Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Note: Production of a mercury beam with an electron cyclotron resonance ion source

An electron cyclotron resonance ion source has been utilized to produce mercury beams with intensities of 4.5 eμA of {sup 202}Hg{sup 29+} and 3.0 eμA of {sup 202}Hg{sup 31+} from natural abundance mercury metal. The production technique relies on the evaporation of liquid mercury into the source plasma vacuum region and utilizes elemental mercury instead of a volatile organic compound as the neutral feed material.

43 PARTICLE ACCELERATORS↗

Note: Design and development of an integrated three-dimensional scanner for atomic force microscopy

A compact scanning head for the Atomic Force Microscope (AFM) greatly enhances the portability of AFM and facilitates easy integration with other tools. This paper reports the design and development of a three-dimensional (3D) scanner integrated into an AFM micro-probe. The scanner is realized by means of a novel design for the AFM probe along with a magnetic actuation system. The integrated scanner, the actuation system, and their associated mechanical mounts are fabricated and evaluated. The experimentally calibrated actuation ranges are shown to be over 1 μm along all the three axes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Near infrared spectral and transient measurements of PbS quantum dots luminescence

We describe an experimental setup for the characterization of luminescence from nanostructures. The setup is intended for steady-state and time-resolved luminescence measurements in the near-infrared region. The setup allows us to study spectral luminescence properties in the spectral range of 0.8–2.0 μm with high spectral resolution and kinetic luminescence properties between 0.8 and 1.7 μm with a time resolution of 3 ns. The capabilities of the system are illustrated by taking luminescence measurements from PbS quantum dots. We established the size dependencies of the optical properties of the PbS quantum dots over a wide spectral range. Finally, the energy transfer process was studied with a high temporal and spectral resolution.

36 MATERIALS SCIENCE↗

Note: A simple model for thermal management in solenoids

We describe a model of the dynamical temperature evolution in a solenoid winding. A simple finite element analysis is calibrated by accurately measuring the thermally induced resistance change of the solenoid, thus obviating the need for accurate knowledge of the mean thermal conductivity of the windings. The model predicts quasi thermal runaway for relatively modest current increases from the normal operating conditions. We demonstrate the application of this model to determine the maximum current that can be safely applied to solenoids used for helium spin-echo measurements.

36 MATERIALS SCIENCE↗

Note: Characteristic beam parameter for the line electron gun

We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

43 PARTICLE ACCELERATORS↗

Note: Hollow cathode lamp with integral, high optical efficiency isolation valve: A modular vacuum ultraviolet source

The design and operating conditions of a hollow cathode discharge lamp for the generation of vacuum ultraviolet radiation, suitable for ultrahigh vacuum (UHV) application, are described in detail. The design is easily constructed, and modular, allowing it to be adapted to different experimental requirements. A thin isolation valve is built into one of the differential pumping stages, isolating the discharge section from the UHV section, both for vacuum safety and to allow lamp maintenance without venting the UHV chamber. The lamp has been used both for ultraviolet photoelectron spectroscopy of surfaces and as a “soft” photoionization source for gas-phase mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Portable rare-earth element analyzer using pyroelectric crystal

We report a portable rare-earth element analyzer with a palm-top size chamber including the electron source of a pyroelectric crystal and the sample stage utilizing cathodoluminescence (CL) phenomenon. The portable rare-earth element analyzer utilizing CL phenomenon is the smallest reported so far. The portable rare-earth element analyzer detected the rare-earth elements Dy, Tb, Er, and Sm of ppm order in zircon, which were not detected by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. We also performed an elemental mapping of rare-earth elements by capturing a CL image using CCD camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: In situ measurement of vacuum window birefringence by atomic spectroscopy

We present an in situ method to measure the birefringence of a single vacuum window by means of microwave spectroscopy on an ensemble of cold atoms. Stress-induced birefringence can cause an ellipticity in the polarization of an initially linearly polarized laser beam. The amount of ellipticity can be reconstructed by measuring the differential vector light shift of an atomic hyperfine transition. Measuring the ellipticity as a function of the linear polarization angle allows us to infer the amount of birefringence Δn at the level of 10{sup −8} and identify the orientation of the optical axes. The key benefit of this method is the ability to separately characterize each vacuum window, allowing the birefringence to be precisely compensated in existing vacuum apparatuses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: An ion source for alkali metal implantation beneath graphene and hexagonal boron nitride monolayers on transition metals

The construction of an alkali-metal ion source is presented. It allows the acceleration of rubidium ions to an energy that enables the penetration through monolayers of graphene and hexagonal boron nitride. Rb atoms are sublimated from an alkali-metal dispenser. The ionization is obtained by surface ionization and desorption from a hot high work function surface. The ion current is easily controlled by the temperature of ionizer. Scanning Tunneling Microscopy measurements confirm ion implantation.

36 MATERIALS SCIENCE↗

Note: Local thermal conductivities from boundary driven non-equilibrium molecular dynamics simulations

We report non-equilibrium molecular dynamics simulations of heat transport in models of molecular fluids. We show that the “local” thermal conductivities obtained from non-equilibrium molecular dynamics simulations agree within numerical accuracy with equilibrium Green-Kubo computations. Our results support the local equilibrium hypothesis for transport properties. We show how to use the local dependence of the thermal gradients to quantify the thermal conductivity of molecular fluids for a wide range of thermodynamic states using a single simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Low energy inverse photoemission spectroscopy apparatus

An apparatus for the low-energy inverse photoemission spectroscopy is described. In this technique, low energy electron having kinetic energy below 4 eV is incident to the sample and detect the emitted photons in the near ultraviolet range (below 5 eV, longer than 250 nm) to investigate the unoccupied states of the solid materials. Compared with the prototype apparatus reported previously [H. Yoshida, Chem. Phys. Lett. 539–540, 180–185 (2012)], the collection efficiency of photons is improved by a factor of four and practically any conductive substrates can be used. The overall resolution is 0.27 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗