Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings—Part 2

This issue of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) is fully dedicated to peer-reviewed papers specific to technologies and applications of Grid-interactive Efficient Buildings (GEBs). As defined by a series of publications by the U.S. Department of Energy (DOE) and outlined in Part 1 of the editorial of JESBC August 2020 issue, GEBs are efficient, connected, smart, and flexible buildings. This GEB special issue covers some technologies and applications for grid-connected buildings and communities. Some of technologies included in the special issue are dynamic insulation systems for building envelopes, building integrated fuel cells, and rooftop PV systems. Furthermore, the issue outlines the designs and cost-benefits of net-zero energy (NZE) buildings and carbon neutral communities in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes

This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes

This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Strong Local Evaporative Cooling Over Land Due to Atmospheric Aerosols

Abstract Aerosols can enhance terrestrial productivity through increased absorption of solar radiation by the shaded portion of the plant canopy—the diffuse radiation fertilization effect. Although this process can, in principle, alter surface evaporation due to the coupling between plant water loss and carbon uptake, with the potential to change the surface temperature, aerosol‐climate interactions have been traditionally viewed in light of the radiative effects within the atmosphere. Here, we develop a modeling framework that combines global atmosphere and land model simulations with a conceptual diagnostic tool to investigate these interactions from a surface energy budget perspective. Aerosols increase the terrestrial evaporative fraction, or the portion of net incoming energy consumed by evaporation, by over 4% globally and as much as ∼40% regionally. The main mechanism for this is the increase in energy allocation from sensible to latent heat due to global dimming (reduction in global shortwave radiation) and slightly augmented by diffuse radiation fertilization. In regions with moderately dense vegetation (leaf area index >2), the local surface cooling response to aerosols is dominated by this evaporative pathway, not the reduction in incident radiation. Diffuse radiation fertilization alone has a stronger impact on gross primary productivity (+2.18 Pg C y −1 or +1.8%) than on land evaporation (+0.18 W m −2 or +0.48%) and surface temperature (−0.01 K). Our results suggest that it is important for land surface models to distinguish between quantity (change in total magnitude) and quality (change in diffuse fraction) of radiative forcing for properly simulating surface climate.

Chakraborty, TC↗

Investigation of the Residual in Column-Integrated Atmospheric Energy Balance Using Cloud Objects

Observationally based atmospheric energy balance is analyzed using Clouds and the Earth’s Radiant Energy System (CERES)-derived TOA and surface irradiance, Global Precipitation Climatology Project (GPCP)-derived precipitation, dry static and kinetic energy tendency and divergence estimated from ERA-Interim, and surface sensible heat flux from SeaFlux. The residual tends to be negative over the tropics and positive over midlatitudes. A negative residual implies that the precipitation rate is too small, divergence is too large, or radiative cooling is too large. The residual of atmospheric energy is spatially and temporally correlated with cloud objects to identify cloud types associated with the residual. Spatially, shallow cumulus, cirrostratus, and deep convective cloud-object occurrence are positively correlated with the absolute value of the residual. The temporal correlation coefficient between the number of deep convective cloud objects and individual energy components, net atmospheric irradiance, precipitation rate, and the sum of dry static and kinetic energy divergence and their tendency over the western Pacific are 0.84, 0.95, and 0.93, respectively. However, when all energy components are added, the atmospheric energy residual over the tropical Pacific is temporally correlated well with the number of shallow cumulus cloud objects over tropical Pacific. Because shallow cumulus alters not enough atmospheric energy compared to the residual, this suggests the following: 1) if retrieval errors associated with deep convective clouds are causing the column-integrated atmospheric energy residual, the errors vary among individual deep convective clouds, and 2) it is possible that the residual is associated with processes in which shallow cumulus clouds affect deep convective clouds and hence atmospheric energy budget over the tropical western Pacific.

54 ENVIRONMENTAL SCIENCES↗

Using an Energy Performance Based Design-Build Process to Procure a Large Scale Low-Energy Building: Preprint

This paper will review a procurement, acquisition, and contract process of a large-scale replicable net zero energy (ZEB) office building. The owners developed and implemented an energy performance based design-build process to procure a 220,000 ft2 office building with contractual requirements to meet demand side energy and LEED goals. We will outline the key procurement steps needed to ensureachievement of our energy efficiency and ZEB goals. The development of a clear and comprehensive Request for Proposals (RFP) that includes specific and measurable energy use intensity goals is critical to ensure energy goals are met in a cost effective manner. The RFP includes a contractual requirement to meet an absolute demand side energy use requirement of 25 kBtu/ft2, with specificcalculation methods on what loads are included, how to normalize the energy goal based on increased space efficiency and data center allocation, specific plug loads and schedules, and calculation details on how to account for energy used from the campus hot and chilled water supply. Additional advantages of integrating energy requirements into this procurement process include leveraging thevoluntary incentive program, which is a financial incentive based on how well the owner feels the design-build team is meeting the RFP goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Nuclear Energy to Support a Net-Zero Future

Seminar for the KEPCO International Nuclear Graduate School (KINGS) in South Korea. The presentation will cover a brief introduction to INL, opportunities for advanced nuclear, and integrated energy systems.

08 HYDROGEN↗

Assessment of Energy Impact of Window Technologies for Commercial Buildings

Windows play a significant role in commercial buildings targeting the goal of net zero energy. This report summarizes research methodology and findings in evaluating the energy impact of windows technologies for commercial buildings. The large office prototypical building, chosen from the DOE commercial building benchmarks, was used as the baseline model which met the prescriptive requirements of ASHRAE Standard 90.1-2004. The building simulations were performed with EnergyPlus and TMY3 weather data for five typical US climates to calculate the energy savings potentials of six windows technologies when compared with the ASHRAE 90.1-2004 baseline windows. The six windows cover existing, new, and emerging technologies, including ASHRAE 189.1 baseline windows, triple pane low-e windows, clear and tinted double pane highly insulating low-e windows, electrochromic (EC) windows, and highly insulating EC windows representing the hypothetically feasible optimum windows. The existing stocks based on average commercial windows sales are included in the analysis for benchmarking purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Topological magnetic hysteresis in single crystals of CeAgSb 2 ferromagnet

Closed-topology magnetic domains are usually observed in thin films and in an applied magnetic field. In this work, we report the observation of rectangular cross-section tubular ferromagnetic domains in thick single crystals of CeAgSb 2 in zero applied field. Relatively low exchange energy, small net magnetic moment, and anisotropic in-plane crystal electric fields lower the domain wall energy and allow for the formation of the closed-topology patterns. The tubular domain structure irreversibly transforms into a dendritic pattern upon cycling the magnetic field. This transition between closed and open topologies results in a ‘topological magnetic hysteresis’— the actual hysteresis in magnetization, not due to the imperfections and pinning, but due to the difference in the pattern morphology. Similar physics was suggested before in pure type-I superconductors and is believed to be a generic feature of other nonlinear single (present case), or two-phase (type-I superconductor) systems where the effects similar to demagnetization (shape-dependent macroscopic variation of properties) lead to pattern formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Making Progress toward Net Zero Sites in the Army Reserve through Analysis of Multiple Scenarios

The U.S. Army Reserve (USAR) prioritized achieving net zero as part of its Sustainability Program in 2013, and developed a pilot that investigated net zero energy, water, and waste at 10 sites. Pilot sites were selected based on mission requirements for energy and water resilience and the likelihood of achieving the technical and economic thresholds for net zero. USAR owns and operates hundreds of sites that typically consist of between 2 and 10 buildings. The pilot sites were intentionally dispersed across the U.S. and its territories to provide a range of geographic characteristics where the net zero potential could be analyzed and solutions could be developed. For the Army, changes to operations must support the mission and enhance readiness, which includes increasing efficiency and resiliency. To facilitate alignment of project prioritization with different goals and site-specific needs, a net zero roadmap outlined three scenarios for project implementation: (1) cost-effective measures, (2) net zero measures, and (3) recommended measures. Each scenario included the same measures for some sites, while others had three different outcomes. USAR has used these roadmaps to plan and execute projects and move toward net zero at multiple sites since 2014, with the primary focus on the cost-effective and recommended scenarios. As conditions and costs change, additional measures required to achieve net zero are considered. This paper describes the methodology deployed for analyzing net zero for the USAR and discusses the benefits of working toward net zero under three distinct scenarios.

Net Zero↗

Why is My Zero Energy Home Not a Zero Carbon Home?

For years, carbon calculations were done very simply. The method of calculation was to take annual totals of energy consumption and multiply by an average emission factor, either for the grid serving a project or for a larger region (e.g. an EPA eGRID sub region). The level of accuracy of this approximation was reasonably good, although the issue of accuracy was not, to our knowledge, tested. And the data required were minimal – just a year’s worth of bills for each fuel and one lookup factor. But this method assures that a net zero energy home is automatically a net zero carbon home because zero times any possible emission factor is still zero. Starting in the early 2010s, things changed – grids were starting to rely more and more heavily on renewables, and the difference was showing up on aggregate load curves. This was perhaps noticed first in California, where aggressive renewable policies led to significant renewable power generation large enough to affect the overall shape of the diurnal load curve for the Independent Systems Operator.

14 SOLAR ENERGY↗

Vehicle to Micro-Grid: Leveraging Existing Assets for Reliable Energy Management (Poster)

Fort Carson, a United States Army installation located south of Colorado Springs, Colorado, is seeking to be a net-zero energy facility. As part of this initiative, the base will be constructing a micro-grid that ties to various forms of renewable energy. To reduce petroleum consumption, Fort Carson is considering grid-connected vehicles (GCVs) such as pure electric trucks to replace some of itson-base truck fleet. As the availability and affordability of distributed renewable energy generation options increase, so will the GCV options (currently, three all-electric trucks are available on the GSA schedule). The presence of GCVs on-base opens up the possibility to utilize these vehicles to provide stability to the base micro-grid. This poster summarizes work to estimate the potentialimpacts of three electric vehicle grid interactions between the electric truck fleet and the Fort Carson micro-grid: 1) full-power charging without management, 2) full-power charging capability controlled by the local grid authority, and 3) full-power charge and discharge capability controlled by the local grid authority. We found that even at relatively small adoption rates, the control ofelectric vehicle charging at Fort Carson will aid in regulation of variable renewable generation loads and help stabilize the micro-grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aspinall Courthouse: GSA's Historic Preservation and Net-Zero Renovation Case Study

The federal government is mandated with improving efficiency of buildings, incorporating renewable energy, and achieving net-zero energy operations where possible. These challenges led GSA to consider aligning historic preservation renovations with net-zero energy goals. The Wayne N. Aspinall Federal Building and U.S. Courthouse (Aspinall Courthouse), in Grand Junction, Colorado, is an example of a renovation project that aimed to accomplish both historic preservation and net-zero energy goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scale interactions and anisotropy in Rayleigh–Taylor turbulence

We study energy scale transfer in Rayleigh–Taylor (RT) flows by coarse graining in physical space without Fourier transforms, allowing scale analysis along the vertical direction. Two processes are responsible for kinetic energy flux across scales: baropycnal work Λ, due to large-scale pressure gradients acting on small scales of density and velocity; and deformation work Π, due to multiscale velocity. Our coarse-graining analysis shows how these fluxes exhibit self-similar evolution that is quadratic-in-time, similar to the RT mixing layer. We find that Λ is a conduit for potential energy, transferring energy non-locally from the largest scales to smaller scales in the inertial range where Π takes over. In three dimensions, Π continues a persistent cascade to smaller scales, whereas in two dimensions Π rechannels the energy back to larger scales despite the lack of vorticity conservation in two-dimensional (2-D) variable density flows. This gives rise to a positive feedback loop in 2-D RT (absent in three dimensions) in which mixing layer growth and the associated potential energy release are enhanced relative to 3-D RT, explaining the oft-observed larger α values in 2-D simulations. Despite higher bulk kinetic energy levels in two dimensions, small inertial scales are weaker than in three dimensions. Moreover, the net upscale cascade in two dimensions tends to isotropize the large-scale flow, in stark contrast to three dimensions. Furthermore, our findings indicate the absence of net upscale energy transfer in three-dimensional RT as is often claimed; growth of large-scale bubbles and spikes is not due to ‘mergers’ but solely due to baropycnal work Λ.