Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotopes and Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Photochemistry and evolution of Mars' atmosphere - A Viking perspective

Viking measurements of the upper atmosphere of Mars have indicated thermospheric temperatures below 200 K, colder than those originally calculated by remote sensing experiments. It is suggested that dynamical coupling of the upper and lower regions of the Martian atmosphere may account for the variability in thermospheric temperature. The absorption of extreme ultraviolet solar radiation may account for observed ionospheric features, and may provide a source of fast N and O atoms escaping the planet's gravitational field. Measurements of the isotopic composition of O and N may be used to place constraints on models of the evolution of the Martian atmosphere. It is suggested that previous abundance of N2 may have exceeded that of CO2 in the present atmosphere, and that large sources of H2O may exist on the planet. The present degassing rate for nitrogen is felt to be less than the time-averaged degassing rate by at least a factor of 20.

Mcelroy, M. B.↗

Measurement of the 230 Th( p ,2n)Pa229 and 230 Th( p ,3n)Pa228 reaction cross sections from 14.1 to 16.9 MeV

Actinium-225 is of interest for medical isotope production and there is on-going research into methods of producing Ac 225 , either directly or via the decay of its parent isotopes ( Th 229 , Pa 229 , and Ra 225 ). One method that has been suggested is the Th 230 ( p , 2 n ) Pa 229 reaction. However, there is no available cross-section data for this reaction in the literature. Purpose: Measure the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reaction cross sections in the energy range where the ( p , 2 n ) reaction is predicted to peak to determine the feasibility of Ac 225 production via the Th 230 ( p , 2 n ) reaction. Methods: Targets naturally enriched in Th 230 were irradiated at the Center for Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory with energies ranging from 14.1 to 16.9 MeV. Furthermore, chemical processing was used to separate the protactinium activation products, followed by γ -ray spectroscopy to measure the activities of Pa 228 , 229 , 230 , 232 produced in the irradiation. Results: We find that excitation functions are reported for the first time in the literature for the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reactions in this energy range. The peak measured value of the Th 230 ( p , 2 n ) reaction was found to be 182 ± 12 mb at 14.4 ± 0.1 MeV. The Th 232 ( p , n ) Pa 232 reaction was used to verify the experimental conditions, the measured values are reported and are comparable to the existing literature values. From the γ -ray spectrometry data, the half-life of Pa 229 was measured as 1.5 ± 0.1 days, which is within the error of the half-life reported in the evaluated nuclear data as well as in the recent measurements, and the half-life of Pa 228 was measured as 19.5 ± 0.4 hours. Conclusions: Overall, the Th 230 ( p , 2 n ) Pa 229 reaction could reasonably be used for Ac 225 isotope production, although significant amounts of relatively isotopically pure Th 230 would be needed for significant production because the low alpha-decay branching ratio of Pa 229 and long half-life of Th 229 inhibit the in-growth of significant amounts of Ac 225 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Preliminary design of a mobile lunar power supply

A preliminary design for a Stirling isotope power system for use as a mobile lunar power supply is presented. Performance and mass of the components required for the system are estimated. These estimates are based on power requirements and the operating environment. Optimizations routines are used to determine minimum mass operational points. Shielding for the isotope system are given as a function of the allowed dose, distance from the source, and the time spent near the source. The technologies used in the power conversion and radiator systems are taken from ongoing research in the Civil Space Technology Initiative (CSTI) program.

Schmitz, Paul C.↗

Preliminary design of a mobile lunar power supply

A preliminary design for a Stirling isotope power system for use as a mobile lunar power supply is presented. Performance and mass of the components required for the system are estimated. These estimates are based on power requirements and the operating environment. Optimization routines are used to determine minimum mass operational points. Shielding for the isotope system is given as a function of the allowed dose, distance from the source, and the time spent near the source. The technologies used in the power conversion and radiator systems are taken from research in the Civil Space Technology Initiative (CSTI) program.

Schmitz, Paul C.↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAP-8 post shutdown gamma radiation approximations

Detector responses were calculated for normalized sources in the Perkins and King energy group structure for a SNAP 8 power system on a NASA space station. Gamma decay rates were then calculated by using an expanded, updated list of isotopic decay data, and from these, actual detector responses were found for the SNAP 8 system. The results indicate that energy-dependent calculations must be made to determine decay gamma dose rates for actual reactor configurations. A simplified method for making these calculations has been devised.

Byrn, N. R.↗

The isotopic composition of iron-group galactic cosmic rays

Results from studies of the isotopic composition of iron group elements in the galactic cosmic radiation are reviewed, emphasizing recently reported measurements from the ISEE-3 spacecraft. The observed isotope distributions for the elements Ti through Mn are in good agreement with those expected for a propagated solar-like source composition, with the possible exception of an enhanced abundance of Ti-50. It is found that a significant fraction of the radioactive secondary nuclide Mn-54 has decayed, indicating a confinement time of iron group cosmic rays in the galaxy of at least 2 Myr. The source ratio Fe-54/Fe-56 is found to be consistent with the solar value, but the ratio Ni-60/Ni-58 is greater than solar by a factor of 2.8+/-1.0. The measured abundance of Co-59 is significantly greater than the calculated secondary contribution, suggesting that this nuclide has been produced in the source regions by the electron capture decay of Ni-59 and implying a time delay between nucleosynthesis and acceleration approximately greater than 10(exp 5) yr.

Wiedenbeck, M. E.↗

Calculations of cosmogenic nuclide production rates in the Earth's atmosphere and their inventories

The production rates of cosmogenic isotopes in the Earth's atmosphere and their resulting terrestrial abundances have been calculated, taking into account both geomagnetic and solar-modulatory effects. The local interstellar flux was assumed to be that of Garcia-Munoz, et al. Solar modulation was accounted for using the heliocentric potential model and expressed in terms of the Deep River neutron monitor count rates. The geomagnetic field was presented by vertical cutoffs calculated by Shea and Smart and the non-vertical cutoffs calculated using ANGRI. The local interstellar particle flux was first modulated using the heliocentric potential field. The modulated cosmic-ray fluxes reaching the earth's orbit then interacted with the geomagnetic field as though it were a high-pass filter. The interaction of the cosmic radiation with the Earth's atmosphere was calculated utilizing the Bolztmann transport equation. Spallation cross sections for isotope production were calculated using the formalism of Silberberg and Tsao and other cross sections were taken from standard sources. Inventories were calculated by accounting from the variation in solar modulation and geomagnetic field strength with time. Results for many isotope, including C-14, Be-7 and Be-10 are in generally good agreement with existing data. The C-14 inventory, for instance, amounts to 1.75/sq cm(e)/s, in excellent agreement with direct estimates.

Obrien, K.↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardened beam instrumentations for multi-Mega-Watt beam facilities

The radiation hardened beam instrumentations workshop was held on February 3rd and 4th, 2022 to identify the technological challenges on the beam instrumentation for multi-Mega-Watt (MW) beam facilities. We invited a speaker from a high energy neutrino beam facility (CERN, Fermilab and J-PARC), a collider detector group (CERN and Fermilab), a neutron spallation source facility (ESS, J-PARC and SNS), and a rare-isotope beam facility (FRIB). Although, the operational beam parameter for each institution is unique due to their different physics goals, we realize that there is a common issue on the beam instrumentation. Therefore, it will be tackled by a collaborative R&D effort among facilities. We summarize an output from the workshop in the paper, and propose a possible R&D for the future radiation hardened beam instrumentations with a global effort.

43 PARTICLE ACCELERATORS↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

InterSpec v. 1.0.8

SAND2021-4823 O InterSpec decodes and displays gamma radiation data from a variety of handheld, laboratory, and fixed installation detector types. Once loaded, InterSpec provides a means to interactively analyze the data via a peak-based methodology. InterSpec assists with isotope identification and determines the source strength and shielding characteristics of the measured item. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, William↗

InterSpec v. 1.0.9

SAND2021-4823 O InterSpec decodes and displays gamma radiation data from a variety of handheld, laboratory, and fixed installation detector types. Once loaded, InterSpec provides a means to interactively analyze the data via a peak-based methodology. InterSpec assists with isotope identification and determines the source strength and shielding characteristics of the measured item. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, William↗