Microsphere Templated Gallium Nitride Growth and Liftoff.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Presented by LRST at the AIChE 2020 Annual Meeting, 11/17
Explore the source record for details and available documents.
The present disclosure relates to an apparatus for electroplating an element. The apparatus may comprise a cathode cage assembly. The cathode cage assembly may include a cage member and at least one electrically conductive wire extending along at least a portion of the cage member. The wire may be arranged to form at least one volume within the cage member for retaining an element within the cage member. The cage member and the wire permit a degree of movement of the element during an electroplating process while retaining the element within the volume.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Anatase hollow sphere with mesoporosity was prepared by sol pyrogenation used TiCl{sub 4} as precursor only. The samples were characterized by X-ray diffraction and scan electron microscopy, their specific surface area was measured by N{sub 2} adsorption. The results show that the sample calcined at 500 deg. C for 2 h is phase pure anatase, the morphology of the particle of the sample is hollow sphere, and the wall of the hollow sphere is constituted of anatase nanoparticle and mesoporosity. The crystallinity, the crystal size, the pore width, the specific surface area and the crystal phase of the sample are changing along with the calcined temperature. The optical property was measured by ultraviolet radiation vis absorption spectra of the suspension of the samples. The results show that the optical property of the sample is better than that of nanoanatase particle, and the optical property of hollow sphere titania with mesoporosity is related to its crystal phase, specific surface area, crystal size, porosity size and crystallinity.
Foam delivery of remedial amendments for in-situ immobilization of deep vadose zone contaminants can overcome the intrinsic problems associated with solution-based delivery, such as preferential flow and contaminant mobilization. In this work, the feasibility of using foam to deliver nanoparticles in unsaturated porous media was investigated. Carboxyl-modified polystyrene latex microspheres were used as surrogates for nanoparticles of remediation purposes. Foams generated from the solutions of six commonly available surfactants all had excellent abilities to carry the microspheres. The presence of the microspheres did not reduce the stabilities of the foams. When microsphere-laden foam was injected through the unsaturated columns, the fractions of microspheres exiting the column were much higher than that when the microsphere water suspensions were injected through the columns. The enhanced microsphere transport implies that foam delivery could significantly increase the radius of influence of injected nanoparticles of remediation purposes. Reduced tension at air-water interfaces by the surfactant and increased driving forces imparted on the microspheres at the interfaces by the flowing foam bubbles may have both contributed to the enhanced transport. Preliminary tests also demonstrated that foam can carry significant fractions of zero valent iron nanoparticles at concentrations relevant to field remediation conditions (up to 5.3 g L-1). As such, this study demonstrates that surfactant foam is potentially a promising vehicle to deliver nanoparticles for vadose zone remediation.
Experiments were performed to study the response to shock compression of rhodamine 6G (R6G) dye encapsulated in 1.25 μm diameter silica microspheres. When R6G was encapsulated in microspheres, the emission intensity under steady-state irradiation (the brightness) was 3.4 times greater than the same dye in solution (the free dye). At least part of the brightness improvement was caused by an enhanced radiative rate. When the microspheres were embedded in poly-methylmethacrylate subjected to planar shocks in the 3–8.4 GPa range by laser-driven flyer plates, the dye emission redshifted and lost intensity. The dye emission redshift represents an instantaneous response to changes in the local density. In free dye samples, the shock-induced intensity loss had considerably slower rise times and fall times than the redshift. When dye was encapsulated in microspheres, the time dependence of the intensity loss matched the redshift almost exactly over a range of shock pressures and durations. The faster response to shock of dye in silica microspheres was explained by dye photophysics. The microsphere environment decreased the singlet state lifetime, which decreased the rise time, and it also decreased the triplet state lifetime, which decreased the fall time. Since it is much easier and more convenient to make measurements of intensity rather than spectral shift, these microspheres represent a substantial improvement in optical sensors to monitor shock compression of microstructured materials.
Yttrium-90 (Y90) microsphere therapy, a form of radiation therapy, is an increasingly popular option for care of patients with liver metastases or unresectable hepatocellular carcinoma. The therapy directly delivers Y90 microspheres via the hepatic artery to disease sites. Following delivery, a vast majority of microspheres preferentially lodge in the capillary vessels due to their embolic size and targeted trans-arterial delivery – depositing up to 90% of its energy in the first 5 mm of tissue. There have been a number of advances in tomographic imaging within both interventional radiology and nuclear medicine that has advanced therapy planning techniques. Quantitative imaging of Y90 microsphere distribution post-therapy has also seen innovations that have led to improvements in tumor dosimetry and characterization of tumor response. A review of current trends and recent innovation in Y90 microsphere therapies will be presented. Learning Objectives: To present the imaging requirements for Y90 microsphere therapy planning To explain the standard dosimetry models used in Y90 microsphere therapy planning To report on advances in imaging for therapy planning and posttherapy assessment of tumor dosimetry and response.
Yttrium-90 (Y90) microsphere therapy, a form of radiation therapy, is an increasingly popular option for care of patients with liver metastases or unresectable hepatocellular carcinoma. The therapy directly delivers Y90 microspheres via the hepatic artery to disease sites. Following delivery, a vast majority of microspheres preferentially lodge in the capillary vessels due to their embolic size and targeted trans-arterial delivery – depositing up to 90% of its energy in the first 5 mm of tissue. There have been a number of advances in tomographic imaging within both interventional radiology and nuclear medicine that has advanced therapy planning techniques. Quantitative imaging of Y90 microsphere distribution post-therapy has also seen innovations that have led to improvements in tumor dosimetry and characterization of tumor response. A review of current trends and recent innovation in Y90 microsphere therapies will be presented. Learning Objectives: To present the imaging requirements for Y90 microsphere therapy planning To explain the standard dosimetry models used in Y90 microsphere therapy planning To report on advances in imaging for therapy planning and posttherapy assessment of tumor dosimetry and response.
Graphical abstract: Uniform SrF{sub 2} and SrF{sub 2}:Ln{sup 3+} (Ln = Er, Nd, Yb, Eu, Tb) hierarchical microsphere assembled by numerous nanoplates have been successfully synthesized via a facile hydrothermal process in the presence of chelating reagent. Highlights: Black-Right-Pointing-Pointer Uniform SrF{sub 2} and SrF{sub 2}:Ln{sup 3+} (Ln = Er, Nd, Yb, Eu, Tb) hierarchical microsphere were obtained by a simple hydrothermal method. Black-Right-Pointing-Pointer The reaction time, chelating reagent and F source play important roles for the formation of hierarchical microspheres. Black-Right-Pointing-Pointer The luminescence properties of lanthanide ion-doped SrF{sub 2} hierarchical microstructures were discussed. -- Abstract: Highly uniform SrF{sub 2} and SrF{sub 2}:Ln{sup 3+} (Ln = Er, Nd, Yb, Eu, Tb) hierarchical microspheres assembled by 2D nanoplates have been successfully synthesized by a facile and friendly hydrothermal route. X-ray powder diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and photoluminescence (PL) spectra were used to characterize the samples. The experimental results indicate that reaction time and chelating reagent play a key role in forming the hierarchical microspheres. The formation mechanism was proposed based on the evolution of this morphology as a function of hydrothermal time. The near-infrared luminescence of lanthanide ions (Er, Nd, and Yb) doped SrF{sub 2} microspheres were discussed in detail. In addition, the as-obtained SrF{sub 2}:Eu{sup 3+} sample exhibits orange-red emission centered at 590 nm under excitation at 393 nm, while the SrF{sub 2}:Tb{sup 3+} exhibits a strong green emission at 540 nm. The as-synthesized SrF{sub 2}:Ln{sup 3+} luminescent microspheres might find some potential applications in areas of photoluminescence, telecommunication and laser emission.
The method relates to the fabrication of a polymer microspheres comprised of an asymmetric layer surrounding a hollow interior. The fabricated hollow microsphere is generated from a nascent hollow microsphere comprised of an inner core of core fluid surrounded by a dope layer of polymer dope, where the thickness of the dope layer is at least 10% and less than 50% of the diameter of the inner core. The nascent hollow microsphere is exposed to a gaseous environment, generating a vitrified hollow microsphere, which is subsequently immersed in a coagulation bath. Solvent exchange produces a fabricated hollow microsphere comprised of a densified outer skin surrounding a macroporous inner layer, which surrounds a hollow interior. In an embodiment, the polymer is a polyimide or a polyamide-imide, and the non-solvent in the core fluid and the coagulation bath is water. The fabricated hollow microspheres are particularly suited as solvent supports for gas separation processes.
This paper reports a simple one-step hydrothermal route for the preparation of hierarchical nanosheets-based ZnO microstructures and their application to dye-sensitized solar cells. The morphologies of the products were controlled by the dosage of the reactants. Their physical characteristics were detected by X-ray diffraction, a field-emission scanning electron microscope and a surface analyzer. It is proved that the sample of ZnO microspheres with larger surface area and stronger light-trapping capacity since the superiority of their entirely spherical structures exhibits better photoelectrochemical properties than the mixtures of ZnO microspheres and ZnO microflowers. A dye-sensitized solar cell assembled by the ZnO microspheres as photoanode shows an energy conversion efficiency of 2.94% after surface modification by tetrabutyl titanate solution at 90 {sup °}C. This result is over 1.6 times higher than the non-modified cell fabricated by the ZnO microspheres on the basis of the external improvement and the stability enhancement for the dye-sensitized ZnO photoanode. - Graphical abstract: Influences on energy conversion efficiency of the dye-sensitized solar cells assembled by decorating hierarchical nanosheets-based ZnO microstructures with tetrabutyl titanate solution at different temperatures. Display Omitted - Highlights: • Hierarchical nanosheets-based ZnO microstructures were controllably synthesized. • The ZnO microspheres show good optical and electrochemical properties. • The ZnO microspheres were modified by C{sub 16}H{sub 36}O{sub 4}Ti solution. • Remarkable increase of conversion efficiency is observed after surface modification.
Purpose: The accuracy of PET-based post-treatment dosimetry of yttrium-90 microspheres has been improving over the past decade and is now at a stage, permitting volumetric dose-outcome studies. We outline the recent advances and identify the physical limitations to the accuracy of the dose calculations. Methods: Convolution of the measured PET activity density distribution with a pre-calculated voxel-dose-kernel (VDK) is the most widely used method for dose reconstruction. Therefore, accurate knowledge of the beta+ branching ratio as well as the micro-dosimetric characteristics of electron interactions within the microsphere is essential for the computation of the dose kernel. We implement a model of the microspheres used in our clinic to calculate the modified electron energy spectrum at the microsphere’s surface and to determine the impact of self-shielding on the dose reconstruction. The three-dimensional dose distributions obtained for 10 patients treated with radio-embolization with yttrium-90 microspheres are evaluated and various DVH markers are investigated for correlation with outcome. Results: The methods for reducing the overall computation uncertainty are systematically outlined in this presentation. Since the latest experimental data on yttrium-90 beta+ branching ratio has a relative uncertainty of 1.5%, all contributing factors derived from Monte Carlo simulations must be brought to a sub 1% level. The self-shielding within the microspheres is found to be responsible for up to 6% reduction of the reconstructed dose in low-gradient regions and must be taken into account. The contribution of trace amounts of other beta+ emitters introduced during the manufacturing process is also discussed. Conclusion: The accelerating pace of clinical adoption of PET-based post-treatment dosimetry is mainly due to advances in both quantitative PET imaging and physical models of dose deposition. We show that the overall physical dose uncertainty in the convolution step can be further reduced, thus making ongoing multi-institutional dose-outcome studies even more reliable.
In an experiment, the power that sustains a plasma was extinguished, so that microspheres, which had been levitated, fell downward toward a lower electrode. At the beginning of their fall, the microspheres were self-organized with a crystalline structure. This structure was found to be preserved as the microspheres accelerated all the way to the lower electrode. Although microspheres had, in this afterglow plasma, large positive charges of 12,500 e, their interparticle repulsion was unable to significantly alter the crystalline arrangement of the microspheres, as they fell. After their impact on the lower electrode, the microspheres bounced upward, and only then was the crystalline structure lost.