Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Aliphatic Amines from Waste Polyolefins by Tandem Pyrolysis, Hydroformylation, and Reductive Amination

Pyrolysis of waste plastics can produce a product mixture with a high concentration of olefins (>50 wt%). The olefins, as building blocks in the petroleum industry, are potential precursors for valuable commodity chemicals with higher values (>$2000 per ton). In this work, we produce aldehydes by hydroformylation of the olefins present in pyrolysis oil from colored post-consumer recycled high-density polyethylene (PCR-HDPE). The obtained aldehydes in the oil are then converted into aliphatic amines via reductive amination with a Ru/C catalyst. The aminated oil was characterized by multiple analytical chemistry techniques including elemental analysis, nuclear magnetic resonance spectroscopy, high-resolution liquid chromatography-mass spectrometry, and gas chromatography-mass spectrometry with a Polyarc flame ionization detector. The concentration of metals in the PCR-HDPE and oil changes during the tandem processes, showing limited effects of these elements (e.g., Al, Ca, Fe, Mg, Ti, Zn) on hydroformylation and reductive amination. Additionally, we demonstrated that reductive amination of aldehydes with varied carbon numbers and branching properties can be achieved in the presence of a complex mixture, including paraffins and aromatics. The results indicate that waste plastics have the potential to serve as a renewable source for mono and di aliphatic amines, thereby diminishing reliance on fossil feedstocks as the current primary amine source.

aliphatic amines↗

The Mariner Jupiter/Uranus 1979 mission

Some results of recent planning studies for a Mariner Jupiter/Uranus 1979 (MJU 79) mission are discussed. It is noted that a 1979 launch will provide unique approach geometries to Uranus because, when viewed from an approaching spacecraft in 1985, the pole-on orientation of the planet and its satellite orbit tracks will seem to describe a target, permitting a long observational period of almost all the lighted hemispheres of Uranus and its five known satellites. The overall scientific objectives for a MJU 79 mission are outlined, and mission considerations are discussed, including energy requirements, use of a Jupiter gravity-assist to reduce flight-time and launch vehicle-capability requirements, and various dual-launch strategies. Basic trajectories for Jupiter and Uranus encounters are considered, and general characteristics of the MJU 79 spacecraft are described. Expected scientific returns from a typical Uranus encounter is examined, including high-resolution scanning of the planet and its satellites, more accurate estimates of satellite radii and masses, and high-resolution IR studies of the planet.

Hyde, J. R.↗

Measurement of the Higgs boson mass with H → γγ decays in 140 fb –1 of $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

The mass of the Higgs boson is measured in the H→γγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in proton–proton collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fb –1 . The measured value of the Higgs boson mass is 125.17 ± 0.11(stat.) ± 0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22 ± 0.11(stat.) ± 0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative performance of double-focus and quadrupole mass spectrometers

Light-weight flight type double focus and quadruple mass spectrometer models were compared. Data cover size, weight, and power sensitivity required to achieve same resolution sensitivity at given mass number. Comparison was made using mathematical relationships. Analysis was confined to equal ion source area sensitivity variations not more than 40% over mass range.

Wilson, S. K.↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in mass spectrometry-enabled multiomics at single-cell resolution

We report biological organisms are multifaceted, intricate systems where slight perturbations can result in extensive changes in gene expression, protein abundance and/or activity, and metabolic flux. These changes occur at different timescales, spatially across cells of heterogeneous origins, and within single-cells. Hence, multimodal measurements at the smallest biological scales are necessary to capture dynamic changes in heterogeneous biological systems. Of the analytical techniques used to measure biomolecules, mass spectrometry (MS) has proven to be a powerful option due to its sensitivity, robustness, and flexibility with regard to the breadth of biomolecules that can be analyzed. Recently, many studies have coupled MS to other analytical techniques with the goal of measuring multiple modalities from the same single-cell. It is with these concepts in mind that we focus this review on MS-enabled multiomic measurements at single-cell or near-single- cell resolution.

47 OTHER INSTRUMENTATION↗

The Advanced Composition Explorer

The Advanced Composition Explorer (ACE) was recently selected as one of two new Explorer-class missions to be developed for launch during the mid-1990's. ACE will observe particles of solar, interplanetary, interstellar, and galactic origins, spanning the energy range from that of the solar wind (approx. 1 keV/nucleon) to galactic cosmic ray energies (several hundred MeV/nucleon). Definitive studies will be made of the abundance of nearly all isotopes from H to Zn (1 less than or = Z less than or = 30), with exploratory isotope studies extending to Zr (Z = 40). To accomplish this, the ACE payload includes six high-resolution spectrometers, each designed to provide the optimum charge, mass, or charge-state resolution in its particular energy range, and each having a geometry factor optimized for the expected flux levels, so as to provide a collecting power a factor of 10 to 1000 times greater than previous or planned experiments. The payload also includes several instruments of standard design that will monitor solar wind and magnetic field conditions and energetic H, He, and electron fluxes. The scientific objectives, instrumentation, spacecraft, and mission approach that were defined for ACE during the Phase-A study period are summarized.

Stone, E. C.↗

Development of a mass spectrometer system for the measurement of inert gases in meteorites

The study of the inert gases in meteorites has provided many clues as to the origin and evolution of the solar system. Particularly crucial and complex are the gases krypton and xenon. To accurately measure the isotopic compositions of these gases requires a mass spectrometer of high sensitivity and resolution. A previously unused and largely untested mass spectrometer system was brought to the point where it was ready for routine sample analyses. This involved, among other things, focusing the ion beam for optimal peak shape and sensitivity, documenting the instrument's response to a series of characteristic tests such as multplier gain checks, and interfacing the instrument to a computer to run the sample analyses. Following this testing and setting up, three iron meteorite samples were to be analyzed for argon, krypton, and xenon. The three samples were shown in prior work to possibly contain primordial heavy inert gases. Although these analyses have not yet been carried out, it is anticipated that they will be completed in the near future.

Palma, R. L.↗

Evidence of an Extended Period of Aqueous Alteration on the Bennu Parent Body Revealed By I-Xe Analyses

NASA’s OSIRIS-REx mission delivered to Earth 121.6 g of regolith material from asteroid Bennu on 24th September 2023. We report multi-step laser pyrolysis xenon isotopic analysis to investigate the I-Xe system in individual particles separated from aggregate material (a mixture of small particles of undefined lithology). The high sensitivity of the RELAX mass spectrometer allows us to observe small excesses of individual isotopes and separate out different components, which may not be possible using a conventional noble gas mass spectrometer. The temperature resolution of RELAX is sufficient to seek an I-Xe isochron from step heating analysis of a sample mass <100 μg, which can contribute to our understanding of the nature and timing of aqueous alteration on Bennu’s parent body. We also aim to better estimate and understand the iodine concentration of CI chondrite-like material.

S A Crowther↗

A bubblelike coronal mass ejection flux rope in the solar wind

A resolution to the question of whether coronal mass ejections are loops or bubbles is proposed and applied to the geometrical analysis of a solar wind event detected at 1 AU by ISEE 1 and 3. The discontinuity orientations, the size determined by time of passage, and the magnetic cloud signature are fit into the topology of a flux rope loop distorted by expansion into a thick rope with comparable dimensions in both the ecliptic and meridional planes. The looped rope fills a bubblelike cavity, thus preserving both types of proposed coronal mass ejection geometries. Other interesting features of the data include an apparent separation by the rope core of bidirectionally streaming protons in the leading section from electrons in the trailing section, possible vortical flow within the magnetic cloud, and a well-defined filamentary structure behind the shock.

Crooker, N. U.↗

The Pre-He White Dwarfs in Eclipsing Binaries. I. WASP 0131+28

We report the first BV light curves and high-resolution spectra of the post-mass transfer binary star WASP 0131+28 to study the absolute properties of extremely low-mass white dwarfs. From the observed spectra, the double-lined radial velocities were derived, and the effective temperature and rotational velocity of the brighter, more massive primary were found to be T{sub eff,1}=10,000±200 K and v{sub 1}sin i = 55 ± 10 km s{sup −1}, respectively. The combined analysis of the Transiting Exoplanet Survey Satellite (TESS) archive data and ours yielded the accurate fundamental parameters of the program target. The masses were derived to about 1.0% accuracy and the radii to 0.6%, or better. The secondary component's parameters of M{sub 2}=0.200±0.002 M{sub ⊙}, R{sub 2}=0.528±0.003 R{sub ⊙}, T{sub eff,2} = 11,186 ± 235 K, and L{sub 2}=3.9±0.3 L{sub ⊙} are in excellent agreement with the evolutionary sequence for a helium-core white dwarf of mass 0.203 M{sub ⊙}, and indicates that this star is halfway through the constant luminosity phase. The results presented in this article demonstrate that WASP 0131+28 is an EL CVn eclipsing binary in a thin disk, which is formed from the stable Roche-lobe overflow channel and composed of a main-sequence dwarf with a spectral type A0 and a pre-He white dwarf.

79 ASTRONOMY AND ASTROPHYSICS↗

The AGORA High-resolution Galaxy Simulations Comparison Project. III. Cosmological Zoom-in Simulation of a Milky Way–mass Halo

In this work, we present a suite of high-resolution cosmological zoom-in simulations to z = 4 of a 10 12 M⊙ halo at z = 0, obtained using seven contemporary astrophysical simulation codes (Art-I, Enzo, Ramses, Changa, Gadget-3, Gear, and Gizmo) widely used in the numerical galaxy formation community. The physics prescriptions for gas cooling and heating and star formation are the same as the ones used in our previous Assembling Galaxies of Resolved Anatomy (AGORA) disk comparison but now account for the effects of cosmological processes such as the expansion of the universe, intergalactic gas inflow, and the cosmic ultraviolet background radiation emitted by massive stars and quasars. In this work, we introduce the most careful comparison yet of galaxy formation simulations run by different code groups, together with a series of four calibration steps each of which is designed to reduce the number of tunable simulation parameters adopted in the final run. In the first two steps, we methodically calibrate the gas physics, such as cooling and heating, in simulations without star formation. In the third step, we seek agreement on the total stellar mass produced with the common star formation prescription used in the AGORA disk comparison, in stellar-feedback-free simulations. In the last calibration step, we activate stellar feedback, where each code group is asked to set the feedback prescription to as close to the most widely used one in its code community as possible, while aiming for convergence in the stellar mass at z = 4 to the values predicted by semiempirical models. After all the participating code groups successfully complete the calibration steps, we achieve a suite of cosmological simulations with similar mass assembly histories down to z = 4. With numerical accuracy that resolves the internal structure of a target halo (≲100 physical pc at z = 4), we find that the codes overall agree well with one another, e.g., in gas and stellar properties, but also show differences, e.g., in circumgalactic medium (CGM) properties. We argue that, if adequately tested in accordance with our proposed calibration steps and common parameters, high-resolution cosmological zoom-in simulations can have robust and reproducible results. New code groups are invited to join and enrich this comparison by generating equivalent models or to test the code's compatibility on their own, by adopting the common initial conditions, the common easy-to-implement physics package, and the proposed calibration steps. Further analyses of the zoom-in simulations presented here will be presented in forthcoming reports from the AGORA Collaboration, including studies of the CGM, simulations by additional codes, and results at lower redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Laser Mass Spectrometry to Art and Archaeology

REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.

Gulian, Lase Lisa E.↗

White Light Coronograph (WLC) and Ultra-Violet Coronal Spectrometer (UVCS)

The white light coronagraph (WLC) and ultraviolet coronal spectrometer (UVCS) together reveal the corona and the roots of the solar wind from 1.5 to 6 solar radii from Sun center. The WLC measures the plasma density and spatial structure of the corona and coronal mass ejections at a resolution of about 20 arcseconds. The UVCS, in combination with the WLC, measures the temperature and radial outflow speed of the coronal plasma. These instruments will detect mass ejections from active regions and high speed solar wind streams from coronal holes a few days before the source regions rotate onto the face of the Sun, thus giving a week or more of advanced warning for disturbed geomagnetic conditions at Earth.

Moore, R. L.↗

White Light Coronagraph (WLC) and Ultra-Violet Coronal Spectrometer (UVCS)

The WLC and UVS together reveal the corona and the roots of the solar wind from 1.5 to 6 solar radii from sun center. The WLC measures the plasma density and spatial structure of the corona and coronal mass ejections at a plasma density and spatial structure of the corona and coronal mass ejections at a resolution of about 20 arcsec. The UVCS in combination with the WLC measures the temperature and radial outflow speed of the coronal plasma. These instruments will detect mass ejections from active regions and high speed solar wind streams from coronal holes a few days before the source regions rotate onto the face of the Sun, thus giving a week or more of advanced warning for disturbed geomagnetic conditions at Earth.

Moore, R.↗

High-Resolution IR Absorption Spectroscopy of Polycyclic Aromatic Hydrocarbons: The Realm of Anharmonicity

We report on an experimental and theoretical investigation of the importance of anharmonicity in the 3 micrometers CH stretching region of Polycyclic Aromatic Hydrocarbon (PAH) molecules. We present mass-resolved, high-resolution spectra of the gas-phase cold ((is) approximately 4K) linear PAH molecules naphthalene, anthracene, and tetracene. The measured IR spectra show a surprisingly high number of strong vibrational bands. For naphthalene, the observed bands are well separated and limited by the rotational contour, revealing the band symmetries. Comparisons are made to the harmonic and anharmonic approaches of the widely used Gaussian software. We also present calculated spectra of these acenes using the computational program SPECTRO, providing anharmonic predictions enhanced with a Fermi-resonance treatment that utilizes intensity redistribution. We demonstrate that the anharmonicity of the investigated acenes is strong, dominated by Fermi resonances between the fundamental and double combination modes, with triple combination bands as possible candidates to resolve remaining discrepancies. The anharmonic spectra as calculated with SPECTRO lead to predictions of the main modes that fall within 0.5% of the experimental frequencies. The implications for the Aromatic Infrared Bands, specifically the 3-m band are discussed.

Astrochemistry↗

Symphony: Cosmological Zoom-in Simulation Suites over Four Decades of Host Halo Mass

Abstract We present Symphony, a compilation of 262 cosmological, cold-dark-matter-only zoom-in simulations spanning four decades of host halo mass, from 10 11 –10 15 M ⊙ . This compilation includes three existing simulation suites at the cluster and Milky Way–mass scales, and two new suites: 39 Large Magellanic Cloud-mass (10 11 M ⊙ ) and 49 strong-lens-analog (10 13 M ⊙ ) group-mass hosts. Across the entire host halo mass range, the highest-resolution regions in these simulations are resolved with a dark matter particle mass of ≈3 × 10 −7 times the host virial mass and a Plummer-equivalent gravitational softening length of ≈9 × 10 −4 times the host virial radius, on average. We measure correlations between subhalo abundance and host concentration, formation time, and maximum subhalo mass, all of which peak at the Milky Way host halo mass scale. Subhalo abundances are ≈50% higher in clusters than in lower-mass hosts at fixed sub-to-host halo mass ratios. Subhalo radial distributions are approximately self-similar as a function of host mass and are less concentrated than hosts’ underlying dark matter distributions. We compare our results to the semianalytic model Galacticus , which predicts subhalo mass functions with a higher normalization at the low-mass end and radial distributions that are slightly more concentrated than Symphony. We use UniverseMachine to model halo and subhalo star formation histories in Symphony, and we demonstrate that these predictions resolve the formation histories of the halos that host nearly all currently observable satellite galaxies in the universe. To promote open use of Symphony, data products are publicly available at http://web.stanford.edu/group/gfc/symphony .

79 ASTRONOMY AND ASTROPHYSICS↗

X-Ray Optics for the 2020s

Three factors characterize an X-ray optics technology: angular resolution, effective area per unit mass, and production cost per unit effective area. In general, these three factors are always in conflict with one another. Every telescope that has flown so far represents an astronomically useful compromise of these factors. Of three operating X-ray telescopes, Chandra has been optimized for angular resolution (0.5); Suzaku for effective area per unit mass; and both were optimized in its own way to minimize production cost. Optics for the decade of2020 requires a combination of Chandra's angular resolution and Suzaku's effective area per unit mass. In this talk I will briefly review X -ray optics fabrication techniques that have been used in the past three decades and then present my expectations for the 2020s. In particular I will propose a couple of new techniques that should be investigated for making lightweight and high resolution X-ray optics.

Zhang, William↗