SEARCH · Engineering Papers
Results for “Mass Spectrometry”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
ClipsMS: An Algorithm for Analyzing Internal Fragments Resulting from Top-Down Mass Spectrometry
Not provided.
Improving Peptide-Level Mass Spectrometry Analysis via Double Competition
A critical statistical task in the analysis of shotgun proteomics data involves controlling the false discovery rate (FDR) among the reported set of discoveries. This task is most commonly solved at the peptide-spectrum match (PSM) level by using target-decoy competition (TDC), in which a set of observed spectra are searched against a database containing a mixture of real (target) and decoy peptides. The PSM-level procedure can be adapted to the peptide level by selecting the top-scoring PSM per peptide prior to FDR estimation. Here, we investigate both PSM-level and peptide-level FDR control methods and come to two conclusions. First, although the TDC procedure is provably correct under certain assumptions, we observe that one of these assumptions - that incorrect PSMs are independent of one another - is frequently violated. Hence, we empirically demonstrate that TDC-based PSM-level FDR estimates can be liberally biased. Further, we propose that researchers avoid PSM-level results and instead focus on peptide-level analysis. Second, we investigate three ways to carry out peptide level TDC and show that the most common method ("PSM-only") offers the lowest statistical power in practice. The most powerful method, peptide-level FDR with PSM competition ("PSM-and-peptide"), carries out competition first at the PSM level and then again at the peptide level. In our experiments, this approach yields an average increase of 17% more discovered peptides at a1% FDR threshold relative to the PSM-only method.
Curious Case of BiEDOT: MALDI-TOF Mass Spectrometry Reveals Unbalanced Monomer Incorporation with Direct (Hetero)arylation Polymerization
Explore the source record for details and available documents.
Probing Atmospheric Aerosols by Multimodal Mass Spectrometry Techniques: Revealing Aging Characteristics of Its Individual Molecular Components
Explore the source record for details and available documents.
Nitrogen Reduction Testing with Real-Time 15 NH 3 Yield Quantification Using Orbital Multiturn Time-of-Flight Mass Spectrometry
Not Available
Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry: A Strategy for Optimization, Characterization, and Quantification of Antioxidant Nitro Derivatives
Not Available
Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Analysis of Eutectic Bis(2,2-dinitropropyl) Acetal/Formal Degradation Profile: Nontargeted Identification of Antioxidant Derivatives
Not Available
Identification and Confirmation of Fentanyls on Paper using Portable Surface Enhanced Raman Spectroscopy and Paper Spray Ionization Mass Spectrometry
Not provided.
Pyrolysis Vacuum-Assisted Plasma Ionization Ion Mobility–Mass Spectrometry for Insoluble Polymer Analysis
Wire-based metal additive manufacturing utilizes the ability of additive manufacturing to fabricate complex geometries with high deposition rates (above 7 kg/h), thus finding applications in the fabrication of large-scale components, such as stamping dies. Traditionally, the workhorse materials for stamping dies have been martensitic steels. However, the complex thermal gyrations induced during additive manufacturing can cause the evolution of an inhomogeneous microstructure, which leads to a significant scatter in the mechanical properties, especially the toughness. Therefore, to understand these phenomena, arc-based additive AISI 410 samples were fabricated using robotic gas metal arc welding (GMAW) and were subjected to a detailed characterization campaign. The results show significant scatter in the tensile properties as well as Charpy V-notch impact toughness data, which was then correlated to the microstructural heterogeneity and delta (δ) ferrite formation. Post-processing (austenitizing and tempering) treatments were developed and an ~70% reduction in the scatter of tensile data and a four-times improvement in the toughness were obtained. The changes in mechanical properties were rationalized based on the microstructure evolution during additive manufacturing. Based on these, an outline to tailor the composition of “printable” steels for tooling with isotropic and uniform mechanical properties is presented and discussed.
Internal Fragments Generated from Different Top-Down Mass Spectrometry Fragmentation Methods Extend Protein Sequence Coverage
Not provided.
Fast Determination of the Lignin Monomer Compositions of Genetic Variants of Poplar via Fast Pyrolysis/Atmospheric Pressure Chemical Ionization Mass Spectrometry
Not provided.
Detection of Lipid-Bound Bacteriorhodopsin Trimer Complex Directly from Purple Membrane by Native Mass Spectrometry
Not provided.