Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCOE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Ultrasonic Characterization of Ethylene Vinyl Acetate (EVA) Crosslinking for Quality Assurance and Lamination Process Control (US-Xlink)

Module makers strive to cut lamination processing times to enhance production throughput and reduce costs. If overdone, this might lead to poor EVA quality due to incomplete EVA crosslinking and a large concentration of potentially harmful reactants. Those deficiencies are frequently missed during production quality testing as initially their impact on power output is small. Additionally, the crosslinking agent is frequently inhomogeneously dispersed across the EVA foils such that local destructive characterization procedures such as differential scanning calorimetry (DSC), Soxhlet extraction, swelling methods, or mechanical tests provide only a limited amount of information. However, these defects and inhomogeneities can become considerably more important during field operation, dramatically reducing long-term power yield, and increasing LCOE. Examples of typical long-term module degradation modes relating to poor lamination process conditions include cell breakage, corrosion of the metallization, delamination, and local quality deficiencies. To provide reliable material characterization in a manufacturing setting, we devised a non-destructive technology that uses ultrasound to evaluate the quality of interface adhesion and the degree of crosslinking. As a calibration reference, DSC measurements were employed. Although the potential of ultrasonic approaches for this purpose has already been noted, those previous methods were generally limited to local qualitative measurements. Furthermore, variations in EVA thickness and temperature had a substantial impact on them. The solution we propose solves these limitations by employing ultrasonic absorption rather than relying solely on sound velocity data.

14 SOLAR ENERGY↗

High Temperature Ceramic Heat Exchangers for the Gen3 Concentrated Solar Power Systems

As part of the Department of Energy’s Solar Energy Technology Office (SETO), the Concentrated Solar Power (CSP) Gen3 Demonstration Roadmap outlined the various technology pathways, goals, and technology needs/gaps to integrate CSP to a supercritical CO 2 (sCO 2 ) power cycle that operates at temperatures >700 °C. It is envisioned that the higher temperature power cycle will enhance the overall system efficiencies and reduce the levelized cost of electricity (LCOE) to meet a 2030 cost target of $0.05/kWhe for baseload CSP plants with ≥12 hours of storage. In this regard, there is a need for heat exchangers (HXs) that can operate at high sCO 2 pressures and temperatures >700 °C. Since current high-temperature alloys degrade at high temperatures, as part of this project, advanced ceramic materials, HX designs, and low-cost additive manufacturing approaches were developed to fabricate and evaluate the performance of the lab-scale ceramic HX prototypes.

14 SOLAR ENERGY↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Estimating National-Scale Wind Potential Using Spatially Explicit Turbine Layout Optimization

National renewable energy potential assessments play a broad and critical role in analysis of the clean energy transition by providing foundational estimates of developable clean resources. Common to all past wind potential assessments is an assumption that wraps the complexity of wind plant layout (arrangement of turbines) into a single metric known as capacity density, or rated power capacity per unit of land area. Quite often, a singular capacity density or rotor-diameter driven capacity density is used in wind potential assessments across broad geographies despite the complexities of local drivers. Here, we present a new wind technical potential assessment for the United States, leveraging a spatial optimization approach in lieu of the traditional uniform capacity density. The optimization approach is a spatially explicit method for determining the potential locations of individual wind turbines-taking into account the turbine configuration, plant economics and losses, wind resource, and siting considerations. Our approach accounts for the interactions between wind technology design, wind plant layout, and the vast array of regulatory, land use and infrastructure conflicts with wind development. Our results highlight the potential ability of larger turbines to enable increased wind capacity, up to a point, and increased generation when siting turbines in and around spatial constraints; moreover, they demonstrate and capture the LCOE benefit of relatively lower capacity densities and reduced wake losses when land is relatively abundant. These insights provide foundational knowledge for the wind sector as it develops and pursues future turbine models and as wind energy markets expand in zero-carbon futures. Further, when applied in capacity expansion models, supply curves developed by these methods can provide detailed local insights about where wind turbines might be deployed in and among known siting constraints for those regions where wind energy is determined to be economic, providing critical nuance to local decision-makers and stakeholders.

17 WIND ENERGY↗

Life-cycle costing assessment of back contact doping and encapsulation alternatives for increasing the life expectancy of CdTe PV modules (Final Report)

Contribution of Research to the State-of-Knowledge This research produced comparative sustainability evaluations of back contact doping and encapsulation alternatives considered by First Solar for decreasing degradation and increasing the life of the cadmium telluride (CdTe) photovoltaic (PV) modules. Technical Effectiveness and Economic Feasibility of Methods Investigated A holistic life-cycle-assessment of the alternatives considered for longer module operational lives, showed that they add between 0.2% and 2% to environmental impact indicators at the cradle-to-gate module level, but at the cradle-to-grave system level, alternative materials offer only benefits (i.e., environmental impact indicator decreases) to the public and the environment. Parallel experimental studies at First Solar showed that the use of the considered alternative materials did not impact the effectiveness of the current module recycling separations and material recovery processes. Furthermore, the increment on the module manufacturing cost due to using alternative materials was estimated to be negligible (i.e., >1%) and longer module lives more than compensate cost increases. Specifically, increase of the current warranted module life of 30 years to 50 years, would decrease the levelized cost of electricity (LCOE) from $40/MWh to $24/MWh for utility-scale installations in the US-SW, the economic feasibility of the considered alternatives is assured. Benefit to the Public With decreasing degradation from the current ~0.3%/year of Series 6 modules to less than 0.2%/year, the public will be benefited by longer photovoltaic operational lives, and therefore. In addition, the requirement for end-of-life management is shifted from 30 years to 40 or 50 years, with profound benefits to the public and the environment.

14 SOLAR ENERGY↗

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗

2022 Cost of Wind Energy Review [Slides]

The 12th annual Cost of Wind Energy Review, now presented in slide deck format, uses representative utility-scale and distributed wind energy projects to estimate the levelized cost of energy (LCOE) for land-based and offshore wind power plants in the United States.

17 WIND ENERGY↗

Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar Modules

The goals of this SETO project (DE-EE0008559, Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar modules) are to address the principal challenges towards the successful commercialization of perovskite solar modules utilizing scalable, high-throughput open-air spray deposition. The successful outcome of the project will provide the foundation of an all open-air spray deposited perovskite solar module with hole transport layer (HTL), perovskite, electron transport layer (ETL), and barrier layer development while establishing a fundamental understanding of perovskite device behavior under accelerated aging conditions. Through this program, we have made significant progress towards a commercializable pathway for perovskites. (1) We’ve demonstrated the successful open-air deposition of perovskite and transport layer materials. These deposition methods were chosen for their inherent scalability, and open-air processing enables a significant reduction in processing costs. These methods are also compatible with high throughputs, demonstrating the fastest perovskite film deposition at these performance levels. (2) Development of a unique all-fiber laser scribing procedure provides a high-performance, low-cost method for further improvements in scalability. (3) Our group has also placed a unique emphasis on device stability. The development of testing standards for perovskite modules is required to thoroughly evaluate potential candidates for commercialization, and we’ve taken inspiration from current industry standards to provide an honest insight into the performance and reliability of our devices. (4) An extensive cost model detailing the specific contributions of each device layer and production component provides the most thorough evaluation of any perovskite technology against conventional silicon and compound semiconductor solar devices. The cost model is a critical advancement that will provide the foundation for evaluating the levelized cost of energy (LCOE) of this technology.

14 SOLAR ENERGY↗

Advanced CO 2 Capture Solvent Systems for Dynamic Power Generation

RTI International, in collaboration with Pacific Northwest National Laboratory (PNNL), Carbon Capture Simulation for Industry Impact (CCSI 2 ), Electricity Power Research Institute (EPRI), and West Virginia University (WVU), successfully completed a joint research effort in developing a cost-effective, resilient, load-following advanced CO 2 capture technology for natural gas power plants. The project’s objective was to develop a CO 2 capture process that maximizes the net present value (NPV) of the electricity sale by minimizing the levelized cost of electricity (LCOE) under dynamic plant loads and high renewable penetration environments. The two key innovations developed in this project were the use of (i) advanced water-lean solvents (WLSs) and (ii) process intensification equipment, such as a rotating packed bed (RPB) absorber and dual-stage flash regeneration. The process’s low CO 2 capture cost is realized through WLSs’ low energy required for solvent regeneration, which lowers the operating cost while RPBs intensify the absorption process and reduces the power plant capital cost. A suite of advanced computational and simulation packages was implemented to guide the process design, validate the dynamic response of the capture plant, evaluate system-wide performance, and maximize the power plant’s profit. The project also engaged with power producers and other stakeholders to ensure its technical relevance and techno-economic viability. The development of this highly disruptive CO 2 capture technology could accelerate the industry adoption and thereby lower the greenhouse gas emissions of the U.S. power sector. Deployment of this technology can increase the reliability and decrease the cost of electricity generation in the U.S. by enabling the use of low-carbon fossil fuels to balance fluctuations of renewable energy availability.

03 NATURAL GAS↗

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase II Pre-Front End Engineering Design Study)

GTI Energy (GTI) and team members Southern Company Services (SCS), Pacific Gas & Electric (PG&E) and the Electric Power Research Institute (EPRI) performed a Phase II Pre-Feed Study under contract DE-FE0032008 for Hydrogen Storage for Load-Following and Clean Power. The configuration of the proposed system consists of subsystems for on-site H 2 production, on-site H 2 storage (up to 54 MWth in commercial vessels) and H 2 combustion in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with an existing fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load and H 2 production is relatively constant by storing H 2 . The proposed system is an improvement over alternate low carbon dispatchable power options. Technoeconomic analyses show H 2 produced with GTI’s patented Compact Hydrogen Generator (CHG) with inherent carbon capture will be lower cost (Levelized Cost of Hydrogen, LCOH) relative to hydrogen produced with a Steam Methane Reformer (SMR) with an amine system for carbon capture. This lower cost hydrogen enables our integrated system to deliver electricity (Levelized Cost of Electricity, LCOE) at 17.4% lower cost relative to a SMR sourced H 2 -fired HRSG (with an amine system for carbon capture) – Steam Turbine Generator (STG). Our analysis using EPRI’s US REGEN macroeconomic model shows our system will have significant demand in the power market and therefore require significant capacity expansion (CHG plants built to deliver hydrogen) to deliver low cost, low carbon power. In Phase II, our Team has completed a detailed system definition including the development of process models, definition of battery limits, Process Flow Diagrams (PFDs), Piping and Instrumentation Drawings (P&IDs), and a plant layout. A preliminary design for the key components of the CHG was developed including component lists & specifications. An evaluation of environmental and permitting considerations was completed and included the development of an Environmental Information Volume (EIV). The duct burners, which are flexible and can burn hydrogen and/or natural gas, were defined and initial CFD analyses were completed.

03 NATURAL GAS↗

Power Supply Options for the Marpi Landfill, Saipan: Feasibility Study

The Marpi Landfill, located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase the use of sustainable energy within the CNMI. CNMI has a 20% target for renewable energy consumption, as documented in Sustainable Development Goal #7 in the Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (GPO 2014). To accomplish these goals, the U.S. Department of Energy, through its Interagency Reimbursable Work Agreement with the Federal Emergency Management Agency, funded this feasibility study to assess and prioritize power supply options for the landfill. The availability of solar and wind resources varies seasonally, as does the load. A BESS can help to balance mismatches between generation and load on short (hourly or daily) timescales, but not across seasons. The microgrid scenarios evaluated for Marpi consider options for technology combinations that will both meet the load and utilize available resources, despite the challenge presented by higher loads and lower solar and wind availability during the rainy season, depicted in Figure ES-2. The seven scenarios evaluated are summarized in Table ES-1. Each scenario’s configuration was optimized to include component capacities that reduce capital and operating costs, meet the load, and minimize carbon emissions, as feasible. The costs and levelized cost of energy (LCOE) shown do not assume the use of any grant funding or incentives, although these options were also evaluated. To assist with decision-making, a prioritization matrix (Table ES-3) was created to compare the microgrid scenarios evaluated in this feasibility study according to various stakeholder priorities. The prioritization metrics were chosen based on discussions with OPD and will be finalized through stakeholder feedback. The scenarios were given a score between 1 and 7 for each prioritization metric (the lower the score, the higher the priority), and total scores were calculated using assigned weights based on the relative priority of each metric. The total scores were then ranked to produce a prioritized list of microgrid scenarios based on the metrics most important to the project stakeholders. As shown, scenario 4 (100 kW of solar PV, a 75 kW/300 kWh BESS, and 160 kW of diesel generation) ranks highest.

14 SOLAR ENERGY↗

SPBMI Microgrid

The SPBMI Microgrid Project aims to achieve four primary objectives that support. the tribe’s strategic goals, plans, and mission: 1) Ensure the availability of resilient energy for five essential tribal facilities as identified in the San Pasqual Hazard Mitigation Plan and described in the San Pasqual Energy & Resiliency Plan; 2) Provide solar generation sufficient to achieve net-zero energy consumption at the five essential facilities; 3) Reduce the tribe’s lifetime levelized costs of energy (LCOE); and 4) Support tribal energy objectives including reducing greenhouse gas emissions. Secondary objectives include supporting local workforce development and employment, in part by utilizing commercially available and warranted technologies that can be operated and maintained by tribal staff. Expected outcomes from the project include substantially eliminating long-duration disruptions to essential tribal services due to utility outages (which totaled 34 hours in 2017); reducing lifetime energy costs by approximately $1.75 million; and producing approximately 6.5 GWh of renewable electricity over the system’s lifetime.

14 SOLAR ENERGY↗

XCT System for Harvesting In-Current Hydrokinetic Energy from Low-Velocity Sites

The Project demonstrated the functionality of a cross cutting (XCT) type turbine in laboratory and open water testing. The fundamental design approach of locating small axial rotors near the ends of driving spars, which pull the rotors through the water at a multiple of the free-stream velocity eliminates the need (and thus the cost) for a gearbox and torque resisting structures. This configuration, however, introduces the complexity of transmitting electricity across a rotating interface. Even so, cost models indicate that depending on the anchoring and mooring system, LCOE less than $0.10/kWh should be possible in high capacity-factor sites with non-reversing currents.

13 HYDRO ENERGY↗

FY2023 NSTTF Annual Report

The National Solar Thermal Test Facility (NSTTF) is a DOE Core Capability and Technology Deployment Center located in Albuquerque, NM. It is operated by Sandia National Laboratories (Sandia) for the U.S. Department of Energy (DOE). The NSTTF is the only multi-mission, multi-use, multi-story test facility of its type in the United States. The NSTTF was founded in 1978 and began testing with high heat flux that same year. Over the past 45 years, the NSTTF has been at the forefront of the research, design, fabrication, and testing of many of the critical Concentrating Solar Power (CSP) technologies. These technologies have allowed costs to be dramatically reduced from over $\$ $0.40 /kWh to $\$$0.12 /kWh since the conception of this renewable energy technology. The NSTTF has worked to make the Solar Energy Generating Systems (SEGS) parabolic trough plants successful, while also working with the Solar One and Solar Two facilities for successful implementation. Over the four decades since its founding, the mission of the NSTTF has grown to include new receiver technologies, like our generation 3 falling particle system (G3P3 Tower), optical metrology techniques like SOFAST, molten salt testing, thermal energy storage, solar thermal chemistry, and more. We continue to expand our capabilities in pursuit of the DOE SETO mission and the DOE SunShot 2030 goals: unsubsidized LCOE of $\$$0.05/kWh for CSP that includes 12 or more hours of thermal energy storage. To support both the DOE SETO mission and support the CSP sector as a whole, we are working to develop our operations and maintenance framework to provide a world class testing facility in support of our technological achievements. To accomplish both of these missions, the NSTTF draws on the decades of experience and expertise of our staff along with the world-class facilities at Sandia National Laboratories to further the science of concentrated solar thermal technologies in diverse applications. We remain a trusted partner for high-quality and impactful research in both fundamental and applied arenas. We are able to provide our partners with both one-of-a-kind testing platforms as well as world-class analytics.

14 SOLAR ENERGY↗

Advanced Laboratory and Field Arrays (ALFA)/Lab Collaboration Project (LCP) for Marine Energy (Final Scientific/Technical Report)

The objective of the Advanced Laboratory and Field Arrays (ALFA) project was to reduce the Levelized Cost of Energy (LCOE) of Marine and Hydrokinetic (MHK) energy by leveraging research, development, and testing capabilities at Oregon State University, University of Washington, and the University of Alaska, Fairbanks. ALFA is a project within the Pacific Marine Energy Center (PMEC; formerly NNMREC), a multi-institution entity with a diverse funding base that focuses on research and development for marine renewables. The ALFA project aimed to accelerate the development of next-generation arrays of wave energy conversion (WEC) and tidal energy conversion (TEC) devices through a suite of field-focused R&D activities spanning a broad range of strategic opportunity areas identified in the Funding Opportunity Announcement: • Device and/or array operation and maintenance (O&M) logistics development; • High-fidelity resource characterization and/or modeling technique development and validation; • Array-specific component technology development (e.g. moorings and foundations, transmission, and other offshore grid components); • Array performance testing and evaluation; and • Novel cost-effective environmental monitoring techniques and instrumentation testing and evaluation. The objective of the Lab Collaboration Project (LCP) was to accelerate the development of next-generation marine energy conversion systems. The LCP aimed to achieve these project objectives in collaboration with the national laboratories by: • Developing concept generation and assessment tools; • Improving access to existing testing resources; • Validating collision risk models between fish and turbines; and • Advancing analysis and simulation capabilities for wave-WEC interactions and PTO analysis in nonlinear ocean waves. The ALFA portion of the project was comprised of six overarching technical tasks: • Task 1: Debris Modeling, Detection and Mitigation; • Task 2: Autonomous Monitoring & Intervention; • Task 3: Resource Characterization for Extreme Conditions; • Task 4: Robust Models for Design of Offshore Anchoring and Mooring Systems; • Task 5: Performance Enhancement for Marine Energy Converter (MEC) Arrays; and • Task 6: Evaluating Sampling Techniques for MHK Biological Monitoring. The LCP was divided into four overarching technical tasks: • Task 7: Project Management and Reporting • Task 8: Novel Design and Assessment Methodologies for Wave Energy Converter Design (Wave- SPARC) • Task 9: Testing Access for Commercial Marine Renewable Energy Technology Developers • Task 10: Quantifying Collision Risk for Fish and Turbines • Task 11: Nonlinear Ocean Waves and PTO Control Strategy Each ALFA/LCP task listed above functioned as a separate and discreet project. A final Technical Report was written for each individual task and these reports were uploaded to OSTI, after receiving DOE approval. The following document is a compilation of each of these final, approved reports arranged as individual chapters.

13 HYDRO ENERGY↗

Passivated Contacts for Direct Wafer Product (Final Technical Report)

This TCF project developed a thin-oxide (SiO 2 )/polycrystalline silicon (poly-Si) passivated contact solar cell on CubicPV's (formally 1366 Technologies, Inc.) Direct Wafer® Product (DWP) kerfless wafers. The project used two NREL-developed technologies described in U.S. Patent No. 9,911,873, Hydrogenation of Passivated Contacts and U.S. Patent Application Serial No. 15/890,172, Doped Passivated Contacts . The project was motivated by a potential higher efficiency cell (compared to a PERC cell) using passivated contacts on the ultra-low cost kerfless wafers grown using the Direct Wafer process. The hope was to accelerate market adoption of the cell and wafer by delivering the lowest LCOE in the PV industry. The project tested both n-type and p-type SiO 2 /poly-Si passivated contacts grown by thermal oxidation and plasma enhanced chemical vapor deposition (PECVD) of the poly-Si layer on DWP with varying wafer resistivities. Both deposition techniques are industry standards and thus economically viable methods for commercializing the contacts. The results indicated that both n-type and p-type poly-Si passivated contacts can be formed on polycrystalline DWP wafers, but implied open-circuit voltages (i Voc ) were limited to below 0.65 mV (compared with ~ 730 mV on n-Cz wafers). Diffusion of H to the Si/SiO 2 /poly-Si interface was key to obtaining high i Voc values. In this study, H was diffused from a high-temperature SiN x layer deposited over the poly-Si layer during a high-temperature firing step, similar to one used for screen printed metals. The study concluded that poly-Si passivated contacts on DWP wafers passivated the surface of the wafers as well as PERC passivated surfaces, which use a less expensive dielectric layer stack. The project showed that Direct Wafer Product wafers grown by CubicPV could produce high i Voc values (~0.647 mV), which could produce a cell over 20% efficient with proper processing and metallization. These cells, though not economically viable in 2024 as a stand-alone cell, could be integrated with a wide-bandgap top solar cell to form a two-junction tandem cell that could be viable under certain circumstances. This is because the bottom cell of a 30%, two-terminal tandem only needs to be a 20% cell under one-sun conditions. Thus, the DWP could be an ideal low-cost wafer for tandems. The project also revealed that a TOPCon type cell could be formed on a p-type DWP wafer using a P-diffused emitter and a p-type poly-Si contact. In fact, the p-type version of the poly-Si contact out-performed the n-type version for a variety of wafer resistivities, from highly doped to lowly doped. This curiosity requires more work to understand because on Cz wafers, the n-type poly-Si contact is of much higher quality than the p-type version.

14 SOLAR ENERGY↗

Offshore Wind Turbine Blade (85 to120meters ultra-long blade) static and fatigue test

Offshore blades are not just longer, they are wider, heavier and more flexible. These longer blades are a key component of larger wind turbines and for turbines to be more efficient in low wind speeds. These longer blades help reduce the LCOE further and make offshore wind even more competitive. As described earlier, it is essential for the blades to be fully tested to verify and validate the blade designs and manufacturing processes to ensure a reliable product is installed in the field. Through this project WTTC developed and procured new testing equipment required to test longer blades with larger deflections and higher loads. R&D’s BCDA system commissioned was the largest fatigue test exciter system in the world and set the bar for other blade testing facilities worldwide.

17 WIND ENERGY↗