Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Status of Pulsed Inductive Thruster Research

The TRW Pulsed Inductive Thruster (PIT) is an electromagnetic propulsion system that can provide high thrust efficiency over a wide range of specific impulse values. In its basic form, the PIT consists of a flat spiral coil covered by a thin dielectric plate. A pulsed gas injection nozzle distributes a thin layer of gas propellant across the plate surface at the same time that a pulsed high current discharge is sent through the coil. The rising current creates a time varying magnetic field, which in turn induces a strong azimuthal electric field above the coil. The electric field ionizes the gas propellant and generates an azimuthal current flow in the resulting plasma. The current in the plasma and the current in the coil flow in opposite directions, providing a mutual repulsion that rapidly blows the ionized propellant away from the plate to provide thrust. The thrust and specific impulse can be tailored by adjusting the discharge power, pulse repetition rate, and propellant mass flow, and there is minimal if any erosion due to the electrodeless nature of the discharge. Prior single-shot experiment,; performed with a Diameter diameter version of the PIT at TRW demonstrated specific impulse values between 2,000 seconds and 8,000 seconds, with thruster efficiencies of about 52% for ammonia. This paper outlines current and planned activities to transition the single shot device into a multiple repetition rate thruster capable of supporting NASA strategic enterprise missions.

Hrbud, Ivana↗

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

Development of Eddy Current Techniques for Detection of Deep Fatigue Cracks in Multi-Layer Airframe Components

Thick, multi-layer aluminum structure has been widely used in aircraft design in critical wing splice areas. The multi-layer structure generally consists of three or four aluminum layers with different geometry and varying thickness, which are held together with fasteners. The detection of cracks under fasteners with ultrasonic techniques in subsurface layers away from the skin is impeded primarily by interlayer bonds and faying sealant condition. Further, assessment of such sealant condition is extremely challenging in terms of complexity of structure, limited access, and inspection cost. Although Eddy current techniques can be applied on in-service aircraft from the exterior of the skin without knowing sealant condition, the current eddy current techniques are not able to detect defects with wanted sensitivity. In this work a series of low frequency eddy current probes have been designed, fabricated and tested for this application. A probe design incorporating a shielded magnetic field sensor concentrically located in the interior of a drive coil has been employed to enable a localized deep diffusion of the electromagnetic field into the part under test. Due to the required low frequency inspections, probes have been testing using a variety of magnetic field sensors (pickup coil, giant magneto-resistive, anisotropic magneto-resistive, and spin-dependent tunneling). The probe designs as well as capabilities based upon a target inspection for sub-layer cracking in an airframe wing spar joint is presented.

Wincheski, Russell A.↗

Vortex dynamics induced by scanning SQUID susceptometry

In this work, we measured the local magnetic response of a niobium thin film by applying a millitesla-scale AC magnetic field using a micron-scale field coil and detecting the response with a micron-scale pickup loop in a scanning superconducting quantum interference device (SQUID) susceptometry measurement. Near the film's critical temperature, we observed a steplike nonlinear and dissipative magnetic response due to the dynamics of a small number of vortex-antivortex pairs induced in the film by the local applied AC field. We modeled the dynamics of the measurement using a combined two-dimensional London-Maxwell and time-dependent Ginzburg-Landau approach, allowing us to construct a detailed real-space picture of the vortex motion causing the observed dissipative response. This work pushes scanning SQUID susceptometry of two-dimensional superconductors beyond the regime of linear response and lays the foundation for microscopic studies of vortex dynamics and pinning in superconducting devices and more exotic materials systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Studies of high-field sections of a muon helical cooling channel with coil separation

The Helical Cooling Channel (HCC) was proposed for 6D cooling of muon beams required for muon collider and some other applications. HCC uses a continuous absorber inside superconducting magnets which produce solenoidal field superimposed with transverse helical dipole and helical gradient fields. HCC is usually divided into several sections each with progressively stronger fields, smaller aperture and shorter helix period to achieve the optimal muon cooling rate. This paper presents the design issues of the high field section of HCC with coil separation. The effect of coil spacing on the longitudinal and transverse field components is presented and its impact on the muon cooling discussed. The paper also describes methods for field corrections and their practical limits. The magnetic performance of the helical solenoid with coil separation was discussed in this work. The separation could be done in three different ways and the performances could be very different which is important and should be carefully described during the beam cooling simulations. The design that is currently being considered is the one that has the poorest magnetic performance because it presents ripples in all three components, in particular in the helical gradient which could be quite large. Moreover, the average gradient could be off, which could affect the cooling performance. This work summarized methods to tune the gradient regarding the average value and the ripple. The coil longitudinal thickness and the helix period can be used to tune G. Thinner coils tend to reduce the ripples and also bring G to its target value. However, this technique reduces dramatically the operational margin. Wider coils can also reduce the ripple (not as much as thinner coils) and also tune the gradient to its target value. Longer helix periods reduce ripple and correct the gradient to the target value.

43 PARTICLE ACCELERATORS↗

Final Design and Analysis of the Superconducting Magnets for the Material Plasma Exposure Experiment

The Material Plasma Exposure eXperiment (MPEX), which has completed its final design, is a new linear plasma device to advance the understanding of plasma-material interactions through the generation and delivery of plasmas as they are expected in future fusion reactor divertors. MPEX will be a steady-state device to study high-fluence exposures of plasma-facing materials and components. The requirements for the magnetic field at the heating stages and the target make the application of superconducting coils necessary. The final designs for the superconducting magnets have been developed using three cryostat designs with warm bore diameters of 65 cm and 156 cm. The large bores are required to for other systems such as vacuum, water cooling, and RF power. There are 19 superconducting coils in MPEX that are contained in six cryostats. Although design, fabrication, and testing for the magnets as stand-alone units are straightforward, challenges will arise during the integration of the system. Various field profiles will be used during operation. The magnetic field where the electron cyclotron heating occurs needs to operate at both 1.25 and 2.50 T. Analyses that have been performed on the final design include designing the coils and determining operating currents to meet field requirements, forces between cryostats, the effects of coil and/or cryostat movement, and quench analysis. To ensure that the magnetic field requirements are met, a plan for monitoring the magnetic field at specified locations has been developed which includes the effect of coil and/or cryostat movement.

Burkhardt, Earle↗

High Magnetic Field Processing - A Heat-Free Heat Treating Method

The High and Thermal Magnetic Processing/Electro-magnetic Acoustic Transducer (HTMP/EMAT) technology has been shown to be an enabling disruptive materials processing technology, that can achieve significant improvements in microstructure and consequently material performance beyond that achievable through conventional processing, and will lead to the next generation of advanced performance structural and functional materials. HTMP exposure increased the reaction kinetics enabling refinement of microstructural features such as finer martensite lath size, and finer, more copious, homogeneous dispersions of strengthening carbides leading to combined strength and toughness improvements in bainitic steels. When induction heating is applied in a high magnetic field environment, the induction heating coil is configured so that high intensity acoustic/ultrasonic treatment occurs naturally. The configuration results in a highly effective electromagnetic acoustical transducer (EMAT).

Electron Microscopy↗

Estimating coil features from an equilibrium

We present an explicit theoretical framework for constructing artificial modular coils for vacuum stellarator fields based solely on equilibrium properties, achieved through the formulation of a current potential defined on flux surfaces. Contours of constant Boozer toroidal angle can be directly interpreted as proxy coils, and so we demonstrate that key measures of coil complexity—particularly coil non-planarity—are strongly governed by local magnetic-field properties. This approach shows promise as predictor for more realistic coil configurations, providing both a pathway toward deeper understanding of equilibrium–coil relationships and a potential practical proxy for coil design.

Rodríguez, Eduardo [Max Planck Institute for Plasm↗

Experimental investigation of cathode spots and plasma jets behavior subjected to two kinds of axial magnetic field electrodes

In this paper, cathode spot plasma jet (CSPJ) rotation and cathode spots behavior subjected to two kinds of large diameter axial magnetic field (AMF) electrode (cup-shaped and coil-shaped) are studied and analyzed based on experiments. The influence of gap distances on the CSPJ rotational behavior is analyzed. Experimental results show that CSPJ rotational phenomena extensively exist in the vacuum interrupters, and CSPJ rotational direction is along the direction of composite magnetic field (mainly the combination of the axial and azimuthal components). For coil-shaped and cup-shaped AMF electrodes, the rotational or inclination phenomena before the current peak value are much more significant than that after current peak value (for the same arc current), which is related to the larger ratio of azimuthal magnetic field B{sub t} and AMF B{sub z} (B{sub t}/B{sub z}). With the increase of the gap distance, the AMF strength decreases, when the arc current is kept as constant, the azimuthal magnetic field is kept invariable, the ratio between azimuthal magnetic field and AMF is increased, which results in the increase of rotational effect. For cathode spots motion, compared with cup-shaped electrode, coil-shaped electrode has the inverse AMF direction. The Robson drift direction of cathode spots of coil-shaped electrode is opposite to that of cup-shaped electrode. With the increase of gap distance, the Robson angle is decreased, which is associated with the reduced AMF strength. Erosion imprints of anode and cathode are also related to the CSPJ rotational phenomena and cathode spots behavior. The noise of arc voltage in the initial arcing stage is related to the weaker AMF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metallographic autopsies of full-scale ITER prototype cable-in-conduit conductors after full testing in SULTAN: 1. The mechanical role of copper strands in a CICC

Cables made with Nb 3 Sn-based superconductor strands will provide the 13 T maximum peak magnetic field of the ITER Central Solenoid (CS) coils and they must survive up to 60,000 electromagnetic cycles. Accordingly, prototype designs of CS cable-in-conduit-conductors (CICC) were electromagnetically tested over multiple magnetic field cycles and warm-up-cool-down scenarios in the SULTAN facility at CRPP. We report here a post mortem metallographic analysis of two CS CICC prototypes which exhibited some rate of irreversible performance degradation during cycling. The standard ITER CS CICC cable design uses a combination of superconducting and Cu strands, and because the Lorentz force on the strand is proportional to the transport current in the strand, removing the copper strands (while increasing the Cu:SC ratio of the superconducting strands) was proposed as one way of reducing the strand load. In this study we compare the two alternative CICCs, with and without Cu strands, keeping in mind that the degradation after SULTAN test was lower for the CICC without Cu strands. The post mortem metallographic evaluation revealed that the overall strand transverse movement was 20% lower in the CICC without Cu strands and that the tensile filament fractures found were less, both indications of an overall reduction in high tensile strain regions. Furthermore, it was interesting to see that the Cu strands in the mixed cable design (with higher degradation) helped reduce the contact stresses on the high pressure side of the CICC, but in either case, the strain reduction mechanisms were not enough to suppress cyclic degradation. Advantages and disadvantages of each conductor design are discussed here aimed to understand the sources of the degradation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison Between MAD-IPA Thrust Stand Measurements and Performance Modeling

The high specific impulse values associated with electric propulsion (EP) that allow for higher payload fractions than conventional, chemical propulsion are achieved by the acceleration of ionized propellant (plasma) by electromagnetic body forces. The lifetime of many EP devices is limited by electrode erosion caused by direct plasma-electrode interaction, while the efficiency is often limited by, among other thruster-specific factors, the available power in space. The efficiency can be increased during higher power operation since the amount of power required to ionize the propellant is fixed and decreases as a percentage of the increased input power. Pulsed inductive plasma accelerators [1-3] are a potentially elegant solution to the problems of high power demands and electrode erosion. The former is addressed in the pulsed nature of these devices, which allows for instantaneous operation on the order of megawatts while requiring a continuous supply on the order of only kilowatts, while the latter is addressed by inductive coupling of the thruster to ionized propellant. These devices operate by rapidly (on the order of microseconds) discharging stored energy at a given pulse repetition rate through a coil creating time-varying magnetic and electric fields that cause ionization, current formation and acceleration of propellant away from the coil. While the inductive (contact-less) nature of the energy transfer from the thruster to the propellant alleviates the problem of erosion and enables the use of in-situ and storable propellants incompatible with metallic electrodes, it places high voltage demands (on the order of tens of kilovolts) on the energy storage system to achieve propellant ionization.

Hallock, Ashley K.↗

Direct evidence of the effect of a moderate external magnetic field on stimulated Raman scattering in the kinetic regime

We present results from an experiment carried out at the OMEGA-EP laser facility that investigated the effect of a perpendicular magnetic field on stimulated Raman scattering (SRS) and report the first direct measurement of magnetic mitigation of SRS. A 13-T magnetic field generated by pulsed-power coils was imposed on a gas jet plasma, and a novel three-picket interaction beam was used to explore SRS reflectivity for several plasma conditions within single shots. The time-resolved backscattered light shows that SRS was mitigated by the external 13-T magnetic field in the kinetic regime (kλ D ∼ 0.3, where k is the electron plasma wave's wavenumber and λ D is electron Debye length) and at a density of n e /n cr ∼ 0.10. On the other hand, we also measured an enhancement of SRS reflectivity at lower density (n e /n cr < 0.08). We discuss experimental results in the context of magnetohydrodynamic and particle-in-cell simulations that scan SRS dynamics for a variety of plasma conditions. While the experimental evidence of SRS mitigation validates prior work on the kinetic simulation of SRS in an external magnetic field, we also find that other mechanisms such as SRS rescatter can lead to an enhancement of measured SRS reflectivity in simulations of parameters relevant to our experiment.

Gas jet↗

Modelling of Ablatant Deposition from Electromagnetically Driven Radiative Pellets for Disruption Mitigation Studies

The Electromagnetic Particle Injector (EPI) concept is advanced through the simulation of ablatant deposition into ITER H-mode discharges with calculations showing penetration past the H-mode pedestal for a range of injection velocities and granule sizes concurrent with the requirements of disruption mitigation. As discharge stored energy increases in future fusion devices such as ITER, control and handling of disruption events becomes a critical issue. An unmitigated disruption could lead to failure of the plasma facing components resulting in financially and politically costly repairs. Methods to facilitate the quench of an unstable high current discharge are required. With the onset warning time for some ITER disruption events estimated to be less than 10 ms, a disruption mitigation system needs to be considered which operates at injection speeds greater than gaseous sound speeds. Such an actuator could then serve as a means to augment presently planned pneumatic injection systems. The EPI uses a rail gun concept whereby a radiative payload is delivered into the discharge by means of the JxB forces generated by an external current pulse, allowing for injection velocities in excess of 1 km/s. The present status of the EPI project is outlined, including the addition of boost magnetic coils. These coils augment the self-generated rail gun magnetic field and thus provide a more efficient acceleration of the payload. The coils and the holder designed to constrain them have been modelled with the ANSYS code to ensure structural integrity through the range of operational coil cu

disruption↗

A facility for X-ray diffraction in magnetic fields up to 25 T and temperatures between 15 and 295 K

A facility for X-ray diffraction has been developed at the National High Magnetic Field Laboratory. It brings diffraction capability to the 25 T Florida split coil magnet and implements temperature control in a range of 15–295 K using a cold finger helium cryostat. This instrument represents an alternative to pulsed magnetic field systems, and it exceeds the static magnetic fields currently available at synchrotron facilities. Magnetic field compatibility of an X-ray source and detectors with the sizable magnetic fringe fields emanating from the magnet constrained the design of the diffractometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetically Damped Furnace Bitter Magnet Coil 1

A magnet has been built by the National High Magnetic Field Laboratory for NASA on a cost reimbursement contract. The magnet is intended to demonstrate the technology and feasibility of building a magnet for space based crystal growth. A Bitter magnet (named after Francis Bitter, its inventor) was built consisting of four split coils electrically in series and hydraulically in parallel. The coils are housed in a steel vessel to reduce the fringe field and provide some on-axis field enhancement. The steel was nickel plated and Teflon coated to minimize interaction with the water cooling system. The magnet provides 0.14 T in a 184 mm bore with 3 kW of power.

Bird, M. D.↗