SEARCH · Engineering Papers
Results for “LIGHT SOURCE”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Stitching interferometry for synchrotron mirror metrology at National Synchrotron Light Source II (NSLS-II)
With the fast development of diffraction-limited storage rings and free electron lasers, the requirement for ultimate quality X-ray mirror is getting higher and the mirror surface needs to approach the sub-nm root mean square height specifications. Here, these ultimate specifications challenge the X-ray mirror metrology community. In this work, we present our developed dedicated stitching metrology platform for X-ray mirror metrology. Various stitching methods with different stitching parameters are investigated in our stitching interferometric system. Some experimental results are given to demonstrate its validity and performance. According to the measurement results, the repeatability of measuring a flat mirror in the software stitching mode is at 0.1 nm RMS level. In relative angle determinable stitching mode when measuring a curved mirror with its radius of curvature varying from 50 m to 175 m, the repeatability is around 1 nm RMS.
Carbon nanotubes as emerging quantum-light sources
Explore the source record for details and available documents.
Redefining artificial lighting through spectral engineering of light sources for well-being
Not Available
Development of contamination-free x-ray optics for next-generation light sources
We studied typical forms of contamination on X-ray mirrors that cause degradation of beam quality, investigated techniques to remove the contaminants, and propose methods to eliminate the sources of the contamination. The total amount of carbon-containing substances on various materials in the vicinity of a mirror was measured by thermal desorption-gas chromatography/mass spectrometry and thermal desorption spectroscopy. It was found that cleanliness and ultra-high vacuum techniques are required to produce the contamination-free surfaces that are essential for the propagation of high-quality X-ray beams. The reduction of carbonaceous residue adsorbed on the surfaces, and absorbed into the bulk, of the materials in the vicinity of the mirrors is a key step toward achieving contamination-free X-ray optics.
The fluctuation–dissipation measurement instrument at the Linac Coherent Light Source
The development of new modes at x-ray free electron lasers has inspired novel methods for studying fluctuations at different energies and timescales. For closely spaced x-ray pulses that can be varied on ultrafast time scales, we have constructed a pair of advanced instruments to conduct studies targeting quantum materials. We first describe a prototype instrument built to test the proof-of-principle of resonant magnetic scattering using ultrafast pulse pairs. This is followed by a description of a new endstation, the so-called fluctuation–dissipation measurement instrument, which was used to carry out studies with a fast area detector. In addition, we describe various types of diagnostics for single-shot contrast measurements, which can be used to normalize data on a pulse-by-pulse basis and calibrate pulse amplitude ratios, both of which are important for the study of fluctuations in materials. Furthermore, we present some new results using the instrument that demonstrates access to higher momentum resolution.
Toward streaked collective Thomson scattering measurements on an extreme ultraviolet plasma light source
Here we show through forward modeling calculations that streaked collective Thomson scattering measurements are feasible on laser-produced tin plasmas generated under conditions relevant for extreme ultraviolet lithography. Using a 532 nm probe laser beam, the feasibility of simultaneous measurements of electron plasma wave (EPW) and ion acoustic wave (IAW) spectra is investigated. Absolute photon counts for laser scattering off both waves are calculated. Probe laser electron heating and bremsstrahlung background radiation effects are accounted for. While a large spatiotemporal region can be successfully probed based on the IAW feature, only one measurement location can be accessed through the EPW as a result of the low signal to noise ratio. A portable/traveling tabletop system is proposed.
Homogeneous broadening in the spectrum of a broadband erbium-doped fibre light source
Interference of wave trains separated out in an inhomogeneous emission spectrum of a superluminescent erbium-doped fibre source has been studied by scanning the wavelength of a spectrum analyser. The results demonstrate that, as the spectral resolution of the spectrum analyser decreases to a level corresponding to a sharp drop in interference fringe visibility relative to its original level, near 100 %, fringe visibility becomes dependent on the wavelength in the inhomogeneous spectrum of the source. The reason for this is that, at some characteristic resolution δλ (δλ > 0.5 nm in our case), the coherence time of wave trains is not limited by the spectral resolution of the spectrum analyser and is related to the inhomogeneous spectrum of the source, whose limiting width can be thought of as the homogeneous linewidth in the spectrum of the source. This feature can be used for evaluating homogeneous line broadening. (paper)
In situ temperature synthesis and characterization of ferroelectric PZN-4.5PT nanoparticles’ thin films using synchrotron light source
Despite the excellent properties of Pb(Zn 1/3 Nb 2/3 )O 3 -4.5PbTiO 3 (PZN-4.5PT) single crystals, the greatest difficulty for their application on electronic devices is to make them to thin layers related to the difficulty to make them as ceramic materials. In this paper, we use the combined USAXS/SAXS/WAXS instrument at 9ID beamline at APS-ANL for in situ characterization of PZN-4.5PT inorganic perovskite nanoparticles thin films deposited on nanotextured silicon to understand the phase transitions and determine the observed microcrystals' structure. Here, the sample was annealed from ambient to 1000°C. The results revealed structure changes in the nanoparticles' thin films which could be explained by the new phase that can be assigned to the Pb 3 (PO 4 )2-based component. The peak at 31° indicates the presence of the rhombohedral phase perovskites assigned to the nanoparticles. WAXS characterization permitted to identification of many transitions during thermal annealing like dehydration or dihydroxylation of phosphorus gel -OH bonds and internal water.
Third User Workshop on High-Power Lasers at the Linac Coherent Light Source
Not Available
Fourth User Workshop on High-Power Lasers at the Linac Coherent Light Source
Not Available
Matter under extreme conditions experiments at the Linac Coherent Light Source
Not Available
Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes
Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.
Beam shaping to improve the free-electron laser performance at the Linac Coherent Light Source
Not Available