Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Model Development and Analysis of a High-Fidelity Neutron Transport Sensor: The Quadrupole Detector Concept for Measurement of the Neutron Flux Gradient

Accurate reconstruction of the neutron flux distribution within a reactor core is essential for safe and efficient reactor operation. Traditional power shape synthesis in Light Water Reactors relies on hundreds of in-core detectors. However, this approach becomes impractical for Advanced Reactors and Microreactors due to limited space and harsh environments. To address this challenge, we propose a data-driven methodology that combines high-fidelity modeling with real-time ex-core sensor measurements, enabling the reconstruction of core power distribution while minimizing the reliance on intrusive in-core instrumentation. This project began in FY24 and achieved two initial milestones: (1) the definition of a three-year development plan for a Digital Twin framework and (2) the development of high-fidelity neutronics models of the Purdue University Reactor One (PUR-1) using both MCNP6 and OpenMC. The PUR-1 reactor, a zero-power facility, was selected due to its suitability for neutronics-focused modeling and the availability of experimental data for validation. Both models were benchmarked using neutron flux measurements obtained from irradiated gold foils, which were strategically placed within the core during a dedicated campaign in July 2024. This report marks the continuation and completion of those foundational tasks. The OpenMC model has been refined (improved geometric accuracy, expanded cross-section libraries, and refined sampling) and validated using additional experimental data. An updated sensor design—based on quadrupole configuration—was designed to measure both ex-core flux and its spatial gradient. These measurements will serve as inputs to a neural network-based reconstruction algorithm. Finally, the methodology was demonstrated on a two-dimensional test case representative of the heterogeneous material composition of the PUR-1 reactor core. A neural network implementation of the Kirchhoff-Helmholtz integral equation was employed to solve the boundary value problem using peripheral sensor measurements. The preliminary results confirm the strong potential of the proposed approach for accurate and minimally invasive neutron flux reconstruction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Relative Contribution to Heavy Metals Production from Binary Neutron Star Mergers and Neutron Star–Black Hole Mergers

The origin of the heavy elements in the universe is not fully determined. Neutron star–black hole (NSBH) and binary neutron star (BNS) mergers may both produce heavy elements via rapid neutron-capture (r-process). We use the recent detection of gravitational waves from NSBHs, improved measurements of the neutron star equation of state (EoS), and the most modern numerical simulations of ejected material from binary collisions to measure the relative contribution of NSBHs and BNSs to the production of heavy elements. As the amount of r-process ejecta depends on the mass and spin distribution of the compact objects, as well as on the EoS of the neutron stars, we consider various models for these quantities, informed by gravitational-wave and pulsar data. We find that in most scenarios, BNSs have produced more r-process elements than NSBHs over the past 2.5 billion years. If black holes have preferentially small spins, BNSs can produce at least twice the amount of r-process elements than NSBHs. If black hole spins are small and there is a dearth of low-mass (<5M ⊙ ) black holes within NSBH binaries, BNSs can account for the near totality of the r-process elements from binaries. For NSBH to produce a large fraction of r-process elements, black holes in NSBHs must have small masses and large aligned spins, which is disfavored by current data.

79 ASTRONOMY AND ASTROPHYSICS↗

Production and Study of Neutron-rich Nuclei Using the LICORNE Directional Neutron Source

We have recently successfully demonstrated a new technique for production and study of many of the most exotic neutron-rich nuclei at moderate spins. LICORNE, a newly developed directional inverse-kinematic fast neutron source at the IPN Orsay, was coupled to the MINIBALL high resolution γ-ray spectrometer to study nuclei the furthest from stability using the 238 U(n,f)reaction. This reaction and 232 Th(n,f)are the most neutron-rich fission production mechanisms achievable and can be used to simultaneously populate hundreds of neutron-rich nuclei up to spins of ≈ 16h. High selectivity in the experiment was achieved via tripleγ-ray coincidences and the use of a 400 ns period pulsed neutron beam,a technique which is unavailable to other population mechanisms such as 235 U(nth,f) and 252 Cf(SF). The pulsing allows time correlations to be exploited to separate delayedγrays from isomeric states in the hundreds of nuclei produced, which are then used to cleanly select a particular nucleus and its exotic binary partners. In the recent experiment, several physics cases are simultaneously addressed such as shape coexistence, the evolution of shell closures far from stability, and the spectroscopy of nuclei in the r-process path near N= 82. Overall, preliminary physics results on anomalies in the 238 U(n,f) fission yields and the structure of the 138 Te and100Sr nuclei will soon be published. A future project,ν-ball, to couple LICORNE with a hybrid escape-suppressed spectrometer to refine further the technique and achieve a large increase in the observational limit is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

Semones, Edward↗

Neutron matter, symmetry energy and neutron stars

Recent progress in quantum Monte Carlo with modern nucleon-nucleon interactions have enabled the successful description of properties of light nuclei and neutron-rich matter. Of particular interest is the nuclear symmetry energy, the energy cost of creating an isospin asymmetry, and its connection to the structure of neutron stars. Combining these advances with recent observations of neutron star masses and radii gives insight into the equation of state of neutron-rich matter near and above the saturation density. In particular, neutron star radius measurements constrain the derivative of the symmetry energy.

Stefano, Gandolfi↗

Advanced Neutron Counting Electronics Designed and Implemented on the JCC-71 Neutron Coincidence Collar to Replace Standard JAB-01 Preamplifier/Amplifier/Discriminator Boards

New in-house neutron counting electronics were designed and built at Oak Ridge National Laboratory to replace the Canberra Industries JAB-01 preamplifier/amplifier/discriminator boards on their JCC-71 Neutron Coincidence Collar model system. The new electronics include a preamplifier and motherboard design, which fit inside the footprint of the existing junction box, as well as an external “ORNL Neutron Collar Processor” board. The goal of the new electronics is to provide the same neutron processing functionalities as the JAB-01 boards and extend the capabilities of the JCC-71 system by placing a preamplifier on each of the 18 3He tubes to facilitate neutron list mode data acquisition. Each 3He tube is then capable of producing an individual signal output to be analyzed using a list mode data acquisition system such as the PTR-32 or N2000. List mode data analysis provides the opportunity to use all 18 signal channels to produce a spatial response matrix to assay fresh nuclear fuel assemblies. This paper describes the development of the new electronics and provides performance comparison measurements between the two electronics board systems using list mode data acquisition.

Moore, Angela↗

Development of Large-Volume-Diamond Anvil Cell for Neutron Diffraction: The Neutron Diamond Anvil Cell Project at ORNL

10 years ago, Dave Mao, director of EFree (energy frontier research in extreme environments), a DOE energy frontier recognized the importance of neutron science for energy research. The subsequent establishment of a neutron group within EFree lead to the establishment of an “Instrument Development Team” for SNAP, the High-Pressure beamline at the Spallation Neutron Source at Oak Ridge National Laboratory in Tennessee. The idea was to develop novel high pressure techniques to expand the pressure range for neutron diffraction. A goal was set to reach half megabar levels (50 GPa), which at the time was considered as extremely challenging. Here we will give a brief overview of the developments during the last decade in this novel area of research. Fortunately, during this period multi carat diamond anvils have become available mainly by the chemical vapor deposition process (CVD), making research in this pressure range and beyond rather routine. This paper shows the latest developments in large anvil designs, compact multiple ton diamond cells and some examples of high-quality neutron diffraction patterns of sample sizes far below conventional levels.

Boehler, Reinhard↗

Microstructure and water absorption of ancient concrete from Pompeii: An integrated synchrotron microtomography and neutron radiography characterization

There is renewed interest in using advanced techniques to characterize ancient Roman concrete due to its exceptional durability and low-carbon footprint. In the present work, samples were drilled from the “Hospitium” in Pompeii and were analyzed by synchrotron microtomography (μCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were quantified by neutron radiography. The 3D crack propagation, pore size distribution and orientation, tortuosity, and connectivity were analyzed from μCT results using advanced imaging methods. Porosity was also measured by mercury intrusion porosimetry (MIP) as a reference. Ductile fracture patterns were observed once cracks were introduced. Compared to Portland cement mortar/concrete, the Pompeii samples had relatively high porosity, low connectivity, and a similar coefficient of capillary penetration. In addition, permeability was predicted from models based on percolation theory and pore structure data to evaluate the fluid transport properties. Understanding the microstructure of ancient Pompeii concrete is important because it could inspire the development of modern concrete with high durability.

36 MATERIALS SCIENCE↗

Hierarchical optimization for neutron scattering problems

We present a scalable optimization method for neutron scattering problems that determines confidence regions of simulation parameters in lattice dynamics models used to fit neutron scattering data for crystalline solids. The method uses physics-based hierarchical dimension reduction in both the computational simulation domain and the parameter space. We demonstrate for silicon that after a few iterations the method converges to parameters values (interatomic force-constants) computed with density functional theory simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quark-Hadron Duality in Neutron Spin-Structure and g{sub 2} moments at intermediate Q{sup 2}

Jefferson Lab experiment E01-012 measured the {sup 3}He spin-structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0<Q{sup 2}<4.0 (GeV/c){sup 2}. Our data, when compared with existing deep inelastic scattering data, were used to test quark-hadron duality in g{sub 1} and A{sub 1} for {sup 3}He and the neutron. In addition, preliminary results on the {sup 3}He spin-structure function g{sub 2}, on the Burkhardt-Cottingham sum rule and on higher twist effects through the x{sup 2}-weighted moment d{sub 2} of the neutron were presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Neutron and {sup 3}He Spin Structure Functions at Low Q{sup 2}

Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility in Hall A to provide a precise measurement of the moments of the neutron and {sup 3}He spin structure functions. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized {sup 3}He target. The extended Gerasimov-Drell-Hearn integral and other moments of the neutron and {sup 3}He spin structure functions were extracted at very low momentum transfers (0.02<Q{sup 2}<0.3 [GeV/c]{sup 2}). These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the moments of the spin structure functions are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge-Injection-Device Performance in the High-Energy-Neutron Environment of Laser-Fusion Experiments

Charge-injection devices (CIDs) are being used to image x rays in laser-fusion experiments on the University of Rochester’s OMEGA Laser System. The CID cameras are routinely used up to the maximum neutron yields generated (~10^14 DT). The detectors are deployed in x-ray pinhole cameras and Kirkpatrick–Baez microscopes. The neutron fluences ranged from ~10^7 to ~10^9 neutrons/cm^2 and useful x-ray images were obtained even at the highest fluences. It is intended to use CID cameras at the National Ignition Facility (NIF) as a supporting means of recording x-ray images. The results of this work predict that x-ray images should be obtainable on the NIF at yields up to ~10^15, depending on distance and shielding.

Marshall, F J↗

Response to 'Comment on 'Elastic incoherent neutron scattering operating by varying instrumental energy resolution: Principle, simulations, and experiments of the resolution elastic neutron scattering (RENS)'' [Rev. Sci. Instrum. 83, 107101 (2012)]

Recently [S. Magazu et al., Rev. Sci. Instrum. 82, 105115 (2011)] we have proposed a new method for characterizing, by neutron scattering, the dynamical properties of complex material systems, such as, the ones of interest in the biophysical field. This approach called Resolution Elastic Neutron Scattering, in short RENS, is based on the detection of the elastically scattered neutron intensity as a function of the instrumental energy resolution. By experimental, theoretical, and numerical findings, we have pointed out that an inflection point occurs in the elastic intensity when the system relaxation time approaches the instrumental energy resolution time. This approach, differently from quasi-elastic neutron scattering (QENS), gives the chance to evaluate the system relaxation times without using pre-defined models that can be wrong and/or misleading. Here, we reply to a Comment on the above-mentioned main paper in which Wuttke proposes a different approach to evaluate the above-mentioned inflection point; on this regard, it should be noticed that the existence of the inflection point, which is the main topic of our work, is not questioned and that the approach proposed by Wuttke in the Comment, although valid for a class of dynamical processes, is not applicable when different and distinct processes occur simultaneously at different time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field ionization characteristics of an ion source array for neutron generators

A new deuterium ion source is being developed to improve the performance of existing compact neutron generators. The ion source is a microfabricated array of metal tips with an integrated gate (i.e., grid) and produces deuterium ions by field ionizing (or field desorbing) a supply of deuterium gas. Deuterium field ion currents from arrays at source temperatures of 77 K and 293 K are studied. Ion currents from single etched-wire tips operating under the same conditions are used to help understand array results. I-F characteristics of the arrays were found to follow trends similar to those of the better understood single etched-wire tip results; however, the fields achieved by the arrays are limited by electrical breakdown of the structure. Neutron production by field ionization at 293 K was demonstrated for the first time from microfabricated array structures with integrated gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of four direct geometry time-of-flight spectrometers at the Spallation Neutron Source

The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.

07 ISOTOPE AND RADIATION SOURCES↗

Deuterium density profile determination at JET using a neutron camera and a neutron spectrometer

In this work we estimate the fuel ion density profile in deuterium plasmas at JET, using the JET neutron camera, the neutron time-of-flight spectrometer TOFOR, and fusion reactivities modeled by the transport code TRANSP. The framework has been tested using synthetic data, which showed that the density profile could be reconstructed with an average accuracy of the order of 10 %. The method has also been applied to neutron measurements from a neutral beam heated JET discharge, which gave n{sub d}/n{sub e} ≈ 0.6 ± 0.3 in the plasma core and n{sub d}/n{sub e} ≈ 0.4 ± 0.3 towards the edge. Correction factors for detector efficiencies, neutron attenuation, and back-scattering are not yet included in the analysis; future work will aim at refining the estimated density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗