Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOSS CONE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Megavoltage planar and cone-beam imaging with low-Z targets: Dependence of image quality improvement on beam energy and patient separation

Purpose: The purpose of this study is to investigate the improvement of megavoltage planar and cone-beam CT (CBCT) image quality with the use of low atomic number (Z) external targets in the linear accelerator. Methods: In this investigation, two experimental megavoltage imaging beams were generated by using either 3.5 or 7.0 MeV electrons incident on aluminum targets installed above the level of the carousel in a linear accelerator (2100EX, Varian Medical, Inc., Palo Alto, CA). Images were acquired using an amorphous silicon detector panel. Contrast-to-noise ratio (CNR) in planar and CBCT images was measured as a function of dose and a comparison was made between the imaging beams and the standard 6 MV therapy beam. Phantoms of variable diameter were used to examine the loss of contrast due to beam hardening. Porcine imaging was conducted to examine qualitatively the advantages of the low-Z target approach in CBCT. Results: In CBCT imaging CNR increases by factors as high as 2.4 and 4.3 for the 7.0 and 3.5 MeV/Al beams, respectively, compared to images acquired with 6 MV. Similar factors of improvement are observed in planar imaging. For the imaging beams, beam hardening causes a significant loss of the contrast advantage with increasing phantom diameter; however, for the 3.5 MeV/Al beam and a phantom diameter of 25 cm, a contrast advantage remains, with increases of contrast by factors of 1.5 and 3.4 over 6 MV for bone and lung inhale regions, respectively. The spatial resolution is improved slightly in CBCT images for the imaging beams. CBCT images of a porcine cranium demonstrate qualitatively the advantages of the low-Z target approach, showing greater contrast between tissues and improved visibility of fine detail. Conclusions: The use of low-Z external targets in the linear accelerator improves megavoltage planar and CBCT image quality significantly. CNR may be increased by a factor of 4 or greater. Improvement of the spatial resolution is also apparent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EVOLUTIONARY TRACKS OF TIDALLY STIRRED DISKY DWARF GALAXIES

Using collisionless N-body simulations, we investigate the tidal evolution of late-type, rotationally supported dwarfs inside Milky Way sized host galaxies. Our study focuses on a wide variety of dwarf orbital configurations and initial structures. During the evolution, the disky dwarfs undergo strong mass loss, the stellar disks are transformed into spheroids, and rotation is replaced by random motions of the stars. Thus, the late-type progenitors are transformed into early-type dwarfs as envisioned by the tidal stirring model for the formation of dwarf spheroidal (dSph) galaxies in the Local Group. We determine the photometric properties of the dwarfs, including the total visual magnitude, the half-light radius, and the central surface brightness as they would be measured by an observer near the galactic center. Special emphasis is also placed on studying their kinematics and shapes. We demonstrate that the measured values are biased by a number of observational effects including the increasing angle of the observation cone near the orbital pericenter, the fact that away from the pericenter the tidal tails are typically oriented along the line of sight, and the fact that for most of the evolution the stellar components of the dwarfs are triaxial ellipsoids whose major axis tumbles with respect to the line of sight. Finally, we compare the measured properties of the simulated dwarfs to those of dwarf galaxies in the Local Group. The evolutionary tracks of the dwarfs in different parameter planes and the correlations between their different properties, especially the total magnitude and the surface brightness, strongly suggest that present-day dSph galaxies may have indeed formed from late-type progenitors as proposed by the tidal stirring scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable charge to spin conversion in strontium iridate thin films

Efficient charge to spin conversion is important for low-power spin logic devices. Spin and charge interconversion is commonly performed using heavy metals and topological insulators, while the field of oxides is not yet fully explored. Strontium iridate thin films were grown, where the different crystal structures form a perfect playground to understand the key factors in obtaining high charge to spin conversion efficiency (i.e.,large spin Hall angle). It was found that the semiconducting Sr 2 IrO 4 has a spin Hall angle of ~0.1 (depending on measurement technique), which is promising for a spin-orbit coupled electronic system and comparable to Pt. In contrast, the perovskite SrIrO 3 , reported to have a Dirac cone near the Fermi level, has a larger spin Hall angle of 0.3–0.4 degrees. The largest difference between the two materials is a large degree of spin-momentum locking in SrIrO 3 , comparable to known topological insulators. A simple semiclassical relationship is found where thespin Hall angle increases for higher degrees of spin-momentum locking and it also increases for lower Fermi wave vectors. Here this relationship is then able to explain the decreased spin Hall angle below 10 nm film thickness in SrIrO 3 , by relating it to the correspondingly higher carrier concentration (related to the higher Fermi wavevector). Breaking the commonly believed anticorrelation between resistivity and carrier concentration paves apathway to lower power losses due to resistance while keeping large spin Hall angles.

36 MATERIALS SCIENCE↗

Simulation of enhanced light extraction from periodic, disordered, and quasi-periodic OLED structures

Here we have developed a rigorous scattering matrix theory of light emission from periodically structured media using a Green’s function approach. We computationally simulate the spectral power inside the structure, incorporating Purcell factor enhancements, and find internal waveguiding modes and plasmonic losses. We simulate the light-outcoupling factor η out and describe how corrugations and structured media can enhance η out . We have extended our framework to describe non-periodic disordered arrays as well as aperiodic quasi-crystalline arrays. Flat organic light-emitting diodes (OLEDs) have low outcoupling with η out ~20% since most of the light is trapped in waveguided modes in higher index layers or lost to plasmonic excitations at the metal cathode. Periodically corrugated OLEDs can achieve highly enhanced η out ~65%-70% for pitch values between 1000 and 2000 nm, representing an enhancement factor >3 over planar structures. Periodic corrugations strongly diffract trapped waveguided and plasmonic modes to the emissive air cone. Disordered templates also can cause significant enhanced outcoupling with η out ~50%-55% for smaller nearest-neighbor separations of 300–400 nm. Quasi-crystalline tilings can also lead to enhancements of η out ~50%-55%. This framework can be utilized to design novel structured media that can generate high light extraction.

42 ENGINEERING↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Isolator Shock Train Response to Dual-Mode Scramjet Throttling-Like Forcing

Typical dual-mode scramjet designs employ an isolator component situated between the inlet and combustor. The isolator fluidically buffers the inlet from the combustor via the formation of a shock train, an interconnected series of shock-boundary layer interactions. The isolator is required during ramjet-engine operation and at the lower edges of the scramjet operational envelope. In an operational engine, transient behavior imposes fluidic dynamics due to attitude adjustments, combustor throttling, aberrant resonances within the combustor, etc. To accommodate these transients, the shock train adjusts on both temporal and spatial scales. Sufficiently large downstream pressure increases in the combustor play a critical role during unstart, whereby strong compression waves propagate upstream in the isolator to ultimately force the shock train out the inlet, if it cannot stabilize to the pressure increase. This critically reduces the engine mass flow rate, potentially causing a catastrophic reduction in thrust and loss of the vehicle. A nearly instantaneous unstart can, in principle, be predicted by a ratio of the normal shock pressure jump in an inviscid isolator. However, lower-magnitude perturbations, below this bound, also induce unstarts. Understanding the transient behavior inherent in unsteady isolator operation is critical to reducing safety margin in isolator length and refining engine control algorithms to improve engine performance. The Isolator Dynamics Research Lab (IDRL) is a cold-flow, direct-connect isolator facility ideal for assessing the fundamental fluid dynamics of shock trains. The internal flow of a scramjet isolator is modeled using a 2D, symmetric Mach 2.5 nozzle followed by a 695 mm long, 25.4x50.8 mm rectangular isolator test section. A blockage cone on a high-speed ball screw actuator downstream of the isolator is pulsed to simulate the throttling behavior in an operational combustor. Wall flush high-speed static pressure transducers detect the streamwise shock train within the isolator. Time delays between the onset of the throttling and the response motion of the shock train are analyzed to assess the controlling scales and parameters. From this analysis, the response time of the isolator shock train system is found to depend primarily on the isolator back pressure time-rate-of-change but quickly saturates to a maximum propagation speed along the isolator. These results inform dual-mode scramjet engine designers of the critical parameters and limits of an unstart resistant engine.

scramjet↗

Technical Note: Dose gradients and prescription isodose in orthovoltage stereotactic radiosurgery

Purpose: The purpose of this work is to examine the trade-off between prescription isodose and dose gradients in orthovoltage stereotactic radiosurgery. Methods: Point energy deposition kernels (EDKs) describing photon and electron transport were calculated using Monte Carlo methods. EDKs were generated from 10 to 250 keV, in 10 keV increments. The EDKs were converted to pencil beam kernels and used to calculate dose profiles through isocenter from a 4π isotropic delivery from all angles of circularly collimated beams. Monoenergetic beams and an orthovoltage polyenergetic spectrum were analyzed. The dose gradient index (DGI) is the ratio of the 50% prescription isodose volume to the 100% prescription isodose volume and represents a metric by which dose gradients in stereotactic radiosurgery (SRS) may be evaluated. Results: Using the 4π dose profiles calculated using pencil beam kernels, the relationship between DGI and prescription isodose was examined for circular cones ranging from 4 to 18 mm in diameter and monoenergetic photon beams with energies ranging from 20 to 250 keV. Values were found to exist for prescription isodose that optimize DGI. Conclusions: The relationship between DGI and prescription isodose was found to be dependent on both field size and energy. Examining this trade-off is an important consideration for designing optimal SRS systems.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-03: PCA Modeling of Anatomical Changes During Head and Neck Radiation Therapy

Purpose: To develop principal component analysis (PCA) models from daily cone beam CTs (CBCTs) of head and neck (H and N) patients that could be used prospectively in adaptive radiation therapy (ART). Methods: : For 7 H and N patients, Pinnacle Treatment Planning System (Philips Healthcare) was used to retrospectively deformably register daily CBCTs to the planning CT. The number N of CBCTs per treatment course ranged from 14 to 22. For each patient a PCA model was built from the deformation vector fields (DVFs), after first subtracting the mean DVF, producing N eigen-DVFs (EDVFs). It was hypothesized that EDVFs with large eigenvalues represent the major anatomical deformations during the course of treatment, and that it is feasible to relate each EDVF to a clinically meaningful systematic or random change in anatomy, such as weight loss, neck flexion, etc. Results: DVFs contained on the order of 3×87×87×58=1.3 million scalar values (3 times the number of voxels in the registered volume). The top 3 eigenvalues accounted for ∼90% of variance. Anatomical changes corresponding to an EDVF were evaluated by generating a synthetic DVF, and applying that DVF to the CT to produce a synthetic CBCT. For all patients, the EDVF for the largest eigenvalue was interpreted to model weight loss. The EDVF for other eigenvalues appeared to represented quasi-random fraction-to-fraction changes. Conclusion: The leading EDVFs from single-patient PCA models have tentatively been identified with weight loss changes during treatment. Other EDVFs are tentatively identified as quasi-random inter-fraction changes. Clean separation of systematic and random components may require further work. This work is expected to facilitate development of population-based PCA models that can be used to prospectively identify significant anatomical changes, such as weight loss, early in treatment, triggering replanning where beneficial.

60 APPLIED LIFE SCIENCES↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bone loss during simulated weightlessness - Is it glucocorticoid mediated?

Elevating the hindquarters of a rat by the tail unweights the hind limbs but maintains normal weight-bearing by the forelimbs. This maneuver leads to a decrease in bone mass and calcium content in the unweighted bones (e.g., tibia and L1 vertebra), but not in the normally weighted bones (e.g., humerus and mandible). Potentially, the stress of the maneuver, mediated by increased glucocorticoid production and secretion, could explain the decreased bone formation, rather than the skeletal unweighting per se. To test this possibility, the effects of adrenalectomy on the response of bone to the unweighting of the hind limbs of normal rats were evaluated.

Bikle, D. D.↗

Cadmium affects retinogenesis during zebrafish embryonic development

Ocular malformations are commonly observed in embryos of aquatic species after exposure to toxicants. Using zebrafish embryos as the model organism, we showed that cadmium exposure from sphere stage (4 hpf) to end of segmentation stage (24 hpf) induced microphthalmia in cadmium-treated embryos. Embryos with eye defects were then assessed for visual abilities. Cadmium-exposed embryos were behaviorally blind, showing hyperpigmentation and loss of camouflage response to light. We investigated the cellular basis of the formation of the small eyes phenotype and the induction of blindness by studying retina development and retinotectal projections. Retinal progenitors were found in cadmium-treated embryos albeit in smaller numbers. The number of retinal ganglion cells (RGC), the first class of retinal cells to differentiate during retinogenesis, was reduced, while photoreceptor cells, the last batch of retinal neurons to differentiate, were absent. Cadmium also affected the propagation of neurons in neurogenic waves. The neurons remained in the ventronasal area and failed to spread across the retina. Drastically reduced RGC axons and disrupted optic stalk showed that the optic nerves did not extend from the retina beyond the chiasm into the tectum. Our data suggested that impairment in neuronal differentiation of the retina, disruption in RGC axon formation and absence of cone photoreceptors were the causes of microphthalmia and visual impairment in cadmium-treated embryos.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-05: Water Equivalent Path Length Calculations Using Scatter-Corrected Head and Neck CBCT Images to Evaluate Patients for Adaptive Proton Therapy

Purpose: To establish a method to evaluate the dosimetric impact of anatomic changes in head and neck patients during proton therapy by using scatter-corrected cone-beam CT (CBCT) images. Methods: The water equivalent path length (WEPL) was calculated to the distal edge of PTV contours by using tomographic images available for six head and neck patients received photon therapy. The proton range variation was measured by calculating the difference between the distal WEPLs calculated with the planning CT and weekly treatment CBCT images. By performing an automatic rigid registration, six degrees-of-freedom (DOF) correction was made to the CBCT images to account for the patient setup uncertainty. For accurate WEPL calculations, an existing CBCT scatter correction algorithm, whose performance was already proven for phantom images, was calibrated for head and neck patient images. Specifically, two different image similarity measures, mutual information (MI) and mean square error (MSE), were tested for the deformable image registration (DIR) in the CBCT scatter correction algorithm. Results: The impact of weight loss was reflected in the distal WEPL differences with the aid of the automatic rigid registration reducing the influence of patient setup uncertainty on the WEPL calculation results. The WEPL difference averaged over distal area was 2.9 ± 2.9 (mm) across all fractions of six patients and its maximum, mostly found at the last available fraction, was 6.2 ± 3.4 (mm). The MSE-based DIR successfully registered each treatment CBCT image to the planning CT image. On the other hand, the MI-based DIR deformed the skin voxels in the planning CT image to the immobilization mask in the treatment CBCT image, most of which was cropped out of the planning CT image. Conclusion: The dosimetric impact of anatomic changes was evaluated by calculating the distal WEPL difference with the existing scatter-correction algorithm appropriately calibrated. Jihun Kim, Yang-Kyun Park, Gregory Sharp, and Brian Winey have received grant support from the NCI Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Effects of Setup Errors and Shape Changes on Breast Radiotherapy

Purpose: The purpose of the present study was to quantify the robustness of the dose distributions from three whole-breast radiotherapy (RT) techniques involving different levels of intensity modulation against whole patient setup inaccuracies and breast shape changes. Methods and Materials: For 19 patients (one computed tomography scan and five cone beam computed tomography scans each), three treatment plans were made (wedge, simple intensity-modulated RT [IMRT], and full IMRT). For each treatment plan, four dose distributions were calculated. The first dose distribution was the original plan. The other three included the effects of patient setup errors (rigid displacement of the bony anatomy) or breast errors (e.g., rotations and shape changes of the breast with respect to the bony anatomy), or both, and were obtained through deformable image registration and dose accumulation. Subsequently, the effects of the plan type and error sources on target volume coverage, mean lung dose, and excess dose were determined. Results: Systematic errors of 1-2 mm and random errors of 2-3 mm (standard deviation) were observed for both patient- and breast-related errors. Planning techniques involving glancing fields (wedge and simple IMRT) were primarily affected by patient errors ({approx}6% loss of coverage near the dorsal field edge and {approx}2% near the skin). In contrast, plan deterioration due to breast errors was primarily observed in planning techniques without glancing fields (full IMRT, {approx}2% loss of coverage near the dorsal field edge and {approx}4% near the skin). Conclusion: The influences of patient and breast errors on the dose distributions are comparable in magnitude for whole breast RT plans, including glancing open fields, rendering simple IMRT the preferred technique. Dose distributions from planning techniques without glancing open fields were more seriously affected by shape changes of the breast, demanding specific attention in partial breast planning techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultra-high (>30%) coupling efficiency designs for demonstrating central hot-spot ignition on the National Ignition Facility using a Frustraum

A new hohlraum geometry or “Frustraum” is proposed that may enable 2–3× higher capsule absorbed x-ray energy than for nominally sized capsules in standard cylinders. The Frustraum geometry comprises two truncated conical halves (or “frusta”) joined at the waist. An associated larger waist volume above the capsule allows fielding ∼50% larger capsules than the nominal 1 mm (radius) scale. A key feature of the Frustraum is that the outer laser cones strike the Frustraum ends at a higher glancing angle (by ∼23°) compared with a cylinder and generate more specular reflection. A scenario for boosted symmetry control from the outer cones reflecting off a glancing angle hohlraum wall depends on the choice of electron flux limit in the simulations. Recent data from the National Ignition Facility using oversized aluminum shells in rugby-shaped hohlraums [Ping et al., Nat. Phys. 15, 138 (2019)] come closest to approximating a Frustraum and are consistent with a flux limit of 0.03–0.04 in matching the simulated Dante drive history, the backlit trajectory of the Al shell, neutron yield, and implosion time. Applying this simulation methodology to hot-spot ignition designs in a Frustraum shows effective symmetry control and sufficient drive (∼290 eV) to enable high yield, moderate convergence implosions. Simulations suggest that adjusting the obliquity of the Frustraum wall is a robust lever for symmetry tuning. A high adiabat (α = 4.6) ignition design with a shortened laser pulse (<7 ns) is proposed to provide further margin to potential late-time loss of symmetry control from hohlraum filling and anomalous sources of fuel preheat.

Amendt, Peter↗

Molecular Mechanisms of Circadian Regulation During Spaceflight

Disruption of the regular environmental circadian cues in addition to stringent and demanding operational schedules are two main factors that undoubtedly impact sleep patterns and vigilant performance in the astronaut crews during spaceflight. Most research is focused on the behavioral aspects of the risk of circadian desynchronization, characterized by fatigue and health and performance decrement. A common countermeasure for circadian re-entrainment utilizes blue-green light to entrain the circadian clock and mitigate this risk. However, an effective countermeasure targeting the photoreceptor system requires that the basic circadian molecular machinery remains intact during spaceflight. The molecular clock consists of sets of proteins that perform different functions within the clock machinery: circadian oscillators (genes whose expression levels cycle during the day, keep the pass of cellular time and regulate downstream effector genes), the effector or output genes (those which impact the physiology of the tissue or organism), and the input genes (responsible for sensing the environmental cues that allow circadian entrainment). The main environmental cue is light. As opposed to the known photoreceptors (rods and cones), the non-visual light stimulus is received by a subset of the population of retinal ganglion cells called intrinsically photosensitive retinal ganglion cells (ipRGC) that express melanopsin (opsin 4 -Opn4-) as the photoreceptor. We hypothesize that spaceflight may affect ipRGC and melanopsin expression, which may be a contributing cause of circadian disruption during spaceflight. To answer this question, eyes from albino Balb/cJ mice aboard STS-133 were collected for histological analysis and gene expression profiling of the retina at 1 and 7 days after landing. Both vivarium and AEM (animal enclosure module) mice were used as ground controls. Opn4 expression was analyzed by real time RT/qPCR and retinal sections were stained for Opn4 immunofluorescence. Opn4 was decreased (abrogated in one case) in retinas that concurrently showed higher evidence of oxidative stress. We propose that oxidative stress can lead to a decrease in melanopsin expression, likely via ipRGC loss or impairment, and thus, it can be a contributing factor to circadian disruption during spaceflight. Countermeasures contemplating the use of light should therefore be complemented with melanopsin expression maintenance and/or reduction in oxidative stress.

Zanello, Susana↗

Detection of Nonthermal Hard X-Ray Emission from the “Fermi Bubble” in an External Galaxy

We report new Chandra hard X-ray (>2 keV) and Jansky Very Large Array C-band observations of the nuclear super bubble of NGC 3079, an analog of the “Fermi bubble” in our Milky Way. We detect extended hard X-ray emission on the southwest (SW)side of the galactic nucleus with coherent multiwavelength features in radio, Hα, and soft X-ray. The hard X-ray feature has a cone shape with possibly a weak cap, forming a bubble-like structure with a diameter of∼1.1 kpc. A similar extended feature, however, is not detected on the northeast (NE)side, which is brighter in all other wavelengths such as radio, Hα, and soft X-ray. Scattered photons from the nuclear region or other nearby point-like X-ray bright sources, inverse Compton emission from cosmic-ray(CR)electrons via interaction with the cosmic microwave background, or any individually faint stellar X-ray source populations, cannot explain the extended hard X-ray emission on the SW side and the strongly NE/SW asymmetry. A synchrotron emission model, plus a thermal component accounting for the excess at∼1 keV, can well characterize the broadband radio/hard X-ray spectra. The broadband synchrotron spectra do not show any significant cutoff, and even possibly slightly flatten at higher energy. This rule out a loss-limited scenario in the acceleration of the CR electrons in or around this superbubble. As the first detection of kiloparsec-scale extended hard X-ray emission associated with a galactic nuclear superbubble, the spatial and spectral properties of the multiwavelength emissions indicate that the CR leptons responsible for the broadband synchrotron emission from the SW bubble must be accelerated in situ, instead of transported from the nuclear region of the galaxy.

Jiang-Tao Li↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

SU-C-9A-07: Fabrication and Calibration of a Novel High-Sensitivity Collimator for Brain SPECT Imaging

Purpose: We have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. The collimator was manufactured and initial evaluation has been completed. Methods: The collimator was time-consuming and challenging to build. Because our desired hole pattern required substantial variations in hole angle, we designed two supporting plates to securely position about 34,000 hexagonal, slightly tapered, 75-mm long steel pins. The holes in the plates were modeled to yield the desired focal length, hole length and septal thickness. Molten lead was poured in between the plates, and all pins were removed after cooling. The sensitivity gain compared to a fan-beam collimator was measured using a point source placed along the central ray at several distances from the collimator face. Visual inspection of the holes was not possible as the collimator was sealed so it could be safely mounted on a SPECT system. Therefore, we prepared a 2D array of 768, ∼48μCi Tc-99m point sources, separated by 1.6 cm. The array was imaged for 10 minutes at 4 shifted locations to reduce sampling distance to 8 mm. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 3 to 176. Examination of the projections of the 4×768 point sources revealed that fewer than 2% of the holes were fully or partially blocked, which indicates that the intensive manual fabrication process was very successful. Conclusion: We have designed and manufactured a novel collimator for brain SPECT imaging. As expected, the sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data will require a measured system function.

60 APPLIED LIFE SCIENCES↗