Prediction of rotating-blade vortex noise from noise of nonrotating blades

Measurements were conducted in an acoustic wind tunnel to determine vortex noise of nonrotating circular cylinders and NACA 0012 airfoils. Both constant-width and spanwise tapered models were tested at a low turbulence level. The constant-diameter cylinder and constant-chord airfoil also were tested in the turbulent wake generated by an upstream cylinder or airfoil. Vortex noise radiation from nonrotating circular cylinders at Reynolds numbers matching those of the rotating-blade tests were found to be strongly dependent on surface conditions and Reynolds number. Vortex noise of rotating circular cylinder blades, operating with and without the shed wake blown downstream, could be predicted using data for nonrotating circular cylinders as functions of Reynolds number. Vortex noise of nonrotating airfoils was found to be trailing-edge noise at a time frequence equal to that predicted for maximum-amplitude Tollmein-Schlichting instability waves at the trailing edge.

Fink, M. R.↗

Ozone monitoring with an infrared heterodyne radiometer

Measurements of the total burden and of the concentration-versus-altitude profiles of ozone have been made with a ground-based heterodyne radiometer at Pasadena, California. The measurements were made in the 9.5-micron wavelength region, where a strong ozone infrared absorption band exists. The radiometer measured solar absorption at selected wavelengths with a spectral resolution of 0.001 reciprocal centimeter, equivalent to the half-width of an ozone absorption line at the 10-millibar altitude level. A carbon dioxide laser served as the local oscillator. This technique can be used to gather important data on both tropospheric and stratospheric ozone, which are not readily accessible with other remote-sensing techniques.

Menzies, R. T.↗

GRIS observations of the Galactic Center

The 511 keV positron annihilation line source in the Galactic Center (GC) region has reappeared after being in a quiescent state since the early 1980's. Observations are reported made by the GRIS balloon instrument showing that the 511 keV line has returned to an intensity level similar to that seen in the 1970's. The line width was resolved for the first time and a measurement of the spatial extent of the emission along the galactic plane was made. Gamma ray imaging spectrometer (GRIS) is a high resolution germanium (Ge) spectrometer with a 17 deg field-of-view. Eleven hours of data were obtained from GC pointings on balloon flights over Australia on 1 May 1988 and again on 29 October 1988. An additional seven hours were obtained on 30 October 1988 from a point in the galactic plane (GP) 25 deg west of the center. Preliminary results for the line fluxes from the GC are 9.8 + or - 1.9 in May and 12.3 + or - 1.6 in October, and from the GP are 2.4 + or - 1.6 (1 sigma statistical errors). The flux for the off-center pointing is significantly lower than that for the GC pointings and indicates that the dominant emission is narrowly concentrated at the center. The line width for the GC pointing in October is 3.6 + or - 0.5 keV, which implies a temperature for the annihilation medium of less than or + 10(exp 5)K. A step in the continuum emission at 511 keV is found in both the GC and GP data. The step may be due to orthopositronium three-photon annihilation for the GC, but is too large relative to the 511 keV line for the GP to be simply explained by positronium.

Gehrels, N.↗

The cavity heat pipe Stirling receiver for space solar dynamics

The receiver/storage unit for the low-earth-orbiting Stirling system is discussed. The design, referred to as the cavity heat pipe (CHP), has been optimized for minimum specific mass and volume width. A specific version of this design at the 7-kWe level has been compared to the space station Brayton solar dynamic design. The space station design utilizes a eutectic mixture of LiF and CaF2. Using the same phase change material, the CHP has been shown to have a specific mass of 40 percent and a volume of 5 percent of that of the space station Brayton at the same power level. Additionally, it complements the free-piston Stirling engine in that it also maintains a relatively flat specific mass down to at least 1 kWe. The technical requirements, tradeoff studies, critical issues, and critical technology experiments are discussed.

Kesseli, James B.↗

Laser welding in a reduced gravity environment

Preliminary results on the effects of reduced gravity on laser welding of stainless steel and other materials are reported. Laser welding experiments using a low power (10-18 watts) Nd-YAG laser have been performed on the NASA KC-135, which flies parabolic maneuvers to simulate reduced gravity conditions. Experiments on 0.005-0.010 inch thick stainless steel samples displayed a pronounced change in weld bead width, depth of penetration and surface ripple with changes in gravity level.

Workman, Gary L.↗

MRO's High Resolution Imaging Science Experiment (HiRISE): Polar Science Expectations

The Mars Reconnaissance Orbiter (MRO) is expected to launch in August 2005, arrive at Mars in March 2006, and begin the primary science phase in November 2006. MRO will carry a suite of remote-sensing instruments and is designed to routinely point off-nadir to precisely target locations on Mars for high-resolution observations. The mission will have a much higher data return than any previous planetary mission, with 34 Tbits of returned data expected in the first Mars year in the mapping orbit (255 x 320 km). The HiRISE camera features a 0.5 m telescope, 12 m focal length, and 14 CCDs. We expect to acquire approximately 10,000 observations in the primary science phase (approximately 1 Mars year), including approximately 2,000 images for 1,000 stereo targets. Each observation will be accompanied by a approximately 6 m/pixel image over a 30 x 45 km region acquired by MRO s context imager. Many HiRISE images will be full resolution in the center portion of the swath width and binned (typically 4x4) on the sides. This provides two levels of context, so we step out from 0.3 m/pixel to 1.2 m/pixel to 6 m/pixel (at 300 km altitude). We expect to cover approximately 1% of Mars at better than 1.2 m/pixel, approximately 0.1% at 0.3 m/pixel, approximately 0.1% in 3 colors, and approximately 0.05% in stereo. Our major challenge is to find the dey contacts, exposures and type morphologies to observe.

McEwen, A.↗

Digital Synchronizer without Metastability

A proposed design for a digital synchronizing circuit would eliminate metastability that plagues flip-flop circuits in digital input/output interfaces. This metastability is associated with sampling, by use of flip-flops, of an external signal that is asynchronous with a clock signal that drives the flip-flops: it is a temporary flip-flop failure that can occur when a rising or falling edge of an asynchronous signal occurs during the setup and/or hold time of a flip-flop. The proposed design calls for (1) use of a clock frequency greater than the frequency of the asynchronous signal, (2) use of flip-flop asynchronous preset or clear signals for the asynchronous input, (3) use of a clock asynchronous recovery delay with pulse width discriminator, and (4) tying the data inputs to constant logic levels to obtain (5) two half-rate synchronous partial signals - one for the falling and one for the rising edge. Inasmuch as the flip-flop data inputs would be permanently tied to constant logic levels, setup and hold times would not be violated. The half-rate partial signals would be recombined to construct a signal that would replicate the original asynchronous signal at its original rate but would be synchronous with the clock signal.

Simle, Robert M.↗

Experimental and Semiclassical Stark Widths and Shifts for Spectral Lines of Neutral and Ionized Atoms (A Critical Review of Experimental and Semiclassical Data for the Period 2008 through 2020)

This Review Article compares new experimental and corresponding semiclassical Stark broadened data for non-hydrogenic spectral lines of neutral atoms and positive ions. This Review covers the period 2008 until the end of 2020 and presents the continuation of previous critical reviews from 1976 (two), 1984 (two), 1990, 2002, and one from 2009. This Review reports the Stark broadening parameters of 1665 spectral lines belonging to 35 elements with 61 different atomic and ion species. The data are taken from 60 papers. Experimental data are arranged by elements and spectra, and these are reported in tables in alphabetical and numerical order, respectively. Each experimental Stark broadening parameter is followed with estimated accuracy. The experimental Stark broadening and shift data presented in the tables are compared with the corresponding semiclassical results available in the literature. In addition, for comparison experiments versus semiclassical theoretical Stark broadening parameters, a numerically improved theoretical approach developed based on Griem and co-workers’ theory is used to evaluate Stark widths and shifts of all studied lines whenever required atomic energy levels data and transition probabilities are available. At the end of the text report, for each analyzed neutral or ion species, the information about the location of the same species data in preceding reviews is given.

Plasma line broadening↗

First observation of γ γ → p p ¯ K + K - and search for exotic baryons in p K systems

The process γ γ → p p ¯ K + K - and its intermediate processes are measured for the first time using a 980 fb - 1 data sample collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. The production of p p ¯ K + K - and a Λ ( 1520 ) 0 ( Λ ¯ ( 1520 ) 0 ) signal in the p K - ( p ¯ K + ) invariant mass spectrum are clearly observed. However, no evidence for an exotic baryon near 1540 MeV / c 2 , denoted as Θ ( 1540 ) 0 ( Θ ¯ ( 1540 ) 0 ) or Θ ( 1540 ) + + ( Θ ( 1540 ) - -- ), is seen in the p K - ( p ¯ K + ) or p K + ( p ¯ K - ) invariant mass spectra. Cross sections for γ γ → p p ¯ K + K - , Λ ( 1520 ) 0 p ¯ K + + c . c . and the products σ ( γ γ → Θ ( 1540 ) 0 p ¯ K + + c . c . ) B ( Θ ( 1540 ) 0 → p K - ) and σ ( γ γ → Θ ( 1540 ) + + p ¯ K - + c . c . ) B ( Θ ( 1540 ) + + → p K + ) are measured. We also determine upper limits on the products of the χ c 0 and χ c 2 two-photon decay widths and their branching fractions to p p ¯ K + K - at the 90% credibility level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-574: Novel Chance-Constrained Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a probabilistic framework, namely chanceconstrained optimization, in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to hedge against the influence of uncertainties and improve robustness of treatment plans. Methods: IMPT plans were generated for a typical prostate patient. Nine dose distributions are computed — the nominal one and one each for ±5mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. These nine dose distributions are supplied to the solver CPLEX as chance constraints to explicitly control plan robustness under these representative uncertainty scenarios with certain probability. This probability is determined by the tolerance level. We make the chance-constrained model tractable by converting it to a mixed integer optimization problem. The quality of plans derived from this method is evaluated using dose-volume histogram (DVH) indices such as tumor dose homogeneity (D5% – D95%) and coverage (D95%) and normal tissue sparing like V70 of rectum, V65, and V40 of bladder. We also compare the results from this novel method with the conventional PTV-based method to further demonstrate its effectiveness Results: Our model can yield clinically acceptable plans within 50 seconds. The chance-constrained optimization produces IMPT plans with comparable target coverage, better target dose homogeneity, and better normal tissue sparing compared to the PTV-based optimization [D95% CTV: 67.9 vs 68.7 (Gy), D5% – D95% CTV: 11.9 vs 18 (Gy), V70 rectum: 0.0 % vs 0.33%, V65 bladder: 2.17% vs 9.33%, V40 bladder: 8.83% vs 21.83%]. It also simultaneously makes the plan more robust [Width of DVH band at D50%: 2.0 vs 10.0 (Gy)]. The tolerance level may be varied to control the tradeoff between plan robustness and quality. Conclusion: The chance-constrained optimization generates superior IMPT plan compared to the PTV-based optimization with explicit control of plan robustness. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scattering Solar Thermal Concentrators

This program set out to explore a scattering-based approach to concentrate sunlight with the aim of improving collector field reliability and of eliminating wind loading and gross mechanical movement through the use of a stationary collection optic. The approach is based on scattering sunlight from the focal point of a fixed collection optic into the confined modes of a sliding planar waveguide, where it is transported to stationary tubular heat transfer elements located at the edges. Optical design for the first stage of solar concentration, which entails focusing sunlight within a plane over a wide range of incidence angles (>120 degree full field of view) at fixed tilt, led to the development of a new, folded-path collection optic that dramatically out-performs the current state-of-the-art in scattering concentration. Rigorous optical simulation and experimental testing of this collection optic have validated its performance. In the course of this work, we also identified an opportunity for concentrating photovoltaics involving the use of high efficiency microcells made in collaboration with partners at the University of Illinois. This opportunity exploited the same collection optic design as used for the scattering solar thermal concentrator and was therefore pursued in parallel. This system was experimentally demonstrated to achieve >200x optical concentration with >70% optical efficiency over a full day by tracking with <1 cm of lateral movement at fixed latitude tilt. The entire scattering concentrator waveguide optical system has been simulated, tested, and assembled at small scale to verify ray tracing models. These models were subsequently used to predict the full system optical performance at larger, deployment scale ranging up to >1 meter aperture width. Simulations at an aperture widths less than approximately 0.5 m with geometric gains ~100x predict an overall optical efficiency in the range 60-70% for angles up to 50 degrees from normal. However, the concentrator optical efficiency was found to decrease significantly with increasing aperture width beyond 0.5 m due to parasitic waveguide out-coupling loss and low-level absorption that become dominant at larger scale. A heat transfer model was subsequently implemented to predict collector fluid heat gain and outlet temperature as a function of flow rate using the optical model as a flux input. It was found that the aperture width size limitation imposed by the optical efficiency characteristics of the waveguide limits the absolute optical power delivered to the heat transfer element per unit length. As compared to state-of-the-art parabolic trough CPV system aperture widths approaching 5 m, this limitation leads to an approximate factor of order of magnitude increase in heat transfer tube length to achieve the same heat transfer fluid outlet temperature. The conclusion of this work is that scattering solar thermal concentration cannot be implemented at the scale and efficiency required to compete with the performance of current parabolic trough CSP systems. Applied within the alternate context of CPV, however, the results of this work have likely opened up a transformative new path that enables quasi-static, high efficiency CPV to be implemented on rooftops in the form factor of traditional fixed-panel photovoltaics.

14 SOLAR ENERGY↗

Multispectrum analysis of the v9 band of 12C2H6: Positions, intensities, self- and N2-broadened half-width coefficients

Line positions, intensities, Lorentz self- and N2-broadened half-width coefficients have been measured for PQ3, PQ2, PQ1, RQ0,RQ1, RQ2, and RQ3 sub-band transitions in the 9 fundamental band of 12C2H6. A multispectrum nonlinear least-squares fitting technique was used to fit up to 17 high-resolution (~0.00156 cm-1), room temperature absorption spectra of pure (99.99% chemical purity) natural sample of ethane and lean mixtures of the high-purity ethane diluted with N2. A Bruker IFS 120HR Fourier transform spectrometer located at the Pacific Northwest National Laboratory (PNNL), in Richland, Washington was used to record the data. A standard Voigt line shape was assumed to fit all the data since no line mixing or other non Voigt line shapes were required to fit any of the spectra used in the analysis. Short spectral intervals (~2 to 2.5 cm-1) of all 17 spectra covering a specific PQ or RQ sub band were fit simultaneously. For the first time in an ethane band, pressure-broadened half-width coefficients were determined for each of the torsional-split components. Constraints were used such that the half-width coefficients of both torsional-split components were identical for a specific broadening gas. No pressure-induced shift coefficients were necessary to fit the spectra to their noise level. The present study revealed for the first time the dependence of self- and N2-broadened half-width coefficients upon the J, K quantum numbers of the transitions in ethane. A number of transitions belonging to the 9+ 4- 4 and the 9+2 4-2 4 hot bands were also observed in the fitted regions and measurements were made when possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of 3D dose distributions for HDR {sup 192}Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system

Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high–dose rate (HDR) iridium-192 ({sup 192}Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of {sup 192}Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with {sup 192}Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3 mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at 50% and 70% and 2 coordinates at 30% profile widths. The point source measurements and calculations for 50% profile widths revealed a difference > 3 mm in 1 coordinate on the sagittal plane and 2 coordinates on the axial plane. The doses of 3 coordinates on the sagittal plane and 4 coordinates on the axial plane could not be evaluated in 30% profile width because of low doses. There was good agreement between the gel dosimetry and TPS results. Gel dosimetry provides dose distributions in all 3 planes at the same time, which enables us to define the dose distributions in any plane with high resolution. It can be used to obtain 3D dose distributions for HDR {sup 192}Ir brachytherapy sources and 3D dose verification of TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectropolarimetry of Venus and Jupiter clouds - Information content of equivalent widths

The theory of the curve-of-growth for absorption lines formed in an anisotropically scattering medium, particularly the clouds of Venus and Jupiter, is generalized to the case of polarization. When the photon path-length distributions associated with each of Stokes' parameters (Il, Ir, and Q) are evaluated using Pade's approximations, analytical expressions can be derived for the corresponding equivalent widths. It is found that spectra of Q, derivable from the rotational temperature of the Q-lines, are formed at a level closer to the cloud top than the photopolarimetric level, rendering a more accurate location of the cloud top than possible by photopolarization. It is also demonstrated that simultaneous measurements of the equivalent widths of strong I- and Q-lines can provide analytical relations for retrieving the scale-height ratios of ambient gas-to-cloud particles and minor constituent-to-ambient gas molecules without resorting to any other independent measurement.

Buriez, J. C.↗

Lateral solids dispersion coefficient in large-scale fluidized beds

The design of fuel feed ports in a large-scale fluidized bed combustor depends on the fuel characteristics and lateral solids mixing. However, the reported values of the effective lateral solids dispersion coefficient (D{sub sr}) are scattered in the broad range of 0.0001-0.1 m{sup 2}/s. With the aim of predicting D{sub sr} in wider fluidized beds which is difficult to measure directly or deduce from experimental results in lab-scale facilities, a computational method is proposed. It combines the Eulerian-Granular simulation and fictitious particle tracing technique. The value of D{sub sr} is calculated based on the movement of the tracers. The effect on D{sub sr} of bed width (W) ranging from 0.4 m up to 12.8 m at different levels of superficial gas velocity (U{sub 0}) is investigated. It is found that increasing W whilst maintaining U{sub 0}, D{sub sr} initially increases markedly, then its increase rate declines, and finally it stays around a constant value. The computed values of D{sub sr} are examined quantitatively and compared with a thorough list of the measured D{sub sr} in the literature since 1980s. Agreed with the measurements performed in the pilot-scale fluidized beds, the value of D{sub sr} in wider facilities at higher fluidizing velocities is predicted to be around the order of magnitude of 0.1 m{sup 2}/s, much higher than that in lab-scale beds. Finally, the effect of D{sub sr} on the distribution of fuel particles over the cross section in fluidized beds with the specified layout of feed ports is discussed. (author)

42 ENGINEERING↗

Characterization of small microfluidic valves for studies of mechanical properties of bacteria

Lab-on-a-chip platforms present many new opportunities to study bacterial cells and cellular assemblies. Here, the authors describe a new platform that allows us to apply uniaxial stress to individual bacterial cells while observing the cell and its subcellular assemblies using a high resolution optical microscope. The microfluidic chip consists of arrays of miniature pressure actuated valves. By placing a bacterium under one of such valves and partially closing the valve by externally applied pressure, the cell can be deformed. Although large pressure actuated valves used in integrated fluidic circuits have been extensively studied previously, here the authors downsize those microfluidic valves and use flow channels with rectangular cross-sections to maintain the bacteria in contact with cell culture medium during the experiments. The closure of these valves has not been characterized before. First, these valves are modeled using finite element analysis, and then compared the modeling results with the actual closing profiles of the valves, which is determined from absorption measurements. The measurements and modeling show with good agreement that the deflection of valves is a linear function of externally applied pressure and the deflection scales proportionally to the width of the flow channel. In addition to characterizing the valve, the authors show at a proof-of-principle level that it can be used to deform a bacterial cell at considerable magnitude. They found the largest deformations in 5 μm wide channels where the bacterial width and length increase by 1.6 and 1.25 times, respectively. Narrower and broader channels are less optimal for these studies. Finally, the platform presents a promising approach to probe, in a quantitative and systematic way, the mechanical properties of not only bacterial cells but possibly also yeast and other single-celled organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Directional Variations in Tidal Flow Multifractality and Intermittency

We explored distinct directional variations of multifractal and intermittent characteristics of ebb and flood flow velocities at nodule point, WA, tidal energy site, and complementary inspection on the East River, NY using scaling exponents of the structure function, distribution flatness, detrending moving average (DMA) analysis, multifractal detrended fluctuation analysis (MF-DFA), and high-order spectral moments. Our findings reveal that tidal flow presents higher long-range dependence (LRD) and intermittent levels for the ebb flow sections, whereas the flood flow sections exhibit a higher degree of multifractality and greater sensitivity to larger magnitude of turbulent fluctuations. We demonstrate that long-range dependence predominantly contributes to multifractal behavior in both ebb and flood flows, as evidenced by the significantly reduced multifractal spectrum width for temporally randomly permuted time series. Moreover, spectral kurtosis analysis uncovers a higher intermittent level across all frequency scales for ebb flow sections and reveals a distinct pattern of tidal flow intermittency differing from the monotonically increasing intermittent level observed in wall-bounded and grid turbulence. Finally, we demonstrate that DMA, MF-DFA, and high-order spectral moments provide more comprehensive insights than structure function scaling exponents and PDF flatness methods.

Cheng, Shyuan [Univ. of Illinois at Urbana-Champai↗

Spectrophotometry of Seyfert 2 galaxies and narrow-line radio galaxies

Results are reported for a spectrophotometric survey of several Seyfert 2 galaxies, intermediate Seyferts, and narrow-line radio galaxies. The emission-line spectra of the galaxies are analyzed, emphasizing line intensities, reddening, temperatures, densities, line strength correlations, line widths, and redshift differences. The continuous spectra are examined, and possible ionization sources are considered. It is found that: (1) there are no distinguishing differences between the spectra of Seyfert 2 galaxies and narrow-line radio galaxies; (2) the emission spectra are rich in lines from a wide range of ionization levels; (3) the continuum is starlight diluted by an underlying continuous spectrum; (4) the line widths of both classes of galaxies have the same distribution; (5) there appear to be regions of high and low ionization in the Seyfert 2 and narrow-line radio galaxies; (6) photoionization seems quite likely as the energy input to the gas; and (7) all the galaxies show a UV excess in their spectra.

Koski, A. T.↗