Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Improving radiograph analysis throughput through transfer learning and object detection

SIGN Fracture Care International partners with surgeons in low-resource hospitals worldwide to provide access to effective orthopedic care by donating educational materials and innovatively designed surgical implants. Over two decades, SIGN’s Online Surgical Database (SOSD) has grown to contain over 500,000 medical images, with radiographs holding the majority share. One challenge in working with hospitals worldwide is that both the radiographs uploaded to the SOSD and the data entry accompanying the uploads vary in quality. To improve the accuracy of data in the SOSD, we trained a model to detect surgical implants in radiographs. We first developed a tool to automatically detect radiographs, then trained an object detection model to determine the number and placement of surgical implants visible in the radiograph. Active learning was used to generate a training set containing 2,510 radiographs with screws, nails, and plates labeled by bounding boxes. Training a model to simultaneously recognize all three classes of implants gave a low average precision (AP) for the plate class, likely due to the low number of plate instances in our training set and the large variety of surgical plates used by SIGN-partnered surgeons. Applying standard image augmentation techniques to increase the plate count in our training set did not appreciably increase the AP of plate detection. To improve plate detection, we redrew the bounding boxes to account for correlations between the screw and plate classes. Training one model to detect nails and screws and a separate model to detect plates increased the AP of plate detection by 78.8 percentage points. The AP of each class was 80.7% for screws, 93.6% for nails, and 92.6% for plates; meanwhile, the sensitivity was 92% for screws, 86% for nails, and 81% for plates. We show that object detection methods can be used to detect surgical implants in radiographs of varying quality; however, the detection ability is dependent on the type of implant, and some implants, in our case plates, must be treated differently than others. Such tools can improve the throughput of radiograph analysis, assisting physicians and surgeons with the treatment of bone fractures.

60 APPLIED LIFE SCIENCES↗

Voltage-Based Strategies for Preventing Battery Degradation under Diverse Fast-Charging Conditions

Maintaining safe operating conditions is a key challenge for high-performance lithium-ion battery applications. The lithium-plating reaction remains a risk during charging, but limited studies consider the highly variable charging conditions possible in commercial cells. Here we combine pseudo-2D electrochemical modeling with data visualization methods to reveal important relationships between the measurable cell voltage and difficult-to-predict Li-plating onset criteria. An extensively validated model is used to compute Li plating for thousands of multistep charging conditions spanning diverse rates, temperatures, states-of-charge, and cell aging. Here we observe an empirical cell operating voltage limit below which plating does not occur across all conditions, and this limit varies with the battery state-of-charge and aging. A model sensitivity analysis also indicates that, when comparing two charging voltage profiles, the capacity difference at 4.0 V correlates well with the difference in the plating onset capacity. These results encourage simple strategies for Li-plating prevention that are complementary to existing battery controls.

25 ENERGY STORAGE↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

As-Built Simulation of the High Flux Isotope Reactor

The Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) is an 85 MWt flux trap-type research reactor that supports key research missions, including isotope production, materials irradiation, and neutron scattering. The core consists of an inner and an outer fuel element containing 171 and 369 involute-shaped plates, respectively. The thin fuel plates consist of a U 3 O 8 -Al dispersion fuel (highly enriched), an aluminum-based filler, and aluminum cladding. The fuel meat thickness is varied across the width of the involute plate to reduce thermal flux peaks at the radial edges of the fuel elements. Some deviation from the designed fuel meat shaping is allowed during manufacturing. A homogeneity scan of each fuel plate checks for potential anomalies in the fuel distribution by scanning the surface of the plate and comparing the attenuation of the beam to calibration standards. While typical HFIR simulations use homogenized fuel regions, explicit models of the plates were developed under the Low-Enriched Uranium Conversion Program. These explicit models typically include one inner and one outer fuel plate with nominal fuel distributions, and then the plates are duplicated to fill the space of the corresponding fuel element. Therefore, data extracted from these simulations are limited to azimuthally averaged quantities. To determine the reactivity and physics impacts of an as-built outer fuel element and generate azimuthally dependent data in the element, 369 unique fuel plate models were generated and positioned. This model generates the three-dimensional (i.e., radial–axial–azimuthal) plate power profile, where the azimuthal profile is impacted by features within the adjacent control element region and beryllium reflector. For an as-built model of the outer fuel element, plate-specific homogeneity data, 235 U loading, enrichment, and channel thickness measurements were translated into the model, yielding a much more varied azimuthal power profile encompassed by uncertainty factors in analyses. These models were run with the ORNL-TN and Shift Monte Carlo tools, and they contained upwards of 500,000 cells and 100,000 unique tallies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrolytes for iron flow battery

A method of operating an iron redox flow battery system may comprise fluidly coupling a plating electrode of an iron redox flow battery cell to a plating electrolyte; fluidly coupling a redox electrode of the iron redox flow battery cell to a redox electrolyte; fluidly coupling a ductile plating additive to one or both of the plating electrolyte and the redox electrolyte; and increasing an amount of the ductile plating additive to the plating electrolyte in response to an increase in the plating stress at the plating electrode. In this way, ductile Fe can be plated on the negative electrode, and the performance, reliability and efficiency of the iron redox flow battery can be maintained. In addition, iron can be more rapidly produced and plated at the plating electrode, thereby achieving a higher charging rate for all iron flow batteries.

25 ENERGY STORAGE↗