Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Examining the Impact of Overlying Aerosols on the Retrieval of Cloud Optical Properties from Passive Remote Sensing

Haywood et al. (2004) show that an aerosol layer above a cloud can cause a bias in the retrieved cloud optical thickness and effective radius. Monitoring for this potential bias is difficult because space ]based passive remote sensing cannot unambiguously detect or characterize aerosol above cloud. We show that cloud retrievals from aircraft measurements above cloud and below an overlying aerosol layer are a means to test this bias. The data were collected during the Intercontinental Chemical Transport Experiment (INTEX-A) study based out of Portsmouth, New Hampshire, United States, above extensive, marine stratus cloud banks affected by industrial outflow. Solar Spectral Flux Radiometer (SSFR) irradiance measurements taken along a lower level flight leg above cloud and below aerosol were unaffected by the overlying aerosol. Along upper level flight legs, the irradiance reflected from cloud top was transmitted through an aerosol layer. We compare SSFR cloud retrievals from below ]aerosol legs to satellite retrievals from the Moderate Resolution Imaging Spectroradiometer (MODIS) in order to detect an aerosol ]induced bias. In regions of small variation in cloud properties, we find that SSFR and MODIS-retrieved cloud optical thickness compares within the uncertainty range for each instrument while SSFR effective radius tend to be smaller than MODIS values (by 1-2 microns) and at the low end of MODIS uncertainty estimates. In regions of large variation in cloud properties, differences in SSFR and MODIS ]retrieved cloud optical thickness and effective radius can reach values of 10 and 10 microns, respectively. We include aerosols in forward modeling to test the sensitivity of SSFR cloud retrievals to overlying aerosol layers. We find an overlying absorbing aerosol layer biases SSFR cloud retrievals to smaller effective radii and optical thickness while nonabsorbing aerosols had no impact.

Coddington, O. M.↗

RF Reference Switch for Spaceflight Radiometer Calibration

The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve rejection. The use of open-circuit stubs instead of a via to provide an improved RF short is unique to this design. The stubs are easily tunable to provide high rejection at specific frequencies while maintaining very low insertion loss in-band.

Knuble, Joseph↗

Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material

Next-generation high-temperature thermoelectric-power-generating devices will employ segmented architectures and will have to reliably withstand thermally induced mechanical stresses produced during component fabrication, device assembly, and operation. Thermoelectric materials have typically poor mechanical strength, exhibit brittle behavior, and possess a wide range of coefficient of thermal expansion (CTE) values. As a result, the direct bonding at elevated temperatures of these materials to each other to produce segmented leg components is difficult, and often results in localized microcracking at interfaces and mec hanical failure due to the stresses that arise from the CTE mismatch between the various materials. Even in the absence of full mechanical failure, degraded interfaces can lead to increased electrical and thermal resistances, which adversely impact conversion efficiency and power output. The proposed solution is the insertion of a mechanically compliant layer, with high electrical and thermal conductivity, between the low- and high-temperature segments to relieve thermomechanical stresses during device fabrication and operation. This composite material can be used as a stress-relieving layer between the thermoelectric segments and/or between a thermoelectric segment and a hot- or cold-side interconnect material. The material also can be used as a compliant hot shoe. Nickel-coated graphite powders were hot-pressed to form a nickel-graphite composite material. A freestanding thermoelectric segmented leg was fabricated by brazing the compliant pad layer between the high-temperature p- Zintl and low-temperature p-SKD TE segments using Cu-Ag braze foils. The segmented leg stack was heated in vacuum under a compressive load to achieve bonding. The novelty of the innovation is the use of composite material that re duces the thermomechanical stresses en - countered in the construction of high-efficiency, high-temperature therm - o-electric devices. The compliant pad enables the bonding of dissimilar thermoelectric materials while maintaining the desired electrical and thermal properties essential for efficient device operation. The modulus, CTE, electrical, and thermal conductances of the composite can be controlled by varying the ratio of nickel to graphite.

Firdosy, Samad A.↗

Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis

Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.

Jones, Kelley, M.↗

Multi-Canted Coils, Tubes, and Structures

Coil, tube, and other structures configured with a plurality of individual coils, internal structures, legs or extensions with each having multiple cants per coil, internal structure, leg or extension, and wherein the cants formed therein allow for a load-deflection force when each is compressed. In addition, any horizontal or moment forces are substantially reduced and/or eliminated when a downward vertical force is applied, as minimal or no torsion is created in the individual coils, legs or extensions.

Jaster, Mark L.↗

Exploring Management of Arrival Spacing Using Route Extensions with Terminal Spacing Tools

Airports with shared runway operations between arrivals and departures can experience severe departure gridlock and delays during a heavy arrival push due to insufficient gaps in the arrival stream for aircraft to depart. The problem is accentuated in situations when a large gap in the arrival spacing has to be created at the last minute due to wake vortex separation requirements. At LaGuardia airport, wake vortex separation problems arise when a heavy jet, such as a B757, departing on Runway 31 needs additional spacing between arrivals on Runway 22. A standard solution for controllers in many airports in situations such as this is to extend the downwind leg of arrival aircraft to create extra space between the arrivals. The question addressed in this paper is how such route extensions would work with terminal scheduling operations, namely (1) the automated Terminal Sequencing and Spacing (TSS) tools and (2) a new scheduling tool which increases the availability of gaps for departure aircraft (Departure Sensitive Arrival Spacing or DSAS). In a simulated LaGuardia airport (LGA) Terminal Radar Approach Control (TRACON) airspace, two new RNAV arrival routes were created along with extensions to these routes. The arrival route from the south had a downwind leg extension near the airport in the final sector. The arrival route from the north had an extension in a feeder sector further from the airport. An exploratory one-hour run with the route extensions was compared to an hour run without the extensions. Topics included in the paper are 1) how the route extensions were developed, 2) a procedure outlining how the aircraft could be scheduled to the extensions and who would do it, and 3) the results of the exploratory run compared to the original run without the extensions. The results indicated that the extended downwind leg route helped to create a B757 departure gap in the middle of a packed arrival stream, resulting in a reduction of 11 minutes in average wait time for the B757s, but at a cost of increased controller self-reported workload from low to moderate.

time based flow management↗

Sublimation Protection Coatings for Thermoelectric Materials for Space Power Applications

The compounds such as Yb14MnSb11 are relatively new p-type thermoelectric materials, respectively. NASA's interest in these material are to replace the state-of-the-art Si-Ge legs of the current radioisotope thermoelectric generators (RTGs). Ideally, the hot end of this leg would operate at 1000 degrees C in the vacuum of space. These materials, however, suffer from a high sublimation rate at elevated temperatures and would require a coating in order to survive the required RTG lifetime of 14 years. The purpose of present work is to develop sublimation protection coatings for Yb14MnSb11 at temperatures up to 1000 degrees C. Coatings for Yb14MnSb11 present many challenges. The coating must not significantly react or interdiffuse with the substrate thereby degrading the substrate or consuming the coating, must remain intact and not crack or spall during thermal cycling prior to launch, and must be a good insulator both electrically and thermally so as not to provide a short circuit for either electron flow or heat through the coating rather than through the leg. Based on these requirements, several oxides have been selected as possible coating candidates. This paper discusses the development of slurry processes to deposit these oxides coatings on thermoelectric materials.

Sublimation↗

FUN3D and USM3D Analysis of the Propulsion Aerodynamic Workshop 2018 S-Duct Test Case

This work presents the results of Fun3D and USM3D analyses that were performed for the 4th AIAA Propulsion Aerodynamics Workshop (PAW). The PAW workshop is separated into three sections that focus on internal duct flows, nozzle flows and a special topic. This paper focuses on the internal duct flow section of PAW04 while an accompanying paper discusses the analyses performed for the nozzle portion. For the internal duct flow section, the PAW04 participants were provided with the two configurations consisting of an S-duct with and without aerodynamic interface plane (AIP) rake legs modeled. The participants were asked to perform a grid refinement study as well as a turbulence model study for the configuration with the rake legs. The analyses discussed here were performed on custom grids developed under the guidelines of the workshop. Additionally, the paper discusses the development and use of flow controllers for matching the desired flow characteristics. The results show that both solvers do well for predicting internal flow characteristics of the S-duct based on direct comparison with the experimental data. However, the CFD-to-CFD comparison proved to be more challenging due to the localized occurrence of supersonic flow near the rake legs when using the mass flow controller. A turbulence model study was performed to compare the two-equation SST model to the SA-QCR model. The results show that although the turbulence model does affect the solution, it makes a minimal impact on pressure recovery and inlet distortion intensity for this case. Suggestions for future workshops include gridding guidelines similar to those employed for the Drag Prediction Workshop series for the grid refinement study and a time accuracy study.

Carter, Melissa B.↗

Design of High-Accuracy Multiple Flyby Trajectories Using Constrained Optimization

The trajectory optimization technique described in this paper provides several distinct advantages over previous formulations. First, fully numerically integrated trajectory modeling is used. That is, no approximations to the trajectory are made and the inclusion of any level of complicated force models desired is allowed. Second, only trajectory propagation is used so there is no requirement for optimization. This is accomplished by the novel method of splitting the trajectory into independent legs, which are then subjected to constrained optimization. Third, each of the trajectory legs may be specified by any convenient set of parameters particularly useful for that leg. Any of these parameters may then be subject to constraints. Fourth, the nonlinear optimization problem is solved by solving a sequence of linear problems which converges to the optimal nonlinear solution. Fifth, the robustness of this formulation requires little or no user interaction with the optimization once a feasible problem has been posed.

flyby↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Evaluating The Relationships Between Supine Propriorception Assessments with Upright Functional Mobility and Balance Tests

INTRODUCTION Upon return to Earth, spaceflight sensorimotor adaptations can result in impaired posture and locomotion [1], [2], and current exercise countermeasures in the International Space Station are not sufficient to maintain sensorimotor function. In-flight countermeasures and assessment tools for sensorimotor function are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to 0.38 G on Mars. One proposed countermeasure for proprioceptive deconditioning includes training on a tilt board device [3], which will be tested in an upcoming bed rest study. In preparation for the said study, the objective of this pilot study is to compare performance in supine proprioceptive assessments to performance in functional upright activities. The results are intended to guide the selection of supine assessment tools for the upcoming bedrest study and the development of future inflight proprioceptive training and assessment tools for exploration missions. METHODS Seventeen healthy participants (8 males and 9 females, 27.9 ± 8.5 years) provided informed consent as approved by the Institutional Review Board (IRB) at NASA. A horizontal air-bearing sled was used to provide a proprioceptive challenge in a supine body orientation, allowing for mediolateral motion with minimal friction during supine stance [4]. Participants were loaded axially (30 to 60% body weight) with their feet on a vertically oriented tilt board and instructed to perform supine assessment activities using custom software that displays a cursor controlled by tilting the tilt board. In a single-leg static activity on the tilt board (TB-St), performance was measured as the percent time spent on a center target during a 30-second trial. During a two-feet dynamic activity on the tilt board (TB-Dy), performance was measured as the number of targets captured in 30 seconds. These supine tasks were compared to performance during two upright activities used to represent upright performance: completion time for a functional mobility task (FMT) [2],[5] and a performance score from force plate sway data during 30-second single-leg upright standing (USL). RESULTS AND DISCUSSION A Spearman's rank-order correlation was run to assess the relationship between upright and supine assessments. There were statistically significant, strong correlations between scores for the FMT and each TB activity, including TB-St, rs(17) = 0.50, p<0.05, TB-Dy3, rs(17) = 0.73, p<0.001, and TB-Dy9, rs(15) = 0.53, p<0.05. There were no statistically significant correlations between USL and each TB activity. Despite a lack of correlation with upright single-leg balance, the ability of the TB to indicate upright performance in the FMT is promising, as this task is a standard post-flight measure designed to characterize locomotor dysfunction [2], [5]. CONCLUSION These efforts will inform the selection of an appropriate sensorimotor assessment method for the upcoming bed rest study and similar future studies. While current work uses a bed rest analog to develop these technologies, future work aims to prepare capabilities for future in-flight sensorimotor training and assessment to mitigate the risks of proprioception impairment after spaceflight. ACKNOWLEDGEMENTS This work was supported by the University Space Research Association Internship Program. REFERENCES [1] Mulavara A.P. et al (2018) Med Sci Sports Exerc, 50(9), 1961-1980. [2] Mulavara A.P. et al (2010) Exp Brain Res, 202(3), 649-659. [3] Macaulay T.R. et al (2021) Front. Syst. Neurosci., 15, 658-985. [4] Goel R. et al (2017) Front. Syst. Neurosci, 11. [5] Koppelmans V. et al (2013) BMC Neurology, 12.

R Bellisle↗

Segmentally structured disk triboelectric nanogenerator

A generator includes a disc shaped first unit, a disc shaped second unit and an axle. The first unit includes a substrate layer, a double complementary electrode layer and an electrification material layer. The electrode layer includes a first electrode member and a second electrode member. The first electrode member includes evenly spaced apart first electrode legs extending inwardly. The second electrode member is complementary in shape to the first electrode member. The legs of the first electrode member and the second electrode member are interleaved with each other and define a continuous gap therebetween. The electrification material includes a first material that is in a first position on the triboelectric series. The second unit defines elongated openings and corresponding elongated leg portions, and includes a second material that is at a second position on a triboelectric series, different than the first position.

42 ENGINEERING↗

Harmonic filter for magnetic amplifier

A magnetic amplifier includes a permeable core having multiple legs. Control windings wound around separate legs are spaced apart and connected in series in an anti-symmetric relation. Harmonic filters are positioned adjacent to the control windings to attenuate even-ordered harmonics generated by alternating load current passing through a portion of the legs. The control windings bias magnetic flux arising from control current flowing through one of the control windings which is substantially equal to the biasing magnetic flux flowing into a second control winding. The flow of the control current through each of the control windings changes the reactance of the permeable core reactor by driving those portions of the permeable core that convey the biasing magnetic flux into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the permeable core.

42 ENGINEERING↗

Materials for thermoelectric energy conversion

A thermoelectric power generation (TEG) unit configured to be integrated into the exhaust system of a vehicle includes a plurality of thermoelectric power generator modules, each comprising an electrically interconnected plurality of p-type and n-type thermoelectric material legs, each leg extending between a substrate on a hot side and a substrate on a cold side of the module, wherein the thermoelectric materials for the legs are half-Heusler compounds having a thermoelectric figure of merit (ZT) greater than 1.0.

Samsonidze, Georgy↗

Experimental study on the guillotine break accident of the main steam line with Atlas

A main steam line break (MSLB) accident is defined as a pipe break in the main steam system of a nuclear power plant. The MSLB accident is characterized as cool-down event due to the increased steam flow rate, which causes excessive energy removal from the steam generators and eventually reactor coolant system. This results in a decrease in reactor coolant temperature. The cool-down causes an increase in core reactivity due to the negative moderator and Doppler reactivity coefficients. The thermalhydraulic integral effect test was performed to simulate a double-ended guillotine break accident of the main steam line of a pressurized water reactor. With an aim of simulating the MSLB accident as realistically as possible, a pertinent scaling approach was taken, especially focusing on a break flow. The main objectives of this test were not only to provide physical insight into the system response of a nuclear power plant during the MSLB accident but also to produce an integral effect test data to validate the safety analysis codes. In the present test, asymmetric thermal-hydraulic behavior was clearly observed between the loops. In the cold leg-1A and -1B where the affected steam generator is connected, the flow rates were higher and the fluid temperatures were lower than those in the cold leg-2A and -2B. This could be attributed to the excessive heat removal in the cold leg-1A and -1B through the affected steam generator. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes. Furthermore, this data can be utilized to identify any code deficiency for a MSLB simulation, especially for DVI-adapted plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity study of PWR upper vessel flow and phenomena using RELAP5-3D

During normal pressurized water reactor (PWR) operation, water enters the reactor pressure vessel (RPV) from the cold leg and exits through the hot leg. While most of this water flows through the downcomer and reactor core, a number of other flow paths exist, including the core baffle/bypass and the upper plenum spray. The upper plenum sprays normally account for a small fraction (less than 10%) of the total inlet flow, and provide cooling to the upper vessel dome and instrumentation/control rod channels. In the event of a loss-of-coolant accident (LOCA), especially one with core blockage, this alternative flow path may play a key role in maintaining core coolability. Because of the possible safety implications of the upper vessel flow, it is important to ensure the models used to simulate this region of the vessel are accurate. In this study, the model was altered to better reflect the internal flow path of the upper head and this was compared to the reference model. The simulation of interest is a hot leg double-ended guillotine (HL DEG) break followed later by a full blockage of the core and core bypass. In this scenario, the coolant can only reach the core through the upper spray bypass, so its impact on core coolability can be clearly seen. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Endovascular Treatment of Pelvic Congestion Syndrome: Visual Analog Scale (VAS) Long-Term Follow-up Clinical Evaluation in 202 Patients

PurposeThis study was designed to evaluate the clinical outcome and patients' satisfaction after a 5 year follow-up period for pelvic congestion syndrome (PCS) coil embolization in patients who suffered from chronic pelvic pain that initially consulted for lower limb venous insufficiency.MethodsA total of 202 patients suffering from chronic pelvic pain were recruited prospectively in a single center (mean age 43.5 years; range 27-57) where they were being treated for lower limb varices. Inclusion criteria were: lower limb varices and chronic pelvic pain (>6 months), >6 mm pelvic venous caliber in ultrasonography, and venous reflux or presence of communicating veins. Both ovarian and hypogastric veins were targeted for embolization. Pain level was assessed before and after embolotherapy and during follow-up using a visual analog scale (VAS). Technical and clinical success and recurrence of leg varices were studied. Patients completed a quality questionnaire. Clinical follow-up was performed at 1, 3, and 6 months and every year for 5 years.ResultsTechnical success was 100 %. Clinical success was achieved in 168 patients (93.85 %), with complete disappearance of symptoms in 60 patients (33.52 %). Pain score (VAS) was 7.34 {+-} 0.7 preprocedural versus 0.78 {+-} 1.2 at the end of follow-up (P < 0.0001). Complications were: groin hematoma (n = 6), coil migration (n = 4), and reaction to contrast media (n = 1). Twenty-three cases presented abdominal pain after procedure. In 24 patients (12.5 %), there was recurrence of their leg varices within the follow-up. The mean degree of patients' satisfaction was 7.4/9.ConclusionsCoil embolization of PCS is an effective and safe procedure, with high clinical success rate and degree of satisfaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗