Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Photogrammetry of the Map Instrument in a Cryogenic Vacuum Environment

MAP Instrument requirements dictated that the instruments Focal Plane Assembly (FPA) and Thermal Reflector System (TRS) maintain a high degree of structural integrity at operational temperatures (< 50K). To verify integrity at these extremes, an elaborate test fixture was constructed to provide a large cryogenic (< 20K) radiative environment and a mobile photogrammetry camera. This paper will discuss MAP's Instrument requirements, how those requirements were verified using photogrammetry, and the test setup used to provide the environment and camera movement needed to verify the instrument's requirements.

Hill, M.↗

MACS, An Instrument, and a Methodology for Simulations and Global Measurements of the Coronal Electron Temperature and the Solar Wind Velocity on the Solar Corona

The determination of the radial and latitudinal temperature and wind profiles of the solar corona is of great importance in understanding the coronal heating mechanism and the dynamics of coronal expansion. Cram presented the theory for the formation of the K-coronal spectrum and identified two important observations. He observed the existence of temperature sensitive anti-nodes at certain wavelengths in the theoretical K-coronal spectra. The anti-nodes are separated by temperature-insensitive nodes. Remarkably, Cram showed that the wavelengths of the nodes and anti-nodes are almost independent of altitude above the solar limb. Because of these features, Cram suggested that the intensity ratios at two anti-nodes could be used as a diagnostic of the electron temperature in the K-corona. Based on this temperature diagnostic technique prescribed by Cram a slit-based spectroscopic study was performed by Ichimoto et al. on the solar corona in conjunction with the total solar eclipse of 3 Nov 1994 in Putre, Chile to determine the temperature profile of the solar corona. In this thesis Cram's theory has been extended to incorporate the role of the solar wind in the formation of the K-corona, and we have identified both temperature and wind sensitive intensity ratios. The instrument, MACS, for Multi Aperture Coronal Spectrometer, a fiber optic based spectrograph, was designed for global and simultaneous measurement of the thermal electron temperature and the solar wind velocity in the solar corona. The first ever experiment of this nature was conducted in conjunction with the total solar eclipse of 11 Aug 1999 in Elazig, Turkey. In this instrument one end of each of twenty fiber optic tips were positioned in the focal plane of the telescope in such a way that we could observe conditions simultaneously at many different latitudes and two different radial distances in the solar corona. The other ends of the fibers were vertically aligned and placed at the primary focus of the collimating lens of the spectrograph to obtain simultaneous and global spectra on the solar corona. By isolating the K-coronal spectrum from the spectrum recorded by each fiber the temperature and the wind sensitive intensity ratios were calculated to obtain simultaneous and global measurements of the thermal electron temperature and the solar wind velocity. We were successful in obtaining reliable estimates of the coronal temperature at many positions in the corona. This is the first time that simultaneous measurements of coronal temperatures have been obtained at so many points. However due to instrumental scattering encountered during observations, reliable estimates of the wind velocity turned out to be impossible to obtain. Although remedial measures were taken prior to observation, this task proved to be difficult owing to the inability to replicate the conditions expected during an eclipse in the laboratory. The full extent of the instrumental scattering was apparent only when we analyzed the observational sequence. Nevertheless the experience obtained from this very first attempt to simultaneously and globally measure both the wind velocity and the temperature on the solar corona have provided valuable information to conduct any future observations successfully.

Reginald, Nelson L.↗

Optimizing Orbit-Instrument Configuration for Global Precipitation Mission (GPM) Satellite Fleet

Following the scientific success of the Tropical Rainfall Measuring Mission (TRMM) spearheaded by a group of NASA and NASDA scientists, their external scientific collaborators, and additional investigators within the European Union's TRMM Research Program (EUROTRMM), there has been substantial progress towards the development of a new internationally organized, global scale, and satellite-based precipitation measuring mission. The highlights of this newly developing mission are a greatly expanded scope of measuring capability and a more diversified set of science objectives. The mission is called the Global Precipitation Mission (GPM). Notionally, GPM will be a constellation-type mission involving a fleet of nine satellites. In this fleet, one member is referred to as the "core" spacecraft flown in an approximately 70 degree inclined non-sun-synchronous orbit, somewhat similar to TRMM in that it carries both a multi-channel polarized passive microwave radiometer (PMW) and a radar system, but in this case it will be a dual frequency Ku-Ka band radar system enabling explicit measurements of microphysical DSD properties. The remainder of fleet members are eight orbit-synchronized, sun-synchronous "constellation" spacecraft each carrying some type of multi-channel PMW radiometer, enabling no worse than 3-hour diurnal sampling over the entire globe. In this configuration the "core" spacecraft serves as a high quality reference platform for training and calibrating the PMW rain retrieval algorithms used with the "constellation" radiometers. Within NASA, GPM has advanced to the pre-formulation phase which has enabled the initiation of a set of science and technology studies which will help lead to the final mission design some time in the 2003 period. This presentation first provides an overview of the notional GPM program and mission design, including its organizational and programmatic concepts, scientific agenda, expected instrument package, and basic flight architecture. Following this introduction, we focus specifically on the last topic, that being an analysis which leads to an optimal flight architecture dictated in part by science requirements but constrained by allowable orbital mechanics, instrument scan patterns, and antenna aperture properties. Because the optimal architecture involves an interplay between orbit mechanics and instrument specifications, it is important to recognize that in attempting to serve various scientific themes, the final optimal architecture will represent a compromise concerning dynamic range, spatial resolution, sampling interval, pointing, beam coincidence, and measurement uncertainty. Moreover, cost becomes a major factor in seeking the optimal architecture through the pathways of antenna and instrument scan designs, as well as propulsion requirements associated with the orbit heights of various "constellation" members. Although the results presented at the IGARSS-2001 meeting will likely not be the fully refined flight architecture specifications, they are expected to be nearly complete.

Smith, Eric A.↗

Use of the Aromascan(TM) Instrument for Nonsubjective Evaluation of Rodent Spaceflight Hardware

This report describes the verification and utilization of the AromaScan(TM) (Hollis, NH) instrument for the ground-based evaluation of odor containment by various spaceflight habitats developed at NASA's Ames Research Center (ARC). The AromaScan(TM) instrument is an electronic odor detection system consisting of 32 polymer sensors that respond differentially to 10 different chemical groups present in an air sample. The AromaScan(TM) system also includes neural network software for constructing a database of known odors, against which an unknown odor can be compared. At present, the standard method for characterizing rodent odor containment during the development and testing of spaceflight hardware is the use of a human odor assessment panel. However, this can be a very time consuming and costly process, and the results are inherently subjective. The AromaScan(TM) system should produce more consistent and objective results, as well as a cost savings in the long term. To test and verify the AromaScan(TM) instrument, daily air samples will be collected from the exhaust port of rodent habitats, during experiment development tests, then injected into the instrument and used to create a database of recognizable odors. Human sniff tests will be performed in conjunction with the AromaScan(TM) analysis, and the results will be correlated. We will then teach the neural network to differentiate between an acceptable and an unacceptable odor profile, as defined by the human sniff test, and to be able to accurately identify an odor that would not pass a sniff panel. The results of our efforts will be to verify that the AromaScan(TM) system is a valuable alternative to human sniff panel assessments for the early iterative process of designing and testing rodent waste filters for spaceflight. Acceptance by a human panel will remain one of the final criteria for successful rodent habitat development.

Scribner, K. A.↗

Calibration of a Computer Based Instrumentation for Flight Research

NASA Ames Research Center has been investigating a Differential Global Positioning System (DGPS) for future use as a Category II/III landing system. The DGPS navigation system was developed and installed on a B200 King Air aircraft. Instrumentation that is not calibrated and verified as a total operating system can have errors or not work correctly. Systems need to be checked for cross talk and that they work together accurately. It is imperative that the instrumentation and computer do not affect aircraft avionics and instrumentation needed for aircraft operation. This paper discusses calibration and verification principles of a computer based instrumentation airborne system.

Forsyth, T. J.↗

Monitoring of Observation Errors from Satellite Ozone Instruments in Assimilation

Ozone distributions derived from the Solar Backscatter UltraViolet/2 (SBUV/2) instruments and the Earth Probe Total Ozone Mapping Spectrometer (EP TOMS) have been assimilated in near-real time at the NASA/Goddard Data Assimilation Office since January 2000. Observed-minus-forecast (O-F) residuals are the differences between the incoming ozone data and the co-located short-term model forecast. They are routinely produced and monitored in the assimilation process. Using examples from the NOAA-14 and NOAA-16 SBUV/2 and the EP-TOMS instruments, it is demonstrated that the monitoring of time series of O-F residual statistics is an effective method of identifying time-dependent changes in the observation-error characteristics of ozone. In addition, the data assimilation system was used to assist the validation of updated calibration coefficients for the NOAA-14 SBUV/2 instrument. This assimilation-based monitoring work will be extended to ozone data from instruments on new satellites: Envisat EOS, Aqua, and EOS Aura.

Stajner, Ivanka↗

Comparison of Global Distributions of Zonal-Mean Gravity Wave Variance Inferred from Different Satellite Instruments

Gravity wave temperature fluctuations acquired by the CRISTA instrument are compared to previous estimates of zonal-mean gravity wave temperature variance inferred from the LIMS, MLS and GPS/MET satellite instruments during northern winter. Careful attention is paid to the range of vertical wavelengths resolved by each instrument. Good agreement between CRISTA data and previously published results from LIMS, MLS and GPS/MET are found. Key latitudinal features in these variances are consistent with previous findings from ground-based measurements and some simple models. We conclude that all four satellite instruments provide reliable global data on zonal-mean gravity wave temperature fluctuations throughout the middle atmosphere.

Preusse, Peter↗

Cordless Instruments

Black & Decker's new cordless lightweight battery powered precision instruments, adapted from NASA's Apollo Lunar Landing program, have been designed to give surgeons optimum freedom and versatility in the operating room. Orthopedic instrument line includes a drill, a driver/reamer and a sagittal saw. All provide up to 20 minutes on a single charge. Power pack is the instrument's handle which is removable for recharging. Microprocessor controlled recharging unit can recharge two power packs together in 30 minutes. Instruments can be gas sterilized, steam-sterilized in an autoclave or immersed for easy cleaning.

Source record↗

Early Radiometric Validation Results of the Ceres Flight Model 1 and 2 Instruments Onboard NASA's Terra Spacecraft

The CERES Flight Model 1 and 2 instruments were launched aboard NASA's Earth Observing System (EOS) Terra Spacecraft on December 18, 1999 into a 705 Km sun-synchronous orbit with a 10:30 a.m. equatorial crossing time. These instruments supplement measurements made by the CERES Proto Flight Model (PFM) instrument launched aboard NASA's Tropical Rainfall Measuring Mission (TRMM) spacecraft on November 27, 1997 into a 350 Km, 38-degree mid-inclined orbit. An important aspect of the EOS program is the rapid archival and dissemination of datasets measured by EOS instruments to the scientific community. On September 22, 2000 the CERES Science Team voted to archive the Edition 1 CERES/Terra Level 1b and Level 2 and 3 ERBE-Like data products. These products consist of instantaneous filtered and unfiltered radiances through temporally and spatially averaged TOA fluxes. CERES filtered radiance measurements cover three spectral bands including shortwave (0.3 to 5 micron), total (0.3 to less than 100 microns) and an atmospheric window channel (8 to 12 microns). The current work summarizes both the philosophy and results of validation efforts undertaken to quantify the quality of the Terra data products as well as the level of agreement between the Terra and TRMM datasets.

Priestley, K. J.↗

AIR Instrument Array

The large number of radiation types composing the atmospheric radiation requires a complicated combination of instrument types to fully characterize the environment. A completely satisfactory combination has not as yet been flown and would require a large capital outlay to develop. In that the funds of the current project were limited to essential integration costs, an international collaboration was formed with partners from six countries and fourteen different institutions with their own financial support for their participation. Instruments were chosen to cover sensitivity to all radiation types with enough differential sensitivity to separate individual components. Some instruments were chosen as important to specify the physical field component and other instruments were chosen on the basis that they could be useful in dosimetric evaluation. In the present paper we will discuss the final experimental flight package for the ER-2 flight campaign.

Jones, I. W.↗

Precision Select Mechanisms for the GLAS and SOLSE2 Instruments

The Geoscience Laser Altimeter System (GLAS) instrument had requirements for a 2-position mechanism to rotate mirrors into and out of the optical path of the altimetry detectors and the lasers. The Solar Ozone Limb Sounding Experiment II (SOLSE2) instrument had a similar requirement of rotating a visible (VIS) or ultraviolet (W) filter into the instrument optical path. Both GLAS and SOLSE2 had similar operational and survival environments and lifetime requirements. A novel, precision rotational latching mechanism was designed to fulfill the needs of both missions. The GLAS instrument had driving stability and repeatability requirements, such that if the mechanism met these stringent requirements, it would more than surpass the required performance for the SOLSE2 mechanism. The resulting mechanism, referred to as a 'select mechanism' since it allows selection between 2 positions, was successfully designed and implemented for both missions.

Budinoff, Jason G.↗

AGE (Argon Geochronology Experiment): An Instrument for Geochronology on the Surface of Mars

As our knowledge of the planet Mars continues to grow, one parameter that remains elusive is the absolute chronology of the planet s geological history. Although crater counts have provided a robust relative chronology, impactor fluxes are poorly enough known that there are places on Mars where the absolute age is uncertain by a factor of two or more. To resolve these uncertainties, it will be necessary to either analyze well-documented samples returned to the Earth from the Martian surface or to perform in situ measurements with sufficient precision. Sample return is still at least a decade away, and even then it might be from a biologically interesting area that might be geologically complex. Hence an in situ measurement, within an uncertainty of 20% or better, could greatly improve our knowledge of the history of Mars. With funding from the Planetary Instrument Definition and Development Program (PIDDP), we have been working on an instrument to perform potassium-argon (K-Ar) and cosmic-ray exposure (CRE) dating in situ on the surface of Mars. For either of these techniques, it is necessary to measure the abundance of one or more major or minor elements (K in the case of KAr; all majors and minors in the case of CRE) and the abundance and isotopes composition of a noble gas (Ar in the case of K-Ar; He, Ne and Ar for CRE dating). The technology for either of these types of measurements exists, but has never before been integrated for a spacecraft. We refer to the instrument as AGE, the Argon Geochronology Experiment (although we will measure the noble gases He and Ne as well for CRE ages). We report here on the basic components that go into such an instrument, both those that use existing technology and those that had to be developed to create the integrated package.

Swindle, T. D.↗

Measuring Aerosol Optical Properties with the Ozone Monitoring Instrument (OMI)

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to the NASA EOS-Aura mission scheduled for launch in January 2004. OM1 is an imaging spectrometer that will measure the back-scattered Solar radiance between 270 an 500 nm. With its relatively high spatial resolution (13x24 sq km at nadir) and daily global coverage. OM1 will make a major contribution to our understanding of atmospheric chemistry and to climate research. OM1 will provide data continuity with the TOMS instruments. One of the pleasant surprises of the TOMS data record was its information on aerosol properties. First, only the absorbing aerosol index, which is sensitive to elevated lay- ers of aerosols such as desert dust and smoke aerosols, was derived. Recently these methods were further improved to yield aerosol optical thickness and single scattering albedo over land and ocean for 19 years of TOMS data (1979-1992,1997-2002), making it one of the longest and most valuable time series for aerosols presently available. Such long time series are essential to quantify the effect of aerosols on the Earth& climate. The OM1 instrument is better suited to measure aerosols than the TOMS instruments because of the smaller footprint, and better spectral coverage. The better capabilities of OMI will enable us to provide an improved aerosol product, but the knowledge will also be used for further analysis of the aerosol record from TOMS. The OM1 aerosol product that is currently being developed for OM1 combines the TOMS experience and the multi-spectral techniques that are used in the visible and near infrared. The challenge for this new product is to provide aerosol optical thickness and single scattering albedo from the near ultraviolet to the visible (330-500 nm) over land and ocean. In this presentation the methods for deriving the OM1 aerosol product will be presented. Part of these methods developed for OM1 can already be applied to TOMS data and results of such analysis will be shown.

Veefkind, J. P.↗

The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and cryostat) which is the subject of this paper.

Whitehouse, Paul L.↗

The James Webb Telescope Instrument Suite Layout: Optical System Engineering Considerations for a Large, Deployable Space Telescope

The James Webb Space Telescope (JWST) is a space-based, infrared observatory designed to study the early stages of galaxy formation in the Universe. The telescope will be launched into an elliptical orbit about the second Lagrange point and passively cooled to 30-50 K to enable astronomical observations from 0.6 to 28 microns. A group from the NASA Goddard Space Flight Center and the Northrop Grumman Space Technology prime contractor team has developed an optical and mechanical layout for the science instruments within the JWST field of view that satisfies the telescope s high-level performance requirements. Four instruments required accommodation within the telescope's field of view: a Near-Infrared Camera (NIRCam) provided by the University of Arizona; a Near-Mared Spectrometer (NIRSpec) provided by the European Space Agency; a Mid-Infrared Instrument (MIRI) provided by the Jet Propulsion Laboratory and a European consortium; and a Fine Guidance Sensor (FGS) with a tunable filter module provided by the Canadian Space Agency. The size and position of each instrument's field of view allocation were developed through an iterative, concurrent engineering process involving the key observatory stakeholders. While some of the system design considerations were those typically encountered during the development of an infrared observatory, others were unique to the deployable and controllable nature of JWST. This paper describes the optical and mechanical issues considered during the field of view layout development, as well as the supporting modeling and analysis activities.

Bos, Brent↗

Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

Chipera, S. J.↗

Determining the Relationship between the Total and Window Channel Nighttime Radiances for the CERES Instrument

Observing Earth s radiant energy budget from space is critical to improving our understanding of Earth s climate system. The Earth Radiation Budget Experiment (ERBE) was the first initiative to provide simultaneous observations of Earth s radiant energy with identical instruments flying aboard separate satellites. The design of the ERBE instrument was based upon three complementary broadband radiometers which measured the shortwave (< 5 mm), longwave (> 5 mm), and total regions of the spectrum. Since any two of the ERBE radiometers could be used to simulate the third, a three channel intercomparison, based on redundancy, was available to uncover any changes in the relative sensitivities of the individual radiometers. Such a three channel intercomparison thus provided confidence in the application of the ERBE measurements over the lifetime of the instrument while mitigating the concern over instrument degradation.

Kratz, David P.↗

Polarization Ray Trace Model of the MODIS Instrument

Sunlight reflected from the earth is, to a certain extent, polarized. Radiometers, such as the MODIS instrument on board the TERRA and AQUA spacecraft, are to a certain extent polarizers. Accurate radiometric measurements must take into account both the polarization state of the scene and the polarization sensitivity of the measuring instrument. The measured polarization characteristics of the MODIS instruments are contained in various radiometric models. Continued use of these radiometric math models, over a number of years, have shown where these models can be improved. Currently a MODIS polarization ray trace model has been created which models the thin film structure on the optical elements. This approach is described and modeled and measured instrument polarization sensitivity results presented.

Waluschka, Eugene↗