Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRINTED CIRCUIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512

Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named “MagicPlate-512” (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on ap-type substrate. An array contains of 512 pixels with size 0.5 × 0.5 mm{sup 2} and pitch 2 mm with an overall dimension of 52 × 52 mm{sup 2}. The MP512 monolithic detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of raisin to preserve the silicon detector from moisture and chemical contamination and to protect the bonding wires. Characterization of the silicon monolithic diode array response was performed, and included pixels response uniformity, dose linearity, percent depth dose, output factor, and beam profiling for beam sizes relevant to SBRT and SRS and depth dose response in comparison with ionization chamber. Results: MP512 shows a good dose linearity (R{sup 2} = 0.998) and repeatability within 0.2%. The measured depth dose response for field size of 10 × 10 cm{sup 2} agreed to within 1.3%, when compared to a CC13 ionization chamber for depths in PMMA up to 30 cm. The output factor of a 6 MV Varian 2100EX medical linac beam measured by MP512 at the isocenter agrees to within 2% when compared to PTW diamond, Scanditronix point EDD-2 diode and MOSkin detectors for field sizes down to 1 × 1 cm{sup 2}. An over response of 4% was observed for square beam size smaller than 1 cm when compared to EBT3 films, while the beam profiles (FWHM) of MP512 match to within 2% the data measured by radiochromic film. Conclusions: The response of the 2D detector array, MP512, has been evaluated. The properties of the array demonstrated suitability for use as in phantom dosimeter for QA in SRS and SBRT. Although MP512 matches film measurements down to 1 × 1 cm{sup 2} well, it showed a discrepancy of 4% in the determination of output factors of beams smaller than 0.5 × 0.5 cm{sup 2} due to the field perturbation generated by the large amount of silicon surrounding the central diode. MP512 is highly capable of measuring beam size (FWHM) and has a discrepancy of less than 1.3% when compared to EBT3 film. A reduction in the detector pitch to less than 2 mm would improve the penumbra reconstruction accuracy at the cost readout electronics complexity.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗

RF mixing modules for superconducting qubit room temperature control systems v1.0

We have developed a series of compact RF mixing boards by integrating I/Q quadrature mixing, IF(intermediate frequency)/LO(local oscillator)/RF power level adjustments, and DC (direct current) bias fine tuning on a 40 mm × 80 mm 4-layer PCB (printed circuit board) board with EMI (electromagnetic interference) shielding.

Huang, Gang↗

TTW (Transition to Wire Device) [SWR-25-02]

The Transition to Wire (TTW) hardware project is a method for connecting solar research samples with fragile interconnects to robust, weatherproof and consistent commercial connectors. The Transition to Wire device is a printed circuit board designed to facilitate the transition from tab ribbon or other unsecured electrical contacts on research samples to either wires or a connector. The four pin connector provides a kelvin (4 wire) connection at the solder pad where the sample connects.

McDanold, Byron↗

Simultaneous Strain and Temperature Sensing using a Microstrip Patch Antenna

In this paper, we present simultaneous strain and temperature sensing using a single microstrip patch antenna fabricated on commercial printed circuit board (PCB). Temperature and strain are extracted from the resonant frequencies of the patch antenna as these frequencies are dependent on the dielectric constant of the PCB and the patch dimensions, which are subject to change with applied strain and temperature variations. The principle of operation of the patch antenna is first discussed, followed by the design and fabrication of the instrumented test specimen. Finally, thermal and mechanical tests were conducted to validate the strain and temperature sensing performance of the antenna sensor

TCHAFA, FRANCK MBANYA↗

RELAP5-3D Modeling of Heat Transfer Components (Intermediate Heat Exchanger and Helical-Coil Steam Generator) for NGNP Application

The Next Generation Nuclear Plant project is aimed at the research and development of a helium-cooled high-temperature gas reactor that could generate both electricity and process heat for the production of hydrogen. The heat from the high-temperature primary loop must be transferred via an intermediate heat exchanger to a secondary loop. Using RELAP5-3D, a model was developed for two of the heat exchanger options a printed-circuit heat exchanger and a helical-coil steam generator. The RELAP5-3D models were used to simulate an exponential decrease in pressure over a 20 second period. The results of this loss of coolant analysis indicate that heat is initially transferred from the primary loop to the secondary loop, but after the decrease in pressure in the primary loop the heat is transferred from the secondary loop to the primary loop. A high-temperature gas reactor model should be developed and connected to the heat transfer component to simulate other transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

Supercritical CO 2 recompression Brayton cycle: completed assembly description

Through multi-year funding from DOE-NE, Sandia National Labs supercritical carbon dioxide (SCO 2 ) closed Brayton cycle (CBC) research and development team have recently overseen the completion of the SCO 2 CBC recompression test assembly (TA), and delivery from the development contractor’s facility to Sandia, Albuquerque. The primary components of the completed TA include two turbo alternator-compressors and associated motor/controllers, three printed circuit heat exchangers, and six shell-and-tube heaters and associated controllers. Principal supporting components include a cooling tower, electricity-dissipating load bank, and leakage flow management equipment. With this milestone completed, significant increase in CBC R&D is anticipated with the objective of advancing the technology readiness level of components seen by industry as immature. This report presents detailed descriptions of all components and operating software necessary to operate the recompression CBC.

Pasch, James Jay↗

Summary of HQ01e magnetic measurements

The magnetic measurements of HQ01e, a 1 m long LHC Accelerator Research Program (LARP) high-gradient quadrupole model, were performed at 4.4 K and above 40 K at the magnet test facility of LBNL in July 2011. The 120 mm aperture cos2 θ Nb 3 Sn magnet was designed with accelerator magnet features including alignment and field quality. Conductor-limited gradient was 195 T/m at 4.4 K. During the measurement, a ramp rate of 10 A/s was used and measurements at the nominal current of 14.2 kA (82% of short-sample limit with a gradient of 160 T/m) were performed using the 250 mm long printed-circuit board rotating probe developed by FNAL. At 14.2 kA, 2.7 units of b 6 and 0.7 units of b 10 were measured. Large persistent current contribution and strong dynamic effects were observed.

43 PARTICLE ACCELERATORS↗

Validation and Verification of the Correct Operation of the Savannah River National Laboratories, Model SRNL-Rev. 2, Serial # SRNL-003 Coulometer.

In August of 2011, C-AAC successfully installed a new coulometer. This system was only the third ever built of a newly redesigned system that SRNL had completed. The other two new systems reside at the IAEA in Vienna and at SRNL in South Carolina. The new system will replace an old PAR173 system that had been the workhorse of the Plutonium Assay team since the early 1970s. This 40+ year old system was not computer compatible and no longer had available spare parts. Upon the request of the IAEA and C-AAC personnel, the SRNL team undertook a project to modernize their systems and completely revamped the electronics and data acquisition system of their coulometry models (designed and built in the early 1990’s) by combining all electronics on a single, multilayer printed circuit board with individual isolated ground and power planes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a Test Facility to Investigate Fundamental Na-CO 2 Interactions in Compact Heat Exchangers

One of the key objectives of the SFR R&D program is to develop and demonstrate innovative cost reduction and performance enhancing technologies for SFRs. The supercritical carbon dioxide (S-CO 2 ) Brayton cycle power converter system has been identified as one such innovation that could contribute to meeting this objective. One appealing feature of this system is the small footprint that the hardware requires, which is in part due to the use of Printed Circuit Heat Exchangers (PCHEs) as the secondary (Na-to-CO 2 ) heat exchanger as well as the recuperator and cooler modules. Although PCHEs have a high degree of structural integrity, the potential for leak(s) to develop between the sodium and CO2 coolant channels in the secondary heat exchanger cannot be ruled out, leading to discharge of high pressure CO 2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to gas jet blowdown into the secondary sodium loop is not deemed to be a likely scenario. Rather, small crack(s) (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The primary focus of the current work is to develop an experiment capability to investigate reaction characteristics under micro-leak conditions. This report summarizes the progress that was made towards meeting this objective this fiscal year. In particular, the facility scaling rationale was developed, and on that basis, the detailed facility design and operating procedures were completed. Based on the design work, fabrication drawings for the three primary system components (i.e., test vessel, dump tank, and separator/vapor trap) were generated and submitted to an outside vendor (i.e., Ability Engineering Technology in South Holland, IL) for fabrication. Fabrication of these components was also completed this year. Plans are to have the facility assembled by the midpoint of FY11 and to begin shakedown testing at that time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scaling considerations for a multi-megawatt class supercritical CO2 brayton cycle and commercialization.

Small-scale supercritical CO2 demonstration loops are successful at identifying the important technical issues that one must face in order to scale up to larger power levels. The Sandia National Laboratories supercritical CO2 Brayton cycle test loops are identifying technical needs to scale the technology to commercial power levels such as 10 MWe. The small size of the Sandia 1 MWth loop has demonstration of the split flow loop efficiency and effectiveness of the Printed Circuit Heat Exchangers (PCHXs) leading to the design of a fully recuperated, split flow, supercritical CO2 Brayton cycle demonstration system. However, there were many problems that were encountered, such as high rotational speeds in the units. Additionally, the turbomachinery in the test loops need to identify issues concerning the bearings, seals, thermal boundaries, and motor controller problems in order to be proved a reliable power source in the 300 kWe range. Although these issues were anticipated in smaller demonstration units, commercially scaled hardware would eliminate these problems caused by high rotational speeds at small scale. The economic viability and development of the future scalable 10 MWe solely depends on the interest of DOE and private industry. The Intellectual Property collected by Sandia proves that the ~10 MWe supercritical CO2 power conversion loop to be very beneficial when coupled to a 20 MWth heat source (either solar, geothermal, fossil, or nuclear). This paper will identify a commercialization plan, as well as, a roadmap from the simple 1 MWth supercritical CO2 development loop to a power producing 10 MWe supercritical CO2 Brayton loop.

Fleming, Darryn D.↗

Multipole approximation of special nonlinear magnets for the IOTA ring

All existing focusing optics for accelerators are built to be "linear", i.e. the transverse focusing force is proportional to the particle displacement from the closed orbit. Such approach is used in order to make trajectories stable in the entire area of phase space, because the potential describing linear focusing is integrable and does not produce chaotic motion. Technically, the needed field is achieved with the help of dipole and quadrupole magnets. But the linear motion is unstable to perturbations in the focusing fields and excludes any betatron tune spread over particle's energy, which is beneficial for the beam stability. Moreover, the focusing strength depends on the particle's energy deviation from the designed one. These undesired effects are usually suppressed by the addition of non- linear elements, such as sextupoles and octupoles. Unfortunately, these additions make focusing potential nonintegrabe, leading to the limitation of stable phase space area. Recent research showed, that there exist non-linear potentials that, nevertheless, are fully integrable [1, 2]. Thus, there is an opportunity to create stable non-linear focusing optics that provides high betatron tune spread and mitigate magnetic field errors. This approach is to be implemented in electron storage ring called Integrable Optics Test Accelerator (IOTA) at Fermilab [3]. The main goal is to show the possibility to implement the nonlinear integrable system in a realistic accelerator design. Development of a magnet, which creates exact non-linear potential, is a technically complicated task, that takes much time and efforts. However, it is possible to expand the non- linear potential into superposition of multipoles of even orders (i.e quadrupole, octupole, etc.). Though this series is not convergent in the entire space, a few low order terms can be used to model the true potential in some limited area. In turn, each of the multipole potentials can be generated by speci ed electrical current in PCB coiled on the surface of storage ring's vacuum tube. Such approach is much cheaper than the creation of a magnet of solid iron with high current coil and faster than the development of \exact" non-linear magnet, but it can help identify some features of non-linear integrable optics application. The goal of this research work is to find analytically the angular distribution of electrical current on the surface of the vacuum tube, which creates inside it multipole potential with given parameters. Hereafter, there is the task to develop a model of flexible printed circuit board (PCB), which could be coiled around the vacuum tube in order to provide the desired current distribution.

Vorobev, Viktor↗

Design guidelines for SAR digital receiver/exciter boards.

High resolution radar systems generally require combining fast analog to digital converters and digital to analog converters with very high performance digital signal processing logic. These mixed analog and digital printed circuit boards present special challenges with respect to electromagnetic interference. This document first describes the mechanisms of interference on such boards then follows up with a discussion of prevention techniques and finally provides a checklist for designers to help avoid common mistakes.

Dudley, Peter A.↗

Strategic need for a multi-purpose thermal hydraulic loop for support of advanced reactor technologies

This report presents a conceptual design for a new high-temperature multi fluid, multi loop test facility for the INL to support thermal hydraulic, materials, and thermal energy storage research for nuclear and nuclear-hybrid applications. In its initial configuration, the facility will include a high-temperature helium loop, a liquid salt loop, and a hot water/steam loop. The three loops will be thermally coupled through an intermediate heat exchanger (IHX) and a secondary heat exchanger (SHX). Research topics to be addressed with this facility include the characterization and performance evaluation of candidate compact heat exchangers such as printed circuit heat exchangers (PCHEs) at prototypical operating conditions, flow and heat transfer issues related to core thermal hydraulics in advanced helium-cooled and salt-cooled reactors, and evaluation of corrosion behavior of new cladding materials and accident-tolerant fuels for LWRs at prototypical conditions. Based on its relevance to advanced reactor systems, the new facility has been named the Advanced Reactor Technology Integral System Test (ARTIST) facility. Research performed in this facility will advance the state of the art and technology readiness level of high temperature intermediate heat exchangers (IHXs) for nuclear applications while establishing the INL as a center of excellence for the development and certification of this technology. The thermal energy storage capability will support research and demonstration activities related to process heat delivery for a variety of hybrid energy systems and grid stabilization strategies. Experimental results obtained from this research will assist in development of reliable predictive models for thermal hydraulic design and safety codes over the range of expected advanced reactor operating conditions. Proposed/existing IHX heat transfer and friction correlations and criteria will be assessed with information on materials compatibility and instrumentation needs. The experimental database will guide development of appropriate predictive methods and be available for code verification and validation (V&V) related to these systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY 2014 Sodium-Supercritical CO 2 Interactions in the SNAKE Experiment Facility

One appealing feature of the supercritical carbon dioxide Brayton cycle energy conversion system is the small footprint that the hardware requires, which is in part due to the use of compact diffusion-bonded heat exchangers such as Printed Circuit Heat Exchanger (PCHEs) or Hybrid Heat Exchangers (H 2 X) as the heat source heat exchanger (sodium-to-CO 2 ) as well as the recuperator and cooler modules. Although PCHEs and H 2 Xs have a high degree of structural integrity, the potential for leaks to develop between the sodium and CO 2 coolant channels in the heat exchanger cannot be ruled out, and this would lead to discharge of high pressure CO 2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to CO 2 jet blowdown into the secondary sodium loop is not deemed likely. Rather, small cracks (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The goal of the sodium-CO 2 interaction tests is to gain a fundamental understanding of sodium-CO 2 interactions under prototypical conditions of compact diffusion-bonded heat exchanger failure, a fundamental understanding of self-plugging if it occurs, and the development of one-dimensional phenomenological models for the interactions between high-pressure CO 2 issuing into liquid sodium from a micro-leak across a stainless steel pressure boundary. These models will be validated using experiment data. Therefore, an experiment program at Argonne was initiated in Fiscal Year 2010 to investigate the reaction behavior between sodium and CO 2 under micro-leak conditions. Several reports have described the facility scaling rationale and design. Assembly of the SNAKE (S-CO 2 , Na Kinetics Experiment) began in Fiscal Year 2011 and was completed in July 2012. The sodium inventory in this facility consists of approximately 44 lbs (20 kg; ~21 L/5.5 gal).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗