Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PNEUMATICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Resonance Control System for the PIP-II IT HWR Cryomodule

The HWR (half-wave-resonator) cryomodule is the first one in the superconducting section of the PIP-II LINAC project at Fermilab. PIP-II IT is a test facility for the project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The HWR cryomodule comprises 8 cavities operating at a frequency of 162.5 MHz and accelerating beam up to 10 MeV. Resonance control of the cavities is performed with a pneumatically operated slow tuner which compresses the cavity at the beam ports. Helium gas pressure in a bellows mounted to an end wall of the cavity is controlled by two solenoid valves, one on the pressure side and one on the vacuum side. The resonant frequency of the cavity can be controlled in one of two modes. A pressure feedback control loop can hold the cavity tuner pressure at a fixed value for the desired resonant frequency. Alternately, the feedback loop can regulate the cavity tuner pressure to bring the RF detuning error to zero. The resonance controller is integrated into the LLRF control system for the cryomodule. The control system design and performance of the resonance control system are described in this paper.

43 PARTICLE ACCELERATORS↗

Performance of the LLRF System for the Fermilab PIP-II Injector Test

PIP-II IT is a test facility for the PIP-II project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The 8-cavity half-wave-resonator (HWR) cryomodule operating at 162.5 MHz is followed by the 8-cavity single-spoke resonator(SSR1) cryomodule operating at 325 MHz. The LLRF systems for both cryomodules are based on a common SOC FPGA-based hardware platform. The resonance control systems for the two cryomodules are quite different, the first being a pneumatic system based on helium pressure and the latter a piezo/stepper motor type control. The data acquisition and control system can support both CW and Pulsed mode operations. Beam loading compensation is available which can be used for both manual/automatic control in the LLRF system. The user interfaces include EPICS, Labview, and ACNET. Testing of the RF system has progressed to the point of being ready for a 2 mA beam to be accelerated to 25 MeV. The design and performance of the field control and resonance control system operation with beam are presented in this paper.

43 PARTICLE ACCELERATORS↗

Advanced Methods for Modeling Water-Levels and Estimating Drawdowns with SeriesSEE, an Excel Add-In

Water-level modeling is used for multiple-well aquifer tests to reliably differentiate pumping responses from natural water-level changes in wells, or environmental fluctuations. Synthetic water levels are created during water-level modeling and represent the summation of multiple component fluctuations, including those caused by environmental forcing and pumping. Pumping signals are modeled by transforming step-wise pumping records into water-level changes by using superimposed Theis functions. Water-levels can be modeled robustly with this Theis-transform approach because environmental fluctuations and pumping signals are simulated simultaneously. Water-level modeling with Theis transforms has been implemented in the program SeriesSEE, which is a Microsoft® Excel add-in. Moving average, Theis, pneumatic-lag, and gamma functions transform time series of measured values into water-level model components in SeriesSEE. Earth tides and step transforms are additional computed water-level model components. Water-level models are calibrated by minimizing a sum-of-squares objective function where singular value decomposition and Tikhonov regularization stabilize results. Drawdown estimates from a water-level model are the summation of all Theis transforms minus residual differences between synthetic and measured water levels. The accuracy of drawdown estimates is limited primarily by noise in the data sets, not the Theis-transform approach. Drawdowns much smaller than environmental fluctuations have been detected across major fault structures, at distances of more than 1 mile from the pumping well, and with limited pre-pumping and recovery data at sites across the United States. In addition to water-level modeling, utilities exist in SeriesSEE for viewing, cleaning, manipulating, and analyzing time-series data.

58 GEOSCIENCES↗

Estimating the Impact (Energy, Emissions and Economics) of the U.S. Fluid Power Industry

The objective of this report is to estimate the impact (energy, emissions and economics) of United Fluid power (hydraulic and pneumatic actuation) is the generation, control, and application of pumped or compressed fluids when this power is used to provide force and motion to mechanisms. This form of mechanical power is an integral part of United States (U.S.) manufacturing and transportation. In 2008, according to the U.S. Census Bureau, sales of fluid power components exceeded $\$$17.7B, sales of systems using fluid power exceeded $\$$226B. As large as the industry is, it has had little fundamental research that could lead to improved efficiency since the late 1960s (prior to the 1970 energy crisis). While there have been some attempts to replace fluid powered components with electric systems, its performance and rugged operating condition limit the impact of simple part replacement. Oak Ridge National Laboratory and the National Fluid Power Association (NFPA) collaborated with 31 industrial partners to collect and consolidate energy specific measurements (consumption, emissions, efficiency) of deployed fluid power systems. The objective of this study was to establish a rudimentary order of magnitude estimate of the energy consumed by fluid powered systems. The analysis conducted in this study shows that fluid powered systems consumed between 2.0 and 2.9 Quadrillion (1015) Btus (Quads) of energy per year; producing between 310 and 380 million metric tons (MMT) of Carbon Dioxide (CO 2 ). In terms of efficiency, the study indicates that, across all industries, fluid power system efficiencies range from less than 9% to as high as 60% (depending upon the application), with an average efficiency of 22%. A review of case studies shows that there are many opportunities to impact energy savings in both the manufacturing and transportation sectors by the development and deployment of energy efficient fluid power components and systems.

energy efficiency↗

Report on Project performance under the CRADA No PNNL/254, PLA 1, between BATTELLE as operator of Pacific Northwest National Laboratory under its U.S. Department of Energy Contract No. DE-AC05-76RL0 1830 and Isonics Corporation, Chairman and CEO: Christopher M. Toffales

Unattended decontamination of bio agents in enclosed environments. The goal of the project is the development of unattended method for environmentally safe, highly effective volumetric decontamination that kills on a contact multiple bio-agents including airborne and surface-adsorbed pathogens of different nature in enclosed environments with complex geometry like various buildings and transportation units as aircraft and ships The method employs two elements, proprietary Vortical Aerosol Generator (VAG) and Electrochemically Activated Solutions (EAS). The prototype of the method was developed under CRADA No PNNL/254, and was shown highly effective for irreversible decontamination of vegetative microbial cells, spores and viruses in a test chamber of ~100 ft 3 and in a room of ~3000 ft 3 . The electrochemical activation technology is based on the production of meta-stable (activated) solutions with anomalous physicochemical and catalytic reactivity for their further use in various technological processes in place of traditionally applied aggressive chemicals. Usual source for electrochemical activation processes is sodium chloride aqueous solution with the concentration of 1.0 g/L. EAS bactericidal effectiveness was previously demonstrated for different applications however, in all previous applications EAS was only used as a liquid agent. Present Method suggests an application of EAS as micro-aerosol (particle size in the range of 0.5-10 mµ), which behaves like a gas and eventually fills entire enclosed environment including hardly, not otherwise accessible sites. The term micro-aerosol of EAS (MAEAS) herein refers to an air-suspended EAS having micro-particle droplets of characteristic cross section and/or size comprising electrochemically-active agents with sufficiently large surface areas whereby the probability of a contact with bio agents in a process area is extremely high. EAS is produced with a commercially available STEL device (FEM-3 flow electrochemical module element; US Pat 5,635,040). Pneumatic Vortical Aerosol Generator (VAG) produces MAEAS. VAG is an original high output atomizer allowing for the production of the aerosol particles with the size in the range of 0.5 to 12 µm at the rate from 5 to 300 ml/min correspondingly, allowing a control of a required particle size. MAEAS has significant advantages over EAS, allowing for simultaneous decontamination of airborne and surface-adsorbed bio agents with minimal volume of atomized EAS and with essentially no waste. Experimental data indicate that MAEAS has very low corrosiveness, possess no negative effect to sensitive equipment and does not destroy the surface of different tested materials. Limited toxicity tests were conducted with mice directly exposed to EAS aerosol; no acute and short-term toxicity was identified.

bioagents↗

Glass Frit Clumping and Dusting

DWPF mixes a slurry of glass frit (Frit 418) and dilute (1.5 wt%) formic acid solution with high level waste in the Slurry Mix Evaporator (SME). There would be advantages to introducing the frit in a non-slurry form to minimize water addition to the SME, however, adding completely dry frit has the potential to generate dust which could clog filters or condensers. Prior testing with another type of frit, Frit 320, and using a minimal amount of water reduced dust generation, however, the formation of hard clumps was observed. To examine options and behavior, a TTQAP [McCabe and Stone, 2013] was written to initiate tests that would address these concerns. Tests were conducted with four types of glass frit; Frit 320, DWPF Frit 418, Bekeson Frit 418 and Multi-Aspirator Frit 418. The last two frits are chemically identical to DWPF Frit 418 but smaller particles were removed by the respective vendors. Test results on Frit Clumping and Dusting are provided in this report. This report addresses the following seven questions. Short answers are provided below with more detailed answers to follow. 1. Will the addition of a small amount of water, 1.5 wt%, to dry DWPF Frit 418 greatly reduce the dust generation during handling at DWPF? a. Yes, a small scale test showed that adding a little water to the frit greatly reduced dust generation during handling. 2. Will the addition of small amounts of water to the frit cause clumping that will impair frit handling at DWPF? a. No, not with Frit 418. Although clumps were observed to form when 1.5 wt% water was mixed with DWPF Frit 418, then compressed and air-dried overnight, the clumps were easily crushed and did not form the hardened material noted when Frit 320 was tested. 3. What is the measured size distribution of dust generated when dry frit is handled? (This affects the feasibility and choice of processing equipment for removing the dust generating fraction of the frit before it is added to the SME.) a. The size distribution for the dust removed from fresh DWPF Frit 418 while it was being shaken in a small scale LabRAM test was measured. The median size on a volume basis was 7.6 μm and 90% of the frit particles were between 1.6 and 28 μm. The mass of dust collected using this test protocol was much less than 1% of the original frit. 4. Can the dust be removed in a small number of processing steps and without the larger frit particles continuing to spall additional dust sized particles? a. Test results using a LabRAM were inconclusive. The LaRAM performs less efficient particle size separation than the equipment used by Bekeson and Multi-Aspirator. 5. What particle size of frit is expected to create a dust problem? a. The original criterion for creating a dusting problem was those particle sizes that were readily suspended when being shaken. For that criterion calculations and Microtrac size analyses indicated that particles smaller than 37 μm are likely dust generators. Subsequently a more sophisticated criterion for dust problem was considered, particle sizes that would become suspended in the air flow patterns inside the SME and possibly plug the condenser. That size may be larger than 37 μm but has not yet been determined. 6. If particles smaller than 37 μm are removed will bulk dust generation be eliminated? a. Video-taped tests were performed using three gallons each of three types of frit 418, DWPF frit, Bekeson frit and Multi-Aspirator frit. Frit was poured through air from a height of approximately eight feet into a container half filled with water. Pouring Bekeson frit or Multi-Aspirator frit generated markedly less visible dust, but there was still a significant amount, which still has the potential of causing a dust problem. 7. Can completely dry frit be poured into the SME without having dust plug the condenser at the top of the vessel? a. Because of the complexity of air currents inside the SME and the difficulty of defensible size scaling a more prototypical test will be required to answer this question. We recommend construction of a full scale mockup of the top half of the SME with a shallow basin of water at the bottom and a simulated condenser at the top. It could be made from simple materials such as PVC pipe, cardboard and clear plastic and tested with dry frit. Depending on results, this may need to be coupled with the proposed pneumatic transfer system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization and Annual Average Power Predictions of a Backward Bent Duct Buoy Oscillating Water Column Device Using the Wells Turbine.

This Technical Report presents work completed by The Applied Research Laboratory at The Pennsylvania State University, in conjunction with Sandia National Labs, on the optimization of the power conversion chain (PCC) design to maximize the Average Annual Electric Power (AAEP) output of an Oscillating Water Column (OWC) device. The design consists of two independent stages. First, the design of a floating OWC, a Backward Bent Duct Buoy (BBDB), and second the design of the PCC. The pneumatic power output of the BBDB in random waves is optimized through the use of a hydrodynamically coupled, linear, frequency-domain, performance model that links the oscillating structure to internal air-pressure fluctuations. The PCC optimization is centered on the selection and sizing of a Wells Turbine and electric power generation equipment. The optimization of the PCC involves the following variables: the type of Wells Turbine (fixed or variable pitched, with and without guide vanes), the radius of the turbine, the optimal vent pressure, the sizing of the power electronics, and number of turbines. Also included in this Technical Report are further details on how rotor thrust and torque are estimated, along with further details on the type of variable frequency drive selected.

13 HYDRO ENERGY↗

AeroValve Experimental Test Data Final Report

This report documents the collection of experimental test data and presents performance characteristics for the AeroValve brand prototype pneumatic bidirectional solenoid valves tested at the Oak Ridge National Laboratory (ORNL) in July/August 2014 as part of a validation of AeroValve energy efficiency claims. The test stand and control programs were provided by AeroValve. All raw data and processing are included in the report attachments.

42 ENGINEERING↗

Ozone Monitor (OZONE) Instrument Handbook

The primary measurement output from the Thermo Scientific Ozone Analyzer is the concentration of the analyte (O3) reported at 1-s resolution in units of ppbv in ambient air. Note that because of internal pneumatic switching limitations the instrument only makes an independent measurement every 4 seconds. Thus, the same concentration number is repeated roughly 4 times at the uniform, monotonic 1-s time base used in the AOS systems. Accompanying instrument outputs include sample temperatures, flows, chamber pressure, lamp intensities and a multiplicity of housekeeping information. There is also a field for operator comments made at any time while data is being collected.

47 OTHER INSTRUMENTATION↗

Passive Leak Detection Using Commercial Hydrogen Colorimetric Indicator

Element One, Inc. (www.elem.com), a small business with in Boulder, CO, has been developing hydrogen detection technology based upon a highly selective colorimetric indicator. In its native state, the indicator pigment is a pale gray color, but becomes black upon exposure to hydrogen. The colorimetric change can be readily observed by the naked eye without the need for supplemental electronics or other hardware. Recently, the colorimetric indicator was integrated into a pliable, self-adhesive tape that can readily wrap around pneumatic fittings to serve as a hydrogen leak detector. A prototype version of the Element One indicator tape was tested within an NREL hydrogen system and successfully identified the unexpected presence of a small leak; a summary document for this case study is presented in Appendix 1. The tape was subsequently configured into 10-foot rolls as a product prototype that has just recently been commercialized and marketed under the tradename DetecTape(R). Figure 1 shows the commercial version of DetecTape along with an indicator sample in its native state and one that had been exposed to hydrogen. DetecTape is a self-adhesive silicone-based tape impregnated with a proprietary hydrogen-sensitive indicator based on transition metal oxides. A length of the tape can be cut from the roll and stretched by a factor of two or three times around a fitting. Due to the self-adhesive property of the tape, this provides a tight seal around the fitting. The seal is not hermetic, and is not intended to prevent the release of a leaking gas. However, a portion of the hydrogen leaking from a wrapped fitting will pass through the tape and react with the active indicator impregnated within the tape, thereby inducing blackening.

08 HYDROGEN↗

Aero-MINE (Motionless INtegrated Energy) for Distributed Scalable Wind Power.

The proposed Aero-MINE technology will extract energy from wind without any exterior moving parts. Aero-MINEs can be integrated into buildings or function stand-alone, and are scalable. This gives them advantages similar to solar panels, but with the added benefit of operation in cloudy or dark conditions. Furthermore, compared to solar panels, Aero-MINEs can be manufactured at lower cost and with less environmental impact. Power generation is isolated internally by the pneumatic transmission of air and the outlet air-jet nozzles amplify the effectiveness. Multiple units can be connected to one centrally located electric generator. Aero-MINEs are ideal for the built-environment, with numerous possible configurations ranging from architectural integration to modular bolt-on products. Traditional wind turbines suffer from many fundamental challenges. The fast-moving blades produce significant aero-acoustic noise, visual disturbances, light-induced flickering and impose wildlife mortality risks. The conversion of massive mechanical torque to electricity is a challenge for gears, generators and power conversion electronics. In addition, the installation, operation and maintenance of wind turbines is required at significant height. Furthermore, wind farms are often in remote locations far from dense regions of electricity customers. These technical and logistical challenges add significantly to the cost of the electricity produced by utility-scale wind farms. In contrast, distributed wind energy eliminates many of the logistical challenges. However, solutions such as micro-turbines produce relatively small amounts of energy due to the reduction in swept area and still suffer from the motion-related disadvantages of utility-scale turbines. Aero-MINEs combine the best features of distributed generation, while eliminating the disadvantages.

17 WIND ENERGY↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Interim Report

The Graphite Technology Development Program is running a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. The fourth experiment, Advanced Graphite Creep 4 (AGC 4), began with Advanced Test Reactor (ATR) cycle 157D on May 30, 2015, and has been irradiated for two cycles. The capsule was removed from the reactor after ATR cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation will resume when the interfering experiment is removed from the reactor. This report documents qualification of AGC 4 experiment irradiation monitoring data for use by the Advanced Reactor Technologies (ART) Technology Development Office (TDO) Program for research and development activities required to design and license the first HTR nuclear plant. Qualified data meet the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements, but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. All temperature data are Qualified for use by the ART TDO Program. Argon, helium, and total gas flow data were within expected ranges and are Qualified for use by the ART TDO Program. Discharge gas line moisture values were consistently low during cycle 157D. At the start of cycle 158A, gas moisture briefly spiked to over 600 ppmv and then declined throughout the cycle. Moisture values are within the measurement range of the instrument and are Qualified for use by the ART TDO Program. Graphite creep specimens were subjected to one of three loads, 393, 491, or 589 lbf. For a brief period during cycle 157D between 12:19 on June 2, 2015 and 08:23 on June 11, 2015 the load cells were wired incorrectly resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use, but must be taken into account when analyzing the effect of load on creep. Stack displacement increased consistently throughout the first two cycles with total displacement ranging from 0.4 to 0.8 in. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed twice. All stacks were raised successfully each time. The load and displacement data are Qualified for use by the ART TDO Program.

36 MATERIALS SCIENCE↗

Metal Bellows Valve Reliability Testing

Swagelok B ® series metal bellows-sealed valves were tested for their cycle performance longevity to evaluate their use in tritium service. The valves selected differed in the size of their pneumatic actuator and the stem tip material. Valves tested had one of three actuator sizes (1C, 3C, or 5C) and one of two stem tip materials: a cobalt-based metal, Stellite™, and a polyimide material, Vespel ® . An automated valve manifold was constructed, allowing for the simultaneous cycling of a total of 10 valves. Automation controls allowed for user inputs, controlling the number of valve cycles per test and the number of tests per experiment. Valves installed on the valve testing manifold to be cycled following a valve frequency test plan. After a defined number cycles, the valves would undergo leak testing using an inline leak detector. The inline helium leak detector provided qualitative detection of any failing or failed valves. If a valve had failed, a leak rate greater than at 1.0 x 10 -7 std cc He/sec, the valve would be removed from the manifold and quantitative leak rate measurements made. After specific cycling milestones were reached, quantitative valve leak rate measurements were performed to assess the adequacy of the qualitative measurement method. Valve evaluation began with initial leak tests: valve inlet/outlet seat rates and total body leak rate. The as received 1C valves, with PTFE stem tips, passed initial leak tests; however, stem tips replacements with either metal or polyimide stem tips essentially created valves which failed subsequent leak tests and were not subject to valve cycling. The 3C actuated valves had been cycled 150,000 times, resulting in 60% of the Stellite™ and Vespel ® tipped valves still passing the leak rate criteria. Failure analysis on the other 40% has yet to be conducted. Eight of the 5C valves had reached 150,000 cycles with 80% of the valves passing the leak rate criteria: two Vespel ® tipped 5C valves failed leak rate testing after 120,000 cycles.

36 MATERIALS SCIENCE↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects; from coding an Arduino to building PVC piping to 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into/out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects such as coding an Arduino, building PVC piping, and 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into and out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled or pushed through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point. These times, as well as the temperatures, are the data necessary for the project and must be extremely accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiological Handling and Containment Considerations in Support of an American Medical Isotope Producer

This work will discuss evaluation and design of new and modified facility level radiological containment, transfer, and handling systems in support of the United States’ American Medical Isotope Production Act. In the United States alone, Molybdenum-99 (Mo-99) is used as a precursor to locally generate its decay product, technetium-99m (Tc-99m), for use in approximately 40,000 medical procedures every day to detect cancer and heart disease. Currently, however, Mo-99 is primarily produced overseas and typically requires highly enriched uranium (HEU) which is classified as weapon -usable. This poses a serious security risk to the United States and, in 2012, Congress passed the American Medical Isotope ACT which aimed to cease all Mo-99 production that requires HEU and support American based companies who have found safer production methods. Through this effort, a system was designed and developed to access irradiated material in processing hot cells for ease of material introduction and removal in the confined area. The proposed solution uses a double-door design that allows for easy access to material while also providing shielding through a mechanically manipulated carousel. A system was also designed to transport irradiated materials from target reactors to a target receipt box using a rail guide system, pneumatic motor, and lead screw drive.

07 ISOTOPE AND RADIATION SOURCES↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗