Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photovoltaic Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Printed Module Interconnects

Monolithic interconnects in photovoltaic modules connect adjacent cells in series, and are typically formed sequentially involving multiple deposition and scribing steps. Interconnect widths of 500 um every 10 mm result in 5% dead area, which does not contribute to power generation in an interconnected solar panel. This work expands on previous work that introduced an alternative interconnection method capable of producing interconnect widths less than 100 um. The interconnect is added to the module in a single step after deposition of the photovoltaic stack, eliminating the need for scribe alignment. This alternative method can be used for all types of thin film photovoltaic modules. Voltage addition with copper-indium-gallium-diselenide (CIGS) solar cells using a 2-scribe printed interconnect approach is demonstrated. Additionally, interconnect widths of 250 um are shown.

14 SOLAR ENERGY↗

Economic competitiveness of III-V on silicon tandem one-sun photovoltaic solar modules in favorable future scenarios

Here, tandem modules combining a III-V top cell with a Si bottom cell offer the potential to increase the solar energy conversion efficiency of one-sun photovoltaic modules beyond 25%, while fully utilizing the global investment that has been made in Si photovoltaics manufacturing. At present, the cost of III-V cells is far too high for this approach to be competitive for one-sun terrestrial power applications. We investigated the system-level economic benefits of both GaAs/Si and InGaP/Si tandem modules in favorable future scenarios where the cost of III-V cells is substantially reduced, perhaps to less than the cost of Si cells. We found, somewhat unexpectedly, that these tandems can reduce installed system cost only when the area-related balance-of-system cost is high, such as for area-constrained residential rooftop systems in the USA. When area-related balance-of-system cost is lower, such as for utility-scale systems, the tandem module offers no benefit. This is because a system using tandem modules is more expensive than one using single-junction Si modules when III-V cells are expensive, and a system using tandem modules is more expensive than one using single-junction III-V modules when III-V cells are inexpensive.

14 SOLAR ENERGY↗

Ensuring Quality of PV Modules: Preprint

Photovoltaic (PV) customers need to have confidence in the PV modules they purchase. Currently, no test can quantify a module's lifetime with confidence, but stress tests are routinely used to differentiate PV product designs. We suggest that the industry would be strengthened by using the wisdom of the community to develop a single set of tests that will help customers quantify confidence in PVproducts. This paper evaluates the need for quality assurance (QA) standards and suggests a path for creating these. Two types of standards are needed: 1) QA of the module design and 2) QA of the manufacturing process.

14 SOLAR ENERGY↗

Customized color patterning of photovoltaic cells

Photovoltaic cells and photovoltaic modules, as well as methods of making and using such photovoltaic cells and photovoltaic modules, are disclosed. More particularly, embodiments of the photovoltaic cells selectively reflect visible light to provide the photovoltaic cells with a colorized appearance. Photovoltaic modules combining colorized photovoltaic cells may be used to harvest solar energy while providing a customized appearance, e.g., an image or pattern.

14 SOLAR ENERGY↗

Developments for Novel Module Architecture for Lower CapEx and Improved Recyclability for c-Si PV Modules

Photovoltaic (PV) energy production is currently increasing at a significant rate. A novel module architecture has been demonstrated that has potential for reducing manufacturing cost while improving module reliability and recycling for c-Si PV which utilizes an edge-seal. Referred to as Edge Sealed Module (ESM), this architecture eliminates the vacuum lamination process and cross-linked encapsulants on the interior of the module. Functioning prototypes of c-Si have been fabricated for stress testing in collaboration with National Renewable Energy Laboratories (NREL). These modules are being tested and compared to traditionally manufactured modules. Based on preliminary results, this module architecture is a potentially viable solution for improving the manufacturing cost and recyclability of PV modules while enhancing module performance.

costs↗

Development of photovoltaic array and module safety requirements

Safety requirements for photovoltaic module and panel designs and configurations likely to be used in residential, intermediate, and large-scale applications were identified and developed. The National Electrical Code and Building Codes were reviewed with respect to present provisions which may be considered to affect the design of photovoltaic modules. Limited testing, primarily in the roof fire resistance field was conducted. Additional studies and further investigations led to the development of a proposed standard for safety for flat-plate photovoltaic modules and panels. Additional work covered the initial investigation of conceptual approaches and temporary deployment, for concept verification purposes, of a differential dc ground-fault detection circuit suitable as a part of a photovoltaic array safety system.

Source record↗

pvcracks

SAND2024-00922O This software uses electroluminescence images to predict power loss due to cell cracks in photovoltaic modules. The software will incorporate trained variational autoencoder(s) to parameterize cell cracks detected in electroluminescence images of photovoltaic modules and relate cracks to electrical properties; reduced-order models of finite element simulations of electrical behavior of photovoltaic modules under thermomechanical stresses; reduced-order models of stress distributions; inside photovoltaic modules resulting from x-ray topography experiments; and image segmentation and splining methods to analyze x-ray topography measurements of cracked photovoltaic cells. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hartley, James↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours o testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

Photovoltaic (PV) Module Technologies: 2020 Benchmark Costs and Technology Evolution Framework Results

This report benchmarks 2020 PV module minimum sustainable price (MSP) via bottom-up manufacturing cost analysis, for established PV technologies in mass production, including crystalline silicon, cadmium telluride (CdTe), and copper indium gallium (di)selenide. We provide technology roadmaps to additional MSP reductions for these PV technologies. Separately, we consider III-V and perovskite PV technologies which are currently in small-scale or pilot production. Finally, this report uses a technology evolution framework (TEF) to analyze drivers of levelized cost of energy reductions, including installed system cost - which is heavily influenced by module price - as well as service life and annual energy yield.

14 SOLAR ENERGY↗

Solar Photovoltaic (PV) Module Facts and Trends

Unprecedented growth of solar PV has led to growing concerns about PV module toxicity and potential environmental and human health impacts. This factsheet provides objective, science-based data to help address these concerns and empower communities with the resources they need to make solar PV decisions.

14 SOLAR ENERGY↗

Novel Module Architecture for Lower CapEx and Improved Recyclability for c-Si PV Modules

Photovoltaic (PV) energy production is currently increasing at a rate at which recycling is becoming necessary. A novel module architecture has been demonstrated that has potential for high value recycling for c-Si PV. This architecture eliminates the vacuum lamination process and cross-linked en capsulants. Functioning prototypes of c-Si have been fabricated for stress testing in collaboration with NREL. These modules are being tested against traditionally manufactured modules. Based on preliminary results, this module architecture is a potentially viable solution for improving the manufacturing cost and recyclability of PV modules while retaining module performance.

computer architecture↗

Effects of soiling on photovoltaic (PV) modules in the Atacama Desert

Soiling by dry deposition affects the power output of photovoltaic (PV) modules, especially under dry and arid conditions that favor natural atmospheric aerosols (wind-blown dust). In this paper, we report on measurements of the soiling effect on the energy yield of grid-connected crystalline silicon PV modules deployed in five cities across a north-south transect of approximately 1300km in the Atacama Desert ranging from latitude 18°S to latitude 30°S. Energy losses were assessed by comparing side-by-side outputs of four co-planar PV modules. Two of the PV modules of the array were kept clean as a control, while we allowed the other two to naturally accumulate soiling for 12 months (from January 2017 to January 2018). We found that the combination of high deposition rates and infrequent rainfalls led to annual energy losses that peaked at 39% in the northern coastal part of the desert. In contrast, annual energy losses of 3% or less were measured at relatively high-altitude sites and also at locations in the southern part of the desert. For comparison, soiling-induced annual energy losses of about 7% were measured in Santiago, Chile (33°S), a major city with higher rainfall frequency but where urban pollution plays a significant role.

54 ENVIRONMENTAL SCIENCES↗

Evaluation and modeling of the potential effects of a module manufacturing anomaly

Photovoltaic lifetime predictions are in great demand, but are exceedingly difficult to achieve with uncertainties small enough to be useful. During the construction of photovoltaic modules, small unplanned variability in materials or processes can have profound effects on module durability. Thus, continual monitoring of production quality is needed. In the subject production run, module quality, as monitored by damp heat testing, revealed a subset of modules that were prone to higher degradation rates. An assessment of the potential long-term power loss and mitigation strategies was needed. To do this, modules were exposed to variable levels of humidity and temperature with periodic monitoring. The analysis takes into account the kinetics of the degradation and the spatially and temporally varying humidity content within the module during accelerated stress testing. This is an important aspect for extrapolating laboratory results to field exposure because moisture ingress is diffusion limited in most laboratory module tests but not limited in these fielded modules. This analysis predicted that although a solder flux induce degradation mechanism is significant in accelerated stress test, this is probably an artifact of a process with a very large acceleration factor that is not likely to be significant for deployed modules. The degradation mechanism affected a limited area around the tabbing helping to minimize the effect. Furthermore, three years after the system was commissioned, the fielded modules indeed show no significant power loss.

14 SOLAR ENERGY↗

Influence of module requirements on flat plate module design evolution

Photovoltaic module design features and performance characteristics have undergone significant evolutionary changes between pre-1975 First Generation configurations and current Third Generation design technology. A major contributor to this evolution was an iterative process of continuing design guideline and specification development for major module procurements. Module manufacturers have actively responded to these evolving requirements through progressively improving designs. This iterative/feedback process is described. Interim design guidelines and preliminary design options reflecting the LSA 1982 Module Technical Readiness Specification (November 1979) are described with respect to previous design and performance requirements.

Arnett, J. C.↗

Electrical safety requirements: Implications for the module designer

Commercial photovoltaic array installations, which include residential and intermediate applications, are subject to building and electrical codes and to product safety standards. The National Electrical Code (NEC) Article 690, titled Solar Photovoltaic Systems, contains provisions defining acceptable levels of system safety and emphasizes the system design and its installation. The Underwriters Laboratories, Inc. (UL), document titled: Proposed First Edition of the Standard for Flat Plate Photovoltaic Modules and Panels, UL-1703, identifies module and panel construction requirements that ensure product safety. Together these documents describe requirements intended to minimize hazards such as shock and fire. Although initial focus of these requirements is on single crystal silicon modules, they are generic in nature, and are equally applicable to high voltage ( 30 Vdc), multikilowatt, thin film systems. A major safety concern is insulation breakdown within the module or array wiring system, or discontinuities within the electrical conductors. These failures can result in ground faults, in circuit arcs, or exposure to hazardous electrical parts. Safeguards are discussed.

Sugimura, R. S.↗

Knowledge-Based Hazardous Waste Determinations for Solar Photovoltaic (PV) Modules: A Foundational Study

This report explores using "generator knowledge" to determine whether a solar photovoltaic (PV) module must be managed as hazardous waste prior to recycling or landfilling. Generator knowledge is a legal term and existing regulatory pathway for making a hazardous waste determination that has been used by other industries but is a relatively unknown option to the PV industry. In the United States, a hazardous waste determination often acts as a pre-requisite to recycle or landfill a PV module. The results of the hazardous waste determination dictate whether the PV module must be managed as hazardous waste or nonhazardous solid waste. Managing a PV module as hazardous waste requires compliance with stringent U.S. federal and state hazardous waste law. In addition to increased management costs, which can be ten times higher, legal liability for PV modules regulated as hazardous waste is also heightened with both civil and criminal penalties for noncompliance which includes making an inaccurate or faulty hazardous waste determination. The most common reason a PV module would be regulated as hazardous is if it contains a regulated metal in an amount that equals or exceeds the toxicity characteristic limits. To determine whether a PV module exhibits a hazardous characteristic, the regulated person/entity must "apply knowledge...in light of the materials and processes used." In the absence of adequate knowledge to determine whether the PV module is hazardous, it must be tested using Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP) or an equivalent EPA-approved method. Although TCLP is the predominant method used to today to make a hazardous waste determination for PV modules, evidence from this study concludes it is not practical to TCLP test every PV module even in a single utility-scale installation, and a scalable solution is needed. This study finds that knowledge-based hazardous waste determinations may allow a regulated person/entity to make a hazardous waste determination for more than one PV module at one time - making this regulatory pathway a potential scalable solution. Through legal analysis and interviews with 44 experts, the authors explore what it means to make an accurate knowledge-based hazardous determination for PV modules considering sources and forms of information as well as potential limitations. The work aims to provide a foundation for building consensus on whether knowledge-based hazardous determinations are a viable, scalable industry approach for solar.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. This paper presents the description and development status of the PVM thermal control system.

Hacha, Thomas H.↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. The description and development status of the PVM thermal control system is presented.

Hacha, Thomas H.↗