Financial Impacts of Net-Metered Distributed PV on a Prototypical Western Utility’s Shareholders and Ratepayers

Distributed solar photovoltaic (DPV) under net-energy metering with volumetric retail electricity pricing has raised concerns among utilities and regulators about adverse financial impacts for shareholders and ratepayers. Using a pro forma financial model, we estimate the financial impacts of different DPV deployment levels on a prototypical Western U.S. investor-owned utility under a varied set of operating conditions that would be expected to affect the value of DPV. Our results show that the financial impacts on shareholders and ratepayers increase as the level of DPV deployment increases, though the magnitude is small even at high DPV penetration levels. Even rather dramatic changes in DPV value result in modest changes to shareholder and ratepayer impacts, but the impacts on the former are greater than the latter (in percentage terms). The range of financial impacts are driven by differences in the amount of incremental capital investment that is deferred, as well as the amount of incremental distribution operating expenses that are incurred. While many of the impacts appear relatively small (on a percentage basis), they demonstrate how the magnitude of impacts depend critically on utility physical, financial, and operating characteristics.

14 SOLAR ENERGY↗

P-107A hydrogen leak meter Final report

Flow improvement, mass flow calculations, matching cell factors, and temperature control of meter for hydrogen leakage measurements in liquid propulsion systems

MEASURING APPARATUS↗

Evaluation of an Arrival Coordinator Position in a Terminal Metering Enviornment

NASA has developed an integrated arrival-management solution for terminal area precision scheduling (TAPSS). Ahuman-in-the-loop simulation investigated the performance of the components of the TAPSS system. The focus ofthis paper is set on the terminal radar approach control (TRACON) traffic management controller (TMC) and ArrivalRadar Coordinator (ARC) combined position, which played an integral part in coordinating, adjusting, and instantiatingthe arrival schedule computed by the TAPSS system. Analysis of the simulation data highlights the roleof the ARC within the described terminal metering environment, describes his planning strategies, the interactionswith his tools and coordination with controllers, and lends insights to the impact of the ARCs actions to the arrivalproblem. High levels of comfort and confidence were reported when working with the TAPSS system. Challengesposed the sequencing of unscheduled satellite arrival flights during periods of peak demand. To accommodate thoseflights into the arrival stream, the ARC had to identify sequence slots, while minimizing disruptions to the schedule.

terminal metering↗

Latest Strategic Surface Metering System and Progress Status in CLT

This presentation provides description of the field evaluation of surface metering deployed by NASA in Charlotte International Airport (CLT) that began with a more tactical decision timeline and progressively expanded toward more strategic timelines. This will include an update on the latest status of the ongoing research and lessons learned.

surface metering↗

Case Study of the Failure of two 13.8kV Control & Metering Transformers that caused significant Equipment Damage

The degradation and failure of cast-coil epoxy windings within 13.8kV control power transformers and metering potential transformers has been shown to be dangerous to both equipment and personnel, even though best industrial design practices were followed. Accident scenes will be examined for two events at a U.S. Department of Energy laboratory. Failure modes will be explained and current design practices discussed with changes suggested to prevent a recurrence and to minimize future risk. New maintenance philosophies utilizing partial discharge testing of the transformers as a prediction of end-of-life will be examined.

42 ENGINEERING↗

Metering System Assessment Guidelines

Part of a series of 34 energy efficiency checklists, data collection forms, and how-to guides, the Metering System Assessment Guidelines provides detailed assessment procedures.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

bayesian structural time series↗

Batteries in SAM 2020.2.29: Behind-the-Meter Systems

Provide an overview of behind the meter dispatch methods in the SAM 2020.2.29 software for analysis of residential, commercial, and generic battery systems. Discuss the details of SAM's automatic peak shaving and manual energy arbitrage dispatch options.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model: Preprint

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources: Preprint

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfill their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

behind-the-meter↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗