Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Dione: A Pathfinder Mission for Understanding the Iono-sphere-Thermosphere Responses to Magnetospheric Forcing

Dione is a NASA small satellite prototype for future constellations that in different configurations will provide global and localized measurements of Ionosphere-Thermosphere responses to Magnetospheric energy input in a variety of scales, enabling their better forecast and prediction. This is done with a comprehensive sensor package which includes four instruments: a miniaturized fluxgate magnetometer providing magnetic field measurements with two sensor heads, an ion sensor that measures vector plasma drifts and deduce the in-situ electric fields, an electrostatic analyzer that measures precipitating electrons and up-going secondary electrons, and a neutral mass spectrometer measuring total neutral density and composition. Dione is 3-axis stabilized in a circular low-earth (400-600 km), high-inclination orbit, traversing the auroral precipitation and high latitude currents in every orbit. This paper focuses on the mission-level architecture, but provides contextual information on the science objectives, instruments, and space-craft.

Jaime Esper↗

The Advanced Composition Explorer

The Advanced Composition Explorer (ACE) was recently selected as one of two new Explorer-class missions to be developed for launch during the mid-1990's. ACE will observe particles of solar, interplanetary, interstellar, and galactic origins, spanning the energy range from that of the solar wind (approx. 1 keV/nucleon) to galactic cosmic ray energies (several hundred MeV/nucleon). Definitive studies will be made of the abundance of nearly all isotopes from H to Zn (1 less than or = Z less than or = 30), with exploratory isotope studies extending to Zr (Z = 40). To accomplish this, the ACE payload includes six high-resolution spectrometers, each designed to provide the optimum charge, mass, or charge-state resolution in its particular energy range, and each having a geometry factor optimized for the expected flux levels, so as to provide a collecting power a factor of 10 to 1000 times greater than previous or planned experiments. The payload also includes several instruments of standard design that will monitor solar wind and magnetic field conditions and energetic H, He, and electron fluxes. The scientific objectives, instrumentation, spacecraft, and mission approach that were defined for ACE during the Phase-A study period are summarized.

Stone, E. C.↗

Magnetometer instrument team studies for the definition phase of the outer planets grand tour

The objectives of magnetic field investigations on missions to the outer planets were defined as well as an instrumentation system, a program of studies and instrument development tasks was proposed for the mission definition phase of the Outer Planets Grand Tour project. A report on the status of this program is given. Requirements were also established for the spacecraft and the mission which would insure their compatibility with the magnetic field investigation proposed for the outer planets missions and developed figures of merit for encounter trajectories. The spacecraft-instrumentation interface and the on-board data handling system were defined in various reports by the Project Team and in the reports by the Science Steering Group. The defining program for exploring the outer planets within the more restrictive constraints of the Mariner Jupiter-Saturn project included defining a limited magnetic field investigation.

Coleman, P. J., Jr.↗

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE MAGNETIC FIELD IN THE NGC 2024 FIR 5 DENSE CORE

We used the Submillimeter Array to observe the thermal polarized dust emission from the protostellar source NGC 2024 FIR 5. The polarized emission outlines a partial hourglass morphology for the plane-of-sky component of the core magnetic field. Our data are consistent with previous BIMA maps, and the overall magnetic field geometries obtained with both instruments are similar. We resolve the main core into two components, FIR 5A and FIR 5B. A possible explanation for the asymmetrical field lies in depolarization effects due to the lack of internal heating from the FIR 5B source, which may be in a prestellar evolutionary state. The field strength was estimated to be 2.2 mG, in agreement with previous BIMA data. We discuss the influence of a nearby H II region over the field lines at scales of {approx}0.01 pc. Although the hot component is probably compressing the molecular gas where the dust core is embedded, it is unlikely that the radiation pressure exceeds the magnetic tension. Finally, a complex outflow morphology is observed in CO (3 {yields} 2) maps. Unlike previous maps, several features associated with dust condensations other than FIR 5 are detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Support and Drive System of the PETRA III APPLE Undulator

Helmholtzzentrum Berlin has built an APPLE II undulator for the storage ring PETRA III. The device has a total length of 5m and a minimum gap of 11mm. The high magnetic forces in particular in the inclined mode have been analyzed by means of finite element methods (FEM). Specific mechanic components such as flexible joints have been optimized to cope with the gap- and shift-dependent 3D-forces and a sophisticated control and drive system has been implemented. After completion of the device, detailed laser interferometer measurements for all operation modes have been performed. The data are compared to the FEM simulations.

43 PARTICLE ACCELERATORS↗

Effect of moderate magnetic annealing on the microstructure, quasi-static and viscoelastic mechanical behavior of a structural epoxy

In this study the effect of moderate magnetic fields on the microstructure of a structural epoxy system was investigated. The changes in the microstructure have been quantitatively investigated using wide angle x-ray diffraction (WAXD) and pole figure analysis. The mechanical properties (modulus, hardness and strain rate sensitivity parameter) of the epoxy system annealed in the magnetic field were probed with the aid of instrumented nanoindentation and the results are compared to the reference epoxy sample. To further examine the creep response of the magnetically annealed and reference samples, short 45 min duration creep tests were carried out. An equivalent to the macro scale creep compliance was calculated using the aforementioned nano-creep data. Using the continuous complex compliance (CCC) analysis, the phase lag angle, tan (δ), between the displacement and applied force in an oscillatory nanoindentation test was measured for both neat and magnetically annealed systems through which the effect of low magnetic fields on the viscoelastic properties of the epoxy was invoked. The comparison of the creep strain rate sensitivity parameter , A/d(0), from short term(80 ), creep tests and the creep compliance J(t) from the long term(2700 s) creep tests with the tan(δ) suggests that former parameter is a more useful comparative creep parameter than the creep compliance. The results of this investigation reveal that under low magnetic fields both the quasi-static and viscoelastic mechanical properties of the epoxy have been improved.

36 MATERIALS SCIENCE↗

The Study of Single Nb3Sn Quadrupole Coils Using a Magnetic Mirror Structure

Several 90-mm quadrupole coils made of 0.7-mm Nb{sub 3}Sn strand based on the 'Restack Rod Process' (RRP) of 108/127 design, with cored and non-cored cables and different cable insulation, were fabricated and individually tested at Fermilab using a test structure designed to provide a quadrupole magnetic field environment. The coils were instrumented with voltage taps and strain gauges to study quench performance and mechanical properties. The Nb{sub 3}Sn strand and cable parameters, the coil fabrication details, the mirror model assembly procedure and test results at temperatures of 4.5 K and 1.9 K are reported and discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and Testing of a Radial Halbach Magnetic Bearing

The NASA John H. Glenn Research Center has developed and tested a revolutionary Radial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Radial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Radial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical applications, manufacturing equipment, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Radial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability.

Eichenberg, Dennis J.↗

The inductively driven transmission line: A passively coupled device for diagnostic applications on the Z pulsed power facility

The inductively driven transmission line (IDTL) is a miniature current-carrying device that passively couples to fringe magnetic fields in the final power feed on the Z Pulsed Power Facility. The IDTL redirects a small amount of Z’s magnetic energy along a secondary path to ground, thereby enabling pulsed power diagnostics to be driven in parallel with the primary load for the first time. IDTL experiments and modeling presented here indicate that IDTLs operate non-perturbatively on Z and that they can draw in excess of 150 kA of secondary current, which is enough to drive an X-pinch backlighter. Further experiments show that IDTLs are also capable of making cleaner, higher-fidelity measurements of the current flowing in the final feed.

47 OTHER INSTRUMENTATION↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Use of Photocell Readouts in the Development of High Resolution Scintillator Systems

Photomultiplier-based scintillator spectrometers are the systems of choice for a multitude of X-ray and gamma radiation measurement applications. Despite widespread use, they have numerous shortcomings. The most serious is the relatively poor energy resolution that makes isotope identification problematic particularly in the case of trace quantities. Energy resolution in scintillator/photomultiplier tube (PMT) spectrometers is governed by a combination of the crystal intrinsic resolution that includes non-linearity effects, photomultiplier statistics, and the variability in the probability of a scintillation photon generating a photoelectron at the photocathode. It is evident that energy resolution in these systems is linked to both the physics of light generation in the scintillator, as well as the characteristics of the PMT. PMTs also present design problems especially in the case of handheld and portable instruments due to their considerable weight and volume. Additionally, PMTs require well-regulated high voltage and are vulnerable to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and show a number of examples of its use in both the Main Injector and Tevatron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic compatibility of solar electric propulsion module with spacecraft and science

An investigation has been conducted in order to assess the impact of magnetic fields generated by the propulsion module upon the scientific instrumentation of the spacecraft as proposed for the mission to comet Encke. It was found that dc magnetic fields could potentially be a threat to the magnetometer experiment, whereas ac fields could affect the plasma wave experiment instrumentation. Studies included a set of measurements, computer simulation, and mathematical analyses. Ways for achieving the compatibility of the propulsion module with science are studied and recommendations advanced.

Cowgill, R. M.↗

A COAXIAL TE011 CAVITY AND A SYSTEM TO MEASURE DC AND RF PROPERTIES OF SUPERCONDUCTORS

A coaxial niobium cavity has been designed and built where the center conductor consists of a removable sample. In addition, a system to measure properties such as magnetization, penetration depth, critical temperature and thermal conductivity on the same cylindrical sample has been designed and built. The purpose of this effort is to investigate possible correlations between DC and RF properties of superconductors. In this contribution, the design of the various components is discussed and the test results on a niobium sample obtained so far are presented.

47 OTHER INSTRUMENTATION↗

A COAXIAL TE011 CAVITY AND A SYSTEM TO MEASURE DC AND RF PROPERTIES OF SUPERCONDUCTORS

A coaxial niobium cavity has been designed and built where the center conductor consists of a removable sample. In addition, a system to measure properties such as magnetization, penetration depth, critical temperature and thermal conductivity on the same cylindrical sample has been designed and built. The purpose of this effort is to investigate possible correlations between DC and RF properties of superconductors. In this contribution, the design of the various components is discussed and the test results on a niobium sample obtained so far are presented.

47 OTHER INSTRUMENTATION↗

A COAXIAL TE011 CAVITY AND A SYSTEM TO MEASURE DC AND RF PROPERTIES OF SUPERCONDUCTORS

A coaxial niobium cavity has been designed and built where the center conductor consists of a removable sample. In addition, a system to measure properties such as magnetization, penetration depth, critical temperature and thermal conductivity on the same cylindrical sample has been designed and built. The purpose of this effort is to investigate possible correlations between DC and RF properties of superconductors. In this contribution, the design of the various components is discussed and the test results on a niobium sample obtained so far are presented.

36 MATERIALS SCIENCE↗