Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Porous silicon nanoparticles as biocompatible contrast agents for magnetic resonance imaging

We propose porous silicon nanoparticles (PSi NPs) with natural oxide coating as biocompatible and bioresorbable contrast agents for magnetic resonant imaging (MRI). A strong shortening of the transversal proton relaxation time (T{sub 2}) was observed for aqueous suspensions of PSi NPs, whereas the longitudinal relaxation time (T{sub 1}) changed moderately. The longitudinal and transversal relaxivities are estimated to be 0.03 and 0.4 l/(g·s), respectively, which are promising for biomedical studies. The proton relaxation is suggested to undergo via the magnetic dipole-dipole interaction with Si dangling bonds on surfaces of PSi NPs. MRI experiments with phantoms have revealed the remarkable contrasting properties of PSi NPs for medical diagnostics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clear Depiction of Inflammatory Abdominal Aortic Aneurysm with Diffusion-Weighted Magnetic Resonance Imaging

We report the case of an inflammatory abdominal aortic aneurysm incidentally detected clearly with diffusion-weighted magnetic resonance imaging (DW-MRI) during the examination of a patient with myelofibrosis with myeloid metaplasia that later converted to acute myeloid leukemia. DW-MRI revealed a hyperintense halo surrounding the abdominal aorta with aneurysmatic dilatation, establishing the diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiquantitative and Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging Measurements Predict Radiation Response in Cervix Cancer

Purpose: To evaluate semiquantitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements in predicting the response to radiotherapy in cervix cancer. Methods and Materials: Patients with cervix cancer treated radically with chemoradiotherapy had DCE-MRI at three time points: before starting treatment, after 2 weeks of radiotherapy, and in the 5th week of radiotherapy. Semiquantitative measurements obtained from the signal intensity vs. time plots included arrival time of contrast, the slope and maximum slope of contrast uptake, time for peak enhancement, and the contrast enhancement ratio (CER). Pharmacokinetic modeling with a modeled vascular input function was used for the quantitative measurements volume transfer constant (K{sup trans}), rate constant (k{sub ep}), fraction plasma volume (fPV), and the initial area under gadolinium-time curve. The correlation of these measurements at each of the three time points with radiologic tumor response was investigated. Results: Thirteen patients had a total of 38 scans. There was no correlation between the DCE-MRI measurements and the corresponding tumor volumes. A statistically significant correlation with percentage tumor regression was shown with the pretreatment DCE-MRI semiquantitative parameters of peak time (p = 0.046), slope (p = 0.025), maximum slope (p = 0.046), and CER (p = 0.025) and the quantitative parameters K{sup trans} (p = 0.043) and k{sub ep} (p = 0.022). Second and third scan measurements did not show any correlation. Conclusions: This is the first study to show that pretreatment DCE-MRI quantitative parameters predict the radiation response in cervix cancer. These measurements may allow a more meaningful comparison of DCE-MRI studies from different centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential for Differentiation of Pseudoprogression From True Tumor Progression With Dynamic Susceptibility-Weighted Contrast-Enhanced Magnetic Resonance Imaging Using Ferumoxytol vs. Gadoteridol: A Pilot Study

Purpose: We evaluated dynamic susceptibility-weighted contrast-enhanced magnetic resonance imaging (DSC-MRI) using gadoteridol in comparison to the iron oxide nanoparticle blood pool agent, ferumoxytol, in patients with glioblastoma multiforme (GBM) who received standard radiochemotherapy (RCT). Methods and Materials: Fourteen patients with GBM received standard RCT and underwent 19 MRI sessions that included DSC-MRI acquisitions with gadoteridol on Day 1 and ferumoxytol on Day 2. Relative cerebral blood volume (rCBV) values were calculated from DSC data obtained from each contrast agent. T1-weighted acquisition post-gadoteridol administration was used to identify enhancing regions. Results: In seven MRI sessions of clinically presumptive active tumor, gadoteridol-DSC showed low rCBV in three and high rCBV in four, whereas ferumoxytol-DSC showed high rCBV in all seven sessions (p = 0.002). After RCT, seven MRI sessions showed increased gadoteridol contrast enhancement on T1-weighted scans coupled with low rCBV without significant differences between contrast agents (p = 0.9). Based on post-gadoteridol T1-weighted scans, DSC-MRI, and clinical presentation, four patterns of response to RCT were observed: regression, pseudoprogression, true progression, and mixed response. Conclusion: We conclude that DSC-MRI with a blood pool agent such as ferumoxytol may provide a better monitor of tumor rCBV than DSC-MRI with gadoteridol. Lesions demonstrating increased enhancement on T1-weighted MRI coupled with low ferumoxytol rCBV are likely exhibiting pseudoprogression, whereas high rCBV with ferumoxytol is a better marker than gadoteridol for determining active tumor. These interesting pilot observations suggest that ferumoxytol may differentiate tumor progression from pseudoprogression and warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging and Spectroscopy to Assess Leg Muscle Macrostructure and Microstructure in Healthy Older Women: A Feasibility Assessment

Advanced magnetic resonance (MR) scanning techniques, such as diffusion tensor imaging (DTI) and proton MR spectroscopy ({sup 1}H-MRS) permit microstructural evaluation of water diffusivity and intramyocellular lipid content, respectively. We aimed to determine the feasibility of performing advanced MR scanning (proton density [PD] weighted imaging, DTI, and {sup 1}H-MRS) to evaluate properties of leg muscles in older women with respect to: (1) participant recruitment using three community-based strategies; (2) participant tolerance to the MRI scan acquisition protocol; and (3) scan acquisition and analyses protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detachment stabilization with n/m=1/1 resonant magnetic perturbation field applied to the stochastic magnetic boundary of the Large Helical Device

It is found that the remnant island structure created by n/m=1/1 resonant magnetic perturbation field in the stochastic magnetic boundary of the Large Helical Device (LHD) [A. Komori et al., Nucl. Fusion 49, 104015 (2009)] has a stabilizing effect on formation of radiating plasma, realizing stably sustained divertor detachment operation with the core plasma being unaffected. The data from the several diagnostics, (profiles of electron temperature and density, radiation and temporal evolution of divertor particle flux) indicate selective cooling around X-point of the island and thus peaked radiation there, which is stabilized outside of the last closed flux surface throughout the detachment phase. The vacuum ultraviolet spectroscopy measurements of high Z impurity (iron) emission shows significant decrease during the detachment, indicating core plasma decontamination. The results from the three-dimensional (3D) edge transport code, edge Monte Carlo 3D (EMC3) [Y. Feng et al., Contrib. Plasma Phys. 44, 57 (2004)]-EIRENE [D. Reiter et al., Fusion Sci. Technol. 47, 172 (2005)] show similar tendency in the radiation pattern. The island size and its radial location are varied to investigate the magnetic topology effects on the detachment control. The divertor particle flux and neutral pressure exhibit intermittent oscillation as well as modification of recycling pattern during the detachment, which are found to reflect the island structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of resonant magnetic perturbations on nonlinearly driven modes in drift-wave turbulence

In this work, we study the effects of resonant magnetic perturbations (RMPs) on turbulence, flows, and confinement in the framework of resistive drift wave turbulence. We extend the Hasegawa-Wakatani model to include RMP fields. The effect of the RMPs is to induce a linear coupling between the zonal electric field and the zonal density gradient, which drives the system to a state of electron radial force balance for large ({delta}B{sub r}/B{sub 0}). Both the vorticity flux (Reynolds stress) and particle flux are modulated. We derive an extended predator prey model which couples zonal potential and density dynamics to the evolution of turbulence intensity. This model has both turbulence drive and RMP amplitude as control parameters and predicts a novel type of transport bifurcation in the presence of RMPs. We find states that are similar to the ZF-dominated state of the standard predator-prey model, but for which the power threshold is now a function of the RMP strength. For small RMP amplitude, the energy of zonal flows decreases and the turbulence energy increases with ({delta}B{sub r}/B{sub 0}), corresponding to a damping of zonal flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of particle exhaust control during ELM suppression by resonant magnetic perturbations in DIII-D

A reduction in plasma electron density ('pump-out') during the application of resonant magnetic perturbations (RMPs) on DIII-D precedes the suppression of edge localized modes (ELMs) in discharges with low (<= 0.2) electron pedestal collisionalities. The magnitude of the density drop near the plasma pedestal can be up to 30% and as low as similar to 2% for discharges with similar applied RMP, and thus motivates further study to determine the cause of the variation. Based on an analysis of the global particle balance and measurements of the D-alpha poloidal distribution, it is shown that the wall inventory can be strongly affected by changing the average triangularity ( ) of the discharge. Specifically, particle balance in = 0.3 discharges shows that the density pump-out was substantially higher than the increase in particle exhaust to the cryo-pumps, i.e. wall pumping was apparently required. On the other hand, particle balance in = 0.5 discharges shows that the density pump-out was offset by an increase in exhaust to the cryo-pumps, i.e. wall pumping was not required. Correspondingly, the D-alpha intensity increased by similar to 50%-100% at = 0.5 during the RMP phase of the discharge when compared with theRMPphase of a = 0.3 discharge. Both of these observations imply a possible increase in the neutral particles in the scrape-off-layer. More significantly, this new result demonstrates density pump-out and ELM suppression without significant wall pumping, which is a desirable feature for long-pulse reactors with saturated walls.

Unterberg, E. A.↗

Impact of resonant magnetic perturbations on zonal flows and microturbulence

Results from a joint experimental and computational effort studying the effect of resonant magnetic perturbations (RMPs) on microturbulence levels and their connection to zonal flows in the DIII-D tokamak L-mode are presented. Beam emission spectroscopy measurements show a direct increase in density fluctuations at microturbulent scales with increasing RMP amplitude, suggesting that magnetic activity introduced by the RMP affects the regulation of microturbulence on DIII-D. This is analogous to how MHD-scale magnetic fluctuations arising from tearing modes have been observed in simulations to increase microturbulence levels in the reversed-field pinch (RFP). In the RFP, this is attributed to magnetic fluctuations eroding turbulence-limiting zonal flows; this work examines if a similar mechanism is present for DIII-D microturbulence. Gyrokinetic simulations find that the application of an RMP corresponds directly to a decrease in zonal flow levels, producing a similar increase of turbulent fluctuation levels over a range of RMP amplitudes as observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations of plasma response associated with resonant magnetic perturbation fields using perturbation method in KSTAR H-mode plasmas

Abstract The plasma response associated with the resonant magnetic perturbation (RMP) field was investigated using the small edge perturbations induced by a modulated supersonic molecular beam injection (SMBI) in KSTAR. The modulated SMBI provides a time-varying perturbation of the plasma density source in the region just inside the last closed flux surface and a modulated flow damping rate. Radial propagation of the toroidal rotation perturbation induced by SMBI from the q = 3 surface to the q = 2 surface was observed. Theoretical analysis using the general perturbed equilibrium code of the RMP intensity profiles of the RMP field is consistent with the phase profile of the toroidal rotation perturbation.

Physics↗

SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.

60 APPLIED LIFE SCIENCES↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of aspect ratio on plasma response to resonant magnetic perturbations in tokamak devices

A systematic numerical study is carried out, computing and comparing the plasma response to the resonant magnetic perturbation (RMP) field, applied for controlling edge localized modes (ELMs), in a series of tokamak plasmas with varying aspect ratio and utilizing the MARS-F code. The aspect ratio is scanned either by varying the plasma major radius at a fixed minor radius or by varying the latter while fixing the former. Both approaches yield similar results when compared in terms of quantities with proper normalizations. In general, a non-monotonic dependence of the resonant response field (normalized by the vacuum counterpart) near the plasma edge is found with varying aspect ratio, indicating that a given ELM control coil current configuration strongly favors plasmas with a certain aspect ratio. This optimal aspect ratio, on the other hand, depends on the toroidal as well as poloidal (i.e., coil phasing) spectra of the applied RMP field. The equilibrium (edge) safety factor, the plasma shape, and the plasma toroidal flow are all fixed to ensure that the effects identified here are predominantly due to the plasma aspect ratio.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revealing Molecular Mechanisms in Hierarchical Nanoporous Carbon via Nuclear Magnetic Resonance

Hierarchical nanoporous carbons (HNC) have been proven to be an effective adsorbent for the adsorption of volatile organic compounds (VOCs) and CO 2 . However, questions remain regarding the hierarchical structure regulation, the adsorption mechanisms of adsorbate uptake, and interactions within the HNC. Here, we synthesize HNC from wood, using a microwave-induced heating method incorporating K 2 CO 3 activation. Our HNC exhibit Murray's law multiscale structures, prompting a molecular-scale study of adsorbate adsorption via nuclear magnetic resonance (NMR). NMR chemical shifts are consistent with ring-current effects from the adsorbent. Our NMR technique provides a convenient way to quantitate adsorption of adsorbate in HNC. VOC vapor adsorption results show NMR chemical-shift changes with time, suggesting initial adsorption into mesopores, followed by diffusion into micropores. Schroeder's paradox is demonstrated by differences in observed shifts for adsorbed liquid vis-à-vis vapor phase in these HNC. These HNC show high CO 2 adsorption capacity, portending applications to carbon capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Readout of Oriented Triplet Excitons in Linear Acenes via Room-Temperature Electrically Detected Magnetic Resonance

In this study, optically generated molecular spin centers offer an attractive platform for room-temperature spintronic and quantum applications. The linear acene family of molecules are especially good candidates due to their efficient generation of highly polarized triplet excitons via singlet fission. However, the direct detection and manipulation of these spin centers in thin films via the electrical means desirable for ultimate microelectronic devices has proven challenging. In particular, highly oriented triplet features have previously been detected in crystalline anthracene but longer acenes reveal only doublet features in Electrically-Detected Magnetic Resonance (EDMR). In this work we present EDMR spectra of highly oriented triplet excitons in pentacene for the first time, using a host-guest style device made of tetracene and pentacene. The guest acts as an energetic trap site, permitting the isolation and detection of molecular triplets at room temperature. Modeling of these results shows that the observed resonance features correspond to triplet sublevel transitions on isolated pentacene guest molecules. Rotation of the applied field confirms the tendency of the linear acenes to self-orient with the longest molecular axis perpendicular to the device substrate. Lastly, we find the disappearance of resonant triplet features in the neat acenes is not primarily due to the effects of exciton delocalization, but a broader mechanism of spin relaxation primarily influenced by exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring the internal swelling in cementitious mortars with single-sided 1H nuclear magnetic resonance

Moisture transport into concrete and mortar surfaces strongly influences the durability of structures. Transport processes are foremost controlled by the material's porosity. Cementitious materials, such as concrete and mortars, exhibit distinct changes in pore structure while drying and subsequent rewetting due to the internal shrinkage and swelling of the layered calcium-silicate hydrates. Mortars with different w/c-ratios and binders were dried and rewetted and the subsequent time dependent changes in water filled pore structure were monitored with single-sided {sup 1}H nuclear magnetic resonance. This technique combines a localized depiction of all pore water with a good time resolution. The NMR signal is split into the four pore species C-S-H interlayer water, gel pore water, interhydrate water, and capillary water by multi-exponential analysis. Two consecutive running processes in the swelling of cementitious mortars were identified and discussed based on recent models of the cement microstructure as well as its implications on the sorptivity.

36 MATERIALS SCIENCE↗