Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Driving toroidally asymmetric current through the tokamak scrape-off layer. II. Magnetic field structure and spectrum

The structure of the magnetic field perturbations due to nonaxisymmetric field-aligned currents in the tokamak scrape-off layer (SOL) are analytically calculated near the X-point. Paper I [I. Joseph et al., Phys. Plasmas 16, 052510 (2009)] demonstrated that biasing divertor target plates in a toroidally asymmetric fashion can generate an appreciable toroidally asymmetric parallel current density in the SOL along the separatrix. Here, the magnetic field perturbation caused by a SOL current channel of finite width and stepwise constant amplitude at the target plate is derived. Flux expansion amplifies the magnetic perturbation near the X-point, while phase interference causes the SOL amplitude to be reduced at large toroidal mode number. Far enough from the current channel, the magnetic field can be approximated as arising from a surface current near the separatrix with differing amplitudes in the SOL and the divertor leg. The perturbation spectrum and resonant components of this field are computed analytically asymptotically close to the separatrix in magnetic flux coordinates. The size of the stochastic layer due to the applied perturbation that would result without self-consistent plasma shielding is also estimated. If enough resonant field is generated, control of the edge pressure gradient may allow stabilization of edge localized modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AUP First Pre-Series Cryo-Assembly Design Production and Test Overview

New high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) have been built and tested as part of the high-luminosity upgrade of the Large Hadron Collider (HL-LHC). These new quadrupole magnets are based on Nb3Sn superconducting technology. The US Accelerator Upgrade Project (US-AUP) is producing the Q1 and Q3 Cryo-Assemblies: a pair of ~5 m long magnet structures installed in a stainless-steel helium vessel (Cold Mass) and surrounded by cryostat shields, piping, and a vacuum vessel. In conclusion, this paper gives an overview of the design, production, and the results of the horizontal test of the first pre-series Q1/Q3 Cryo-Assembly.

43 PARTICLE ACCELERATORS↗

Self-Resonant Coil Design for High-frequency High-Power Inductive Wireless Power Transfer

In this paper, the design methodology of a high-frequency, high-power, long-distance inductive wireless power transfer (WPT) is presented. The airgap (d) of a traditional high-power (>1 kW) WPT is limited to a few hundred millimeters, which is almost 1/4th of the coil diameter, D; d ≤ D/4. In this paper, the power transfer distance is significantly increased (d ≥ 1.5D) by adopting a high-frequency magnetic design and GaN-based power electronics. The material and design of the coil and shield are investigated using FEA and tested experimentally. A high frequency 6.78 MHz wireless charging system was built to transfer 1 kW power over 3 m airgap.

Mohammad, Mostak↗

Optimizing Material Selection and Operational Conditions for XHV Systems: Lessons from AISI 1020 and 316L Comparative Studies

In this study, AISI 1020 low-carbon steel is investigated as a cost-effective alternative to SS316 stainless steel for reaching extreme high vacuum (XHV) conditions. After being baked at 400°C, a vacuum chamber made of the low-carbon steel material exhibited an outgassing rate approximately 2000 times smaller than a similar chamber made of stainless steel. Its activation energy for hydrogen diffusion (27 kJ/mol) is less than half that of stainless steel (60.3 kJ/mol), indicating more efficient hydrogen removal during bakeout. MolFlow+ simulations supported the experimental data and demonstrated the importance of system geometry optimization and minimizing stainless steel content for achieving optimal vacuum performance. AISI 1020's magnetic properties, typically considered disadvantageous for accelerator applications, could benefit spin-polarized electron sources by shielding photocathodes from stray fields while simultaneously providing improved vacuum through reduced outgassing. To optimize AISI 1020's performance in XHV systems, practical considerations include pre-baking protocols and careful system design to minimize stainless steel components.

Al-Allaq, Aiman H.↗

Operational Radiation Protection in Synchrotron Light and Free Electron Laser Facilities

The 3rd generation synchrotron radiation (SR) facilities are storage ring based facilities with many insertion devices and photon beamlines, and have low injection beam power (< few tens of watts), but extremely high stored beam power ({approx} 1 GW). The 4th generation x-ray free electron laser (FEL) facilities are based on an electron Linac with a long undulator and have high injection beam power (a few kW). Due to its electron and photon beam characteristics and modes of operation, storage ring and photon beamlines have unique safety aspects, which are the main subjects of this paper. The shielding design limits, operational modes, and beam losses are first reviewed. Shielding analysis (source terms and methodologies) and interlocked safety systems for storage ring and photon beamlines (including SR and gas bremsstrahlung) are described. Specific safety issues for storage ring top-off injection operation and FEL facilities are discussed. The operational safety program, e.g., operation authorization, commissioning, training, and radiation measurements, for SR facilities is also presented.

43 PARTICLE ACCELERATORS↗

A theory of electrical conductivity, dielectric constant, and electromagnetic interference shielding for lightweight graphene composite foams

This work was driven by the need to understand the electromagnetic interference (EMI) shielding effectiveness (SE) of light weight, flexible, and high performance graphene composite foams, but as EMI SE of a material depends on its electrical conductivity, dielectric permittivity, and magnetic permeability, the investigation of these three properties also became a priority. In this paper, we first present a continuum theory to determine these three electromagnetic properties, and then use the obtained properties to evaluate the EMI SE of the foam. A two-scale composite model is conceived to evaluate these three properties, with the large one being the skeleton-void composite and the small one being the graphene-polymer composite that serves as the skeleton of the foam. To evaluate the properties of the skeleton, the effective-medium approach is taken as the starting point. Subsequently, the effect of an imperfect interface and the contributions of electron tunneling to the interfacial conductivity and Maxwell-Wagner-Sillars polarization mechanism to the dielectric constant are also implemented. The derived skeleton properties are then utilized on the large scale to determine the three properties of the composite foam at a given porosity. Then a uniform plane electromagnetic wave is considered to evaluate the EMI SE of the foam. It is demonstrated that the electrical conductivity, dielectric constant, and EMI SE of the foam calculated from the developed theory are in general agreement with the reported experimental data of graphene/PDMS composite foams. The theory is further proven to be valid for the EMI SE of solid graphene/epoxy and solid carbon nanotube/epoxy nanocomposites. It is also shown that, among the three electromagnetic properties, electrical conductivity has the strongest influence on the EMI shielding effectiveness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ MOF Pyrolysis Construction of Hierarchical Porous Co‐Nanoparticles/Carbon Cloth Composites for Enhanced Electromagnetic Wave Shielding and Absorption

The development of high-performance electromagnetic protection materials integrating broadband absorption and effective shielding capabilities is hindered by challenges in simultaneously optimizing multiple electromagnetic properties through conventional material designs. This study pioneers a hierarchical porous Co nanoparticle/carbon cloth (Co/CC) composite via controlled annealing of a Co-MOF precursor on carbon cloth. The Co-MOF served a dual role as both magnetic source and pore-forming agent, enabling in situ generation of uniformly dispersed Co nanoparticles and creation of abundant pores/interfaces on the CC fibers during pyrolysis. This unique architecture synergistically enhanced dielectric loss (via interfacial/dipolar polarization) and magnetic loss (via natural resonance, exchange interactions, and eddy currents), significantly improving impedance matching. The hierarchical pores further functioned as integrated “absorption–reflection” units for efficient electromagnetic energy attenuation. Consequently, the Co/CC composite annealed at 800°C (Co/CC-800) achieves minimum reflection loss (−40.69 dB) and 120% effective absorption bandwidth extension (6.16 GHz) as a filler, and exhibits superior electromagnetic interference shielding effectiveness (46.66 dB) as an integrated component. Significantly, Co/CC-800 demonstrated robust photothermal and electrothermal conversion capabilities, ensuring operational stability in ice-covered and humid harsh environments. This work pioneers a pore-structure-mediated strategy to harmonize dielectric–magnetic synergy, providing a new paradigm for designing advanced multifunctional electromagnetic protection materials.

dielectric‐magnetic synergy↗

Structure and magnetic properties of Co-W clusters produced by inert gas condensation

In this article, inert-gas condensation was used to synthesize Co-W clusters. The formation, structure, and magnetic properties of the clusters were investigated. Sub-10-nm clusters were obtained, and the structures and average sizes were strongly dependent on sputtering power. At low sputtering powers, the clusters were predominantly amorphous, while, at high sputtering power, the clusters were crystalline. X ray diffraction and transmission electron microscopy revealed clusters with hcp structure at high sputtering power. The magnetic properties were dependent on the sputtering power and temperature, with the highest coercivity of 810 Oe at 10 K for high sputtering power.

36 MATERIALS SCIENCE↗

Radiation Damage Analysis of FNSF Components Using McCad and MCNP

The Fusion Energy System Studies Fusion Nuclear Science Facility (FESS-FNSF) concept represents a transitional step between ITER and a commercial fusion power plant. The FNSF is a conceptualized D-T fueled tokamak with 518 MW of fusion power that has been extensively used to explore and optimize design features. The energetic 14.1-MeV neutrons can produce significant localized heating and activations, and can cause damage to plasma-facing components, which can determine maintenance/outage scheduling needs and also impact the lifetime of the device as a whole. This study illustrates a neutronics analysis that was conducted on a 22.5-degree symmetric sector of the FNSF with the goal of understanding the neutron heating and radiation damage that can be characterized by quantifying the displacements per atom (dpa). Concurrently, this study also focused on the development of analysis capabilities by converting a three-dimensional computer-aided design model of the FNSF into MCNP6.2 input using the McCad code. Accordingly, some confirmatory results on tritium production and the tritium breeding ratio (TBR) are provided to support model validation. The results produced by MCNP6.2 simulations showed that the highest heating and damage occurred in the outboard region, which concentrated approximately 290 MW of the total nuclear heating, in contrast to 97 MW within the inboard region. These results are consistent with previous studies that employed earlier versions of the FNSF concept and different modeling approaches. Furthermore, this study also provides additional details on neutron wall loading, as well as total heating from neutrons and gammas, results which show the total heating of the device (16 sectors) is approximately 477.83 ± 0.80% MW, indicating a neutron energy multiplication factor of 1.15. Additionally, the capability to calculate hydrogen and helium production, as well as dpa, is illustrated. Finally, the neutronics effects of using alternative materials to tungsten carbide were evaluated for the vacuum vessel, low-temperature shield, and structural ring components, which showed that compounds like YH 2 , Mg(BH 4 ) 2 , and ZrH 2 could reduce the total heating on the magnet and also reduce the TBR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

One Structure, Two Elements—LuGe 2 Superconductor vs Ordinary Metallic Conductor LuSn 2 . A Case Study on How Site-Selective Germanium for Tin Atom Substitution Leads to Modulating of the Charge Distribution

The substitution of chemically similar elements in a given crystal structure is an effective way to enhance physical properties, but the understanding on such improvements is usually impeded because the substitutions are random, and the roles of the different atoms cannot be distinguished by crystallographic symmetry. Herein, we provide a detailed crystallographic analysis and property measurements for the continuous solid solutions LuGe x Sn 2–x (0 < x < 2). The results show that there is no apparent change of the global symmetry, with the end-members LuGe 2 and LuSn 2 , as well as the intermediate LuGe x Sn 2–x compositions adopting the ZrSi 2 type structure (space group Cmcm, Pearson index oC12). Yet, the refinements of the crystal structures from single-crystal X-ray diffraction data show that Ge–Sn atom substitutions are not random, but occur preferentially at the zig-zag chain. The patterned distribution of two group 14 elements leads to a significant variation in chemical bonding and charge ordering within the other structural fragment, the 2D square nets, thereby resulting in tuned electron transport. The enhancement is greater than the typical Bloch-Gruneisen model, and more akin to the parallel-resistor model. Magnetization measurements on single crystals show bulk superconductivity in all LuGe x Sn 2–x samples with shielding fractions as high as 90%. Specific heat data confirm the effect to originate from residual metallic tin in the material, indicating that Sn atom substitutions in the 2D square nets cause disruptions of the hypervalent bonding and local anisotropy, which ultimately leads to vanishing of the superconducting state in the end-member LuGe 2 . This work sheds light on how the complexity in chemical interactions by two different carbon congeners leads to changes in the physical properties and how they can be correlated with the induced charge distribution. Furthermore, these studies also provide a general approach to modulation of charge density, and thus, of emerging physical properties in other classes of intermetallic systems based on the main-group elements of groups 13 to 15.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

67 Zn Solid-State NMR Spectroscopy of {[Tp But,Me ]Zn(OH 2 )}[HOB(C 6 F 5 ) 3 ]. The Importance of the Anion [HOB(C 6 F 5 ) 3 ] -

We have utilized solid-state 67 Zn NMR spectroscopy as a means to characterize one of the few examples of water bound to mononuclear tetrahedral Zn 2 + : {[Tp But,Me ]Zn(OH 2 )}[HOB(C 6 F 5 ) 3 ]. The measured quadrupole coupling (Cq) constant is 4.3 MHz with an asymmetry parameter of ηq of 0.6. Likewise, due to the small value of Cq, anisotropic shielding also contributed to the observed 67 Zn NMR lineshape. As expected, the computed values of the magnetic resonance parameters depend critically on the nature of the anion. The predicted value of Cq for {[Tp But,Me ]Zn(OH 2 )}[HOB(C 6 F 5 ) 3 ] is -4.88 MHz. We discuss the results of these calculations in terms of the nature of the anion, the local electrostatics, and its subsequent hydrogen bonding to [Tp But,Me ]Zn(OH 2 ) + .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck intermediate results. XIX. An overview of the polarized thermal emission from Galactic dust

This paper presents an overview of the polarized sky as seen by Planck HFI at 353 GHz, which is the most sensitive Planck channel for dust polarization. We construct and analyse maps of dust polarization fraction and polarization angle at 1° resolution, taking into account noise bias and possible systematic effects. The sensitivity of the Planck HFI polarization measurements allows for the first time a mapping of Galactic dust polarized emission on large scales, including low column density regions. We find that the maximum observed dust polarization fraction is high ( p max = 19.8%), in particular in some regions of moderate hydrogen column density ( N H < 2 × 10 21 cm -2 ). The polarization fraction displays a large scatter at N H below a few 10 21 cm -2 . There is a general decrease in the dust polarization fraction with increasing column density above N H ≃ 1 × 10 21 cm -2 and in particular a sharp drop above N H ≃ 1.5 × 10 22 cm -2 . We characterize the spatial structure of the polarization angle using the angle dispersion function. We find that the polarization angle is ordered over extended areas of several square degrees, separated by filamentary structures of high angle dispersion function. These appear as interfaces where the sky projection of the magnetic field changes abruptly without variations in the column density. The polarization fraction is found to be anti-correlated with the dispersion of polarization angles. These results suggest that, at the resolution of 1&deg;, depolarization is due mainly to fluctuations in the magnetic field orientation along the line of sight, rather than to the loss of grain alignment in shielded regions. We also compare the polarization of thermal dust emission with that of synchrotron measured with Planck , low-frequency radio data, and Faraday rotation measurements toward extragalactic sources. These components bear resemblance along the Galactic plane and in some regions such as the Fan and North Polar Spur regions. The poor match observed in other regions shows, however, that dust, cosmic-ray electrons, and thermal electrons generally sample different parts of the line of sight.

79 ASTRONOMY AND ASTROPHYSICS↗

First results from the implementation of the ITER diagnostic residual gas analyzer prototype at Wendelstein 7-X

Fusion reactors and long pulse fusion experiments heavily depend on a continuous fuel cycle, which requires detailed monitoring of exhaust gases. We have used a diagnostic residual gas analyzer (DRGA) built as a prototype for ITER and integrated it on the most advanced stellarator fusion experiment, Wendelstein 7-X (W7-X). The DRGA was equipped with a sampling tube and assessed for gas time of flight sample response, effects of magnetic field on gas detection and practical aspects of use in a state of the art fusion environment. The setup was successfully commissioned and operated and was used to observe the gas composition of W7-X exhaust gases. The measured time of flight gas response was found to be in the order of a second for a 7 m sample tube. High values of magnetic field were found to affect the partial pressure readings of the DRGA and suggest that additional shielding is necessary in future experimental campaigns.

47 OTHER INSTRUMENTATION↗

ACCELERATING FUSION REACTOR NEUTRONICS MODELING BY AUTOMATIC COUPLING OF HYBRID MONTE CARLO/DETERMINISTIC TRANSPORT ON CAD GEOMETRY

Detailed radiation transport calculations are necessary for many aspects of the design of fusion energy systems (FES) such as ensuring occupational safety, assessing the activation of system components for waste disposal, and maintaining cryogenic temperatures within superconducting magnets. Hybrid Monte Carlo (MC)/deterministic techniques are necessary for this analysis because FES are large, heavily shielded, and contain streaming paths that can only be resolved with MC. The tremendous complexity of FES necessitates the use of CAD geometry for design and analysis. Previous ITER analysis has required the translation of CAD geometry to MCNP5 form in order to use the AutomateD VAriaNce reducTion Generator (ADVANTG) for hybrid MC/deterministic transport. In this work, ADVANTG was modified to support CAD geometry, allowing hybrid (MC)/deterministic transport to be done automatically and eliminating the need for this translation step. This was done by adding a new ray tracing routine to ADVANTG for CAD geometries using the Direct Accelerated Geometry Monte Carlo (DAGMC) software library. This new capability is demonstrated with a prompt dose rate calculation for an ITER computational benchmark problem using both the Consistent Adjoint Driven Importance Sampling (CADIS) method an the Forward Weighted (FW)-CADIS method. The variance reduction parameters produced by ADVANTG are shown to be the same using CAD geometry and standard MCNP5 geometry. Significant speedups were observed for both neutrons (as high as a factor of 7.1) and photons (as high as a factor of 59.6).

Biondo, Elliott D↗

Measurements of Space Radiation On, and On the Way To, Mars - Paper 123

The Mars Science Laboratory (MSL) spacecraft, with the Curiosity rover inside, was launched to Mars on November 25, 2011, and landed successfully on August 6, 2012. Curiosity's science payload includes ten science instruments, one of which is the Radiation Assessment Detector, RAD. The radiation environment in deep space is harsh, and is a limiting factor in planning future human missions. RAD's measurements of the radiation environments on Mars, and on a spacecraft during transit to Mars, are important precursors to a crewed mission. RAD is a compact instrument with a mass of just 1.56 kg. Despite its small size, RAD is capable of measuring the charged and neutral particles that make up the complex environments created by Galactic Cosmic Rays (GCRs) and Solar Energetic Particles (SEPs) as they traverse shielding materials. The space radiation environment consists of a continuous flux of GCRs, the intensity of which is modulated by solar activity. At or near times of solar maximum, the interplanetary magnetic field is relatively strong, and lower-energy GCRs are screened. At solar minimum, the field weakens with a corresponding increase in GCR fluxes. SEP events are sporadic, and are more likely to occur near solar maximum. Both GCRs and SEPs present potential health risks to astronauts, but the risks are of different types. The dose rate from GCRs is modest and cannot cause acute health effects. However serious late effects may arise; of particular concern are the largely unknown health effects of exposure to high-energy GCR heavy ions. There is no terrestrial analog for this exposure and this leads to large uncertainties in health risk estimates. In contrast, SEP events can be extremely intense and could potentially cause acute health effects, but they are also dominated by protons with energies below 100 MeV, which means that shielding is a practical and effective option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, development, and results from a charge-collector diagnostic for a toroidal electron plasma experiment

A suitable charge-collector has been designed and developed to estimate charge-content of electron plasmas in a Small Aspect Ratio Toroidal Experiment in a C-shaped trap (SMARTEX-C). The electrons are periodically injected and held in the trap with the aid of electrostatic end-fields and a toroidal magnetic field. After a preset “hold” time, the trapped charges are dumped onto a grounded collector (by gating it). As the charges flow along the magnetic field lines onto the collector, the integrated current gives the charge-content of the plasma at the instant of dump. In designing such a charge collector, several challenges peculiar to the geometry of the trap and the nature of the plasma had to be addressed. Instantaneous charge measurements synchronised with the E × B drift of the plasma, along with fast transit times of electrons to the collector (few 100 ns or less) (due to the low aspect ratio of the trap) essentially require fast gating of the collector. The resulting large capacitive transients alongside low charge content (few nC) of such plasmas further lead to increasing demands on response and sensitivity of the collector. Complete cancellation of such transients is shown to be possible, in principle, by including the return path in our measurement circuit but the “non-neutrality” of the plasma acts as a further impediment. Ultimately, appropriate shielding and measurement circuits allow us to (re)distribute the capacitance and delineate the paths of these currents, leading to effective cancellation of transients and marked improvement in sensitivity. Improved charge-collector has thus been used to successfully estimate the time evolution of total charge of the confined electron plasma in SMARTEX-C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic triggering — time-resolved characterisation of silicon strip modules in the presence of switching DC-DC converters

Modules for the ATLAS Inner Tracker (ITk) strip tracker include a DC-DC converter circuit glued directly to the silicon sensor which converts the 11 V supplied to the module to the 1.5 V required for the operation of the readout chips. The DC-DC converter unit, consisting of a copper solenoid and custom ASIC, is located directly above the silicon strip sensor and therefore needs to be shielded to protect the sensor from EMI noise created during the operation of the circuit. Despite dedicated shielding, consisting of an aluminium shield box with continuous solder seams encompassing the surface components and a copper layer in the PCB beneath it, module channels connected to sensor strips located beneath the converter circuit were found to show a noise increase. While the DC-DC converter unit causing the underlying EMI noise operates at a frequency of 2 MHz, module characterisation measurements for ITk strip tracker modules are typically performed asynchronously to the DC-DC switching and are therefore averaged over the full range of time bins with respect to the converter frequency. In order to investigate the time dependence of the noise injection relative to the DC-DC switching frequency, a dedicated setup to understand the time-resolved performance change in modules was developed. By using a magnetic field probe to measure the field leaking through the shield box and triggering on its rising edge, data taking could be synchronised with the DC-DC switching. This paper illustrates the concept and setup of such time-resolved performance measurements using magnetic triggering and presents results for the observed effects on signal and noise for ATLAS ITk strip modules from both laboratory and beam tests.

47 OTHER INSTRUMENTATION↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗