Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Node selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Non-destructive simulation of node defects in additively manufactured lattice structures

Additive Manufacturing (AM), commonly referred to as 3D printing, offers the ability to not only fabricate geometrically complex lattice structures but parts in which lattice topologies in-fill volumes bounded by complex surface geometries. However, current AM processes produce defects on the strut and node elements which make up the lattice structure. This creates an inherent difference between the as-designed and as-fabricated geometries, which negatively affects predictions (via numerical simulation) of the lattice’s mechanical performance. Although experimental and numerical analysis of an AM lattice’s bulk structure, unit cell and struts have been performed, there exists almost no research data on the mechanical response of the individual as-manufactured lattice node elements. Here we propose a methodology that, for the first time, allows non-destructive quantification of the mechanical response of node elements within an as-manufactured lattice structure. A custom-developed tool is used to extract and classify each individual node geometry from micro-computed tomography scans of an AM fabricated lattice. Voxel-based finite element meshes are generated for numerical simulation and the mechanical response distribution is compared to that of the idealised computer-aided design model. The method demonstrates compatibility with Uncertainty Quantification methods that provide opportunities for efficient prediction of a population of nodal responses from sampled data. Overall, the non-destructive and automated nature of the node extraction and response evaluation is promising for its application in qualification and certification of additively manufactured lattice structures.

36 MATERIALS SCIENCE↗

The Matrix Metalloproteinase-7 Polymorphism Rs10895304 Is Associated With Increased Recurrence Risk in Patients With Clinically Localized Prostate Cancer

Purpose: To evaluate whether selected high-risk matrix metalloproteinase-7 single nucleotide polymorphisms influence clinicopathologic outcomes in patients with early-stage prostate cancer. Methods and Materials: Two hundred twelve prostate cancer patients treated with radical prostatectomy were evaluated with a median follow-up of 9.8 years. Genotyping was performed using hybridization with custom-designed allele-specific probes. Three single nucleotide polymorphisms within the matrix metalloproteinase-7 gene were assessed with respect to age at diagnosis, margin status, extracapsular extension, lymph node involvement, recurrence-free survival, and overall survival in paraffin-embedded prostate tissue specimens from patients with early-stage prostate cancer who underwent radical prostatectomy. Results: Rs10895304 was the sole significant polymorphism. The A/G genotype of rs10895304 had a statistically significant association with recurrence-free survival in postprostatectomy patients (p = 0.0061, log-rank test). The frequency of the risk-reducing genotype (A/A) was 74%, whereas that of the risk-enhancing genotypes (A/G and G/G) were 20% and 6%, respectively. Multivariable Cox regression analyses detected a significant association between rs10895304 and recurrences after adjustment for known prognostic factors. The G allele of this polymorphism was associated with increased risk of prostate cancer recurrence (adjusted hazards ratio, 3.375; 95% confidence interval 1.567-7.269; p < 0.001). The other assayed polymorphisms were not significant, and no correlations were made to other clinical variables. Conclusions: The A/G genotype of rs10895304 is predictive of decreased recurrence-free survival in patients with clinically localized prostate cancer. Our data suggest that for this subset of patients, prostatectomy alone may not be adequate for local control. This is a novel and relevant marker that should be evaluated for improved risk stratification of patients who may be candidates for adjuvant radiation therapy to improve local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation Using Only Intraoperative Electron Radiation Therapy in Early Stage Breast Cancer

Background: We report the results of a single-institution, phase II trial of accelerated partial breast irradiation (APBI) using a single dose of intraoperative electron radiation therapy (IOERT) in patients with low-risk early stage breast cancer. Methods and Materials: A cohort of 226 patients with low-risk, early stage breast cancer were treated with local excision and axillary management (sentinel node biopsy with or without axillary node dissection). After the surgeon temporarily reapproximated the excision cavity, a dose of 21 Gy using IOERT was delivered to the tumor bed, with a margin of 2 cm laterally. Results: With a mean follow-up of 46 months (range, 28-63 months), only 1 case of local recurrence was reported. The observed toxicity was considered acceptable. Conclusions: APBI using a single dose of IOERT can be delivered safely in women with early, low-risk breast cancer in carefully selected patients. A longer follow-up is needed to ascertain its efficacy compared to that of the current standard treatment of whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating performance and portability of high-level programming models: Julia, Python/Numba, and Kokkos on exascale nodes

We explore the performance and portability of the high-level programming models: the LLVM-based Julia and Python/Numba, and Kokkos on high-performance computing (HPC) nodes: AMD Epyc CPUs and MI250X graphical processing units (GPUs) on Frontier’s test bed Crusher system and Ampere’s Arm-based CPUs and NVIDIA’s A100 GPUs on the Wombat system at the Oak Ridge Leadership Computing Facilities. We compare the default performance of a hand-rolled dense matrix multiplication algorithm on CPUs against vendor-compiled C/OpenMP implementations, and on each GPU against CUDA and HIP. Rather than focusing on the kernel optimization per-se, we select this naive approach to resemble exploratory work in science and as a lower-bound for performance to isolate the effect of each programming model. Julia and Kokkos perform comparably with C/OpenMP on CPUs, while Julia implementations are competitive with CUDA and HIP on GPUs. Performance gaps are identified on NVIDIA A100 GPUs for Julia’s single precision and Kokkos, and for Python/Numba in all scenarios. We also comment on half-precision support, productivity, performance portability metrics, and platform readiness. We expect to contribute to the understanding and direction for high-level, high-productivity languages in HPC as the first-generation exascale systems are deployed.

Godoy, William↗

FY19 Status Report on the Computing Systems for the Yucca Mountain Project TSPA-LA Models and Preliminary Testing of a Selected Process Model

Sandia National Laboratories continued evaluation of total system performance assessment (TSPA) computing systems for the previously considered Yucca Mountain Project. This was done to maintain the operational readiness of the computing infrastructure (computer hardware and software) and knowledge capability for total system performance assessment) type analysis, as directed by the National Nuclear Security Administration (NNSA), DOE 2010. The FY19 task included continued operation of the cluster; maintenance of the TSPA-LA models (with Gold Sim 9.60.300); preliminary assessment of the status of the Infiltration Model (a process model that feeds the TSPA-LA). In addition, precautionary actions were needed to extend the life of the cluster hardware. To do that, three new nodes were added to the cluster. In the event any of the original nodes fail they will be replaced with the new nodes, thereby maintaining the core capability. The 2014 cluster and supporting software systems are currently fully operational to support TSPA-LA type analysis.

97 MATHEMATICS AND COMPUTING↗

A Prospective Randomized Trial to Study the Impact of Pretreatment FDG-PET for Cervical Cancer Patients With MRI-Detected Positive Pelvic but Negative Para-Aortic Lymphadenopathy

Purpose: This prospective randomized study was undertaken to determine the possible impact of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) on extrapelvic metastasis detection, radiation field design, and survival outcome for cervical cancer patients with enlarged pelvic nodes on MRI image. Methods and Materials: Inclusion criteria were patients with newly diagnosed Stage I-IVA cervical cancer and with positive pelvic but negative para-aortic lymph nodes (PALN) as detected by magnetic resonance image and good performance status for concurrent chemoradiotherapy. Eligible patients were randomized to receive either pretreatment FDG-PET (study group) or not (control group). Whole pelvis was the standard irradiation field for the control group and those with no extrapelvic findings on PET. The radiation fields for the rest of the study group were extended to include the PALN region or were modified according to the extrapelvic PET finding. Results: From January 2002 to April 2006, 129 patients were included, and 66 of them were randomized to receive FDG-PET. PET detected seven extrapelvic metastases (11%, 6 PALN and 1 omental node), and four of them remained disease-free after treatment modification. For patients who underwent PET compared with those who did not, there were no differences in the 4-year rates of overall survival (79% vs. 85%, p = 0.65), disease-free survival (75% vs. 77%, p = 0.64), and distant metastasis-free survival (82% vs. 78%, p = 0.83). Conclusions: Pretreatment FDG-PET in conjunction with magnetic resonance imaging can improve the detection of extrapelvic metastasis, mainly PALN, and help select patients for extended-field radiotherapy. However, the addition of FDG-PET may not translate into survival benefit, even though PALN relapses are reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational screening, synthesis and testing of metal–organic frameworks with a bithiazole linker for carbon dioxide capture and its green conversion into cyclic carbonates

Computational crystal construction algorithms were used to create twelve metal–organic frameworks containing a newly synthesized [2,2'-bithiazole]-5,5'-dicarboxylic acid (H 2 TzTz) spacer and assorted transition metal nodes. Among the twelve structures, the zirconium-based MOF of general formula [Zr 6 O 4 (OH) 4 (TzTz) 6 ] (1) was found to be the best candidate for carbon dioxide uptake, as judged from the results of the grand canonical Monte Carlo (GCMC) simulations of CO 2 adsorption isotherms. Guided by the simulation results, 1 was synthesized in the laboratory and thoroughly characterized. 1 is isoreticular to its bithiophene and bis(benzene) (UiO-67) analogues; it crystallizes in the cubic Pn$\bar{3}$ with combining macron] space group with fcu topology, and it features octahedral [Zr 6 ] nodes connected by twelve carboxylate groups from six bridging TzTz 2- spacers. It is a predominantly microporous material (micropore volume = 84% of the total pore volume), with a BET area of 840 m 2 g -1 and a maximum CO 2 uptake at ambient pressure of 2.3 mmol g -1 (10.0 wt%) or 1.7 mmol g -1 (7.5 wt%) at 273 or 298 K, respectively. The CO 2 affinity (isosteric heat of adsorption Qst = 18.7 kJ mol -1 ; CO 2 /N 2 Henry selectivity = 10; CO 2 /N 2 IAST selectivity = 8.4) is similar to that of its bithiophene analogue. After partial removal of solvent (activation), 1 was tested as a heterogeneous catalyst in the reaction of CO 2 with epoxides bearing a –CH 2 X pendant arm (X = Cl: epichlorohydrin; X = Br: epibromohydrin) to give the corresponding cyclic carbonates at T = 393 K and p CO 2 = 1 bar under green (solvent- and co-catalyst-free) conditions. A good conversion of 74% and a turnover frequency of 12.3 mmol (cyclic carbonate) per mmol Zr per h have been recorded with epibromohydrin as a substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient algorithm for locating and sizing series compensation devices in large power transmission grids: I. Model implementation

We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The 'last mile' of data handling: Fermilab's IFDH tools

IFDH (Intensity Frontier Data Handling), is a suite of tools for data movement tasks for Fermilab experiments and is an important part of the FIFE[2] (Fabric for Intensity Frontier [1] Experiments) initiative described at this conference. IFDH encompasses moving input data from caches or storage elements to compute nodes (the 'last mile' of data movement) and moving output data potentially to those caches as part of the journey back to the user. IFDH also involves throttling and locking to ensure that large numbers of jobs do not cause data movement bottlenecks. IFDH is realized as an easy to use layer that users call in their job scripts (e.g. 'ifdh cp'), hiding the low level data movement tools. One advantage of this layer is that the underlying low level tools can be selected or changed without the need for the user to alter their scripts. Logging and performance monitoring can also be added easily. This system will be presented in detail as well as its impact on the ease of data handling at Fermilab experiments.

Lyon, Adam L.↗

A lightweight, user-configurable detector ASIC digital architecture with on-chip data compression for MHz X-ray coherent diffraction imaging

Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionalities from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable detector ASIC digital architecture with on-chip compression which can be implemented in 130 nm technologies in a reasonable area on the ASIC periphery. In addition, we present a design to efficiently handle the variable data from the stream of parallel compressors. The architecture includes user-selectable lossy and lossless compression blocks. The impact of lossy compression algorithms is evaluated on simulated and experimental X-ray ptychography datasets. This architecture is a practical approach to increase pixel detector frame rates towards the continuous 1 MHz regime for not only coherent imaging techniques such as ptychography, but also for other diffraction techniques at X-ray light sources.

47 OTHER INSTRUMENTATION↗

Efficient Algorithm for Locating and Sizing Series Compensation Devices in Large Transmission Grids: Model Implementation (PART 1)

We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.

25 ENERGY STORAGE↗

Consensus Guidelines and Contouring Atlas for Pelvic Node Delineation in Prostate and Pelvic Node Intensity Modulated Radiation Therapy

Purpose: The purpose of this study was to establish reproducible guidelines for delineating the clinical target volume (CTV) of the pelvic lymph nodes (LN) by combining the freehand Royal Marsden Hospital (RMH) and Radiation Therapy Oncology Group (RTOG) vascular expansion techniques. Methods and Materials: Seven patients with prostate cancer underwent standard planning computed tomography scanning. Four different CTVs (RMH, RTOG, modified RTOG, and Prostate and pelvIs Versus prOsTate Alone treatment for Locally advanced prostate cancer [PIVOTAL] trial) were created for each patient, and 6 different bowel expansion margins (BEM) were created to assess bowel avoidance by the CTV. The resulting CTVs were compared visually and by using Jaccard conformity indices. The volume of overlap between bowel and planning target volume (PTV) was measured to aid selection of an appropriate BEM to enable maximal LN yet minimal normal tissue coverage. Results: In total, 84 nodal contours were evaluated. LN coverage was similar in all groups, with all of the vascular-expansion techniques (RTOG, modified RTOG, and PIVOTAL), resulting in larger CTVs than that of the RMH technique (mean volumes: 287.3 cm{sup 3}, 326.7 cm{sup 3}, 310.3 cm{sup 3}, and 256.7 cm{sup 3}, respectively). Mean volumes of bowel within the modified RTOG PTV were 19.5 cm{sup 3} (with 0 mm BEM), 17.4 cm{sup 3} (1-mm BEM), 10.8 cm{sup 3} (2-mm BEM), 6.9 cm{sup 3} (3-mm BEM), 5.0 cm{sup 3} (4-mm BEM), and 1.4 cm{sup 3} (5-mm BEM) in comparison with an overlap of 9.2 cm{sup 3} seen using the RMH technique. Evaluation of conformity between LN-CTVs from each technique revealed similar volumes and coverage. Conclusions: Vascular expansion techniques result in larger LN-CTVs than the freehand RMH technique. Because the RMH technique is supported by phase 1 and 2 trial safety data, we proposed modifications to the RTOG technique, including the addition of a 3-mm BEM, which resulted in LN-CTV coverage similar to that of the RMH technique, with reduction in bowel and planning target volume overlap. On the basis of these findings, recommended guidelines including a detailed pelvic LN contouring atlas have been produced and implemented in the PIVOTAL trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Recombinant Human Endostatin on Radiosensitivity in Patients With Non-Small-Cell Lung Cancer

Purpose: To observe the effects of recombinant human endostatin (RHES) on the radiosensitivity of non-small cell lung cancer (NSCLC). Methods and Materials: First, 10 hypoxia-positive cases of pathology-diagnosed NSCLC selected from 15 patients were used to determine the normalization window, a period during which RHES improves NSCLC hypoxia. Second, 50 hypoxia-positive cases of pathology-diagnosed NSCLC (Stages I-III) were randomly divided into a RHES plus radiotherapy group (25 cases) and a radiotherapy-alone group (25 cases). Intensity = modulated radiotherapy with a total dose of 60 Gy in 30 fractions for 6 weeks was adopted in the two groups. The target area included primary foci and metastatic lymph nodes. In the RHES plus radiotherapy group, RHES (15 mg/day) was intravenously given during the normalization window. Results: After RHES administration, the tumor-to=normal tissue radioactivity ratio and capillary permeability surface were first decreased and then increased, with their lowest points on the fifth day compared with the first day (all p < 0.01). Blood flow was first increased and then decreased, with the highest point on the fifth day, compared with the first and tenth day (all p < 0.01). In the RHES plus radiotherapy group and the radiotherapy-alone group, the total effective rates (complete response plus partial response) were 80% and 44% (p = 0.009), respectively. The median survival times were 21.1 {+-} 0.97 months and 16.5 {+-} 0.95 months (p = 0.004), respectively. The 1-year and 2-year local control rates were 78.9 {+-} 8.4% and 68.1 {+-} 7.8% (p = 0.027) and 63.6 {+-} 7.2% and 43.4 {+-} 5.7% (p = 0.022), respectively. The 1-year and 2-year overall survival rates were 83.3 {+-} 7.2% and 76.6 {+-} 9.3% (p = 0.247) and 46.3 {+-} 2.4% and 37.6 {+-} 9.1% (p = 0.218), respectively. Conclusion: The RHES normalization window is within about 1 week after administration. RHES combined with radiotherapy within the normalization window has better short-term therapeutic effects and local control rates and no severe adverse reactions in the treatment of NSCLC, but it failed to significantly improve the 1-year and 3-year overall survival rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individual control and readout of qubits in a sub-diffraction volume

Abstract Medium-scale ensembles of coupled qubits offer a platform for near-term quantum technologies as well as studies of many-body physics. A central challenge for coherent control of such systems is the ability to measure individual quantum states without disturbing nearby qubits. Here, we demonstrate the measurement of individual qubit states in a sub-diffraction cluster by selectively exciting spectrally distinguishable nitrogen vacancy centers. We perform super-resolution localization of single centers with nanometer spatial resolution, as well as individual control and readout of spin populations. These measurements indicate a readout-induced crosstalk on non-addressed qubits below 4 × 10 −2 . This approach opens the door to high-speed control and measurement of qubit registers in mesoscopic spin clusters, with applications ranging from entanglement-enhanced sensors to error-corrected qubit registers to multiplexed quantum repeater nodes.

Bersin, Eric (ORCID:0000000306435534)↗

Design and evaluation of a low-cost sensor node for near-background methane measurement

Abstract. We developed a low-cost methane sensing node incorporating two metal oxide (MOx) sensors (Figaro Engineering TGS2611-E00 and TGS2600), humidity and temperature sensing, data storage, and telemetry. We deployed the prototype sensor alongside a reference methane analyzer at two sites: one outdoors and one indoors. We collected data at each site for several months across a range of environmental conditions (particularly temperature and humidity) and methane levels. We explored calibration models to investigate the performance of our system and its suitability for methane background monitoring and enhancement detection, first selecting a linear regression to fit a sensor baseline response and then fitting methane response by the sensor deviation from baseline. We achieved moderate accuracy in a 2 to 10 ppm methane range compared to data from the reference analyzer (RMSE < 0.6 ppm), but we found that the sensor response varied over time, possibly as a result of changes in non-targeted gas concentrations. We suggest that this cross sensitivity may be responsible for mixed results in previous studies. We discuss the implications of our results for the use of these and similar inexpensive MOx sensors for methane monitoring in the 2 to 10 ppm range.

Furuta, Daniel↗

Scalable Approaches to Selecting Key Entities in Large Networked Infrastructure Systems

This work aims at bringing advances in discrete optimization algorithms to solving practical engineering problems at scale. Often times, in many engineering design problems, there is a need to select a small set of influential or representative elements from a large ground set of entities in an optimal fashion. Submodular optimization provides for a formal way to solve such problems. Common examples with infrastructure systems involve sensor placement and identification of key entities with certain objectives. However, scaling these approaches to large infrastructure systems can be challenging because of the high computational complexity of the overall framework that include the optimization algorithms as well as high-complexity compute-oracles that provide the necessary objective function values. In this work, we explore a well-studied and widely-applicable paradigm, namely leader-selection in a multi-agent networked setting in the context of scalable methodologies. We demonstrate novel frameworks that utilize variations of accelerated submodular optimization algorithms along with linear-algebraic methods that can help accelerate the oracle computations. We further explore this combination in conjunction with graph partitioning paradigms to take advantage of the accelerated algorithms in a distributed setting. Finally we demonstrate the key findings on a practical problem in an operational setting. For this, we leverage an example road network with approximately 18k nodes and 27k edges in a traffic control application, where we seek a limited number of k=200 key intersections. This problem can be solved in a serial setting in just under 5 hours providing more than 2 orders of magnitude speed-up over methods that do not consider acceleration techniques.

Visweswara Sathanur, Arun↗

A Comparative Study of Layer Heating and Continuous Heating Methods on Prediction Accuracy of Residual Stresses in Selective Laser Melted Tube Samples

Thermal distortion and residual stresses are two important factors that affect the quality and reliability of steel parts manufactured by laser powder bed fusion (LPBF) processes. A cost-effective model for evaluation of those heat effects is needed to refine the manufacturing process and provides insights into the product design and heat treatment. In this study, the layer heating method and sophisticated track-layer scanning method were applied to simulate the thermo-mechanical response of IN625 tube parts built by LPBF. Based on the similarity of temperature field in each layer deposit, a swept mesh was constructed to perform the thermal analysis for top layer, with the rest of layers referring to the temperature by node number offsetting. A novel explicit finite element analysis code accelerated by graphics processing unit was used for the massive-element numerical analysis. The computational accuracy and efficiency of the layer heating and track-layer scanning methods were compared in detail. It is shown that layer heating method can efficiently capture the pattern of stress distribution with reasonable accuracy in stress magnitude. The grouped track-layer scanning method can predict the residual stress and strain more accurately at a higher cost (5 ~ 10×). The elastic strain distribution was compared with the measurement by X-ray diffraction, confirming the accuracy of residual stress prediction.

36 MATERIALS SCIENCE↗

Increased Detection of Lymphatic Vessel Invasion by D2-40 (Podoplanin) in Early Breast Cancer: Possible Influence on Patient Selection for Accelerated Partial Breast Irradiation

Purpose: Several international trials are currently investigating accelerated partial breast irradiation (APBI) for patients with early-stage breast cancer. According to existing guidelines, patients with lymphatic vessel invasion (LVI) do not qualify for APBI. D2-40 (podoplanin) significantly increases the frequency of LVI detection compared with conventional hematoxylin and eosin (HE) staining in early-stage breast cancer. Our purpose was to retrospectively assess the hypothetical change in management from APBI to whole breast radiotherapy with the application of D2-40. Patients and Methods: Immunostaining with D2-40 was performed on 254 invasive breast tumors of 247 patients. The following criteria were used to determine the eligibility for APBI: invasive ductal adenocarcinoma of {<=}3 cm, negative axillary node status (N0), and unifocal disease. Of the 247 patients, 74 with available information concerning LVI, as detected by D2-40 immunostaining and routine HE staining, formed our study population. Results: Using D2-40, our results demonstrated a significantly greater detection rate (p = .031) of LVI compared with routine HE staining. LVI was correctly identified by D2-40 (D2-40-positive LVI) in 10 (13.5%) of 74 tumors. On routine HE staining, 4 tumors (5.4%) were classified as HE-positive LVI. Doublestaining of these specimens with D2-40 unmasked false-positive LVI status in 2 (50%) of the 4 tumors. According to the current recommendations for APBI, immunostaining with D2-40 would have changed the clinical management from APBI to whole breast radiotherapy in 8 (10.8%) of 74 patients and from whole breast radiotherapy to APBI in 2 patients (2.7%). Conclusion: These data support the implementation of D2-40 immunostaining in the routine workup to determine a patient's eligibility for APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗