Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Retrieving Aerosol Characteristics From the PACE Mission, Part 2: Multi-Angle and Polarimetry

The Plankton, Aerosol, Clouds, ocean Ecosystem (PACE) mission presents new opportunities and new challenges in applying observations of two complementary multi-angle polarimeters for the space-based retrieval of global aerosol properties.Aerosol remote sensing from multi-angle radiometric-only observations enables aerosol characterization to a greater degree than single-view radiometers, as demonstrated by nearly two decades of heritage instruments. Adding polarimetry to the multi-angle observations allows for the retrieval of aerosol optical depth, Angstrom exponent,parameters of size distribution, measures of aerosol absorption, complex refractive index and degree of non-sphericity of the particles, as demonstrated by two independent retrieval algorithms applied to the heritage POLarization and Directionality of the Earth's Reflectance (POLDER) instrument. The reason why this detailed particle characterization is possible is because a multi-angle polarimeter measurement contains twice the number of Degrees of Freedom of Signal (DFS) compared to an observation from a single-view radiometer. The challenges of making use of this information content involve separating surface signal from atmospheric signal, especially when the surface is optically complex and especially in the ultraviolet portion of the spectrum where we show the necessity of polarization in making that separation. The path forward is likely to involve joint retrievalsthat will simultaneously retrieve aerosol and surface properties, although advances will berequired in radiative transfer modeling and in representing optically complex constituents in those models. Another challenge is in having the processing capability that can keep pace with the output of these instruments in an operational environment. Yet, preliminaryalgorithms applied to airborne multi-angle polarimeter observations offer encouraging results that demonstrate the advantages of these instruments to retrieve aerosol layer height, particle single scattering albedo, size distribution and spectral optical depth, and also show the necessity of polarization measurements, not just multi-angle radiometricmeasurements, to achieve these results.

Remer, Lorraine A.↗

XL-Calibur - a second-generation balloon-borne hard X-ray polarimetry mission

XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301−2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprising a beryllium rod surrounded by Cadmium Zinc Telluride (CZT) detectors. The polarimeter is housed in an anticoincidence shield to mitigate background from particles present in the stratosphere. The mirror and polarimeter-shield assembly are mounted at opposite ends of a12 m long lightweight truss, which is pointed with arcsecond precision by WASP – the Wallops Arc Second Pointer. TheXL-Calibur mission will achieve a substantially improved sensitivity over X-Caliburby using a larger effective area X-ray mirror, reducing background through thinner CZT detectors, and improved anticoincidence shielding. When observing a 1 Crab source for t(day) days, the Minimum Detectable Polarisation (at 99% confidence level) is∼2%·t−1/2day. The energy resolution at 40 keV is∼5.9 keV. The aim of this paper is to describe the design and performance of the XL-Calibur mission, as well as the foreseen science programme.

Q Abarr↗

The PACE-MAPP Polarized Ocean Bio-optical Model

The MAPP polarimeter retrieval algorithm, originally developed for the airborne NASA GISS Research Scanning Polarimeter, is being adapted to the PACE observing system to allow for a simultaneous retrieval of aerosol, thin cirrus, and ocean products using both PACE polarimeters and the OCI shortwave infrared channels. Here, we describe the polarized ocean bio-optical model we have developed for PACE-MAPP, which is designed to use a combination of homogenous and coated spheres to more accurately model the absorption and backscattering properties of algal and non-algal particles, and which also includes absorption by colored dissolved organic matter. We first use Lorenz-Mie computations to create lookup tables to accurately and efficiently characterize the optical properties of homogeneous and coated spheres embedded in water for PACE. We then use these lookup tables to develop a bio-optical model that consists of an external mixture of homogeneous (non-algal) and coated (algal) spheres. Lastly, we use the bio-optical model in forward radiative transfer computations to perform inversions of MODIS remote sensing reflectance for a variety of ocean regions. We explore the sensitivity of these inversions to ocean constituent inherent optical properties.

James Allen↗

Mission Overview and Status IGARSS Conference

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a strategic climate continuity mission that was defined in the 2010 document Responding to the Challenge of Climate and Environmental Change: NASA’s Plan for Climate-Centric Architecture for Earth Observations and Applications from Space (referred to as the “Climate Initiative”). Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. PACE will extend the high quality ocean ecological, ocean biogeochemical, cloud, and aerosol particle data records begun by NASA in the 1990s, building on the exceptional heritages of the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS), the Moderate Resolution Imaging Spectroradiometer (MODIS), the Multi-angle Imaging SpectroRadiometer (MISR), and the Visible Infrared Imaging Radiometer Suite (VIIRS). The PACE project office at NASA’s GSFC is responsible for the satellite development, launch and operations. The NASA Headquarters PACE Program Science office is responsible for supporting the science data processing system and assembling competed community science teams, which will include field-based vicarious calibration and data product validation efforts to support the PACE Project Science team. The mission is planned for launch into a Sun synchronous polar orbit at 676.5 km with an inclination of 98 degrees and a 1 pm local ascending node crossing time. The PACE observatory is comprised of three instruments, an Ocean Color Instrument (OCI) and two polarimeters, the Hyper-Angular Rainbow Polarimeter 2 (HARP2) and the Spectro-Polarimeter for Exploration (SPEXone). The OCI is the primary instrument on the observatory and is being developed at Goddard Space Flight Center (GSFC). The OCI is a hyperspectral scanning radiometer designed to measure spectral radiances from the ultraviolet to shortwave infrared (SWIR) to enable advanced ocean color and heritage cloud and atmospheric aerosol science [2]. The HARP2 and SPEXone are complimentary instruments on the PACE observatory, acquired outside of GSFC. The HARP2 is multi-spectral, wide swath (supporting atmospheric correction of OCI), and hyper-angular, with capabilities for cloud science that exceed what is capable from OCI alone. The SPEXone is narrow swath, multi-angular, and hyperspectral, with capabilities for atmospheric aerosol science that exceed what can be accomplished with OCI. NASA Headquarters directed the mission development to be guided by a Design-to-Cost (DTC) process. All elements of the mission, other than the cost, are in the DTC trade space. At the heart of the DTC process are the mission studies, performed across all the mission elements. The mission studies were used to define appropriate approaches within and across elements while maximizing science capabilities at a high cost confidence. Mission baseline requirements development is also embedded within the DTC process, as these requirements were not established at the onset of the mission concept development. Baseline mission requirements are a product of the mission studies and are defined by the project office as part of the DTC process. At the time of this writing, OCI, HARP2 and SPEXone are integrated onto the PACE spacecraft, creating the PACE observatory. The instruments and spacecraft subsystems are undergoing combined functional performance testing in preparation for observatory-level environmental testing prior to shipment to the launch site. Here, we will provide an update on science capabilities and observatory readiness for its early 2024 launch.

remote sensing↗

High Precision Polarization Strategy for the Q$_{weak}$ Experiment

The Q$_{weak}$ experiment in Hall C at Jefferson Lab is measuring the weak charge of the proton to an uncertainty of 4.1\% by scattering longitudinally polarized electrons from protons in a liquid hydrogen target. The electron beam polarization is budgeted as the largest experimental systematic uncertainty of 1.5\%. Aiming for a polarization measurement to within 1\%, two independent polarimeters monitored the beam polarization by measuring the asymmetry of the polarized electron beam scattering either via the M\o ller or Compton process. The M\o ller polarimeter detects the pair of electrons scattered from a highly polarized thin iron foil through two identical calorimeters. However, it was limited to running at much lower currents and measurements are invasive to the experiment. The Compton polarimeter was commissioned to remove this limitation by using a high powered Fabry-P\'erot cavity laser to provide a polarized photon source. The use of Compton scattering allows for non-invasive measurements and the ability to run at the same currents as the main experiment. The Compton scattered photons and electrons are detected independently. I will discuss the polarimetry strategy and preliminary polarization results for the Q$_{weak}$ experiment using these three techniques.

Cornejo, Juan↗

Accurate, low-energy Compton polarimetry for Hall C at Jefferson Lab

A new Compton polarimeter has recently been commissioned in Hall C at Jefferson Lab in Newport News, VA, to provide a non-invasive, continuous measurement of electron beam polarization. The new Compton polarimeter is currently measuring electron beam polarization for Qweak, an experiment with a strict error budget allowing a combined statistical and systematic error of only $\pm1\%$ for beam polarization. Using well-established techniques we are able to determine electron beam polarization by measuring the scattering asymmetry of both the backscattered photons and the scattered electrons. Although the photon and electron detectors provide somewhat independent measurements they share the common systematic of the laser polarization. I discuss the optical setup for the photon target used in the Compton polarimeter and recent efforts in reducing systematic error in determination of laser polarization.

Jones, Donald↗

Electron polarimetry at low energies in Hall C at JLab

Although the majority of Jefferson Lab experiments require multi-GeV electron beams, there have been a few opportunities to make electron beam polarization measurements at rather low energies. This proceedings will discuss some of the practical difficulties encountered in performing electron polarimetry via Mo/ller scattering at energies on the order of a few hundred MeV. Prospects for Compton polarimetry at very low energies will also be discussed. While Mo/ller scattering is likely the preferred method for electron polarimetry at energies below 500 MeV, there are certain aspects of the polarimeter and experiment design that must be carefully considered.

43 PARTICLE ACCELERATORS↗

Study of ablation and implosion stages in wire arrays using coupled ultraviolet and X-ray probing diagnostics

Star and cylindrical wire arrays were studied using laser probing and X-ray radiography at the 1-MA Zebra pulse power generator at the University of Nevada, Reno. The Leopard laser provided backlighting, producing a laser plasma from a Si target which emitted an X-ray probing pulse at the wavelength of 6.65 Å. A spherically bent quartz crystal imaged the backlit wires onto X-ray film. Laser probing diagnostics at the wavelength of 266 nm included a 3-channel polarimeter for Faraday rotation diagnostic and two-frame laser interferometry with two shearing interferometers to study the evolution of the plasma electron density at the ablation and implosion stages. Dynamics of the plasma density profile in Al wire arrays at the ablation stage were directly studied with interferometry, and expansion of wire cores was measured with X-ray radiography. The magnetic field in the imploding plasma was measured with the Faraday rotation diagnostic, and current was reconstructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface BRDF estimation from an aircraft compared to MODIS and ground estimates at the Southern Great Plains site

The surface spectral albedo is an important component of climate models since it determines the amount of incident solar radiation that is absorbed by the ground. The albedo can be highly heterogeneous, both in space and time, and thus adequate measurement and modeling is challenging. One source of measurements that constrain the surface albedo are satellite instruments that observe the Earth, such as the Moderate Resolution Imaging Spectroradiometer (MODIS). Satellites estimate the surface bidirectional reflectance distribution function (BRDF) by correcting top of the atmosphere (TOA) radiances for atmospheric effects and accumulating observations at a variety of viewing geometries. The BRDF can then be used to determine the albedo that is required in climate modeling. Other measurements that provide a more direct constraint on surface albedo are those made by upward and downward looking radiometers at the ground. One product in particular, the Best Estimate Radiation Flux (BEFLUX) value added product of the Department of Energy’s Atmospheric Radiation Measurement (ARM) Program at the Southern Great Plains Central Facility (SGP CF) in central Oklahoma, has been used to evaluate the quality of the albedo products derived from MODIS BRDF estimates. These comparisons have highlighted discrepancies between the energy absorbed at the surface that is calculated from the BEFLUX products and that is predicted from the MODIS BRDF product. This paper attempts to investigate these discrepancies by using data from an airborne scanning radiometer, the Research Scanning Polarimeter (RSP) that was flown at low altitude in the vicinity of the SGP CF site during the Aerosol Lidar Validation Experiment (ALIVE) in September of 2005. The RSP is a polarimeter that scans in the direction of the aircraft ground track, and can thus estimate the BRDF in a period of seconds, rather than the days required by MODIS to accumulate enough viewing angles. Atmospheric correction is aided by the Ames Airborne Tracking Sunphotometer (AATS-14), which was operated on the same aircraft as the RSP. The RSP data can therefore be used to validate the MODIS BRDF product and diagnose the reason for the discrepancies with BEFLUX. Our analysis indicates that MODIS and RSP estimates of surface absorption and BEFLUX measurements do agree and that previously noticed differences between MODIS albedo products and BEFLUX were due as much to the analysis techniques used as to any instrumental effects. We conclude that the MODIS BRDF products provide a useful measure of surface albedo that can be used to determine whether the surface radiative heating in climate models has a realistic spatial and seasonal variation.

54 ENVIRONMENTAL SCIENCES↗

Towards High Precision Deuteron Polarimetry

A finite electric dipole moment (EDM) in any fundamental system would constitute a signal for new physics. The deuteron presents itself as an optimal candidate both experimentally and theoretically. A new storage ring technique is being developed for which a small change in the vertical polarization would be a signal of a non-zero EDM. A novel polarimeter concept is under investigation. Besides being highly efficient, this polarimeter should continuously monitor the beam polarization, guaranteeing optimal sensitivity. Detailed studies on systematic error control, in addition to the measurement of cross sections and analyzing powers, were carried out at KVI-Groningen in The Netherlands. Measurements were conducted at COSY-Juelich in Germany yielding high efficiencies. The (statistics limited) ability to track changes in polarization at the level of a few hundred parts-per-million has been demonstrated. Further studies and developments to meet the final goal of sub-part-per-million sensitivity are in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards Improved Proton Polarimetry at RHIC

The RHIC polarized proton collider polarimeters employ the analyzing power in p-Carbon elastic scattering in the Coulomb Nuclear Interference region to measure the proton beam polarization. These are calibrated by the polarized hydrogen jet target that measures the absolute beam polarization utilizing the pp elastic scattering process in the CNI region. This paper describes the status of these polarimeters and the efforts employed to improve the performance in terms of better resolution, rate handling capability, and reduced systematic uncertainties.

43 PARTICLE ACCELERATORS↗

Stokes polarimetry using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders

We present a method for using liquid-crystal variable retarders (LCVR’s) with continually varying voltage to measure the Stokes vector of a light beam. The LCVR's are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. The nonlinear voltage-retardance relationship is first measured and then a linear fit of the known retardance terms to the detected signal is performed. We use known waveplates (half-wave and quarter-wave) as devices to provide controlled polarization states to the Stokes polarimeter and we use the measured Stokes parameters as functions of the orientation of the axes of the waveplates as an indication of the quality of the polarimeter. Results are compared to a Fourier analysis method that does not take into account the nonlinear voltage-retardance relationship and also to a Fourier analysis method that uses experimental voltage values to give a linear retardance function with time. Also, we present results of simulations for comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of neutral-beam-aided diagnostics on the HL-2A tokamak

A 32/64-channel Charge eXchange Recombination Spectroscopy (CXRS) and a 7-channel motional Stark effect (MSE) polarimeter have been developed on the HL-2A tokamak. To extract the maximum time resolution of the system, the incidence fibers of the spectrometer are pitch-controlled; and the double-slit fiber bundle can increase the spatial channels with one charge-coupled device detector. The ion temperature and plasma rotation with time and spatial resolutions up to 5 ms and 1 cm are obtained. Sawtooth oscillation, transition from intermediate phase (I phase) to high confinement mode (H mode) can be clearly observed by the CXRS. The spectrometer can be utilized as the main component of the MSE polarimeter, which can effectively overcome the weak Stark effect. The pitch angles of magnetic field are obtained for 7 spatial points covering 24 cm along major radius with time resolution of 40 ms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam

A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metis aboard the Solar Orbiter space mission: Doses from galactic cosmic rays and solar energetic particles

The aim of this work is to calculate the dose released by galactic cosmic rays (GCRs) and solar energetic particles (SEPs) in the polarimeter of the Multi Element Telescope for Imaging and Spectroscopy (METIS) coronagraph [1] aboard the Solar Orbiter. This investigation is performed with a Monte Carlo method by considering the role of SEP events of proper intensity at a heliocentric distance from the Sun averaged along the spacecraft orbit. Our approach can be extended to other space missions reaching short distances from the Sun, such as Solar Probe Plus. This study indicates that the deposited dose on the whole set of polarimeter lenses and filters during ten years of the Solar Orbiter mission is of about 2000 Gy. For cerium treated lenses, a dose of 10{sup 6} Gy of gamma radiation from a {sup 60}Co source causes a few percent transmittance loss.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CdTe Timepix detectors for single-photon spectroscopy and linear polarimetry of high-flux hard x-ray radiation

Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays — such as laser-generated plasmas — is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STATISTICAL PROPERTIES OF GAMMA-RAY BURST POLARIZATION

The emission mechanism and the origin and structure of magnetic fields in gamma-ray burst (GRB) jets are among the most important open questions concerning the nature of the central engine of GRBs. In spite of extensive observational efforts, these questions remain to be answered and are difficult or even impossible to infer with the spectral and light-curve information currently collected. Polarization measurements will lead to unambiguous answers to several of these questions. Recent developments in X-ray and {gamma}-ray polarimetry techniques have demonstrated a significant increase in sensitivity, enabling several new mission concepts, e.g., Polarimeters for Energetic Transients (POET), providing wide field of view and broadband polarimetry measurements. If launched, missions of this kind would finally provide definitive measurements of GRB polarizations. We perform Monte Carlo simulations to derive the distribution of GRB polarizations in three emission models; the synchrotron model with a globally ordered magnetic field (SO model), the synchrotron model with a small-scale random magnetic field (SR model), and the Compton drag model (CD model). The results show that POET, or other polarimeters with similar capabilities, can constrain the GRB emission models by using the statistical properties of GRB polarizations. In particular, the ratio of the number of GRBs for which the polarization degrees can be measured to the number of GRBs that are detected (N{sub m} /N{sub d} ) and the distributions of the polarization degrees ({pi}) can be used as the criteria. If N{sub m} /N{sub d} > 30% and {pi} is clustered between 0.2 and 0.7, the SO model will be favored. If, instead, N{sub m} /N{sub d} < 15%, then the SR or CD model will be favored. If several events with {pi}>0.8 are observed, then the CD model will be favored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗