Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Suppression of donor-vacancy clusters in germanium by concurrent annealing and irradiation

Diffusion of phosphorous and arsenic in germanium under in situ proton irradiation has been performed and analyzed with secondary ion mass spectrometry. Dopant profiles corresponding to proton-exposed regions exhibit a higher penetration depth and more pronounced box shape than profiles of nonexposed regions. Continuum theoretical simulations reveal that diffusion under irradiation is much less affected by inactive donor-vacancy clusters than diffusion under annealing only. The suppression of donor-vacancy clusters is caused by interstitials in supersaturation and vacancy concentrations close to thermal equilibrium. Concurrent annealing and irradiation have the potential to attain high active doping levels in Ge.

36 MATERIALS SCIENCE↗

Molecular beam deposition of Al{sub 2}O{sub 3} on p-Ge(001)/Ge{sub 0.95}Sn{sub 0.05} heterostructure and impact of a Ge-cap interfacial layer

We investigated the molecular beam deposition of Al{sub 2}O{sub 3} on Ge{sub 0.95}Sn{sub 0.05} surface with and without an ultra thin Ge cap layer in between. We first studied the atomic configuration of both Ge{sub 1-x}Sn{sub x} and Ge/Ge{sub 1-x}Sn{sub x} surfaces after deoxidation by reflection high-energy electron diffraction and resulted, respectively, in a c(4x2) and (2x1) surface reconstructions. After in situ deposition of an Al{sub 2}O{sub 3} high-{kappa} gate dielectric we evidenced using time-of-flight secondary ion mass spectroscopy analyses that Sn diffusion was at the origin of high leakage current densities in the Ge{sub 1-x}Sn{sub x}/Al{sub 2}O{sub 3} gate stack. This damage could be avoided by inserting a thin 5-nm-thick Ge cap between the oxide and the Ge{sub 1-x}Sn{sub x} layer. Finally, metal-oxide-semiconductor capacitors on the Ge capped sample showed well-behaved capacitance-voltage (C-V) characteristics with interface trap density (D{sub it}) in the range of 10{sup 12} eV{sup -1} cm{sup -2} in mid gap and higher close to the valence band edge.

36 MATERIALS SCIENCE↗

Driving vertical phase separation in a bulk-heterojunction by inserting a poly(3-hexylthiophene) layer for highly efficient organic solar cells

A desirable vertical phase separation of a bulk-heterojunction was achieved by inserting a P3HT layer between the blend layer and the poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) layer. According to the high (PEDOT:PSS) and low (P3HT) surface energies of substrate, it might be possible to modulate the vertical phase separation in the bulk-heterojunction. The result of vertical phase separation was determined using time-of-flight secondary-ion mass spectroscopy analysis. A controlled thickness of 50 nm for the inserted P3HT layer prevented undesirable light absorption and the power conversion efficiency of this condition was increased by 44% compared to that of a reference device.

36 MATERIALS SCIENCE↗

Identification of peptide-binding sites within BSA using rapid, laser-induced covalent cross-linking combined with high-performance mass spectrometry

In this paper, we are developing a rapid, time-resolved method using laser-activated cross-linking to capture protein-peptide interactions as a means to interrogate the interaction of serum proteins as delivery systems for peptides and other molecules. A model system was established to investigate the interactions between bovine serum albumin (BSA) and 2 peptides, the tridecapeptide budding-yeast mating pheromone (α-factor) and the decapeptide human gonadotropin-releasing hormone (GnRH). Cross-linking of α-factor, using a biotinylated, photoactivatable p-benzoyl-L-phenylalanine (Bpa)–modified analog, was energy-dependent and achieved within seconds of laser irradiation. Protein blotting with an avidin probe was used to detect biotinylated species in the BSA-peptide complex. The cross-linked complex was trypsinized and then interrogated with nano-LC–MS/MS to identify the peptide cross-links. Cross-linking was greatly facilitated by Bpa in the peptide, but some cross-linking occurred at higher laser powers and high concentrations of a non-Bpa–modified α-factor. This was supported by experiments using GnRH, a peptide with sequence homology to α-factor, which was likewise found to be cross-linked to BSA by laser irradiation. Analysis of peptides in the mass spectra showed that the binding site for both α-factor and GnRH was in the BSA pocket defined previously as the site for fatty acid binding. This model system validates the use of laser-activation to facilitate cross-linking of Bpa-containing molecules to proteins. Finally, the rapid cross-linking procedure and high performance of MS/MS to identify cross-links provides a method to interrogate protein-peptide interactions in a living cell in a time-resolved manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, methane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.

Niemann, H.↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of mlz from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.

Niemann, Hasso↗

Optical and mass-spectral characterization of mixed-gas flowing atmospheric-pressure afterglow sources

Plasma-based ambient desorption/ionization (ADI) sources for mass spectrometry (MS) often use helium as the primary discharge gas due to the large reaction cross section of excited helium species with atmospheric gases, which ultimately leads to efficient reagent-ion formation. However, some studies have shown that mixed-gas plasmas provide unique advantages. For instance, our group showed that a helium-oxygen flowing atmospheric-pressure afterglow (He:O 2 -FAPA) source yielded enhanced ion signals for small polar analytes, but compounds with aromatic rings underwent chemical modification to produce pyrylium species. Here, it is shown that the addition of H 2 to the helium FAPA gas significantly decreased the reagent-ion signals, but analyte-ion signal was not affected to the same degree. In addition, mass spectra obtained with He:H 2 -FAPA were chemically cleaner with fewer ions stemming from analyte species and produced less oxidation of analytes. Addition of nitrogen increased the abundance of negative reagent ions (e.g., NO 2 - and NO 3 - ) which led to enhanced ion signal for RDX. To better understand these unique advantages of a mixed-gas FAPA, the impact of molecular-gas (O 2 , N 2 , or H 2 ) addition on the optical-emission spectra from the discharge was also measured. Spatially resolved emission was obtained from the anode- and negative-glow regions. In general, addition of small fractions (~0.1%) of molecular gases decreased helium and OH emission intensities. Atomic oxygen and hydrogen emission increased with the addition of O 2 and H 2 , respectively. Furthermore, emission characteristics of N 2 , N 2 + , and NO with respect to molecular gas composition on He-FAPA were measured. Finally, fundamental plasma parameters, such as OH rotational temperature (T rot ), were also calculated for these mixed-gas systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface segregation effects of erbium in GaAs growth and their implications for optical devices containing ErAs nanostructures

We report on the integration of semimetallic ErAs nanoparticles with high optical quality GaAs-based semiconductors, grown by molecular beam epitaxy. Secondary ion mass spectrometry and photoluminescence measurements provide evidence of surface segregation and incorporation of erbium into layers grown with the erbium cell hot, despite the closed erbium source shutter. We establish the existence of a critical areal density of the surface erbium layer, below which the formation of ErAs precipitates is suppressed. Based upon these findings, we demonstrate a method for overgrowing ErAs nanoparticles with III-V layers of high optical quality, using subsurface ErAs nanoparticles as a sink to deplete the surface erbium concentration. This approach provides a path toward realizing optical devices based on plasmonic effects in an epitaxially-compatible semimetal/semiconductor system.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The use of gas chromatography – high resolution mass spectrometry for suspect screening and non-targeted analysis of per- and polyfluoroalkyl substances

This study is a workflow development for the analysis, identification, and categorization of per- and polyfluoroalkyl substances (PFAS) using gas chromatography-high resolution mass spectrometry (GC-HRMS) with non-targeted analysis (NTA) and suspect screening techniques. The behavior of various PFAS in a GC-HRMS was studied with regards to retention indices, ionization susceptibility, fragmentation patterns, etc. A custom PFAS database was constructed from 141 diverse PFAS. The database contains mass spectra from electron ionization (EI) mode, as well as MS and MS/MS spectra from positive and negative chemical ionization (PCI and NCI, respectively) modes. Common fragments of PFAS were identified across a diverse set of 141 PFAS analyzed. A workflow for suspect screening of PFAS and partially fluorinated products of incomplete combustion/destruction (PICs/PIDs) was developed which utilized both the custom PFAS database and external databases. PFAS and other fluorinated compounds were identified in both a challenge sample (designed to test the identification workflow) and incineration samples suspected to contain PFAS and fluorinated PICs/PIDs. The challenge sample resulted in a 100% true positive rate (TPR) for PFAS which were present in the custom PFAS database. In conclusion, several fluorinated species were tentatively identified in the incineration samples using the developed workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UCB-GLOBES: An open-access mass spectral database of identified and unidentified atmospheric organic compounds

Chemical characterization of atmospheric organic aerosols using gas chromatography with 70 eV electron ionization mass spectrometry (GC/EI-MS) has been used for decades in advancing molecular marker detection and identification, though primarily through suspect screening and/or targeted analyses. To advance non-targeted analyses of environmental samples, we have catalogued approximately 27 000 mass spectra (MS) of the trimethylsilyl derivatives of semi-volatile organic aerosol (OA) analytes in the open-access University of California Berkeley Goldstein Library of Organic Biogenic Environmental Spectra (UCB-GLOBES). Analytes were observed in ambient samples from the U.S. and the Central Amazon and/or laboratory simulations of secondary OA (SOA) formation. These samples are representative of OA under urban and biomass burning influences as well as SOA derived from biogenic precursors (e.g., isoprene, monoterpenes, sesquiterpenes) and biomass burning intermediates. MS are documented in UCB-GLOBES without regard to known chemical identity, annotated with extensive metadata such as sample source/experimental conditions, any structural information gained from MS analyses, and predicted chemical properties such as average carbon oxidation state and carbon number. UCB-GLOBES MS are compatible for importing into the NIST MS Search program, and we have also provided a Jupyter Notebook for MS visualization and comparisons. We demonstrate the utility of UCB-GLOBES through MS reanalyses of prior analytes observed in ambient data, finding a 20 % reduction in the number of analytes assigned to OA source categories reliant solely on time series correlation and an overall 11 % increase in new MS-based OA source categorization for the Southeast U.S. For 1513 analytes observed previously in the Central Amazon, we found 375 MS matches using UCB-GLOBES vs. 136 MS matches during prior analyses, representing a 14 % gain in newly confirmed or newly categorized OA species. While OA from laboratory oxidation experiments in UCB-GLOBES are highly diverse chemically, on average only 29 % of UCB-GLOBES MS have a mass spectral match to another MS entry in UCB-GLOBES and/or in databases of known compounds (i.e. NIST MS Database, Adams Essential Oil, MANE Flavor and Fragrance Company). This indicates that roughly 70 % of UCB-GLOBES MS are unique thus far, not observed more than once among the laboratory oxidation samples and ambient data in UCB-GLOBES MS. Further, only 18 % can be positively identified using these databases or known authentic standards. This points to a large gap between these laboratory simulations and ambient OA. Overall, the UCB-GLOBES database can be utilized for improving confidence in OA source categorization and/or identification, novel chemical marker discovery, tracking chemical diversity, de novo structure and properties prediction, and improving MS search and matching algorithms. This can ultimately inform future research priorities for the chemical characterization of atmospheric organic samples.

Mass spectrometry↗

Role of stable and metastable Mg-H complexes in p-type GaN for cw blue laser diodes

Secondary ion mass spectroscopy (SIMS) and capacitance-voltage measurements were combined to thoroughly study Mg doping in GaN layers grown by metal organic vapor phase epitaxy. First we found that the Mg steady-state incorporation regime occurs for a surface coverage of 0.3 monolayer. Additionally SIMS indicates that H incorporates proportionally with Mg until a certain [Mg] where [H] saturates. After thermal activation, [H] while being much lower still scales with [Mg]. These results suggest that H combines with Mg to form two different types of Mg-H complexes: a metastable one leading to the Mg acceptor after annealing, the other one (dominating at high [Mg]) being stable and electrically inactive. The obtained results allowed us optimizing doping conditions for blue laser diodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reactions of Propyl Radicals: A Shock Tube - VUV Photoionization Mass Spectrometry Study

The pyrolytic reactions of n-propyl and i-propyl radicals and their precursors have been investigated at elevated temperatures and pressures (600 – 900 K and 5 – 8 bar). The studies were performed in a miniature high repetition rate shock tube with synchrotron vacuum ultraviolet photoionization mass spectrometry yielding comprehensive datasets of temporal and photoionization energy dependencies of reagents and products. The propyl radicals were generated by pyrolysis of alkyl nitrites. In addition to the main decomposition path, NO elimination, the mass spectra allowed an alternative minor path via HNO elimination to be identified and quantified. For the n-propyl precursor the HNO elimination route accounted for 9% of the alkyl nitrite while for the i-propyl precursor it was 2.5%. These values are in good agreement with a recent study on i-butyl radicals in the same apparatus at similar conditions. The ratio of disproportionation/recombination was obtained for n- propyl from the relative concentrations of n-hexane and propene and for i-propyl from 2,3-dimethyl butane and propene. For n-propyl the ratio is 0.3 and 1.2 for i-propyl, both are independent of temperature and pressure over the experimental range. The disproportionation/recombination ratios are about a factor of 2 higher than prior evaluations that are based mainly on room temperature data. The experimental results are some of the first from the apparatus used and comments are made about the technique, challenges encountered, and suggestions for future developments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for the NΔ resonance in the 𝛾𝑑 → 𝑑𝜋 +𝜋 − reaction

A dibaryon which is an object with baryon number B = 2 has been studied for a long time. Dyson and Xuong classified non-strangeness dibaryon states based on SU(6) symmetries in 1960?s. In the framework, the deuteron is classified as one of the sextet states of dibaryons. Although dibaryon have been an interesting subject of research for a long time, most of the experimental studies up to the early 2000?s were unsuccessful. The CELCIUS/WASA collaboration reported this state via the double-pionic fusion reaction (?= ! 3c0c0) in 2009. Thereafter, the WASA-at-COSY collaboration revealed properties of the isoscaler resonance state via the ?= ! 3c0c0 reaction in 2011. The dibaryon resonance state with isospin ? = 0 and spin ( = 3 thought to be a ?03 which was predicted by Dyson and Xuong at 2.35 GeV?22 with a configuration of ??. The reported mass and width of that state were 2?37 GeV?22 and 0?07 GeV?22, espectively. The mass was ?0?08 GeV?22 smaller than that of 2?, the width was narrower than that of single ?. This surprising result made dibaryon study come back into the limelight. ?12 is one of the dibaryon states classified by Dyson and Xuong with isospin ? = 1, spin ( = 2. This state can be regarded as an s-wave #? resonance. ?12 is an interesting state from the point of view of the possibilities of existence as an internal structure of ?03 and contribution to many-body effects in nuclei. Though there were some experimental clues and theoretical studies of this state, it was unclear whether the obtained experimental results represented a real resonance or not due to the difficulty of separation from kinematical effects. Very recently, the FOREST group at Tohoku University reported a photoproduced isovector dibaryon state at mass of 2.14 GeV?22 in the 3c0 invariant mass spectra of the W3 ! 3c0c0 reaction. The most probable ?% configuration was 2¸ although they didn?t exclude the possibility of ?% = 1¸ or 3?. They separated the dibaryon production process from conventional pion production process for the first time using angular distribution of deuteron. We investigated the W3 ! 3c¸c? reaction for study of a possible #? dibaryon state using a deuterium target at the Research Center for Electron Photon Science, Tohoku University, Japan. In the experiment, ?3 ? 1012 tagged photon beam at energies ranging from 0.8 to 1.1 GeV was impinged to the liquid deuterium target (?520 mg?cm2) and the charged particles in the final state: deuteron, c¸, and c?, were detected by a magnetic spectrometer with a large solid angle named NKS2. NKS2 had capabilities of reconstructing momentum of charged particles, multi-track analysis, and ??c separation. We performed two different analyses named 2-track analysis and 3-track analysis. The 2-track (3-track) analysis was for events in which two (three) particles of 3c¸c? in the final state, including deuteron, were detected by NKS2. In the 3-track and 2-track analysis, ?2000? ?15000 events were identified as the W3 ! 3c¸c? reaction events, respectively. The 2-track analysis with higher statistics was mainly used to derive the cross sections, and the 3-track analysis was used to check the consistency of the 2-track analysis. In this thesis, we have shown the total cross section, the differential cross sections of the W3 ! 3c¸c? reaction in the region of jC j ¡ 0?15 GeV2. This is the world?s first measurement of this reaction in this energy region. Dibaryon resonance structures were observed below the #? threshold in the differential cross section of the invariant mass of 3c?. The mass and width of the structure were consistent with these of ?12 measured by the W3 ! 3c0c0 reaction. The mechanism of the production process was discussed based on the angular distribution of emitted deuteron.

Toyama, Yuichi↗

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

DIRECT DETECTION OF COMPLEX ORGANIC PRODUCTS IN ULTRAVIOLET (Lyα) AND ELECTRON-IRRADIATED ASTROPHYSICAL AND COMETARY ICE ANALOGS USING TWO-STEP LASER ABLATION AND IONIZATION MASS SPECTROMETRY

As discovery of complex molecules and ions in our solar system and the interstellar medium has proliferated, several groups have turned to laboratory experiments in an effort to simulate and understand these chemical processes. So far only infrared (IR) and ultraviolet (UV) spectroscopy has been able to directly probe these reactions in ices in their native, low-temperature states. Here we report for the first time results using a complementary technique that harnesses two-step two-color laser ablation and ionization to measure mass spectra of energetically processed astrophysical and cometary ice analogs directly without warming the ices—a method for hands-off in situ ice analysis. Electron bombardment and UV irradiation of H{sub 2}O, CH{sub 3}OH, and NH{sub 3} ices at 5 K and 70 K led to complex irradiation products, including HCO, CH{sub 3}CO, formamide, acetamide, methyl formate, and HCN. Many of these species, whose assignment was also strengthened by isotope labeling studies and correlate with IR-based spectroscopic studies of similar irradiated ices, are important ingredients for the building blocks of life. Some of them have been detected previously via astronomical observations in the interstellar medium and in cometary comae. Other species such as CH{sub 3}CO (acetyl) are yet to be detected in astrophysical ices or interstellar medium. Our studies suggest that electron and UV photon processing of astrophysical ice analogs leads to extensive chemistry even in the coldest reaches of space, and lend support to the theory of comet-impact-induced delivery of complex organics to the inner solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

A review on recent machine learning applications for imaging mass spectrometry studies

Imaging mass spectrometry (IMS) is a powerful analytical technique widely used in biology, chemistry, and materials science fields that continue to expand. IMS provides a qualitative compositional analysis and spatial mapping with high chemical specificity. The spatial mapping information can be 2D or 3D depending on the analysis technique employed. Due to the combination of complex mass spectra coupled with spatial information, large high-dimensional datasets (hyperspectral) are often produced. Therefore, the use of automated computational methods for an exploratory analysis is highly beneficial. The fast-paced development of artificial intelligence (AI) and machine learning (ML) tools has received significant attention in recent years. These tools, in principle, can enable the unification of data collection and analysis into a single pipeline to make sampling and analysis decisions on the go. There are various ML approaches that have been applied to IMS data over the last decade. Here, in this review, we discuss recent examples of the common unsupervised (principal component analysis, non-negative matrix factorization, k-means clustering, uniform manifold approximation and projection), supervised (random forest, logistic regression, XGboost, support vector machine), and other methods applied to various IMS datasets in the past five years. The information from this review will be useful for specialists from both IMS and ML fields since it summarizes current and representative studies of computational ML-based exploratory methods for IMS.

47 OTHER INSTRUMENTATION↗

Identification and quantification of lignin monomers and oligomers from reductive catalytic fractionation of pine wood with GC × GC – FID/MS

Thorough lignin characterization is vital to understand the physicochemical properties of lignin and to evaluate lignocellulose biorefinery processes. In this study, an in-depth characterization of lignin oil, obtained from reductive catalytic fractionation (RCF) of pine wood, was performed with quantitative GC × GC – FID analysis and qualitative GC × GC – MS. By utilizing high-temperature resistant column sets in the GC × GC system and by applying a derivatization step, unambiguous detection of lignin monomers, dimers, and trimers is enabled. In addition to confirm the identity of eleven monomers, corresponding to 34 wt% of the RCF lignin oil, thirty-six dimers (16 wt%) and twenty-one trimers (7 wt%) were comprehensively identified by analysis of their mass spectra and quantified by a FID, encompassing the identity of an additional 23 wt% of the RCF lignin oil. The proposed structures reveal the interlinkages present in the dimeric and trimeric oligomers, containing β-5, β-1, β–β, 5–5, and a minor fraction of β-O-4 and 4-O-5 bonds. Furthermore, aliphatic end-units in the dimeric and trimeric molecules were identified, consisting of various substituents at the C4 position, that have been previously observed in the RCF-derived lignin monomers. To reduce complexity for analysis, the RCF oil was separated into six fractions, prior to analysis. The structural motifs (inter-unit linkages and end-units) that are found in the different fractions vary significantly, such that the lignin fractions extracted in more polar solvents contained higher molecular weight fragments and more hydroxyl containing structural motifs. Additionally, the identified structures of individual dimer and trimer molecules by GC × GC align well with and further complement the recent findings from 1 H– 13 C HSQC NMR spectroscopy, demonstrating complementarity between both 2D techniques to obtain a holistic view on both the molecular structures and the distribution of bonds and end-units in RCF oil. The combination of these two techniques provides a powerful tool for future RCF and other lignin depolymerization research.

09 BIOMASS FUELS↗

Inspection of next-generation EUV resists with nano-projectile secondary ion mass spectrometry

There is a rapidly growing need for new materials for extreme ultraviolet (EUV) lithography, which incorporate high EUV absorbing elements. Hybrid resists, which are a combination of inorganic and organic moieties, are promising as they offer both high EUV sensitivity and high etch resistance. However, there is a glaring lack of methods to examine the uniformity of these important materials at the nanoscale. We examine the capabilities of nano-projectile secondary ion mass spectrometry (NP-SIMS) to investigate hybrid resists. NP-SIMS is a mass spectrometry-based technique with high lateral resolution. Using NP-SIMS, a surface is probed stochastically with a suite of individual projectiles, 10 6 to 10 7 in total, separated in time and space. Examining these individual mass spectra allows for nanoscale investigation of the uniformity of the surface. We evaluated the performance of NP-SIMS using samples of poly(methyl methacrylate) (PMMA) infiltrated with varying amounts of InO x via vapor-phase infiltration (VPI), an organic–inorganic hybridization method derived from atomic layer deposition. Here, we found that NP-SIMS measurements contained abundant characteristic ions related to both the PMMA and infiltrated In. The intensity of In atomic ions increased linearly with the number of infiltration cycles; however, the uniformity of In and PMMA varied with the number of infiltration cycles. After one cycle, we found that both the PMMA and In were relatively inhomogeneous. The homogeneity improved with subsequent infiltration cycles. In addition, NP-SIMS measurements contained characteristic ions related to the infiltration reaction and provided insights into the VPI mechanism. Overall, the results show that NP-SIMS is capable of examining both the inorganic and organic moieties in a hybrid resist and will be an important method for understanding the performance of these materials for use in EUV lithography.

36 MATERIALS SCIENCE↗