Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Determining the 3-D structure and motion of objects using a scanning laser range sensor

In order for the EVAHR robot to autonomously track and grasp objects, its vision system must be able to determine the 3-D structure and motion of an object from a sequence of sensory images. This task is accomplished by the use of a laser radar range sensor which provides dense range maps of the scene. Unfortunately, the currently available laser radar range cameras use a sequential scanning approach which complicates image analysis. Although many algorithms have been developed for recognizing objects from range images, none are suited for use with single beam, scanning, time-of-flight sensors because all previous algorithms assume instantaneous acquisition of the entire image. This assumption is invalid since the EVAHR robot is equipped with a sequential scanning laser range sensor. If an object is moving while being imaged by the device, the apparent structure of the object can be significantly distorted due to the significant non-zero delay time between sampling each image pixel. If an estimate of the motion of the object can be determined, this distortion can be eliminated; but, this leads to the motion-structure paradox - most existing algorithms for 3-D motion estimation use the structure of objects to parameterize their motions. The goal of this research is to design a rigid-body motion recovery technique which overcomes this limitation. The method being developed is an iterative, linear, feature-based approach which uses the non-zero image acquisition time constraint to accurately recover the motion parameters from the distorted structure of the 3-D range maps. Once the motion parameters are determined, the structural distortion in the range images is corrected.

Nandhakumar, N.↗

Susceptibility of the squirrel monkey to different motion conditions

The exact stimulus eliciting vomiting in animal studies of motion sickness is difficult to specify because the vestibular stimulation produced by many motion conditions is confounded by voluntary movements with animals. This is an important problem because experiments with animal models of motion sickness can provide useful information about antimotion sickness drugs or the role of neural mechanisms, only when animals are exposed to the same motion stimuli in each experimental session. A series of tests were conducted to determine the susceptibility of 15 adult squirrel monkeys to motion sickness in freely moving and restrained test conditions. Canal stimulation was varied by exposing the monkey in freely moving conditions to varying degrees of angular velocity (60, 90, 120, 150 deg/sec), and in restrained conditions to one angular velocity (150 deg/sec) and to cross-coupling effects of whole-body roll movements during rotation. Otolith stimulation was investigated by using sinusoidal vertical linear acceleration during free movement conditions, and off-vertical rotation and earth-horizontal (BBQ) rotation while restrained. The percentage of freely moving animal vomiting during vertical axis rotation was 27, 93, 86, and 92 for the angular velocities of 60, 90, 120, and 150 deg/sec respectively. None of the monkeys vomited during vertical axis rotation or cross-coupled rotation when restrained. Otolith stimulation appears to be a less provocative stimulus for the squirrel monkey as the percentage of animals vomiting were 13, 0, and 7 for the conditions of free movement during oscillation, restraint during off-vertical, and BBQ rotation respectively. Motion sickness to the point of vomiting occurred regularly only in conditions where self-motion was possible. Such effects could occur because voluntary movement during motion augments vestibular effects by producing self-inflicted cross-coupling, but the failure to elicit vomiting with experimenter-coupling cross-coupling argues against this interpretation. Alternatively, these results might imply that feedback from movement control mechanisms may play an important role in sensory conflict as suggested by Oman's sensory-motor conflict theory.

R A Fox↗

Concept verification of three dimensional free motion simulator for space robot

In the development of automatic assembling technologies for space structures, it is an indispensable matter to investigate and simulate the movements of robot satellites concerned with mission operation. The movement investigation and simulation on the ground will be effectively realized by a free motion simulator. Various types of ground systems for simulating free motion have been proposed and utilized. Some of these methods are a neutral buoyancy system, an air or magnetic suspension system, a passive suspension balance system, and a free flying aircraft or drop tower system. In addition, systems can be simulated by computers using an analytical model. Each free motion simulation method has limitations and well known problems, specifically, disturbance by water viscosity, limited number of degrees-of-freedom, complex dynamics induced by the attachment of the simulation system, short experiment time, and the lack of high speed super-computer simulation systems, respectively. The basic idea presented here is to realize 3-dimensional free motion. This is achieved by combining a spherical air bearing, a cylindrical air bearing, and a flat air bearing. A conventional air bearing system has difficulty realizing free vertical motion suspension. The idea of free vertical suspension is that a cylindrical air bearing and counter balance weight realize vertical free motion. This paper presents a design concept, configuration, and basic performance characteristics of an innovative free motion simulator. A prototype simulator verifies the feasibility of 3-dimensional free motion simulation.

Okamoto, Osamu↗

Hybrid Motion Planning with Multiple Destinations

In our initial proposal, we laid plans for developing a hybrid motion planning system that combines the concepts of visibility-based motion planning, artificial potential field based motion planning, evolutionary constrained optimization, and reinforcement learning. Our goal was, and still is, to produce a hybrid motion planning system that outperforms the best traditional motion planning systems on problems with dynamic environments. The proposed hybrid system will be in two parts the first is a global motion planning system and the second is a local motion planning system. The global system will take global information about the environment, such as the placement of the obstacles and goals, and produce feasible paths through those obstacles. We envision a system that combines the evolutionary-based optimization and visibility-based motion planning to achieve this end.

Clouse, Jeffery↗

An Initial Examination of Roll-Lateral Coordination Motion Requirements in Flight Simulation

A piloted simulation that examined the effects of uncoordinated roll-lateral motion cues from a coordinated math model was conducted. The vehicle model represented a typical helicopter with satisfactory handling qualities in the roll-lateral axes. The task was a two-degree-of-freedom horizontal sidestep, where the pilot controlled lateral position through roll angle. The motion platform commands were varied via two motion control system gains. One gain reduced the ratio between platform roll angle to math model (and thus visual) roll angle. The other gain was placed on how much lateral platform movement would result from platform roll attitude in an attempt to align the apparent gravity vector vertically relative to the pilot. Gains from one to zero were examined in both axes. Thus, the true 1:1 motion case, where the motion cues matched the visual cues was evaluated. Pilots subjective ratings of motion fidelity matched well against an earlier developed motion fidelity criteria. Significant differences were noted in the fixed-base versus motion base configurations.

Schroeder, Jeffery A.↗

Feasibility of Measuring Mean Vertical Motion for Estimating Advection

Numerous recent studies calculate horizontal and vertical advection terms for budget studies of net ecosystem exchange of carbon. One potential uncertainty in such studies is the estimate of mean vertical motion. This work addresses the reliability of vertical advection estimates by contrasting the vertical motion obtained from the standard practise of measuring the vertical velocity and applying a tilt correction, to the vertical motion calculated from measurements of the horizontal divergence of the flow using a network of towers. Results are compared for three different tilt correction methods. Estimates of mean vertical motion are sensitive to the choice of tilt correction method. The short-term mean (10 to 60 minutes) vertical motion based on the horizontal divergence is more realistic compared to the estimates derived from the standard practise. The divergence shows long-term mean (days to months) sinking motion at the site, apparently due to the surface roughness change. Because all the tilt correction methods rely on the assumption that the long-term mean vertical motion is zero for a given wind direction, they fail to reproduce the vertical motion based on the divergence.

Vickers, Dean↗

Evaluating Effectiveness of Modeling Motion System Feedback in the Enhanced Hess Structural Model of the Human Operator

In order to use the Hess Structural Model to predict the need for certain cueing systems, George and Cardullo significantly expanded it by adding motion feedback to the model and incorporating models of the motion system dynamics, motion cueing algorithm and a vestibular system. This paper proposes a methodology to evaluate effectiveness of these innovations by performing a comparison analysis of the model performance with and without the expanded motion feedback. The proposed methodology is composed of two stages. The first stage involves fine-tuning parameters of the original Hess structural model in order to match the actual control behavior recorded during the experiments at NASA Visual Motion Simulator (VMS) facility. The parameter tuning procedure utilizes a new automated parameter identification technique, which was developed at the Man-Machine Systems Lab at SUNY Binghamton. In the second stage of the proposed methodology, an expanded motion feedback is added to the structural model. The resulting performance of the model is then compared to that of the original one. As proposed by Hess, metrics to evaluate the performance of the models include comparison against the crossover models standards imposed on the crossover frequency and phase margin of the overall man-machine system. Preliminary results indicate the advantage of having the model of the motion system and motion cueing incorporated into the model of the human operator. It is also demonstrated that the crossover frequency and the phase margin of the expanded model are well within the limits imposed by the crossover model.

Zaychik, Kirill↗

Motion-Corrected 3D Sonic Anemometer for Tethersondes and Other Moving Platforms

To date, it has not been possible to apply 3D sonic anemometers on tethersondes or similar atmospheric research platforms due to the motion of the supporting platform. A tethersonde module including both a 3D sonic anemometer and associated motion correction sensors has been developed, enabling motion-corrected 3D winds to be measured from a moving platform such as a tethersonde. Blimps and other similar lifting systems are used to support tethersondes meteorological devices that fly on the tether of a blimp or similar platform. To date, tethersondes have been limited to making basic meteorological measurements (pressure, temperature, humidity, and wind speed and direction). The motion of the tethersonde has precluded the addition of 3D sonic anemometers, which can be used for high-speed flux measurements, thereby limiting what has been achieved to date with tethersondes. The tethersonde modules fly on a tether that can be constantly moving and swaying. This would introduce enormous error into the output of an uncorrected 3D sonic anemometer. The motion correction that is required must be implemented in a low-weight, low-cost manner to be suitable for this application. Until now, flux measurements using 3D sonic anemometers could only be made if the 3D sonic anemometer was located on a rigid, fixed platform such as a tower. This limited the areas in which they could be set up and used. The purpose of the innovation was to enable precise 3D wind and flux measurements to be made using tether - sondes. In brief, a 3D accelerometer and a 3D gyroscope were added to a tethersonde module along with a 3D sonic anemometer. This combination allowed for the necessary package motions to be measured, which were then mathematically combined with the measured winds to yield motion-corrected 3D winds. At the time of this reporting, no tethersonde has been able to make any wind measurement other than a basic wind speed and direction measurement. The addition of a 3D sonic anemometer is unique, as is the addition of the motion-correction sensors.

Bognar, John↗

Galvanic Vestibular Reduction Modifies Perception of Coriolis Cross-Coupling and Delays Motion Sickness Onset

INTRODUCTION: Alterations in vestibular sensory processing following G-transitions lead to head movement sensitivity and motion sickness upon return to Earth’s gravity. The purpose of this study was to evaluate whether a non-pharmaceutical tool using galvanic vestibular reduction (GVR) could suppress disorienting illusions and mitigate motion sickness. A similar approach using anodal (inhibitory) currents delivered to both ears has been shown to result in a selective reversible ablation of irregular vestibular afferents [1]. METHODS: Using a repeated measures counter-balanced design, motion sickness and perception were obtained in 26 subjects during Coriolis cross-coupling stimuli on a rotating chair across three GVR treatment interventions: throughout stimulus testing (prevention), following symptom onset (rescue), and placebo control. The GVR peak current was maintained at 2.5 mA across subjects and across prevention / rescue sessions. Subjects performed up to 10 sets of pitch head movements during constant rotation. For each set, head movement was cued every 10 seconds, alternating between pitch forward (chin resting to chest) and pitch backward (head upright) for a total of 7 forward and backward movements. During each head movement, subjects were asked to use a joystick to record the magnitude of their perceived rotation along three axes. During the 2-minute pause between sets, motion sickness symptom scoring was obtained using the Pensacola Diagnostic Index and subject discomfort (0-20) ratings. Performance on a sensorimotor and cognitive test battery was measured during a fourth session to map changes in GVR level with functional performance. RESULTS: Fourteen of the 26 subjects were not susceptible to the motion stressor (i.e., did not reach an endpoint in the control condition). While the time to endpoint, or number of head movements, did not significantly vary across the three GVR conditions in the remaining subjects, the symptom levels were significantly lower through the third set of head movements when GVR was on throughout the testing. Initiating GVR following symptom onset did not appear to alter the symptom progression nor time to motion sickness endpoint. Based on the joystick measures, GVR significantly modified the perceived roll and pitch sensation during head movements, reducing the amplitude of tilt in most subjects. It is important to note that comparable levels of GVR did not impair performance on a functional test battery including mobility, balance and cognitive tasks. DISCUSSION: Our findings suggest GVR may be useful in reducing disorienting roll and pitch illusions and delaying the onset of motion sickness. Further enhancements will be required to individualize the stimulation amplitude and optimize the waveform delivery. Adapting this non-pharmaceutical countermeasure approach to allow self-administered titration of current amplitude during recovery would enable transfer to post-flight treatment of motion sickness. [1] Minor L. B. and Goldberg J. M. (1991) J Neurosci 11, 1636-48. 109, 889-894.

G N Pradhan↗

Engineering evaluation of the EQSIM simulated ground-motion database: The San Francisco Bay Area region

Ground-motion simulations for infrequent earthquake scenarios are gaining increasing interest in the engineering community for their potential to inform performance-based structural design and assessment, particularly in regions where major earthquakes are expected, but recordings from consistent historical events are not available. However, the absence of empirical data makes the evaluation of such scenarios and the interpretation of the simulation results very challenging. In this context, this paper presents the evaluation of the first EQSIM (v.1.1.0) ground-motion simulations generated for the San Francisco Bay Area (SFBA) region. The current database, which is at the first stages of development, includes eight realizations of a Hayward Fault M w 7 event. The evaluation of the simulated motions is first conducted on the average ground-motion amplitudes through comparison against the NGA-W2 GMPEs and a selected population of real records. A methodology for selecting a population of real records consistent with the simulated event is proposed. The objective of the proposed evaluation is twofold: (1) build confidence in the realistic character of the simulated motions for their use in engineering applications and (2) offer a critical physics-based interpretation of the simulation results that can help improve key features of the simulation models. To further investigate the implications of using the simulated ground motions for site-specific structural assessments, the ASCE7-16 approach is employed for the analysis of two hazard-consistent near-field sites in the SFBA. Results are discussed. Furthermore, this study offers a critical review of the EQSIM (v.1.1.0) SFBA ground-motion simulations and suggestions for improving the earthquake rupture models.

58 GEOSCIENCES↗

NEW LIMITS ON AN INTERMEDIATE-MASS BLACK HOLE IN OMEGA CENTAURI. I. HUBBLE SPACE TELESCOPE PHOTOMETRY AND PROPER MOTIONS

We analyze data from the Hubble Space Telescope's (HST) Advanced Camera for Surveys of the globular cluster (GC) Omega Cen. We construct a photometric catalog of 1.2 x 10{sup 6} stars over a 10' x 10' central field down to below B{sub F435W} = 25 (M {approx} 0.35 M{sub sun}). The 2.5 to 4 year baseline between observations yields a catalog of some 10{sup 5} proper motions over a smaller area, with 53,382 'high-quality' measurements in a central R {approx}< 2' field. Artificial-star tests characterize the photometric incompleteness. We determine the cluster center to {approx}1'' accuracy from star counts using two different methods, one based on isodensity contours and the other on 'pie slices'. We independently confirm the result by determining also the kinematical center of the HST proper motions, as well as the center of unresolved light seen in Two Micron All Sky Survey data. All results agree to within their 1''-2'' levels of uncertainty. The proper-motion dispersion of the cluster increases gradually inward, but there is no variation in kinematics with position within the central {approx}15'': there is no dispersion cusp and no stars with unusually high velocities. We measure for the first time in any GC the variation in internal kinematics along the main sequence. The variation of proper-motion dispersion with mass shows that the cluster is not yet in equipartition. There are no differences in proper-motion kinematics between the different stellar populations of Omega Cen. Our results do not confirm the arguments put forward by Noyola, Gebhardt, and Bergmann to suspect an intermediate-mass black hole (IMBH) in Omega Cen. They determined line-of-sight velocity dispersions in two 5'' x 5'' fields, and reported higher motions in their central field. We find the proper-motion kinematics to be the same in both fields. Also, we find that they (as well as other previous studies) did not accurately identify the cluster center, so that both of their fields are in fact 12'' from the true center. We also do not confirm the central density cusp they reported (in part due to the different center, and in part due to biases induced by their use of unresolved light). The surface number-density distribution near the center does not differ strongly from a single-mass King model, although a shallow cusp may not be ruled out. In the companion paper, which is Paper II in this series, we present new dynamical models for the high-quality data presented here, with the aim of putting quantitative constraints on the mass of any possible IMBH.

79 ASTRONOMY AND ASTROPHYSICS↗

DISTANCE AND PROPER MOTION MEASUREMENT OF THE RED SUPERGIANT, S PERSEI, WITH VLBI H{sub 2}O MASER ASTROMETRY

We have conducted Very Long Baseline Array phase-referencing monitoring of H{sub 2}O masers around the red supergiant, S Persei, for six years. We have fitted maser motions to a simple expanding-shell model with a common annual parallax and stellar proper motion, and obtained the annual parallax as 0.413 {+-} 0.017 mas and the stellar proper motion as (-0.49 {+-} 0.23 mas yr{sup -1}, -1.19 {+-} 0.20 mas yr{sup -1}) in right ascension and declination, respectively. The obtained annual parallax corresponds to the trigonometric distance of 2.42{sup +0.11}{sub -0.09} kpc. Assuming a Galactocentric distance of the Sun of 8.5 kpc, the circular rotational velocity of the local standard of rest at a distance of the Sun of 220 km s{sup -1}, and a flat Galactic rotation curve, S Persei is suggested to have a non-circular motion deviating from the Galactic circular rotation for 15 km s{sup -1}, which is mainly dominated by the anti-rotation direction component of 12.9 {+-} 2.9 km s{sup -1}. This red supergiant is thought to belong to the OB association, Per OB1, so that this non-circular motion is representative of a motion of the OB association in the Milky Way. This non-circular motion is somewhat larger than that explained by the standard density-wave theory for a spiral galaxy and is attributed to either a cluster shuffling of the OB association, or to non-linear interactions between non-stationary spiral arms and multi-phase interstellar media. The latter comes from a new view of a spiral arm formation in the Milky Way suggested by recent large N-body/smoothed particle hydrodynamics numerical simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

A FIRST MEASUREMENT OF THE PROPER MOTION OF THE LEO II DWARF SPHEROIDAL GALAXY

We use 14 year baseline images obtained with the Wide Field and Planetary Camera 2 on board the Hubble Space Telescope (HST) to derive a proper motion for one of the Milky Way's most distant dwarf spheroidal companions, Leo II, relative to an extragalactic background reference frame. Astrometric measurements are performed in the effective point-spread function formalism using our own developed code. An astrometric reference grid is defined using 3224 stars that are members of Leo II and brighter than a magnitude of 25 in the F814W band. We identify 17 compact extragalactic sources, for which we measure a systemic proper motion relative to this stellar reference grid. We derive a proper motion [{mu}{sub {alpha},{mu}{delta}}] = [+104 {+-}113,-33 {+-} 151] {mu}as yr{sup -1} for Leo II in the heliocentric reference frame. Though marginally detected, the proper motion yields constraints on the orbit of Leo II. Given a distance of d {approx_equal} 230 kpc and a heliocentric radial velocity v{sub r} = +79 km s{sup -1}, and after subtraction of the solar motion, our measurement indicates a total orbital motion v{sub G} = 266.1 {+-} 128.7 km s{sup -1} in the Galactocentric reference frame, with a radial component v{sub r{sub G}}=21.5{+-}4.3 km s{sup -1} and tangential component v{sub t{sub G}} = 265.2 {+-} 129.4 km s{sup -1}. The small radial component indicates that Leo II either has a low-eccentricity orbit or is currently close to perigalacticon or apogalacticon distance. We see evidence for systematic errors in the astrometry of the extragalactic sources which, while close to being point sources, are slightly resolved in the HST images. We argue that more extensive observations at later epochs will be necessary to better constrain the proper motion of Leo II. We provide a detailed catalog of the stellar and extragalactic sources identified in the HST data which should provide a solid early-epoch reference for future astrometric measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Interfraction and Intrafraction Changes in Amplitude of Breathing Motion in Stereotactic Liver Radiotherapy

Purpose: Interfraction and intrafraction changes in amplitude of liver motion were assessed in patients with liver cancer treated with kV cone beam computed tomography (CBCT)-guided stereotactic body radiation therapy (SBRT). Methods and Materials: A total of 314 CBCTs obtained with the patient in the treatment position immediately before and after each fraction, and 29 planning 4DCTs were evaluated in 29 patients undergoing six-fraction SBRT for unresectable liver cancer, with (n = 15) and without (n = 14) abdominal compression. Offline, the CBCTs were sorted into 10 bins, based on phase of respiration. Liver motion amplitude was measured using liver-to-liver alignment from the end-exhale and end-inhale CBCT and four-dimensional CT reconstructions. Inter- and intrafraction amplitude changes were measured from the difference between the pre-SBRT CBCTs relative to the planning four-dimensional CT, and from the pre-SBRT and post-SBRT CBCTs, respectively. Results: Mean liver motion amplitude for all patients (range) was 1.8 (0.1-7.0), 8.0 (0.1-18.8), and 4.3 (0.1-12.1) mm in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. Mean absolute inter- and intrafraction liver motion amplitude changes were 1.0 (ML), 1.7 (CC), and 1.6 (AP) mm and 1.3 (ML), 1.6 (CC), and 1.9 (AP) mm, respectively. No significant correlations were found between intrafraction amplitude change and intrafraction time (range, 4:56-25:37min:sec), and between inter- and intrafraction amplitude changes and liver motion amplitude. Intraobserver reproducibility ({sigma}, n = 29 fractions) was 1.3 (ML), 1.4 (CC), and 1.4 (AP) mm. Conclusions: For the majority of liver SBRT patients, the change in liver motion amplitude was minimal over the treatment course and showed no apparent relationships with the magnitude of liver motion and intrafraction time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Rigid and Nonrigid Motion of Liver Tumors During Stereotactic Body Radiation Therapy

Purpose: To quantify rigid and nonrigid motion of liver tumors using reconstructed 3-dimensional (3D) fiducials from stereo imaging during CyberKnife-based stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty-three liver patients treated with 3 fractions of SBRT were used in this study. After 2 orthogonal kilovoltage images were taken during treatment, the 3D locations of the fiducials were generated by the CyberKnife system and validated using geometric derivations. A total of 4824 pairs of kilovoltage images from start to end of treatment were analyzed. For rigid motion, the rotational angles and translational shifts were reported by aligning 3D fiducial groups from different image pairs, using least-squares fitting. For nonrigid motion, we quantified interfractional tumor volume variations by using the proportional volume derived from the fiducials, which correlates to the sum of interfiducial distances. The individual fiducial displacements were also reported (1) after rigid corrections and (2) without angle corrections. Results: The proportional volume derived by the fiducials demonstrated a volume-increasing trend in the second (101.9% ± 3.6%) and third (101.0 ± 5.9%) fractions among most patients, possibly due to radiation-induced edema. For all patients, the translational shifts in left-right, anteroposterior, and superoinferior directions were 2.1 ± 2.3 mm, 2.9 ± 2.8 mm, and 6.4 ± 5.5 mm, respectively. The greatest translational shifts occurred in the superoinferior direction, likely due to respiratory motion from the diaphragm. The rotational angles in roll, pitch, and yaw were 1.2° ± 1.8°, 1.8° ± 2.4°, and 1.7° ± 2.1°, respectively. The 3D individual fiducial displacements with rigid corrections were 0.2 ± 0.2 mm and increased to 0.5 ± 0.4 mm without rotational corrections. Conclusions: Accurate 3D locations of internal fiducials can be reconstructed from stereo imaging during treatment. As an effective surrogate to tumor motion, fiducials provide a close estimation of both rigid and nonrigid motion of liver tumors. The reported displacements could be further utilized for tumor margin definition and motion management in conventional linear accelerator–based liver SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 {+-} 1.5 treatment fractions; motion data were acquired for a mean of 26 {+-} 6.2 fractions. The mean age was 15.6 {+-} 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Frequency Seismic Ground Motion At The Pier Positions Of The Planned Messina Straits Bridge For A Realistic Earthquake Scenario

We estimated longer-period (period T>0.5 s) components of the ground motion at the piers of the planned Messina straits bridge. As the shortest fault-to-site distance is only 3-5 km, the kinematic earthquake rupture process has to be described in a realistic way and thus, the causative fault is represented by a dense grid of subfaults. To model the 1908 event, we assume a Mw = 7 earthquake, with a 40x20 km rectangular fault, and pure reverse dip-slip. The horizontal upper side of the rectangle is at 3-km depth, and the N corner of the rectangle is just between the piers. For the fault nucleation point, the least favorable place is assumed and a randomized rupture velocity is used in a particular run. In a typical simulation, the fault motion is initially represented by the time history of slip in each of the subfaults and by the distribution of the final seismic moment among the subsources (forming 'asperities'), both generated as lognormal random functions. The time histories are then filtered in order to fit a chosen source spectral model. The parameters that are conditioning the random functions can be based on the bulk of published fault inversions, or reproduced from an earlier successful attempt to simulate ground motions in the epicentral zone of the 1994, M = 6.7 Northridge, California, earthquake. In the second step of calculations, the Green functions (for each subfault and pier combination) are calculated for a layered halfspace model of the pier foundation stratigraphy, using an advanced Green function calculator, that allows an accurate calculation over the entire relevant frequency band including static terms. Finally, the 3-components of the strong ground motion are obtained at the two piers through convolution and summation over the different subsources. We compare a set of response horizontal velocity spectra (PRV) obtained from our calculations with a reference PRV that is considered as a reasonable upper bound for the possible ground motion near the piers. Our results suggest that the seismic ground motion under Torre Sicilia dominates over this under Torre Calabria and that the median (average log) PRV is generally above the reference one, about 1.1-1.3 times for T>4 s, and up to 2 times for 1<T{<=}4 s. The use of advanced fault and medium models, accounting also for the natural scatter of individual PRV due to events with the same gross source parameters, provides a sound basis for the deterministic engineering estimates of future seismic ground motion.

58 GEOSCIENCES↗

The Equations of Motion of Compact Binaries in the Neighborhood of Supermassive Black Hole

By the use of Einstein-Infeld-Hoffmann method, the equations of motion of a binary star system in the field of a supermassive black hole are derived. In spite of the fact that the motion of a binary system as a whole can be relativistic or even ultra-relativistic with respect to the supermassive black hole, it is shown, that under the assumption of non-relativistic relative motion of the stars in binary system, the motion of the binary system as a whole satisfies the Mathisson-Papapetrou equations with additional terms depending on quadrupole moments. Exemplary case of ultrarelativistic motion of a binary neutron star in the vicinity of non-rotating black hole is considered. It it shown that the motion of binary's center of mass may considerably differ from geodesic motion.

79 ASTRONOMY AND ASTROPHYSICS↗