Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Data Sensitivities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

239 Pu(n,f) Neutron Multiplicity Evaluation with CGMF-Very First Release Candidate. [Slides]

239 Pu(n,f) nu-bar evaluated with CGMF from E inc = 0.1-20 MeV. Changes compared to VIII.0: Prior: CGMF model included via Kalman and sensitivities of CGMF model parameters to nu-bar. Evaluation technique: Kalman including correction for PPP. Experimental data: Nearly all data that Phil took into account (I rejected: Huanqiao, Johnstone, Leroy, Nesterov, Smirenkin); New UQ for all experimental data; Marini; No correlations between unc. of different exp., except for Cf-252(sf) nu-bar uncertainty cross-correlating all uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Isomeric Yield Ratios of fission products: a missing piece in reactor antineutrino summation calculations

The calculation of the spectrum of antineutrinos ( $\overline{V}$ e ) from a reactor is a complicated problem requiring several nuclear data and physics inputs. Many of these have been investigated thoroughly to improve calculations and properly account for uncertainties. One input which has heretofore escaped consideration is the fission yield distribution between ground and isomeric states. In this work, we explore the effect of incorporating newly evaluated isomeric yield ratios (IYR) for 43 fission products into summation calculations and identify the disproportionate importance of certain isotopes, particularly at higher energies. Our analysis indicates that updated IYRs contribute to a significant increase in the $\overline{V}$ e spectrum around and above 7 MeV, with increases of more than 50% at higher energies. Through a detailed sensitivity study, we highlight a number of isotopes for which the IYR has a substantial effect on the $\overline{V}$ e spectrum. This work stresses the critical role of isomeric yields in calculations of reactor $\overline{V}$ e spectra and points to the necessity for their accurate experimental determination, especially for key fission products, in order to refine our understanding and address the observed anomalies between measured and calculated $\overline{V}$ e spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Life Cycle Analysis Framework for Point Source Capture Systems

NETL studies the costs and benefits of PSC for electricity, industry, and mobile applications. Mobile point source capture (MPSC) and storage applied to freight modes captures emissions directly from exhaust. This poster presents a framework for conducting LCA of PSC systems applied to heavy-duty trucks, freight trains, and marine vessels. The framework defines a wheels-to-storage (gate-to-grave) boundary, including energy demands (electricity, heat, and cooling requirements), solvent use and cycling, onboard system components, carbon storage in a saline aquifer, and upstream manufacturing impacts for equipment, with a suggested functional unit of 1 tonne-km. Potential data sources for analysis include material, energy, and operational data from Oak Ridge National Laboratory, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, and scientific literature. The suggested analytical approach includes comparison to publicly available business-as-usual systems without capture across all modes of transportation, sensitivity to composition of the capture solvent, and sensitivity to capture rate variation, all of which would support a wholistic PSC business case analysis. For future consideration, analysis can be augmented with consideration of different sources of electricity (e.g., nuclear), fuel substitution, deploying supportive infrastructure such as pipeline offloading points, and downstream applications like enhanced oil recovery (EOR).

life cycle analysis (LCA)↗

Simultaneous isotopic analysis of fission product Sr, Mo, and Ru in spent nuclear fuel particles by resonance ionization mass spectrometry

Abstract Fission product Sr, Mo, and Ru isotopes in six 10-μm particles of spent fuel from a pressurized water reactor were analyzed by resonance ionization mass spectrometry (RIMS) and evaluated for utility in nuclear material characterization. Previous measurements on these same samples showed widely varying U, Pu, and Am isotopic compositions owing to the samples’ differing irradiation environments within the reactor. This is also seen in Mo and Ru isotopes, which have the added complication of exsolution from the UO 2 fuel matrix. This variability is a hindrance to interpreting data from a collection of particles with incomplete provenance since it is not always possible to assign particles to the same batch of fuel based on isotopic analyses alone. In contrast, the measured 90 Sr/ 88 Sr ratios were indistinguishable across all samples. Strontium isotopic analysis can therefore be used to connect samples with otherwise disparate isotopic compositions, allowing them to be grouped appropriately for interpretation. Strontium isotopic analysis also provides a robust chronometer for determining the time since fuel irradiation. Because of the very high sensitivity of RIMS, only a small fraction of material in each of the 10 μm samples was consumed, leaving the vast majority still available for other analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of NuScale SMR Steam Heat Augmentation for Chemical Plant Decarbonization

Nearly 50% of the total energy consumed by the industrial sector in the United States is used to produce process steam with natural gas and coal-fired boilers1 . This project conducts a technoeconomic assessment of a NuScale Small Modular Reactor (SMR) coupled with a chemical plant as an Integrated Energy System (IES) where nuclear produces steam and electric power to meet the requirements of a large chemical plant. In a 2020 study, ORNL evaluated the feasibility of using advanced SMRs, including the NuScale design, to supply energy to the Eastman Chemical Plant. However, since that report was published, NuScale received NRC approval for its uprated 77 MWe design with 56% more power and has also introduced a high-temperature, high pressure, steam heat-augmentation system, a key focus of the new study. The new study also benefits from revised capital costs, a 10-day refueling outage time, reduced plant staffing, higher capacity factors, and a site boundary Emergency Planning Zone methodology. The study consists of a techno-economic assessment of two possible energy sources (nuclear and natural gas) in a number of steam and power generation configurations (NuScale Power Modules (NPMs), boilers and combinations of both) to satisfy the steam and power demand with the most reliable and cost competitive system. A total of 2,947.3 klb/hr of steam and 72.5 MWe of electricity are required for the demonstration case. A range of scenarios and solutions are explored, from a 12-NPM plant (3,000 MWth)—with excess capacity and redundancy, capable of supplying a significant amount of extra power to the grid—to a 4-NPM (1,000 MWth) plant—supplemented with existing boilers or grid power for redundancy. The study uses historical steam and power data from a chemical plant and examines the sensitivity to natural gas and grid power cost variations. Scenarios with up to two times gas and electricity costs were considered. Profitability in a 60-year time horizon was analyzed, consistent with NuScale’s design life specification. A steady-state site integration and reliability analysis was performed, and trade-offs were identified.

20 FOSSIL-FUELED POWER PLANTS↗

Driving mode analysis—How uncertain functional inputs propagate to an output

Abstract Driving mode analysis elucidates how correlated features of uncertain functional inputs jointly propagate to produce uncertainty in the output of a computation. Uncertain input functions are decomposed into three terms: the mean functions, a zero‐mean driving mode, and zero‐mean residual. The random driving mode varies along a single direction, having fixed functional shape and random scale. It is uncorrelated with the residual, and under linear error propagation, it produces an output variance equal to that of the full input uncertainty. Finally, the driving mode best represents how input uncertainties propagate to the output because it minimizes expected squared Mahalanobis distance amongst competitors. These characteristics recommend interpretation of the driving mode as the single‐degree‐of‐freedom component of input uncertainty that drives output uncertainty. We derive the functional driving mode, show its superiority to other seemingly sensible definitions, and demonstrate the utility of driving mode analysis in an application. The application is the simulation of neutron transport in criticality experiments. The uncertain input functions are nuclear data that describe how Pu reacts to bombardment by neutrons. Visualization of the driving mode helps scientists understand what aspects of correlated functional uncertainty have effects that either reinforce or cancel one another in propagating to the output of the simulation.

97 MATHEMATICS AND COMPUTING↗

Investigating Similarity Differences for Light-Water-Moderated and Polyethylene-Moderated Systems [Slides]

Validation efforts revealed noticeable differences in c k for light-water and polyethylene moderated systems when compared to experimental systems. Although 1 H-H 2 O and 1 H-poly use some of the same cross section and identical covariance data, the treatment of TSLs in SCALE lead to no contribution to c k between polyethylene application and benchmark experiment. When H 2 O contribution is removed the difference in c k appears to come from 239 Pu chi. Sensitivity profiles and data-induced uncertainty confirm that the polyethylene application more closely resembles the benchmark experiment. Interrogation techniques were used to observe how TSLs and nuclide IDs affect c k . Specific differences between similar systems can be accounted for and examined to help understand differences in similarity (c k ) between systems

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanoindentation Stress Relaxation to Quantify Dislocation Velocity–Stress Exponent

This work reports a new methodology using indentation stress relaxation to characterize the dislocation velocity–stress exponent. Through the indentation stress relaxation process, the dislocation structure builds up at the rate governed by dislocation velocity, which is a function of the externally applied stress. The relationship between the dislocation velocity and stress can thus be derived from the indentation stress relaxation data of the stress as a function of time. In this study, instrumented nanoindentation stress relaxation experiments were performed on pure aluminum samples, following three different initial displacement rates of 100, 400, and 800 nm/s. Based on the scaling properties of dislocation kinetics, the data were interpreted to derive a dislocation velocity–stress exponent of 2.5 ± 0.5 for room-temperature aluminum. Crystal plasticity finite-element simulations were performed to illustrate the sensitivity of the proposed nanoindentation stress relaxation methodology to the dislocation velocity–stress exponent value.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of Neutron Yield from (α, n) Reactions: Data, Methods, and Prospects

Understanding the radiogenic neutron production rate through the (α, n) reaction is crucial in many areas of physics, including dark matter searches, neutrino studies, and nuclear astrophysics. In addition to its relevance for fundamental research, the (α, n) reaction also plays a significant role in nuclear energy technologies, for example by contributing to neutron production in subcritical systems using UO2, as well as in applications such as medical physics. This review examines the current state of (α, n) yield calculations and neutron spectra, describes the computational tools used for their estimation, and discusses the available cross-section data. We discuss the uncertainties affecting (α, n) yield estimations and propose a strategy to enhance their accuracy. Furthermore, this paper discusses and emphasizes the need for new measurements of (α, n) cross-sections for a variety of relevant materials. Such measurements are essential for improving neutron flux predictions, which are crucial for reducing uncertainties in sensitivity estimates for next-generation physics experiments operating in the keV—MeV range.

(α, n)reactions↗

A study of the radiation environment on board the space shuttle flight STS-57

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Badhwar, G. D.↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting High Energy Arcing Fault Zones of Influence for Aluminum Using an Arc Flash Modeling Approach: Evaluation of a model bias, uncertainty, parameter sensitivity and zone of influence estimation

This report documents the development of an arc flash hazard model to calculate the incident energy and zone of influence from high energy arcing faults involving aluminum. The NRC has identified the potential for (HEAFs) involving aluminum to increase the damage zone beyond what is currently postulated in fire probabilistic risk assessment (PRA) methodologies. To estimate the hazard from HEAFs involving aluminum an arc flash model was developed. Differences between the initial model and nuclear power plant (NPP) fire PRA scenarios were identified. Modification of the initial model established from existing literature and test data was used to minimize these differences. The developed model was evaluated against NRC datasets to understand the model prediction and relative uncertainties. Finally, a range of fire PRA zone of influences (ZOI) were developed based on the developed model, target fragility estimates and update HEAF PRA methodology. The results were developed to support an NRC LIC-504 evaluation in tandem with other modeling efforts. The report documents the effort and provides a reference for any future advancements in arc flash modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commissioning the H i Observing Mode of the Beam Former for the Cryogenically Cooled Focal L-band Array for the GBT (FLAG)

We present the results of commissioning observations for a new digital beam-forming back end for the Focal plane L-band Array for the Robert C. Byrd Green Bank Telescope (FLAG), a cryogenically cooled Phased Array Feed (PAF) with the lowest measured T {sub sys}/η of any PAF outfitted on a radio telescope to date. We describe the custom software used to apply beam-forming weights to the raw element covariances to create research-quality spectral-line images for the new fine-channel mode, study the stability of the beam weights over time, characterize FLAG’s sensitivity over a frequency range of 150 MHz, and compare the measured noise properties and observed distribution of neutral hydrogen emission from several extragalactic and Galactic sources with data obtained with the current single-pixel L-band receiver. These commissioning runs establish FLAG as the preeminent PAF receiver currently available for spectral-line observations on the world’s major radio telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Ultrafast Triplet Pair Separation and Triplet Trapping following Singlet Fission in Amorphous Pentacene Films

In this work, ultrafast infrared and electronic spectroscopy are used to examine the dynamics of triplet pair separation following singlet fission in amorphous and crystalline films of the model singlet fission chromophore, 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-Pn). Direct probing of correlated triplet pair intermediates through their unique vibrational frequencies, infrared electronic transitions, and indirectly through their visible triplet absorptions reveals that triplet pair separation occurs on similar picosecond timescales in both amorphous and crystalline films despite their markedly different average intermolecular coupling strengths. Although triplet pair separation occurs on similar timescales in both environments, measurements of diffusion-controlled triplet-triplet annihilation reveal that the diffusivity of triplet excited states is an order of magnitude lower in amorphous films. The data reveal the presence of sparse triplet traps in the amorphous environment that inhibit the transport of triplet excitons in comparison to crystalline films. These observations inform recent efforts to develop disordered and polymeric singlet fission sensitizers that contain amorphous regions. In particular, the data suggest that it may be possible to nanostructure amorphous or polymeric singlet fission sensitizers to allow ultrafast triplet pair separation and harvesting in photovoltaic and light emitting applications despite their low triplet exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ligand dependent interaction between PC-TP and PPARδ mitigates diet-induced hepatic steatosis in male mice

Phosphatidylcholine transfer protein (PC-TP; synonym StarD2) is a soluble lipid-binding protein that transports phosphatidylcholine (PC) between cellular membranes. To better understand the protective metabolic effects associated with hepatic PC-TP, we generated a hepatocyte-specific PC-TP knockdown (L-Pctp -/- ) in male mice, which gains less weight and accumulates less liver fat compared to wild-type mice when challenged with a high-fat diet. Hepatic deletion of PC-TP also reduced adipose tissue mass and decreases levels of triglycerides and phospholipids in skeletal muscle, liver and plasma. Gene expression analysis suggest that the observed metabolic changes are related to transcriptional activity of peroxisome proliferative activating receptor (PPAR) family members. An in-cell protein complementation screen between lipid transfer proteins and PPARs uncovered a direct interaction between PC-TP and PPARδ that was not observed for other PPARs. We confirmed the PC-TP– PPARδ interaction in Huh7 hepatocytes, where it was found to repress PPARδ-mediated transactivation. Mutations of PC-TP residues implicated in PC binding and transfer reduce the PC-TP-PPARδ interaction and relieve PC-TP-mediated PPARδ repression. Reduction of exogenously supplied methionine and choline reduces the interaction while serum starvation enhances the interaction in cultured hepatocytes. Together our data points to a ligand sensitive PC-TP– PPARδ interaction that suppresses PPAR activity.

59 BASIC BIOLOGICAL SCIENCES↗