Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Characterizing the Subsurface Using Deformation from Pumping and Surface Loading Tests

Changes in pore pressure or applied load cause deformation that can be used to characterize the subsurface. A series of field tests were conducted by measuring the deformation and pressure response from a variety of stresses at our test site in South Carolina. The site is underlain by saprolite to a depth of 30 m, and the water table in the unconfined aquifer occurs at a depth of 9 m. The types of tests performed included constant-rate pumping tests and surface point loading tests using the weight of a person or vehicle. Vertical displacement of the saprolite in response to these stresses was measured at depths of 3, 6, 9 and 11 meters in both saturated and unsaturated conditions using an extensometer with a resolution of +/- 10 nm. Results from 2.5-hr-long constant-rate pumping tests indicate a repeatable, compressive vertical strain of roughly 0.1 microstrain in the vadose zone and 1-10 microstrain in the saturated zone. Drawdown was 5 m in the pumping well and 0.1 m in a nearby (r = 9m) observation well. Under saturated conditions, the strain rate gradually decreased throughout the test in a pattern that resembles the drawdown curve in the monitoring well. In contrast, the strain in the vadose zone increased quickly early in the test, but the strain rate diminished and was negligible after approximately 30 minutes of pumping. Interestingly, drawdown in the pumping well also increased quickly over 30 minutes and remained roughly constant after that. Additional tests were conducted by applying a load (weight of a person or vehicle) at the ground surface above the extensometer and allowing the signal to stabilize before removing the load. In the vadose zone, the soil compressed rapidly and then stabilized. In the saturated zone, sudden compression was followed by additional compression at a much slower rate. A similar response was observed upon removal of the load. This transient signal in the saturated zone is interpreted to be a poroelastic effect. When a load is applied, the solid skeleton compresses and pressurizes the pore fluid, causing flow. The strain rate is then a function of pressure diffusion. Simulation of the deformation from both pumping and loading tests using an unsaturated, poroelastic finite-element model indicates that strains are sensitive to the Young’s modulus and hydraulic conductivity as functions of saturation.

well tests, strain, surface loading, hydromechanic↗

Cross flow characteristics in a three fuel assemblies

To evaluate the reactor thermal margin of APR+, reactor core flow distribution including both axial and lateral directional hydraulic resistances of fuel assemblies should be known. 3-Ch cross flow test facility has been constructed with three full-size fuel assemblies to investigate the cross flow characteristics. Performance tests have been performed. The axial and lateral directional hydraulic resistances of fuel assemblies have been measured. The test results have been compared to the CFD calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of the Accountability Method as a Means to Classify Radioactive Wastes Processed Using THOR Fluidized Bed Steam Reforming at the Studsvik Processing Facility in Erwin, Tennessee, USA - 13087

Studsviks' Processing Facility Erwin (SPFE) has been treating Low-Level Radioactive Waste using its patented THOR process for over 13 years. Studsvik has been mixing and processing wastes of the same waste classification but different chemical and isotopic characteristics for the full extent of this period as a general matter of operations. Studsvik utilizes the accountability method to track the movement of radionuclides from acceptance of waste, through processing, and finally in the classification of waste for disposal. Recently the NRC has proposed to revise the 1995 Branch Technical Position on Concentration Averaging and Encapsulation (1995 BTP on CA) with additional clarification (draft BTP on CA). The draft BTP on CA has paved the way for large scale blending of higher activity and lower activity waste to produce a single waste for the purpose of classification. With the onset of blending in the waste treatment industry, there is concern from the public and state regulators as to the robustness of the accountability method and the ability of processors to prevent the inclusion of hot spots in waste. To address these concerns and verify the accountability method as applied by the SPFE, as well as the SPFE's ability to control waste package classification, testing of actual waste packages was performed. Testing consisted of a comprehensive dose rate survey of a container of processed waste. Separately, the waste package was modeled chemically and radiologically. Comparing the observed and theoretical data demonstrated that actual dose rates were lower than, but consistent with, modeled dose rates. Moreover, the distribution of radioactivity confirms that the SPFE can produce a radiologically homogeneous waste form. The results of the study demonstrate: 1) the accountability method as applied by the SPFE is valid and produces expected results; 2) the SPFE can produce a radiologically homogeneous waste; and 3) the SPFE can effectively control the waste package classification. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accuracy of automated measurement and verification (M&V) techniques for energy savings in commercial buildings

Trustworthy savings calculations are critical to convincing investors in energy efficiency projects of the benefit and cost-effectiveness of such investments and their ability to replace or defer supply-side capital investments. However, today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of efficiency projects. They also require time-consuming manual data acquisition and often do not deliver results until years after the program period has ended. The rising availability of “smart” meters, combined with new analytical approaches to quantifying savings, has opened the door to conducting M&V more quickly and at lower cost, with comparable or improved accuracy. These meter- and software-based approaches, increasingly referred to as “M&V 2.0”, are the subject of surging industry interest, particularly in the context of utility energy efficiency programs. Program administrators, evaluators, and regulators are asking how M&V 2.0 compares with more traditional methods, how proprietary software can be transparently performance tested, how these techniques can be integrated into the next generation of whole-building focused efficiency programs. This paper expands recent analyses of public-domain whole-building M&V methods, focusing on more novel M&V2.0 modeling approaches that are used in commercial technologies, as well as approaches that are documented in the literature, and/or developed by the academic building research community. We present a testing procedure and metrics to assess the performance of whole-building M&V methods. We then illustrate the test procedure by evaluating the accuracy of ten baseline energy use models, against measured data from a large dataset of 537 buildings. The results of this study show that the already available advanced interval data baseline models hold great promise for scaling the adoption of building measured savings calculations using Advanced Metering Infrastructure (AMI) data. Median coefficient of variation of the root mean squared error (CV(RMSE)) was less than 25% for every model tested when twelve months of training data were used. With even six months of training data, median CV(RMSE) for daily energy total was under 25% for all models tested. Finally, these findings can be used to build confidence in model robustness, and the readiness of these approaches for industry uptake and adoption

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of local hydride re-orientation in high burn-up PWR fuel rods induced by high pressure at high temperatures

Hydride re-orientation in high burn-up PWR fuel rods was induced by high pressure at high temperatures. The high-burnup specimens were sectioned from PWR rods taken from a 15×15 assembly of the H.B. Robinson (HBR) Unit 2 reactor. Out-of cell benchmark tests performed on unirradiated hydrided Zircaloy-4 specimens were conducted to determine the appropriate temperature, pressure, cooling rate, and number of cooling cycles for the reorientation of the irradiated in-cell specimens. The in-cell hydride reorientation tests were performed using high-burnup fuel specimens under a hoop stress ≈145 MPa at 400°C. The specimens were heated to the target temperature of 400°C, held for 3 hours, cooled at 1°C/min to 170°C,and then heated at 1°C/min to the target temperature again for five cycles. Post test metallographic examinations showed that a significant amount of radial hydrides were induced in the HBR fuel rods. The length of radial hydride was up to 60 μm. For unirradiated materials, the ductility of the radial hydride treated specimens is significantly reduced as compared to the as-hydrided specimens having the same hydrogen concentration (≈300 wppm in this work). The mechanical testing on irradiated fueled samples with hydride reorientation experiments have been performed, and will be reported separately in the near future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Secondary Waste Form Screening Test Results—Cast Stone and Alkali Alumino-Silicate Geopolymer

PNNL is conducting screening tests on the candidate waste forms to provide a basis for comparison and to resolve the formulation and data needs identified in the literature review. This report documents the screening test results on the Cast Stone cementitious waste form and the Geopolymer waste form. Test results suggest that both the Cast Stone and Geopolymer appear to be viable waste forms for the solidification of the secondary liquid wastes to be treated in the ETF. The diffusivity for technetium from the Cast Stone monoliths was in the range of 1.2 × 10-11 to 2.3 × 10-13 cm2/s during the 63 days of testing. The diffusivity for technetium from the Geopolymer was in the range of 1.7 × 10-10 to 3.8 × 10-12 cm2/s through the 63 days of the test. These values compare with a target of 1 × 10-9 cm2/s or less. The Geopolymer continues to show some fabrication issues with the diffusivities ranging from 1.7 × 10-10 to 3.8 × 10-12 cm2/s for the better-performing batch to from 1.2 × 10-9 to 1.8 × 10-11 cm2/s for the poorer-performing batch. In the future more comprehensive and longer term performance testing will be conducted, to further evaluate whether or not these waste forms will meet the regulation and performance criteria needed to cost-effectively dispose of secondary wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Test Report: Preliminary Aquifer Test Characterization Results for Well 299-W15-225: Supporting Phase I of the 200-ZP-1 Groundwater Operable Unit Remedial Design

This report examines the hydrologic test results for both local vertical profile characterization and large-scale hydrologic tests associated with a new extraction well (well 299-W15-225) that was constructed during FY2009 for inclusion within the future 200-West Area Groundwater Treatment System that is scheduled to go on-line at the end of FY2011. To facilitate the analysis of the large-scale hydrologic test performed at newly constructed extraction well 299-W15-225 (C7017; also referred to as EW-1 in some planning documents), the existing 200-ZP-1 interim pump-and-treat system was completely shut-down ~1 month before the performance of the large-scale hydrologic test. Specifically, this report 1) applies recently developed methods for removing barometric pressure fluctuations from well water-level measurements to enhance the detection of hydrologic test and pump-and-treat system effects at selected monitor wells, 2) analyzes the barometric-corrected well water-level responses for a preliminary determination of large-scale hydraulic properties, and 3) provides an assessment of the vertical distribution of hydraulic conductivity in the vicinity of newly constructed extraction well 299-W15-225. The hydrologic characterization approach presented in this report is expected to have universal application for meeting the characterization needs at other remedial action sites located within unconfined and confined aquifer systems.

54 ENVIRONMENTAL SCIENCES↗

2020 Hyperion Infrasound Sensor Equilibration Evaluation

Sandia National Laboratories has performed testing on several Hyperion 5313A infrasound sensors in order to determine the length of time it takes for the sensors to thermally equilibrate under a variety of environmental conditions. The motivation for performing these tests is to aid in determining suitable procedures for station operators to follow when installing these sensors. The desired outcome is for the station operators to be able to determine more quickly and reliably whether the sensors are performing correctly at the time of installation.

47 OTHER INSTRUMENTATION↗

Evaluation of antifouling surfaces using a method that employs mussel larvae settlement quantified by machine learning

Antifouling coating development requires extensive performance testing. Coatings that prevent aquatic larval settlement are of interest because many forms of macrofouling begin at the larval stage. However, field testing can be time consuming and poorly controlled. Herein is reported a screening tool, Settlement of Larvae Assay using Mussels (SLAM), for down-selecting materials prior to field testing. The method entails using a dense concentration of mussel larvae that are allowed to settle on submerged test surfaces. Settled larvae are then quantified to provide a measure of antifouling performance. The SLAM test differentiated coatings with only slight differences in formulation. To enable efficient quantification of dense larvae settlement, an automated counting method was developed that combines two analyses: a color thresholding identifies larvae clumps, and a machine learning algorithm identifies non-clumped larvae. Finally, this automated ‘hybrid’ approach rapidly quantifies settled larvae as effectively as manual counting but in a fraction of the time.

Mytilus↗

The Development of a Smart Distribution Grid Testbed for Integrated Information Management Systems

This paper presents a smart distribution grid testbed to test or compare designs of integrated information management systems (I2MSs). An I2MS extracts and synthesizes information from a wide range of data sources to detect abnormal system behaviors, identify possible causes, assess the system status, and provide grid operators with response suggestions. The objective of the testbed is to provide a modeling environment with sufficient data sources for the I2MS design. The testbed includes five information layers and a physical layer; it generates multi-layer chronological data based on actual measurement playbacks or simulated data sets produced by the physical layer. The testbed models random hardware failures, human errors, extreme weather events, and deliberate tampering attempts to allow users to evaluate the performance of different I2MS designs. Initial results of I2MS performance tests showed that the testbed created a close-to-real-world environment that allowed key performance metrics of the I2MS to be evaluated.

99 GENERAL AND MISCELLANEOUS↗

9977 type b packaging internal data collection feasibility testing - magnetic field communications

The objective of this report is to document the findings from proof-of-concept testing performed by the Savannah River National Laboratory (SRNL) R&D Engineering and Visible Assets, Inc. for the DOE Packaging Certification Program (PCP) to determine if RuBee (IEEE 1902.1) tags and readers could be used to provide a communication link from within a drum-style DOE certified Type B radioactive materials packaging. A Model 9977 Type B Packaging was used to test the read/write capability and range performance of a RuBee tag and reader. Testing was performed with the RuBee tags placed in various locations inside the packaging including inside the drum on the outside of the lid of the containment vessel and also inside of the containment vessel. This report documents the test methods and results. A path forward will also be recommended.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Composite Materials and Meta Materials for a New Approach to ITER ICRH Loads

Preliminary laboratory testing of ICRH antennas is a very useful step before their commissioning. Traditionally, pure water, salt water or baking soda water loads are used. These 'water' loads are convenient but strongly limited in terms of performance testing. We have started two feasibility studies for advanced ICRH loads made of ferroelectric ceramics (passive loads) and meta materials (active loads). Preliminary results are very encouraging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The second generation Singapore high resolution proton beam writing facility

A new proton beam focusing facility, designed for proton beam writing (PBW) applications has been tested. PBW allows for proximity free structuring of high aspect ratio, high-density 3D nanostructures. The new facility is designed around OM52 compact quadrupole lenses capable of operating in a variety of high demagnification configurations. Performance tests show that proton beams can be focused down to 19.0 x 29.9 nm{sup 2} and single line scans show a beam width of 12.6 nm. The ultimate goal of sub 10 nm structuring with MeV protons will be discussed.

43 PARTICLE ACCELERATORS↗

Measurement of steel plate perforation tests with digital image correlation.

The results of a series of punch-through tests performed on steel plates are presented. The geometry consisted of circular plates with welded boundary condition penetrated by a conical shaped punch with either a radiused or flat cylindrical end. After initial failure, the conical portion of the punch was driven through the plate to exercise tearing mechanics. Tests were performed quasi-statically with a hydraulic actuator and dynamically using a high-capacity drop table. Deformation and strain were measured with a stereo DIC system. The quasi-static tests utilized a conventional direct-view DIC technique while the dynamic tests required development of an indirect-view technique using a mirror. Experimental details used to conduct the test series will be presented along with test results. Methods of assessing test-to-test repeatability will be discussed. DIC results will also be synchronized and compared with transducer data (displacement and strain).

36 MATERIALS SCIENCE↗

T-1072: Beam test for muon strips

Beam test for muon strips is an experiment to measure the efficiency, time resolution and longitudinal position resolution of scintillator strips for a muon system at future colliders. The muon system at future colliders is envisioned as several layers of position-sensitive detectors embedded in the iron flux-return yoke of the solenoidal magnet. The role of the muon system is primarily the identification of muons and track matching to the central tracker, besides serving as the tail catcher for the hadronic showers that penetrate beyond the hadron calorimetry. Previous tests performed at Fermilab with cosmic muons have shown that scintillators with wavelength-shifting (WLS) fibers and a SiPM readout offer promising performance (NIM A 823, 2016, pp.120-125). The purpose of the present beam tests is to determine the performance parameters with better accuracy. The measurement setup is schematically presented in Fig. 1. The length of the tested strips will vary between 1 m and 2 m. The scintillator strip to be tested will be placed horizontally perpendicular to the beam on a platform in the area behind the beam dump of MT6.2. Two fast scintillators S1 and S2 with vacuum PMT readout will be placed in front and after the tested strip in the beam. The distance between S1 and S2 is 1 m. One fast scintillator strip S3 will be placed in beam immediately in front of the tested strip, perpendicular to the tested strip. A rack with a CAMAC crate and two NIM crates will be used for the data acquisition. The data collection will be performed and monitored from a PC with USB connection to the CAMAC Crate controller.

43 PARTICLE ACCELERATORS↗

An Overview of Facilities and Capabilities to Support the Development of Nuclear Thermal Propulsion

Abstract. The future of American space exploration depends on the ability to rapidly and economically access locations of interest throughout the solar system. There is a large body of work (both in the US and the Former Soviet Union) that show that Nuclear Thermal Propulsion (NTP) is the most technically mature, advanced propulsion system that can enable this rapid and economical access by its ability to provide a step increase above what is a feasible using a traditional chemical rocket system. For an NTP system to be deployed, the earlier measurements and recent predictions of the performance of the fuel and the reactor system need to be confirmed experimentally prior to launch. Major fuel and reactor system issues to be addressed include fuel performance at temperature, hydrogen compatibility, fission product retention, and restart capability. The prime issue to be addressed for reactor system performance testing involves finding an affordable and environmentally acceptable method to test a range of engine sizes using a combination of nuclear and non-nuclear test facilities. This paper provides an assessment of some of the capabilities and facilities that are available or will be needed to develop and test the nuclear fuel, and reactor components. It will also address briefly options to take advantage of the greatly improvement in computation/simulation and materials processing capabilities that would contribute to making the development of an NTP system more affordable. Keywords: Nuclear Thermal Propulsion (NTP), Fuel fabrication, nuclear testing, test facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shear Strength Measurement Benchmarking Tests for K Basin Sludge Simulants

Equipment development and demonstration testing for sludge retrieval is being conducted by the K Basin Sludge Treatment Project (STP) at the MASF (Maintenance and Storage Facility) using sludge simulants. In testing performed at the Pacific Northwest National Laboratory (under contract with the CH2M Hill Plateau Remediation Company), the performance of the Geovane instrument was successfully benchmarked against the M5 Haake rheometer using a series of simulants with shear strengths (τ) ranging from about 700 to 22,000 Pa (shaft corrected). Operating steps for obtaining consistent shear strength measurements with the Geovane instrument during the benchmark testing were refined and documented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A convenient miniature test platform for polyelectrolyte membrane fuel-cell research

We report a simple and convenient small-scale fuel-cell test platform was created from a commercial compression fitting and graphite rod current collectors and used to conduct diagnostic tests on disk-shaped membrane-electrode assemblies (MEAs) fabricated from Nafion membranes and Nafion-impregnated platinum-on-carbon-cloth anodes and cathodes. A key advantage of this test platform is that it requires very little material, perhaps just a few milligrams, to conduct a fuel-cell test on a supported catalyst. Electrochemically-active surface area (ECSA) values for supported platinum on carbon-cloth electrodes were obtained by in-situ (in the fuel cell) and ex-situ (in liquid electrolyte) cyclic voltammetry on similarly-prepared electrodes, and values obtained by these methods were compared with each other to estimate the fraction of platinum catalyst contacted by the Nafion ionomer in the fuel-cell cathode. Polarization curves were acquired under controlled-potential conditions using slow-scan cyclic and sampled-current voltammetry and potential-step amperometry methods with conventional electroanalytical instrumentation. Tests performed using this platform are complementary to rotating disk electrode (RDE) voltammetry tests which also allow for catalyst testing on small amounts of material, albeit in the presence of liquid electrolyte, and are commonly used for initial screening of new fuel-cell catalysts. They are also complementary to conventional fuel-cell testing that is commonly performed on MEAs having active areas more than 100 times larger than that in the present cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗