Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NATIONAL SCIENCE FOUNDATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Solar system exploration

The goal of planetary exploration is to understand the nature and development of the planets, as illustrated by pictures from the first two decades of spacecraft missions and by the imaginations of space artists. Planets, comets, asteroids, and moons are studied to discover the reasons for their similarities and differences and to find clues that contain information about the primordial process of planet origins. The scientific goals established by the National Academy of Sciences as the foundation of NASA's Solar System Exploration Program are covered: to determine the nature of the planetary system, to understand its origin and evolution, the development of life on Earth, and the principles that shape present day Earth.

Chapman, Clark R.↗

SU-G-IeP2-08: Investigation On Signal Detectability in Volumetric Cone Beam CT Images with Anatomical Background

Purpose: To investigate the slice direction dependent detectability in cone beam CT images with anatomical background. Methods: We generated 3D anatomical background images using breast anatomy model. To generate 3D breast anatomy, we filtered 3D Gaussian noise with a square root of 1/f{sup 3}, and then assigned the attenuation coefficient of glandular (0.8cm{sup −1}) and adipose (0.46 cm{sup −1}) tissues based on voxel values. Projections were acquired by forward projection, and quantum noise was added to the projection data. The projection data were reconstructed by FDK algorithm. We compared the detectability of a 3 mm spherical signal in the image reconstructed from four different backprojection Methods: Hanning weighted ramp filter with linear interpolation (RECON1), Hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON3), and ramp filter with Fourier interpolation (RECON4), respectively. We computed task SNR of the spherical signal in transverse and longitudinal planes using channelized Hotelling observer with Laguerre-Gauss channels. Results: Transverse plane has similar task SNR values for different backprojection methods, while longitudinal plane has a maximum task SNR value in RECON1. For all backprojection methods, longitudinal plane has higher task SNR than transverse plane. Conclusion: In this work, we investigated detectability for different slice direction in cone beam CT images with anatomical background. Longitudinal plane has a higher task SNR than transverse plane, and backprojection with hanning weighted ramp filter with linear interpolation method (i.e., RECON1) produced the highest task SNR among four different backprojection methods. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Programs(IITP-2015-R0346-15-1008) supervised by the IITP (Institute for Information & Communications Technology Promotion), Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the MSIP (2015R1C1A1A01052268) and framework of international cooperation program managed by NRF (NRF-2015K2A1A2067635).

60 APPLIED LIFE SCIENCES↗

SU-F-T-294: The Analysis of Gamma Criteria for Delta4 Dosimetry Using Statistical Process Control

Purpose: To evaluate the sensitivity of gamma criteria for patient-specific volumetric modulated arc therapy(VMAT) quality assurance of the Delta{sup 4} dosimetry program using the statistical process control(SPC) methodology. Methods: The authors selected 20 patient-specific VMAT QA cases which were undertaken MapCHECK and ArcCHECK with gamma pass rate better than 97%. The QAs data were collected Delta4 Phantom+ and Elekta Agility six megavolts without using an angle incrementer. The gamma index(GI) were calculated in 2D planes with normalizing deviation to local dose(local gamma). The sensitivity of the GI methodology using criterion of 3%/3mm, 3%/2mm and 2%/3mm was analyzed with using process acceptability indices. We used local confidence(LC) level, the upper control limit(UCL) and lower control limit(LCL) of I-MR chart for process capability index(Cp) and a process acceptability index (Cpk). Results: The lower local confidence levels of 3%/3mm, 3%/2mm and 2%/3mm were 92.0%, 83.6% and 78.8% respectively. All of the calculated Cp and Cpk values that used LC level were under 1.0 in this study. The calculated LCLs of I-MR charts were 89.5%, 79.0% and 70.5% respectively. These values were higher than 1.0 which means good quality of QA. For the generally used lower limit of 90%, we acquired over 1.3 of Cp value for the gamma index of 3%/3mm and lower than 1.0 in the rest of GI. Conclusion: We applied SPC methodology to evaluate the sensitivity of gamma criteria and could see the lower control limits of VMAT QA for the Delta 4 dosimetry and could see that Delta 4 phantom+ dosimetry more affected by the position error and the I-MR chart derived values are more suitable for establishing lower limits. Acknowledgement: This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (No. 2015R1D1A1A01060463)

60 APPLIED LIFE SCIENCES↗

Partial Support of the Fast-Track Consensus Study on Foundational Research Gaps and Future Directions for Digital Twins (Final Report)

This study from the National Academies of Sciences, Engineering, and Medicine was launched to explore the foundational research gaps and opportunities for digital twins. As part of the information gathering process, the committee organized three targeted workshops—in engineering, climate sciences, and biomedical sciences—to better understand domain-specific nuances and barriers to developing digital twins. These sessions enabled cross-sector experts to surface field-specific needs, challenges, and open questions related to digital twins. Thousands of participants across multiple domains engaged in the discussions, which workshops were summarized in three separate Proceedings-in-Brief.

42 ENGINEERING↗

Los Alamos National Laboratory RD 2015 Profile

A vital, multidisciplinary national security science laboratory, Los Alamos National Laboratory applies science and technology to help solve the nation’s toughest challenges. Outstanding science is the foundation for the past, present, and future. A rich variety of research programs directly and indirectly support the Laboratory’s basic mission: to ensure the safety, security, and reliability of the nation’s nuclear deterrent; reduce global threats; and solve emerging national security energy challenges. The Laboratory also works on nuclear nonproliferation and border security, energy and infrastructure security, and measures to counter nuclear and biological terrorist threats.

99 GENERAL AND MISCELLANEOUS↗

HyMARC (Sandia) Annual Report

The Sandia HyMARC team continued its development of new synthetic, modeling, and diagnostic tools that are providing new insights into all major classes of storage materials, ranging from relatively simple systems such as PdHx and MgH2, to exceptionally complex ones, such as the metal borohydrides, as well as materials thought to be very well-understood, such as Ti-doped NaAlH4. This unprecedented suite of capabilities, capable of probing all relevant length scales within storage materials, is already having a significant impact, as they are now being used by both Seedling projects and collaborators at other laboratories within HyMARC. We expect this impact to grow as new Seedling projects begin and through collaborations with other scientists outside HyMARC. In the coming year, Sandia efforts will focus on the highest impact problems, in coordination with the other HyMARC National Laboratory partners, to provide the foundational science necessary to accelerate the discovery of new hydrogen storage materials.

36 MATERIALS SCIENCE↗

Advanced Research Directions on AI for Science, Energy, and Security: Report on Summer 2022 Workshops

Over the past decade, fundamental changes in artificial intelligence (AI)—from foundational to applied—have delivered dramatic insights across a wide breadth of U.S. Department of Energy (DOE) mission space. AI is helping to augment and improve scientific and engineering workflows (e.g., for control, design, and dramatic performance gains through surrogate models) in national security, the Office of Science, and DOE’s applied energy programs. The progress and potential for AI in DOE science was captured in the 2020 “AI for Science” report from the DOE laboratory community in collaboration with academia and industry. Specific scientific areas ready to further leverage the power of AI ranged from the scale and performance of computational models to data analysis to creating new classes of observations using computer vision. Since that report, the scale and scope of scientific AI have accelerated, revealing new, emergent properties that yield insights that go beyond enabling opportunities to being potentially transformative in the way that scientific problems are posed and solved. Thus, under the guidance of both the Office of Science (SC) and the National Nuclear Security Administration (NNSA), the DOE national laboratories organized a series of workshops in 2022 to gather input on new and rapidly emerging opportunities and challenges of scientific AI. This 2023 report is a synthesis of those workshops. The scientific community believes AI can have a foundational impact on a broad range of DOE missions, including science, energy, and national security. Further, DOE has unique capabilities that enable the community to drive progress in scientific use of AI, building on long-standing DOE strengths and investments in computation, data, and communications infrastructure, spanning the Energy Sciences Network (ESnet), the Exascale Computing Project (ECP), and integrative programs such as the NNSA Office of Defense Programs Advanced Simulation and Computing (ASC) and the SC Scientific Discovery through Advanced Computing (SciDAC) programs.

97 MATHEMATICS AND COMPUTING↗

LANL Continuity of Operations Plan

The Los Alamos National Laboratory (LANL) is a premier national security research institution, delivering scientific and engineering solutions for the nation's most crucial and complex problems. Our primary responsibility is to ensure the safety, security, and reliability of the nation's nuclear stockpile. LANL emphasizes worker safety, effective operational safeguards and security, and environmental stewardship, outstanding science remains the foundation of work at the Laboratory. In addition to supporting the Laboratory's core national security mission, our work advances bioscience, chemistry, computer science, earth and environmental sciences, materials science, and physics disciplines. To accomplish LANL's mission, we must ensure that the Laboratory EFs continue to be performed during a continuity event, including localized acts of nature, accidents, technological or attack-related emergencies, and pandemic or epidemic events. The LANL Continuity of Operations (COOP) Plan documents the overall LANL COOP Program and provides the operational framework to implement continuity policies, requirements, and responsibilities at LANL, as required by DOE 0 150.1, Continuity Programs, May 2008. LANL must maintain its ability to perform the nation's PMEFs, which are: (1) maintain the safety and security of nuclear materials in the DOE Complex at fixed sites and in transit; (2) respond to a nuclear incident, both domestically and internationally, caused by terrorist activity, natural disaster, or accident, including mobilizing the resources to support these efforts; and (3) support the nation's energy infrastructure. This plan supports Continuity of Operations for Los Alamos National Laboratory (LANL). This plan issues LANL policy as directed by the DOE 0 150.1, Continuity Programs, and provides direction for the orderly continuation of LANL EFs for 30 days of closure or 60 days for a pandemic/epidemic event. Initiation of COOP operations may be required to support an allhazards event, including a national security emergency, major fire, catastrophic natural disaster, man-made disaster, terrorism event, or technological disaster by rendering LANL buildings, infrastructure, or Technical Areas unsafe, temporarily unusable, or inaccessible.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Strategy for NACS investment in Machine Learning

The Nuclear and Chemical Sciences (NACS) Division furnishes the expertise in the scientific areas of chemical, nuclear and isotopic sciences that are foundational in the Laboratory’s national security missions. This expertise is maintained and advanced through identification, development and application of state-of-the-art theoretical, computational and experimental methods and tools. Recent developments in artificial intelligence and machine learning (AI/ML) techniques enabled by advances in computing capabilities and widespread availability of powerful software implementations have made use of these techniques ubiquitous across both science and industry. While the scope of AI/ML applications is incredibly large and evolves very rapidly, the topics most relevant to NACS missions fall into the general category of detecting, categorizing or identifying features in large, complex datasets using either supervised or unsupervised learning. This covers both basic scientific data analysis and the development of efficient surrogate models of real-life technological systems, experimental detectors, or theoretical models. To remain at the forefront of its core scientific disciplines, NACS must both cultivate ML expertise as well as continuously explore applying this expertise to new problems or utilizing new methods. This document identifies the key areas where this support is critical and provides a strategy for investing in them.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

NASA’s Earth System Observatory Formulation Progress

The 2017 Earth Science Decadal Survey by the National Academies of Science, Engineering, and Medicine identified five foundational observations, or Designated Observables (DO), to be implemented as missions by NASA. To address these five DO areas – Surface Biology and Geology; Mass Change; Aerosols; Cloud, Convection, and Precipitation; and Surface Deformation and Change – NASA is developing the Earth System Observatory (ESO) as an array of Earth-focused, interconnected satellite missions. The ESO will build on the strong history of international partnerships in NASA Earth science, with initial participation and collaboration on these missions across space agency partners including the Japanese Aerospace Exploration Agency (JAXA), Centre National D'Etudes Spatiales (CNES), Canadian Space Agency (CSA), Deutsches Zentrum für Luft- und Raumfahrt (DLR), and Agenzia Spaziale Italiana (ASI). Targeting launch dates in the late 2020s and early 2030s, the ESO will work as a single observatory, with each satellite in the ESO delivering its own valuable information, but taken together, the data and imagery will provide the global community with a multidimensional, holistic view of the Earth. In addition to furthering the world’s scientific knowledge, data gathered by ESO missions will provide actionable science to inform decisions related to climate change, disaster mitigation, and wildfires, improve real-time agricultural processes, and many other applications. This paper will provide an overview of the ESO development activities, as well as an update on the individual ESO missions currently in formulation – Atmosphere Observing System, Gravity Recovery and Climate Experiment-Continuity, and Surface Biology and Geology – including current mission architectures and concepts, international partner collaboration, science community engagement, and applications efforts, as well as how ESO data will be freely open and accessible to users all over the world.

NASA Earth Science↗

SU-E-T-294: Dosimetric Analysis of Planning Phase Using Overlap Volume Histogram for Respiratory Gated Radiotherapy

Purpose: End-of-exhale (EOE) phase is generally preferred for gating window because tumor position is more reproducible. However, other gating windows might be more appropriate for dose distribution perspective. In this pilot study, we proposed to utilize overlap volume histogram (OVH) to search optimized gating window and demonstrated its feasibility. Methods: We acquired 4DCT of 10 phases for 3 lung patients (2 with a target at right middle lobe and 1 at right upper lobe). After structures were defined in every phase, the OVH of each OAR was generated to quantify the three dimensional spatial relationship between the PTV and OARs (bronchus, esophagus, heart and cord etc.) at each phase. OVH tells the overlap volume of an OAR according to outward distance from the PTV. Relative overlap volume at 20 mm outward distance from the PTV (ROV-20) was also defined as a metric for measuring overlap volume and obtained. For dose calculation, 3D CRT plans were made for all phases under the same beam angles and objectives (e.g., 95% of the PTV coverage with at least 100% of the prescription dose of 50 Gy). The gating window phase was ranked according to ROV-20, and the relationship between the OVH and dose distribution at each phase was evaluated by comparing the maximum dose, mean dose, and equivalent uniform dose of OAR. Results: OVHs showed noticeable difference from phase to phase, implying it is possible to find optimal phases for gating window. For 2 out of 3 patients (both with a target at RML), maximum dose, mean dose, and EUD increased as ROV-20 increased. Conclusion: It is demonstrated that optimal phases (in dose distribution perspective) for gating window could exist and OVH can be a useful tool for determining such phases without performing dose optimization calculations in all phases. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2012-007883) through the National Research Foundation (NRF) funded by the Ministry of Science, ICT & Future Planning (MSIP) of Korea.

60 APPLIED LIFE SCIENCES↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗

High Quantum Efficiency Uni-Traveling-Carrier Photodiode for Optical to Microwave Transduction

Modern Quantum Information Systems (QIS) employ optical photons for long distance communication, operating at ambient temperature, between microwave cavities, which house microwave photons used in quantum computing and microwave detection. These optical photons, carried by fiber-optic or free-space links, offer a low-cost, uncooled alternative to bulky, expensive microwave coaxial cables, which are lossy, susceptible to EMI, and a significant thermal conductor to the outside ambient environment. To convert between these two types of photons and implement these optical interconnects, it is necessary to develop a high-performance photodetector for optical to microwave transduction. Freedom Photonics and the University of Virginia have a well-established partnership in developing high-performance photodiodes. In this Phase I effort, we collaborated in designing, fabricating, and testing an advanced, high-speed, high quantum efficiency prototype photodiode for transduction from optical to microwave frequencies. These devices have applications not only in quantum computing and axion detection, but also in other optical-cryogenic interconnect applications, in fields such as radio astronomy and quantum cryptography, as well as in quantum metrology and plasmonics. During this Phase I DOE program, we designed, fabricated, and tested prototype PIN GaAs photodiodes which targeted the performance parameters defined by the program. This process involved identifying a new target wavelength, different from that proposed initially, based on conversations with the Oak Ridge National Lab customer. We designed an epitaxial stack, optimized in theory for ≥95% quantum efficiency at 795 nm, ≥5 GHz, per the target objectives of the program. Additionally, we designed a fabrication process and associated mask plates for top-illuminated, AR-coated devices with device diameters ranging from 50 µm to 800 µm. Using these, we fabricated two 3” wafer quarters of devices, and characterized the devices’ dark current, quantum efficiency, and bandwidth for various device diameters. The prototype devices achieved a quantum efficiency of 89% at the target 795 nm detection wavelength. The bandwidth of the devices proved tricky to characterize, but a 50 µm diameter device shows a 3-dB bandwidth of at least 1.6 GHz, possibly a full 5 GHz, depending on the measurement setup. In the future, we plan to characterize the bandwidth of these devices using an impulse response measurement. All tasks for the Phase I were successfully completed, and sample prototype devices were provided to Oak Ridge National Lab Quantum Information Science researchers. The work performed in Phase I has established a strong foundation for future design and fabrication cycles in Phase II, if granted. The early tests at Oak Ridge National Labs will provide guidance for the required photodiode performance in devices to be supplied in Phase II.

42 ENGINEERING↗

SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure level of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-C-207-01: Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation

Purpose: In past few years, the inverse geometry computed tomography (IGCT) system has been developed to overcome shortcomings of a conventional computed tomography (CT) system such as scatter problem induced from large detector size and cone-beam artifact. In this study, we intend to present a concept of a four-dimensional (4D) IGCT system that has positive aspects above all with temporal resolution for dynamic studies and reduction of motion artifact. Methods: Contrary to conventional CT system, projection data at a certain angle in IGCT was a group of fractionated narrow cone-beam projection data, projection group (PG), acquired from multi-source array which have extremely short time gap of sequential operation between each of sources. At this, for 4D IGCT imaging, time-related data acquisition parameters were determined by combining multi-source scanning time for collecting one PG with conventional 4D CBCT data acquisition sequence. Over a gantry rotation, acquired PGs from multi-source array were tagged time and angle for 4D image reconstruction. Acquired PGs were sorted into 10 phase and image reconstructions were independently performed at each phase. Image reconstruction algorithm based upon filtered-backprojection was used in this study. Results: The 4D IGCT had uniform image without cone-beam artifact on the contrary to 4D CBCT image. In addition, the 4D IGCT images of each phase had no significant artifact induced from motion compared with 3D CT. Conclusion: The 4D IGCT image seems to give relatively accurate dynamic information of patient anatomy based on the results were more endurable than 3D CT about motion artifact. From this, it will be useful for dynamic study and respiratory-correlated radiation therapy. This work was supported by the Industrial R&D program of MOTIE/KEIT [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-E-J-110: Dosimetric Analysis of Respiratory Motion Based On Four-Dimensional Dose Accumulation in Liver Stereotactic Body Radiotherapy

Purpose: Respiratory motion in thoracic and abdominal region could lead to significant underdosing of target and increased dose to healthy tissues. The aim of this study is to evaluate the dosimetric effect of respiratory motion in conventional 3D dose by comparing 4D deformable dose in liver stereotactic body radiotherapy (SBRT). Methods: Five patients who had previously treated liver SBRT were included in this study. Four-dimensional computed tomography (4DCT) images with 10 phases for all patients were acquired on multi-slice CT scanner (Siemens, Somatom definition). Conventional 3D planning was performed using the average intensity projection (AIP) images. 4D dose accumulation was calculated by summation of dose distribution for all phase images of 4DCT using deformable image registration (DIR) . The target volume and normal organs dose were evaluated with the 4D dose and compared with those from 3D dose. And also, Index of achievement (IOA) which assesses the consistency between planned dose and prescription dose was used to compare target dose distribution between 3D and 4D dose. Results: Although the 3D dose calculation considered the moving target coverage, significant differences of various dosimetric parameters between 4D and 3D dose were observed in normal organs and PTV. The conventional 3D dose overestimated dose to PTV, however, there was no significant difference for GTV. The average difference of IOA which become ‘1’ in an ideal case was 3.2% in PTV. The average difference of liver and duodenum was 5% and 16% respectively. Conclusion: 4D dose accumulation which can provide dosimetric effect of respiratory motion has a possibility to predict the more accurate delivered dose to target and normal organs and improve treatment accuracy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning (MSIP) of Korea.

60 APPLIED LIFE SCIENCES↗