Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

An improved physics-based approach for unfolding megavoltage bremsstrahlung spectra using transmission analysis

Purpose: To develop a physics-based approach to improve the accuracy and robustness of the ill-conditioned problem of unfolding megavoltage bremsstrahlung spectra from transmission data. Methods: Spectra are specified using a rigorously-benchmarked functional form. Since ion chambers are the typical detector used in transmission measurements, the energy response of a Farmer chamber is calculated using the EGSnrc Monte Carlo code, and the effect of approximating the energy response on the accuracy of the unfolded spectra is studied. A proposal is introduced to enhance spectral sensitivity by combining transmission data measured with multiple detectors of different energy response and by combining data from multiple attenuating materials. Monte Carlo methods are developed to correct for nonideal exponential attenuation (e.g., scatter effects and secondary attenuation). The performance of the proposed methods is evaluated for a diverse set of validated clinical spectra (3.5-25 MV) using analytical transmission data with simulated experimental noise. Results: The approximations commonly used in previous studies for the ion-chamber energy response lead to significant errors in the unfolded spectra. Of the configurations studied, the one with best spectral sensitivity is to measure four full transmission curves using separate low-Z and high-Z attenuators in conjunction with two detectors of different energy response (the authors propose a Farmer-type ion chamber, once with a low-Z, and once with a high-Z buildup cap material), then to feed the data simultaneously to the unfolding algorithm. Deviations from ideal exponential attenuation are as much as 1.5% for the smallest transmission signals, and the proposed methods properly correct for those deviations. The transmission data with enhanced spectral sensitivity, combined with the accurate and flexible spectral functional form, lead to robust unfolding without requiring a priori knowledge of the spectrum. Compared with the commonly-used methods, the accuracy is improved for the unfolded spectra and for the unfolded mean incident electron kinetic energy by at least factors of three and four, respectively. With simulated experimental noise and a lowest transmission of 1%, the unfolded energy fluence spectra agree with the original spectra with a normalized root-mean-square deviation, %{Delta}({psi}), of 2.3%. The unfolded mean incident electron kinetic energies agree, on average, with the original values within 1.4%. A lowest transmission of only 10% still allows unfolding with %{Delta}({psi}) of 3.3%. Conclusions: In the presence of realistic experimental noise, the proposed approach significantly improves the accuracy and robustness of the spectral unfolding problem for all therapy and MV imaging beams of clinical interest.

61 RADIATION PROTECTION AND DOSIMETRY↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Optical Properties of Zitex in the Infrared Submillimeter

The results of measurements of the refractive index and power attenuation coefficient of Zitex at 290K, 77K, and 4K in the spectral region from 1 to 1000 microns are presented. Zitex is a porous Teflon sheet with a filling factor of approx. 50%, and is manufactured in several varieties as a filter paper. Zitex is found to be an effective IR block, with thin (200 microns) sheets transmitting less than 1% in the 1 - 50 microns range while attenuating less than or approx. 10% at wavelengths longer than 200 microns. Some variation in the cutoff wavelength is seen, tending to be a shorter wavelength cutoff for a smaller pore size. Additionally, the thermal conductivity of Zitex at cryogenic temperatures has been measured, and is found to be roughly one-half that of bulk Teflon. Finally, its dielectric constant has been measured in the submillimeter as n = 1.20, resulting in extremely low dielectric reflection losses. As a result, Zitex is particularly useful as an IR blocking filter in low-noise heterodyne receivers; in the millimeter-wave range (lambda greater than approx. 850 microns or nu less than or = 350 GHz) the attenuation of alpha less than or = 0.01/cm for a 3.5 mm thickness filter of Zitex G125 would raise receiver noise temperatures by less than 1K.

Benford, Dominic J.↗

The minimum crystal size needed for a complete diffraction data set

A formula for absolute scattering power is derived to include spot fading arising from radiation damage and the crystal volume needed to collect diffraction data to a given resolution is calculated. In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data-driven Minimum Entropy Control for Stochastic Nonlinear Systems using the Cumulant-Generating Function

Here, we present a novel minimum entropy control algorithm for a class of stochastic nonlinear systems subjected to non-Gaussian noises. The entropy control can be considered as an optimization problem for the system randomness attenuation, but the mean value has to be considered separately. To overcome this disadvantage, a new representation of the system stochastic properties was given using the cumulant-generating function based on the moment-generating function, in which the mean value and the entropy was reflected by the shape of the cumulant-generating function. Based on the samples of the system output and control input, a time-variant linear model was identified, and the minimum entropy optimization was transformed to system stabilization. Then, an optimal control strategy was developed to achieve the randomness attenuation, and the boundedness of the controlled system output was analyzed. The effectiveness of the presented control algorithm was demonstrated by a numerical example. In this paper, a data-driven minimum entropy design is presented without pre-knowledge of the system model; entropy optimization is achieved by the system stabilization approach in which the stochastic distribution control and minimum entropy are unified using the same identified structure; and a potential framework is obtained since all the existing system stabilization methods can be adopted to achieve the minimum entropy objective.

42 ENGINEERING↗

Prediction techniques

Prediction methods and related propagation results for the evaluation of Earth-space communication paths operating above 10 GHz are presented. Gaseous attenuation, rain, cloud, fog, sand, and dust attenuation, path diversity, signal fluctuations and low angle fading, depolarization effects, bandwidth coherence, and sky noise are considered.

Source record↗

A Maximum Likelihood Approach to Determine Sensor Radiometric Response Coefficients for NPP VIIRS Reflective Solar Bands

Optical sensors aboard Earth orbiting satellites such as the next generation Visible/Infrared Imager/Radiometer Suite (VIIRS) assume that the sensors radiometric response in the Reflective Solar Bands (RSB) is described by a quadratic polynomial, in relating the aperture spectral radiance to the sensor Digital Number (DN) readout. For VIIRS Flight Unit 1, the coefficients are to be determined before launch by an attenuation method, although the linear coefficient will be further determined on-orbit through observing the Solar Diffuser. In determining the quadratic polynomial coefficients by the attenuation method, a Maximum Likelihood approach is applied in carrying out the least-squares procedure. Crucial to the Maximum Likelihood least-squares procedure is the computation of the weight. The weight not only has a contribution from the noise of the sensor s digital count, with an important contribution from digitization error, but also is affected heavily by the mathematical expression used to predict the value of the dependent variable, because both the independent and the dependent variables contain random noise. In addition, model errors have a major impact on the uncertainties of the coefficients. The Maximum Likelihood approach demonstrates the inadequacy of the attenuation method model with a quadratic polynomial for the retrieved spectral radiance. We show that using the inadequate model dramatically increases the uncertainties of the coefficients. We compute the coefficient values and their uncertainties, considering both measurement and model errors.

Lei, Ning↗

Development of Gallium Nitride Monolithic Microwave Integrated Circuits for Ka-Band Remote Sensing

We have been developing gallium nitride (GaN)monolithic microwave integrated circuits (MMICs) towards thegoal of implementing a single chip transceiver frontend forcloud radar arrays at Ka-band. We present our first iterationdesign, fabrication and test cycle implementation of GaN poweramplifiers (PAs), low noise amplifiers (LNAs), driver amplifier,single-pole- double and triple throw switches, and voltagecontrolled attenuator. These components are necessary forimplementing a transceiver unit cell concept with digitalcalibration capabilities to enable scalable array sizes for radarand radiometry.

Cao, Yu↗

High-Power Radar Sounders for the Investigation of Jupiter Icy Moons

The high power and high data rate capability made available by a Prometheus class spacecraft could significantly enhance our ability to probe the subsurface of the planets/moons and asteroid/comets. The main technology development driver for our radar is the proposed Jupiter Icy Moon Orbiter (or JIMO) mission due to its harsh radiation environment. We plan to develop a dual-band radar at 5 and 50 MHz in response to the two major science requirements identified by the JIMO Science Definition Team: studying the near subsurface (less than 2 km) at high resolution and detection of the ice/ocean interface for Europa (depth up to 30 km). The 50-MHz band is necessary to provide high spatial resolution (footprint and depth) as required by the JIMO mission science requirements as currently defined. Our preliminary assessment indicates that the 50-MHz system is not required to be as high-power as the 5-MHz system since it will be more limited by the surface clutter than the Jupiter or galactic background noise. The low frequency band (e.g. 5 MHz), which is the focus of this effort, would be necessary to mitigate the performance risks posed by the unknown subsurface structure both in terms of unknown attenuation due to volumetric scattering and also the detection of the interface through the attenuative transition region at the ice/ocean interface. Additionally, the 5-MHz band is less affected by the surface roughness that can cause loss of coherence and clutter noise. However, since the Signal-to-Noise-Ratio (SNR) of the 5-MHz radar band is reduced due to Jupiter noise when operating in the Jupiter side of the moon, it is necessary to increase the radiated power. Our challenge is to design a high-power HF radar that can hnction in Jupiter's high radiation environment, yet be able to fit into spacecraft resource constraints such as mass and thermal limits. Our effort to develop the JIMO radar sounder will rely on our team's experience with planetary radar sounder design gained during our participation in the MARSIS radar sounder implementation.

Safaeinili, A.↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

LOW SCATTER, HIGH KILOVOLT, A-SI FLAT PANEL X-RAY DETECTOR

We have been using amorphous silicon (a-Si) flat panel detectors in high energy (>400 kV) cone beam computed tomography (CT) applications for a number of years. We have found that these detectors have a significant amount of internal scatter that degrades the accuracy of attenuation images. The scatter errors cause cupping and streaking artifacts that are practically indistinguishable from beam hardening artifacts. Residual artifacts remain after beam hardening correction and over correction increases noise in CT reconstructions. Another important limitation of existing detectors is that they have a high failure rate, especially when operating at megavolt x-ray energies even with a well collimated beam. Due to the limitations of the current detectors, we decided to design a detector specifically for high energies that has significantly reduced scatter. In collaboration with IMTEC, we have built a prototype amorphous silicon flat panel detector that has both improved imaging response and increased lifetime. LANL's contribution is the ''transparent panel concept''(patent pending), in which structures in the x-ray beam path are either eliminated or made as transparent to x-rays as practical (low atomic number and low areal density). This reduces scatter, makes attenuation measurements more accurate, improves the ability to make corrections for beam hardening, and increases signal to noise ratio in DR images and CT reconstructions. IMTEC's contribution is an improved shielding design that will increase the lifetime of the panel. Preliminary results showing the dramatic reduction in self scatter from the panel will be presented as well as the effect of this improvement on CT images.

36 MATERIALS SCIENCE↗

The MOSDEF Survey: Measurements of Balmer decrements and the dust attenuation curve at Redshifts z ∼ 1.4–2.6

We present results on the dust attenuation curve of z ∼ 2 galaxies using early observations from the MOSFIRE Deep Evolution Field survey. Our sample consists of 224 star-forming galaxies with z{sub spec} = 1.36–2.59 and high signal-to-noise ratio measurements of Hα and Hβ obtained with Keck/MOSFIRE. We construct composite spectral energy distributions (SEDs) of galaxies in bins of Balmer decrement to measure the attenuation curve. We find a curve that is similar to the SMC extinction curve at λ ≳ 2500 Å. At shorter wavelengths, the shape is identical to that of the Calzetti et al. relation, but with a lower normalization. Hence, the new attenuation curve results in star formation rates (SFRs) that are ≈20% lower, and stellar masses that are Δlog(M{sup ∗}/M{sub ⊙})≃0.16 dex lower, than those obtained with the Calzetti relation. We find that the difference in the total attenuation of the ionized gas and stellar continuum correlates strongly with SFR, such that for dust-corrected SFRs ≳ 20 M{sub ⊙} yr{sup −1}, assuming a Chabrier initial mass function, the nebular emission lines suffer an increasing degree of obscuration relative to the continuum. A simple model that can account for these trends is one in which the UV through optical stellar continuum is dominated by a population of less-reddened stars, while the nebular line and bolometric luminosities become increasingly dominated by dustier stellar populations for galaxies with large SFRs, as a result of the increased dust enrichment that accompanies such galaxies. Consequently, UV- and SED-based SFRs may underestimate the total SFR at even modest levels of ≈20 M{sub ⊙} yr{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Noise properties of grating-based x-ray phase contrast computed tomography

Purpose: To investigate the properties of tomographic grating-based phase contrast imaging with respect to its noise power spectrum and the energy dependence of the achievable contrast to noise ratio. Methods: Tomographic simulations of an object with 11 cm diameter constituted of materials of biological interest were conducted at different energies ranging from 25 to 85 keV by using a wave propagation approach. Using a Monte Carlo simulation of the x-ray attenuation within the object, it is verified that the simulated measurement deposits the same dose within the object at each energy. Results: The noise in reconstructed phase contrast computed tomography images shows a maximum at low spatial frequencies. The contrast to noise ratio reaches a maximum around 45 keV for the simulated object. The general dependence of the contrast to noise on the energy appears to be independent of the material. Compared with reconstructed absorption contrast images, the reconstructed phase contrast images show sometimes better, sometimes worse, and sometimes similar contrast to noise, depending on the material and the energy. Conclusions: Phase contrast images provide additional information to the conventional absorption contrast images and might thus be useful for medical applications. However, the observed noise power spectrum in reconstructed phase contrast images implies that the usual trade-off between noise and resolution is less efficient for phase contrast imaging compared with absorption contrast imaging. Therefore, high-resolution imaging is a strength of phase contrast imaging, but low-resolution imaging is not. This might hamper the clinical application of the method, in cases where a low spatial resolution is sufficient for diagnosis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accounting for Dose Uncertainty in Dose-Response Curve Estimation Using Hierarchical Bayes Models

As part of their development of the technology for low-boom supersonic flight, the National Aeronautics and Space Administration (NASA) is planning to conduct a set of supersonic aircraft annoyance surveys in select communities in the United States, to measure public perception of the reduced sonic boom. The relationship between a noise exposure level of a supersonic flight event and the probability of an individual being highly annoyed by the event is quantified by a dose-response curve, which is usually based on logistic regression modeling. Unavoidable amounts of estimation error are expected in the upcoming noise measurements, which can bias the results of the logistic regression if ignored. Hence, the development of an estimation approach that accounts for such error when estimating the dose-response curve is imperative. In this paper, an evaluation study is conducted to assess the impact of measurement error on dose-response curve estimation. For this, hierarchical Bayes models using different specifications are fit to data collected by NASA in 2018, as part of a risk-reduction study of supersonic flights affecting Galveston, Texas. It is observed that the estimated dose-response curve appears sensitive to uncertainty in dose measurements, being subject to attenuation bias.

community response↗

Dimensionality and noise in energy selective x-ray imaging

Purpose: To develop and test a method to quantify the effect of dimensionality on the noise in energy selective x-ray imaging.Methods: The Cramèr-Rao lower bound (CRLB), a universal lower limit of the covariance of any unbiased estimator, is used to quantify the noise. It is shown that increasing dimensionality always increases, or at best leaves the same, the variance. An analytic formula for the increase in variance in an energy selective x-ray system is derived. The formula is used to gain insight into the dependence of the increase in variance on the properties of the additional basis functions, the measurement noise covariance, and the source spectrum. The formula is also used with computer simulations to quantify the dependence of the additional variance on these factors. Simulated images of an object with three materials are used to demonstrate the trade-off of increased information with dimensionality and noise. The images are computed from energy selective data with a maximum likelihood estimator.Results: The increase in variance depends most importantly on the dimension and on the properties of the additional basis functions. With the attenuation coefficients of cortical bone, soft tissue, and adipose tissue as the basis functions, the increase in variance of the bone component from two to three dimensions is 1.4 × 10{sup 3}. With the soft tissue component, it is 2.7 × 10{sup 4}. If the attenuation coefficient of a high atomic number contrast agent is used as the third basis function, there is only a slight increase in the variance from two to three basis functions, 1.03 and 7.4 for the bone and soft tissue components, respectively. The changes in spectrum shape with beam hardening also have a substantial effect. They increase the variance by a factor of approximately 200 for the bone component and 220 for the soft tissue component as the soft tissue object thickness increases from 1 to 30 cm. Decreasing the energy resolution of the detectors increases the variance of the bone component markedly with three dimension processing, approximately a factor of 25 as the resolution decreases from 100 to 3 bins. The increase with two dimension processing for adipose tissue is a factor of two and with the contrast agent as the third material for two or three dimensions is also a factor of two for both components. The simulated images show that a maximum likelihood estimator can be used to process energy selective x-ray data to produce images with noise close to the CRLB.Conclusions: The method presented can be used to compute the effects of the object attenuation coefficients and the x-ray system properties on the relationship of dimensionality and noise in energy selective x-ray imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗