Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal hydraulic analysis of the AFIP-7 irradiation test in the Advanced test Reactor – Model correlation and performance evaluation

We report as a system level code, RELAP5 is widely used in the nuclear field for the reactor hydraulic analysis. In the component/experimental level, it is frequently employed as well. This paper demonstrates that the RELAP5 flow simulation of the AFIP-7 irradiation experiment which has a complicated 3D geometry/flow path deviates by ~28% from the flow evaluation through a computational fluid dynamics (CFD) simulation, which has been validated against a flow test performed at Oregon State University. Thermal safety compliance analysis of an experiment planned to be irradiated in the Advanced Test Reactor is usually performed using the finite element analysis code, Abaqus. This research reveals the disadvantages of the Abaqus simulation in the flow instability and departure from nucleate boiling evaluations via a conjugate heat transfer analysis of the AFIP-7 irradiation experiment. As a result, a detailed CFD simulation is suggested for irradiation experiments with complicated flow paths, rather than a simplified RELAP5 simulation or hand calculations. The validated simulation approach will be integrated with the Boehmite correlations to investigate the oxide growth prediction on the fuel cladding in Part II of this research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Brookfield Homes Passive House Performance Evaluation

TO4 3.1.3: Brookfield Homes Short-Term Results TO5 3.1.3: Brookfield Passive House Monitoring To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certified model home in Denver, CO to evaluate advanced building technologies and to use as a marketing tool for potential homebuyers. Brookfield used a new architect and a new floor plan as a standard production model and constructed it to the PH standard as an upgrade option. This PH was completely built and certified in August 2013.

Array↗

INITIAL CHARACTERIZATION AND PERFORMANCE EVALUATION OF A ZIRCONIUM-BASED METALLIC WASTE FORM

A metallic waste form or alloy system for immobilization of Zircaloy cladding hulls, Undissolved Solids (UDS), Technicium (Tc) metal and Transition Metal Fission Products (TMFP) waste stream materials from separations processes for commercial spent nuclear fuel has been developed, and initial characterization of the phase assemblage and composition, and corrosion testing under aqueous conditions has been completed for the waste form with various levels of surrogate waste species. The waste stream materials are those from processes being developed as part of the Separations Campaign under the Department of Energy's (DOE's) Global Nuclear Energy Partnership (GNEP) program. The development of waste forms for these materials is under the Waste Form Campaign.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydraulic performance evaluation of rod bundle with a concept spacer grid design

In a pressurized water reactor the spacer grid has a great influence on the thermal-hydraulic and mechanical properties of the fuel assembly. In order to improve the overall performance of the fuel assembly, a new concept spacer grid design names CATF with 'non-bending' guide vane is proposed. The hydraulic performance of the CATF grid design is evaluated by using a commercially computational fluid dynamics (CFD) code, ANSYS CFX12.1, and the evaluation result is compared with ordinary spacer grid including bending guide vane. Three dimensional rod bundles including CATF spacer grid and ordinary spacer grid have been simulated. The analysis results show that local resistance coefficient of CATF spacer grid is smaller than that of ordinary spacer grid by about 29.7% because of the non-bending guide vanes. Furthermore, the cross flow strength between subchannels near the outer strap area, the swirl strength and cross flow strength in subchannels near the outer strap area in 1-10 times hydraulic diameter downstream the spacer grid area of the ordinary grid, are larger than that of CATF spacer grid. The two types of spacer grids appear to have the same mixing characteristics in inner-grid area. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solar energy system performance evaluation. Seasonal report for SEECO Lincoln, Lincoln, Nebraska

The Solar Engineering and Equipment Company (SEECO) Lincoln solar energy system, designed for space heating only, is described and its operational performance for a 12 month period from April 1979 through March 1980 is evaluated. The system met 27 percent of the space heating load; however, system losses into the heated space from the storage bin and ductwork were significant. Reducing these losses would add appreciably to the system's efficiency. Net fossil energy savings were 11.31 million BTUs.

Source record↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

black start↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

A comparative study of two-way and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US: performance evaluation and impacts of chemistry–meteorology feedbacks on air quality

The two-way coupled Weather Research and Forecasting and Community Multiscale Air Quality (WRF-CMAQ) model has been developed to more realistically represent the atmosphere by accounting for complex chemistry–meteorology feedbacks. In this study, we present a comparative analysis of two-way (with consideration of both aerosol direct and indirect effects) and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US. Long-term (5 years from 2008 to 2012) simulations using WRF-CMAQ with both offline and two-way coupling modes are carried out with anthropogenic emissions based on multiple years of the U.S. National Emission Inventory and chemical initial and boundary conditions derived from an advanced Earth system model (i.e., a modified version of the Community Earth System Model/Community Atmospheric Model). The comprehensive model evaluations show that both two-way WRF-CMAQ and WRF-only simulations perform well for major meteorological variables such as temperature at 2 m, relative humidity at 2 m, wind speed at 10 m, precipitation (except for against the National Climatic Data Center data), and shortwave and longwave radiation. Both two-way and offline CMAQ also show good performance for ozone (O3) and fine particulate matter (PM 2.5 ). Due to the consideration of aerosol direct and indirect effects, two-way WRF-CMAQ shows improved performance over offline coupled WRF and CMAQ in terms of spatiotemporal distributions and statistics, especially for radiation, cloud forcing, O 3 , sulfate, nitrate, ammonium, elemental carbon, tropospheric O 3 residual, and column nitrogen dioxide (NO 2 ). For example, the mean biases have been reduced by more than 10 W m –2 for shortwave radiation and cloud radiative forcing and by more than 2 ppb for max 8 h O 3 . However, relatively large biases still exist for cloud predictions, some PM 2.5 species, and PM 10 that warrant follow-up studies to better understand those issues. The impacts of chemistry–meteorological feedbacks are found to play important roles in affecting regional air quality in the US by reducing domain-average concentrations of carbon monoxide (CO), O 3 , nitrogen oxide (NO x ), volatile organic compounds (VOCs), and PM 2.5 by 3.1 % (up to 27.8 %), 4.2 % (up to 16.2 %), 6.6 % (up to 50.9 %), 5.8 % (up to 46.6 %), and 8.6 % (up to 49.1 %), respectively, mainly due to reduced radiation, temperature, and wind speed. The overall performance of the two-way coupled WRF-CMAQ model achieved in this work is generally good or satisfactory and the improved performance for two-way coupled WRF-CMAQ should be considered along with other factors in developing future model applications to inform policy making.

58 GEOSCIENCES↗

Performance Evaluation of the SPT-140

As part of an on-going cooperative program with industry, an engineering model SPT-140 Hall thruster, which may be suitable for orbit insertion and station-keeping of geosynchronous communication satellites, was evaluated with respect to thrust and radiated electromagnetic interference at the NASA Lewis Research Center. Performance measurements were made using a laboratory model propellant feed system and commercial power supplies. The engine was operated in a space simulation chamber capable of providing background pressures of 4 x 10(exp -6) Torr or less during thruster operation. Thrust was measured at input powers ranging from 1.5 to 5 kilowatts with two different output filter configurations. The broadband electromagnetic emission spectra generated by the engine was also measured for a range of frequencies from 0.01 to 18,000 Mhz. These results are compared to the noise threshold of the measurement system and MIL-STD-461C where appropriate.

Manzella, David↗

Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries

The performance of a next-generation optical computed tomography scanner (OCTOPUS-5X) is characterized in the context of three-dimensional gel dosimetry. Large-volume (2.2 L), muscle-equivalent, radiation-sensitive polymer gel dosimeters (BANG-3) were used. Improvements in scanner design leading to shorter acquisition times are discussed. The spatial resolution, detectable absorbance range, and reproducibility are assessed. An efficient method for calibrating gel dosimeters using the depth-dose relationship is applied, with photon- and electron-based deliveries yielding equivalent results. A procedure involving a preirradiation scan was used to reduce the edge artifacts in reconstructed images, thereby increasing the useful cross-sectional area of the dosimeter by nearly a factor of 2. Dose distributions derived from optical density measurements using the calibration coefficient show good agreement with the treatment planning system simulations and radiographic film measurements. The feasibility of use for motion (four-dimensional) dosimetry is demonstrated on an example comparing dose distributions from static and dynamic delivery of a single-field photon plan. The capability to visualize three-dimensional dose distributions is also illustrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure analysis and performance evaluation of NASA inertial reference unit (DRIRU 2) after 50 months of orbital operation

The first production DRIRU 2 (NASA standard high performance inertial reference unit) system was launched as a subsystem of the Modular Attitude Control System for the Solar Maximum Mission (SMM) spacecraft in February 1980. This hardware was retrieved during the repair of the SMM during Shuttle Flight 41-C in April 1984 and returned to Teledyne Systems Company (manufacturer) for investigation and performance measurements as directed by Goddard Space Flight Center. A failure of one of the three gyro channels occurred approximately 6.5 months after launch. The built in redundancy functioned properly, the DRIRU 2 continued to provide the required attitude control function without performance degradation. Subsequent failure of other attitude control subsystems made the SMM a candidate for the first demonstration of the shuttle in-orbit repair capabilty. The in-orbit DRIRU 2 II failure scenario and the results of the analyses/tests conducted after retrieval are discussed. Comparison of this data with similar data prior to launch demonstates the excellent stability of performance parameters achieveable with DRIRU 2.

Green, K. N.↗