S., Canada, and France as SARSAT members and joint participation with the Soviet Union's COSPAS Project. Norway and the U.K. have recently joined as investigators. Average position location error of the satellite aided processing is expected to be from 10-20KM for the existing 121.5/243 MHz distress beacons and from 2-5KM for experimental beacons transmitting in the 406 MHz band.

Kahle, D. R.↗

A GPS-Based Pitot-Static Calibration Method Using Global Output-Error Optimization

Pressure-based airspeed and altitude measurements for aircraft typically require calibration of the installed system to account for pressure sensing errors such as those due to local flow field effects. In some cases, calibration is used to meet requirements such as those specified in Federal Aviation Regulation Part 25. Several methods are used for in-flight pitot-static calibration including tower fly-by, pacer aircraft, and trailing cone methods. In the 1990 s, the introduction of satellite-based positioning systems to the civilian market enabled new inflight calibration methods based on accurate ground speed measurements provided by Global Positioning Systems (GPS). Use of GPS for airspeed calibration has many advantages such as accuracy, ease of portability (e.g. hand-held) and the flexibility of operating in airspace without the limitations of test range boundaries or ground telemetry support. The current research was motivated by the need for a rapid and statistically accurate method for in-flight calibration of pitot-static systems for remotely piloted, dynamically-scaled research aircraft. Current calibration methods were deemed not practical for this application because of confined test range size and limited flight time available for each sortie. A method was developed that uses high data rate measurements of static and total pressure, and GPSbased ground speed measurements to compute the pressure errors over a range of airspeed. The novel application of this approach is the use of system identification methods that rapidly compute optimal pressure error models with defined confidence intervals in nearreal time. This method has been demonstrated in flight tests and has shown 2- bounds of approximately 0.2 kts with an order of magnitude reduction in test time over other methods. As part of this experiment, a unique database of wind measurements was acquired concurrently with the flight experiments, for the purpose of experimental validation of the optimization method. This paper describes the GPS-based pitot-static calibration method developed for the AirSTAR research test-bed operated as part of the Integrated Resilient Aircraft Controls (IRAC) project in the NASA Aviation Safety Program (AvSP). A description of the method will be provided and results from recent flight tests will be shown to illustrate the performance and advantages of this approach. Discussion of maneuver requirements and data reduction will be included as well as potential applications.

Foster, John V.↗

Methods and Apparatus for Reducing Multipath Signal Error Using Deconvolution

A deconvolution approach to adaptive signal processing has been applied to the elimination of signal multipath errors as embodied in one preferred embodiment in a global positioning system receiver. The method and receiver of the present invention estimates then compensates for multipath effects in a comprehensive manner. Application of deconvolution, along with other adaptive identification and estimation techniques, results in completely novel GPS (Global Positioning System) receiver architecture.

Kumar, Rajendra↗

Precise GPS orbit determination results from 1985 field tests

Data from three different receiver types have been used to obtain precise orbits for the satellites of the Global Positioning System (GPS). The data were collected during the 1985 March-April GPS experiment to test and validate GPS techniques for precision orbit determination and geodesy. A new software package developed at the Jet Propulsion Laboratory (JPL), GIPSY (GPS Inferred Positioning SYstem), was used to process the data. To assess orbit accuracy, solutions are compared using integrated doppler data from various different receiver types, different fiducial sites, and independent data arcs, including one spanning six days. From these intercomparisons, orbit accuracy for a well-tracked GPS satellite of three meters in altitude and about five meters in each of down and cross-track components are inferred.

Lichten, S. M.↗

Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system

Purpose: Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. Methods: In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion data that were used subsequently to correct the position and phase of recorded k-space samples. Motion data can be acquired with a temporal resolution of 60 Hz and spatial accuracy of 0.1 mm for translations and 0.2 deg. for rotations. Results: Significant improvements of image quality are demonstrated. Conclusions: The key advantages of the technique are that it is easy to implement, does not interfere with or complicate MR data acquisition, and is capable of correcting distortions within a single slice. Therefore, the technique has the potential to improve upon approaches that rely on the registration or realignment of successive imaging slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effects of air leaks on solar air heating systems

This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

Elkin, R.↗

Engineering microscale systems for fully autonomous intracellular neural interfaces

Conventional electrodes and associated positioning systems for intracellular recording from single neurons in vitro and in vivo are large and bulky, which has largely limited their scalability. Further, acquiring successful intracellular recordings is very tedious, requiring a high degree of skill not readily achieved in a typical laboratory. We report here a robotic, MEMS-based intracellular recording system to overcome the above limitations associated with form-factor, scalability and highly skilled and tedious manual operations required for intracellular recordings. This system combines three distinct technologies: 1) novel microscale, glass-polysilicon penetrating electrode for intracellular recording, 2) electrothermal microactuators for precise microscale movement of each electrode and 3) closed-loop control algorithm for autonomous positioning of electrode inside single neurons. Here, we demonstrate the novel, fully integrated system of glass-polysilicon microelectrode, microscale actuators and controller for autonomous intracellular recordings from single neurons in the abdominal ganglion of Aplysia Californica (n = 5 cells). Consistent resting potentials (< –35 mV) and action potentials (> 60 mV) were recorded after each successful penetration attempt with the controller and microactuated glass-polysilicon microelectrodes. The success rate of penetration and quality of intracellular recordings achieved using electrothermal microactuators were comparable to that of conventional positioning systems. The MEMS-based system offers significant advantages: 1) reduction in overall size for potential use in behaving animals, 2) scalable approach to potentially realize multi-channel recordings and 3) a viable method to fully automate measurement of intracellular recordings. Furthermore, this system will be evaluated in vivo in future rodent studies.

42 ENGINEERING↗

Investigation of air transportation technology at Ohio University, 1986

Several important goals were achieved with the work supported by the Joint University Program. Among these goals is the first DC-3 flight with a Navstar Global Positioning System (GPS) receiver collecting positional data and allowing comparisons with simultaneous collected data from the Long Range Navigation system Loran C. The principle purpose for this instrumentation was to learn of the detailed characteristics evident in the Doppler frequency shift from signals being received onboard an aircraft in flight.

Mcfarland, Richard H.↗

Neutral gas temperature estimates and metastable resonance energy transfer for argon-nitrogen discharges

Rovibrational spectroscopy band fitting of the nitrogen (N{sub 2}) second positive system is a technique used to estimate the neutral gas temperature of N{sub 2} discharges, or atomic discharges with trace amounts of a N{sub 2} added. For mixtures involving argon and N{sub 2}, resonant energy transfer between argon metastable atoms (Ar*) and N{sub 2} molecules may affect gas temperature estimates made using the second positive system. The effect of Ar* resonance energy transfer is investigated here by analyzing neutral gas temperatures of argon-N{sub 2} mixtures, for N{sub 2} percentages from 1% to 100%. Neutral gas temperature estimates are higher than expected for mixtures involving greater than 5% N{sub 2} addition, but are reasonable for argon with less than 5% N{sub 2} addition when compared with an analytic model for ion-neutral charge exchange collisional heating. Additional spatiotemporal investigations into neutral gas temperature estimates with 10% N{sub 2} addition demonstrate that although absolute temperature values may be affected by Ar* resonant energy transfer, spatiotemporal trends may still be used to accurately diagnose the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defining the Environmental Adaptations of Genus Devosia: Insights into its Expansive Short Peptide Transport System and Positively Selected Genes

Devosia are well known for their dominance in soil habitats contaminated with various toxins and are best characterized for their bioremediation potential. In this study, we compared the genomes of 27 strains of Devosia with aim to understand their metabolic abilities. The analysis revealed their adaptive gene repertoire which was bared from 52% unique pan-gene content. A striking feature of all genomes was the abundance of oligo- and di-peptide permeases (oppABCDF and dppABCDF) with each genome harboring an average of 60.7±19.1 and 36.5±10.6 operon associated genes respectively. Apart from their primary role in nutrition, these permeases may help Devosia to sense environmental signals and in chemotaxis at stressed habitats. Through sequence similarity network analyses, we identified 29 Opp and 19 Dpp sequences that shared very little homology with any other sequence suggesting an expansive short peptidic transport system within Devosia. The substrate determining components of these permeases viz. OppA and DppA further displayed a large diversity that separated into 12 and 9 homologous clusters respectively in addition to large number of isolated nodes. We also dissected the genome scale positive evolution and found genes associated with growth (exopolyphosphatase, HesB_IscA_SufA family protein), detoxification (moeB, nifU-like domain protein, alpha/beta hydrolase), chemotaxis (cheB, luxR) and stress response (phoQ, uspA, luxR, sufE) were positively selected. The study highlights the genomic plasticity of the Devosia spp. for conferring adaptation, bioremediation and the potential to utilize a wide range of substrates. The widespread toxin-antitoxin loci and ‘open’ state of the pangenome provided evidence of plastic genomes and a much larger genetic repertoire of the genus which is yet uncovered.

59 BASIC BIOLOGICAL SCIENCES↗

An Overview of Flight Test Results for a Formation Flight Autopilot

The first flight test phase of the NASA Dryden Flight Research Center Autonomous Formation Flight project has successfully demonstrated precision autonomous station-keeping of an F/A-18 research airplane with a second F/A-18 airplane. Blended inertial navigation system (INS) and global positioning system (GPS) measurements have been communicated across an air-to-air telemetry link and used to compute relative-position estimates. A precision research formation autopilot onboard the trailing airplane controls lateral and vertical spacing while the leading airplane operates under production autopilot control. Four research autopilot gain sets have been designed and flight-tested, and each exceeds the project design requirement of steady-state tracking accuracy within 1 standard deviation of 10 ft. Performance also has been demonstrated using single- and multiple-axis inputs such as step commands and frequency sweeps. This report briefly describes the experimental formation flight systems employed and discusses the navigation, guidance, and control algorithms that have been flight-tested. An overview of the flight test results of the formation autopilot during steady-state tracking and maneuvering flight is presented.

Curtis E Hanson↗

GOES-R Series GEO Side-Lobe Capable GPSR Post-Launch Refinements and Operational Capabilities

This paper addresses three topics: 1) EOPP (EOP (Earth Orientation Prediction) Parameters) file modification, 2) Kalman filter parameter tuning regarding maneuvers and 3) off-pointing GPS (Global Positioning System) tracking capability. GOES-R (Geostationary Operational Environmental Satellite-R Series) is the first in a 4-part series of new weather satellites set to replace and upgrade the older GOES constellation. Two GOES-R series have been launched to date, GOES-S and GOES-R. GOES-R is operational over the Eastern United States and GOES-S over the West. The Global Positioning System Receiver (GPSR) on board this geostationary weather satellite is a mission critical enabling technology which has been both tested on the ground and evaluated on-orbit to verify its effectivity. Since becoming operational in November 2016, the GPSR onboard has performed extremely well under nominal circumstances. Further refinements regarding a variety of facets have taken place since the launch of GOES-R. One such refinement was the implementation of a modified EOP (Earth Orientation Prediction) parameter set to improve ECEF (Earth Centered Earth Fixed) to ECI (Earth Centered Inertial) transformation by restoring zonal tides removed from the EOP parameter fit per tech note 36. Another relevant refinement combined thermal consideration with Kalman filter tuning to improve orbit determination performance during maneuvers. Now with two years of data and two vehicles in orbit many capabilities of the GPSR have been identified and defined to a higher degree. For example, metrics on side-lobe tracking and off-Nadir tracking capabilities have been quantified to a high degree. This paper will seek to supplement the ESA (European Space Agency) GNC 2017 GOES-R GPSR performance paper as a deeper dive on specific tracking capabilities and performance improvements now implemented on the GOES-R and GOES-S vehicles.

GPS Receiver↗

Efimov effect for heteronuclear three-body systems at positive scattering length and finite temperature

Here, we study the recombination process of three atoms scattering into an atom and diatomic molecule in heteronuclear mixtures of ultracold atomic gases with large and positive interspecies scattering length at finite temperature. We calculate the temperature dependence of the three-body recombination rates by extracting universal scaling functions that parametrize the energy dependence of the scattering matrix. We compare our results to experimental data for the 40 K– 87 Rb mixture and make a prediction for 6 Li– 87 Rb. We find that contributions from higher partial wave channels significantly impact the total rate and, in systems with particularly large mass imbalance, can even obliterate the recombination minima associated with the Efimov effect.

74 ATOMIC AND MOLECULAR PHYSICS↗

Demonstration of the fiducial concept using data from the March 1985 GPS field test

The first field test of NASA's Global Positioning System (GPS) Geodetic Program took place in March of 1985. The principal objective of this test was the demonstration of the feasibility of the fiducial station approach to precise GPS-based geodesy and orbit determination. Other objectives included an assessment of the performance of the several GPS receiver types involved in these field tests and the testing of the GIPSY software for GPS data analysis. In this article, the GIPSY (GPS Inferred Positioning System) software system is described and baseline solutions are examined for consistency with independent measurements made using very long baseline interferometry.

Davidson, J. M.↗

Langmuir probe diagnostics of electron energy distributions with optical emission spectroscopy in capacitively coupled rf discharge in nitrogen

Measurements with a rf compensated Langmuir probe and optical emission spectroscopy are carried out in capacitively coupled rf (13.56 MHz) pure nitrogen N{sub 2} discharges at fixed rf voltage over a wide range of pressure, 30 to 400 mTorr. The electron energy probability function (EEPF) measured below 100 mTorr resembles a bi-Maxwellian-type distribution. At pressure range of 100-200 mTorr, the EEPF has non-Maxwellian distribution with a ''dip'' near 4.5 eV. At the highest pressure of 400 mTorr, the EEPF evolves into a Druyvestein-like distribution and the ''dip'' disappears. The electron density significantly decreases with increase in the N{sub 2} pressure. On the other hand, the electron temperatures gradually decrease with an increase in N{sub 2} pressure, reaching minimum at 150 mTorr, beyond which it abruptly increases. Such evolution of the EEPFs shape with gas pressure has been discussed in terms of non-local electron kinetics and heating mode transition. The emission intensities of nitrogen (0-0) band of second positive system at 337.1 nm and (0-0) band of first negative systems at 391.4 nm are used to determine the dependence of their radiative states N{sub 2}(C{sup 3}{Pi}{sub u}) and N{sub 2}{sup +}(B{sup 2}{Sigma}{sub u}{sup +}) with nitrogen pressure. It is observed that the pressure influences the radiative states differently owing to their different populating mechanisms. The vibrational temperature T{sub {nu}ib} and rotational temperature T{sub rot} are measured for the sequence ({Delta}{nu}=-2) of N{sub 2} second positive system (C{sup 3}{Pi}{yields}B{sup 3}{Pi}{sub g}) using the method of comparing the measured and calculated spectra with a chi-squared minimization procedure. It was found that both T{sub {nu}ib} and T{sub rot} have similar dependences with N{sub 2} pressure; peaked at 100 mTorr beyond which it monotonically decreases with increase in the N{sub 2} pressure. The correlation between the observed maximum value of T{sub {nu}ib} around 100 mTorr and the detected ''dip'' in the EEPF in the same pressure range has been discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orion MPCV GN and C End-to-End Phasing Tests

End-to-end integration tests are critical risk reduction efforts for any complex vehicle. Phasing tests are an end-to-end integrated test that validates system directional phasing (polarity) from sensor measurement through software algorithms to end effector response. Phasing tests are typically performed on a fully integrated and assembled flight vehicle where sensors are stimulated by moving the vehicle and the effectors are observed for proper polarity. Orion Multi-Purpose Crew Vehicle (MPCV) Pad Abort 1 (PA-1) Phasing Test was conducted from inertial measurement to Launch Abort System (LAS). Orion Exploration Flight Test 1 (EFT-1) has two end-to-end phasing tests planned. The first test from inertial measurement to Crew Module (CM) reaction control system thrusters uses navigation and flight control system software algorithms to process commands. The second test from inertial measurement to CM S-Band Phased Array Antenna (PAA) uses navigation and communication system software algorithms to process commands. Future Orion flights include Ascent Abort Flight Test 2 (AA-2) and Exploration Mission 1 (EM-1). These flights will include additional or updated sensors, software algorithms and effectors. This paper will explore the implementation of end-to-end phasing tests on a flight vehicle which has many constraints, trade-offs and compromises. Orion PA-1 Phasing Test was conducted at White Sands Missile Range (WSMR) from March 4-6, 2010. This test decreased the risk of mission failure by demonstrating proper flight control system polarity. Demonstration was achieved by stimulating the primary navigation sensor, processing sensor data to commands and viewing propulsion response. PA-1 primary navigation sensor was a Space Integrated Inertial Navigation System (INS) and Global Positioning System (GPS) (SIGI) which has onboard processing, INS (3 accelerometers and 3 rate gyros) and no GPS receiver. SIGI data was processed by GN&C software into thrust magnitude and direction commands. The processing changes through three phases of powered flight: pitchover, downrange and reorientation. The primary inputs to GN&C are attitude position, attitude rates, angle of attack (AOA) and angle of sideslip (AOS). Pitch and yaw attitude and attitude rate responses were verified by using a flight spare SIGI mounted to a 2-axis rate table. AOA and AOS responses were verified by using a data recorded from SIGI movements on a robotic arm located at NASA Johnson Space Center. The data was consolidated and used in an open-loop data input to the SIGI. Propulsion was the Launch Abort System (LAS) Attitude Control Motor (ACM) which consisted of a solid motor with 8 nozzles. Each nozzle has active thrust control by varying throat area with a pintle. LAS ACM pintles are observable through optically transparent nozzle covers. SIGI movements on robot arm, SIGI rate table movements and LAS ACM pintle responses were video recorded as test artifacts for analysis and evaluation. The PA-1 Phasing Test design was determined based on test performance requirements, operational restrictions and EGSE capabilities. This development progressed during different stages. For convenience these development stages are initial, working group, tiger team, Engineering Review Team (ERT) and final.

Neumann, Brian C.↗

Optical emission characteristics of medium- to high-pressure N{sub 2} dielectric barrier discharge plasmas during surface modification of polymers

The authors measured the band spectra (first and second positive systems) of the nitrogen molecule by optical emission spectroscopy with an aim to understand the mechanism of surface processing by medium- to high-pressure dielectric barrier discharge (DBD) plasmas. The experimentally measured and calculated spectra were compared to determine the vibrational and rotational temperatures of the N{sub 2} (C{sup 3}{Pi}{sub u}) state in the generated plasmas. The authors generated the N{sub 2} DBD plasmas at a driving frequency of 1-7 kHz and a discharge pressure of 20-10{sup 5} Pa for the surface modification of a polyethylene terephthalate (PET) sample. It was found that the vibrational temperature was greatly affected by the N{sub 2} pressure while the rotational temperature remained constant in the N{sub 2} pressure range of 20-10{sup 5} Pa. The emission intensity of N{sub 2} first positive system (B{sup 3}{Pi}{yields}A{sup 3}{Sigma}) rapidly decreased at an increasing N{sub 2} pressure due to the collisional relaxation process of the B{sup 3}{Pi} state with N{sub 2} molecules. The N{sub 2}{sup +}(B{sup 2}{Sigma}{sub u}{sup +}{yields}X{sup 2}{Sigma}{sub g}{sup +}) radiative transition was observed in the low-pressure DBD plasmas, which was attributed to the direct electron impact ionization of N{sub 2} molecules. The surface characterizations of treated PET samples by contact angle measurement and atomic force microscopy indicate that the low-pressure N{sub 2} DBD plasma is an effective method for the surface modification of polymers. Analysis indicates the plasma characteristics such as electron temperature and ion energy are mainly dependent on the N{sub 2} pressure, which turn to determine the surface properties of treated PET samples.

36 MATERIALS SCIENCE↗