Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inlet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Impacts of electrode coating irregularities on polymer electrolyte membrane fuel cell lifetime using quasi in-situ infrared thermography and accelerated stress testing

In-line quality control diagnostics for roll-to-roll (R2R) manufacturing techniques will play a key role in the future commercialization of the polymer electrolyte membrane fuel cell (PEMFC) used in automotive applications. These diagnostics monitor the fabrication of the membrane electrode assembly (MEA), which detect and flag any non-uniformity that may potentially harm PEMFC performance and/or lifetime. This will require quantitative thresholds and a clear distinction between harmful defects and harmless coating irregularities. Thus, novel fuel cell hardware with quasi in-situ infrared (IR) thermography capabilities is utilized to understand how bare spots in the cathode electrode impact MEA lifetime. An accelerated stress test (AST) simulates chemical and mechanical degradation modes seen in vehicular operation. The actual open circuit voltage and rate of change of this voltage are used as in-situ indicators for MEA failure, enabling capture of the progression of failure point development. Bare spot coating irregularities located at the center of the electrode were found to have no impact on MEA lifetime when compared to a pristine MEA. However, MEA lifetime was found to be considerably shortened when these same irregularities are located at the cathode inlet and, especially, the anode inlet regions of the fuel cell.

36 MATERIALS SCIENCE↗

Thermal power plant upgrade via a rotating detonation combustor and retrofitted turbine with optimized endwalls

Over the past decade, pressure gain combustion research has promised over 10 percentage-points of increase in power plant thermal efficiency. Alas, to realize such potential gain, one must effectively couple the turbine with the detonation combustor, whose exhaust conditions differ substantially from current state of the art gas turbines. This paper presents a modeling approach that enables a superior thermodynamic cycle with a rotating detonation combustor and a retrofitted gas turbine by including a diffuser downstream of the combustor and by contouring the turbine endwall, while preserving the airfoil geometry. We propose a multi-step optimization strategy, parametrizing the endwall geometry with a few control points, without altering the airfoil geometry, and with the stage turbine efficiency as objective function. In a first step the turbine performance is assessed with steady inlet conditions by solving the steady three-dimensional Reynolds-Averaged Navier-Stokes equations. In a second step, the inlet conditions are unsteady, as predicted from a detonation combustor and a diffuser, and three-dimensional full unsteady simulations are performed with an unsteady Reynolds-Averaged Navier-Stokes solver. By altering the vane endwall, the steady optimization yielded an efficiency increase of 12% relative to the baseline, while the unsteady optimization resulted in 21% increase compared to the datum turbine. Finally, a full engine analysis demonstrated the superiority of pressure gain combustion which included a realistic thermodynamic cycle of the combustor, the diffuser and the optimized turbine components.

42 ENGINEERING↗

Development and evaluation of virtual refrigerant mass flow sensors for fault detection and diagnostics

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressor that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor is not delivering the expected flow due to a leaky suction or discharge valve or other internal fault, the energy-balance or EEV model can provide accurate flow estimates. In this paper, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics.

Kim, Woohyun↗

An uncertainty visualization framework for large-scale cardiovascular flow simulations: A case study on aortic stenosis

We present a generalizable uncertainty quantification (UQ) and visualization framework for lattice Boltzmann method simulations of high Reynolds number vascular flows, demonstrated on a patient-specific stenosed aorta. The framework combines EasyVVUQ for parameter sampling with large-eddy simulation turbulence modeling in HemeLB, and executes ensembles on the Frontier exascale supercomputer. Spatially resolved metrics, including entropy and isosurface-crossing probability, are used to map uncertainty in pressure and wall shear stress fields directly onto vascular geometries. Two sources of model variability are examined: inlet peak velocity and the Smagorinsky constant. Inlet velocity variation produces high uncertainty downstream of the stenosis where turbulence develops, while upstream regions remain stable. Smagorinsky constant variation has little effect on the large-scale pressure field but increases WSS uncertainty in localized high-shear regions. In both cases, the stenotic throat manifests low entropy, indicative of robust identification of elevated WSS. By linking quantitative UQ measures to three-dimensional anatomy, the framework improves interpretability over conventional 1D UQ plots and supports clinically relevant decision-making, with broad applicability to vascular flow problems requiring both accuracy and spatial insight.

Hemodynamics↗

Computational framework for modeling membrane processes without process and solution property simplifications

Accurately modeling membrane processes is critical to evaluating novel process configurations, designing scalable membrane systems, informing process cost estimates, and directing future research. Most membrane process models trade accuracy for computational efficiency by employing simplified approximations of the process (i.e. no salt flux, no pressure drop) and solution properties (i.e. ideal solution, and constant density, viscosity, and diffusivity). Our report introduces a detailed one-dimensional finite difference model for evaluating membrane processes that avoids these common simplifications. We apply this model to quantify the error introduced by these simplifications for case studies of reverse osmosis, osmotically assisted reverse osmosis, forward osmosis, and pressure retarded osmosis. While the magnitude of error introduced by these simplifications is reliant on the case study parameters and specifications, we find that existing model formulations can underestimate or overestimate average water flux by nearly 50% for some membrane processes operating under standard conditions. Lastly we investigate the error introduced by simplified inlet-outlet models that do not solve the governing system of differential equations, and we assess the accuracy of novel inlet-outlet formulations that use a log and geometric mean, instead of the typical arithmetic mean, to represent non-linear water flux profiles.

42 ENGINEERING↗

Undesirable Flow Behavior in a Proposed Validation Data Set

The next generation nuclear plant (NGNP), whose development is supported by the U. S. Department of Energy, will be a very high temperature reactor (VHTR). The VHTR is a single-phase helium-cooled reactor that will provide helium at up to 1000 C. The prospect of a coolant at these temperatures circulating in the reactor vessel demands that careful analysis be performed to ensure that excessively hot spots are not created and that sufficient mixing of the coolant is obtained. Computational fluid dynamics (CFD) coupled with heat transfer will be used to perform the desired analyses. However, primarily because of the imperfect nature of modeling turbulent flow, any CFD calculations used to perform nuclear reactor safety analysis must be validated against experimental data. Experimental data have been taken in a scaled section of the lower plenum of a prismatic VHTR at the matched index of refraction (MIR) facility at the Idaho National Laboratory. These data were taken with the intent that they be examined for use as validation data. A series of investigations have been conducted to assess the MIR data. Issues that have already been examined include the extent of the required computational domain, the outlet boundary condition, the inlet data and the effect of the turbulence model. One of the jets that flow into the model impacts on a wedge, which represents a portion of a hexagonal graphite block that lines the inner wall of the lower plenum. The nature of the flow below this particular jet is such that a randomly varying recirculation zone is created. This recirculation zone is seen to change in size, causing a relatively long-time scale of motion or disturbance of the flow in the model. It is concluded that such a feature is undesirable in a validation data set, firstly because of its apparent random nature and, secondly, because to obtain an appropriate long-time average would be impractical because of the compute time required. It is predicted computationally that by eliminating the first of the four inlet jets into the scaled model, the resulting recirculation zone is rendered stable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental study for critical heat flux in 2x2 rod bundles at high pressure conditions

Critical heat flux (CHF) phenomena has been a topic of study for over fifty years yet remains a serious concern across industries and especially in water-cooled nuclear reactor design. CHF data in the high-pressure range is limited, and the effects of bundle geometry and non-uniform heat flux profile are challenging to quantify. In this study, CHF experiments were performed in upward flowing water in a 2 × 2 rod bundle with a cosine profile heat flux. Data were collected between 16.5 and 18 MPa at two mass flux conditions with three inlet subcooling conditions. Under these conditions, average CHF was shown to decrease with increasing pressure. However, pressure had less of an effect than decreasing the inlet subcooling or the mass flux, both of which reduce the CHF value considerably. Of interest, correlations that have been developed for lower pressure continued to predict CHF occurrences with moderate accuracy outside their ranges of validity. Nearly all predicted values were within 20% of experimental values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical study of multi-component flow and mixing in a scaled fission product venting system

Numerical simulation of isothermal multi-component gas flow was conducted to study fluid flow and mixing in a scaled low-pressure, low-temperature test facility for the fission product venting system (FPVS) of a gas cooled fast reactor (GFR). The geometry of FPVS test facility was an open loop including gradual expansion coupling and two 90°pipe elbows. First, the validation of large eddy simulation (LES) wall-adapting local eddy-viscosity (WALE) turbulent model was performed for transitional flow in a circular pipe with gradual expansion. The reactingFOAM solver in OpenFOAM v8 was employed. By introducing appropriate turbulence disturbance at the flow inlet, such as turbulence intensity, the numerical results showed good agreement in (1) the velocity profile downstream of the pipe expansion measured by particle image velocimetry (PIV) in this study, and (2) the reattachment length reported in the literature. Using this validated model, the numerical simulation of flow and component mixing was performed for the FPVS with an inlet flowrate corresponding to a Reynolds number of 2,400 to investigate the flow behavior and component mixing. Standard deviation of the mass fraction of component, referred to as absolute mixing index (AMI), was calculated to quantify the mixing of components, showing that the component mixing length determined by AMI is related to the reattachment length downstream of the expansion. Additionally, this study was able to identify the best location in the FPVS test facility to measure the velocity and concentration profies where multicomponent flow is well mixed.

15 GEOTHERMAL ENERGY↗

CFD simulations of Molten Salt Fast Reactor core cavity flows

Computational Fluid Dynamics (CFD) has become increasingly important in the research and development of advanced nuclear reactors. Here, in the current study, extensive CFD simulations were conducted for the coolant flow in Molten Salt Fast Reactor (MSFR) core models using the state-of-the-art spectral element flow solver Nek5000 and multiscale coarse-mesh thermal-hydraulic software Pronghorn. The underlying motivation is to seek an in-depth understanding of how the internal velocity distribution can be influenced by the MSFR core cavity shape, the Reynolds number, turbulence modeling options and the inlet boundary conditions. The CFD techniques involved in this investigation range from coarse-mesh CFD, RANS modeling, to the high-fidelity LES calculations. Specifically, a series of RANS simulations were performed for the 2-D axisymmetric core model and 3-D wedge domains to study the flow distribution inside the MSFR core. It is observed that a proper representation of the MSFR inlet channel duct is important for the prediction of internal flow distribution. It is also showcased here how researchers can leverage the Nek5000 CFD results to calibrate more efficient coarse-mesh CFD tools, like Pronghorn, for the actual MSFR design needs. Moreover, this paper highlights a 3-D LES model for an entire MSFR core using the spectral element method and demonstrates the feasibility of this modeling approach. The readiness and potential limitations of the RANS approach are examined with respect to the high-fidelity LES simulations. The present investigation lays a solid foundation as we are leveraging the high-fidelity CFD capabilities to inform MSFR design efforts.

97 MATHEMATICS AND COMPUTING↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Applications of tribology to determine attrition by wear of particulate solids in CFB systems

In recent years, much attention has been focused on the development of novel technologies for carbon capture and chemicals production that utilize a circulating fluidized bed (CFB) configuration; examples include chemical looping combustion and circulation of temperature swing adsorbents in a CFB configuration for CO 2 capture. A major uncertainty in determining the economic feasibility of these technologies is the required solids makeup rate, which, among other factors, is due to impact and wear attrition at various locations, including standpipes, cyclones, and the gas jets in fluid beds. While correlations have been developed that estimate the attrition rates at these areas, these correlations are dependent on constants that are uncertain without extensive experiment in the corresponding unit operation. Thus, it is difficult to determine the attrition rate a priori without performing extensive experiments on the materials or scaling up entirely. In this work, the authors outline a methodology for predictive attrition based on fundamental material properties from fields of tribology—specifically, the study of wear—to the knowledge of forces and sliding distances determined from hydrodynamic models to develop basic attrition models for novel CFB systems. The equations are derived for the standpipe and cyclone, which are common components found in CFBs, and the cyclone equation is compared to experimental data of attrition in the literature. The cyclone equation derived in this work results in an abrasion rate based on (1) material properties such as particle density and hardness, (2) inlet velocity, and (3) cyclone geometry. According to this equation, increasing the diameter of the cyclone and the solids inlet velocity tends to increase the rate of abrasion of the catalyst, while decreasing the hardness increases the abrasion rate. The functionality of the increasing attrition rate with velocity increase implies that increasing the efficiency of the cyclone may also increase the attrition rate via abrasion. With modifications to the severity coefficient term to include the solids loading, the cyclone equation derived in this work fits data from Reppenhagen and Werther with a coefficient of determination (R2) of 92%.

01 COAL, LIGNITE, AND PEAT↗

Attrition of hematite particles for chemical looping combustion in a conical jet cup

The attrition of hematite particles for use in the chemical looping combustion process was investigated using a cold flow jet cup test. Jet cup attrition experiments are commonly used for bulk attrition testing of fluidized bed catalyst. The results indicate that the particle attrition in the jet cup cold flow experiments arises from surface abrasion due to particle-particle and particle-wall interactions. Experiments indicate that the measured cumulative mass loss increases with attrition time. However, the attrition rate decreases sharply at the early stage of attrition, and gradually, the rate decline slows and approaches a constant value with increasing attrition time. Furthermore, the influence of inlet gas velocity and solid inventory is discussed. As inlet gas velocities increase, the measured cumulative mass loss also increases. However, as the solid inventory increases, the cumulative mass loss decreases. The results also show that the jet cup experiments quantitatively compare with low magnitude tangential forces which is an indication of attrition through abrasion as the primary mechanism. It is determined through particle size distributions before and after which show a small shift of the main peaks with no peak broadening while producing a small number of fines. By using the mass of abraded fines and the widely-used Archard model for abrasive attrition, the specific wear rate coefficient can be predicted as a function of time. The wear coefficient calculation further identifies that the abrasion mechanism as the primary mechanism of attrition.

42 ENGINEERING↗

Sorption and desorption characteristics of a packed bed of clay-CaCl{sub 2} desiccant particles

Desiccants can be used in conjunction with solar energy to provide a viable alternative to traditional air conditioning techniques. A desiccant consisting of clay and calcium chloride was developed and tested using multiple sorption and desorption cycles. During sorption, inlet air temperatures from 23 to 36 C with corresponding relative humidities of 42-66% were tested. Additionally, superficial air velocities from 0.17 to 0.85 m/s were tested. During desorption, inlet air temperatures from 50 to 57 C and superficial air velocities of approximately 0.30 and 0.60 m/s were tested. A regression equation was determined for the mass of water sorbed by the clay-CaCl2 desiccant with a R{sup 2} value of 0.917. The desorption data was regressed to an exponential function and significant k-values were determined. An equation for pressure drop through the desiccant was determined and compared to existing models. The desiccant was found to perform well during the repeated test cycles though small masses of desiccant were lost due to surface disintegration of the desiccant spheres. (author)

14 SOLAR ENERGY↗

Fuzzy model representation of thermosyphon solar water heating system

The aim of this paper is to focus on improvement in prediction accuracy of model for thermosyphon solar water heating (SWH) system. The work employs grey-box modeling approach based on fuzzy system to predict the outlet water temperature of the said system. The prediction performance results are compared with neural network technique, which has been suggested by various researchers in the last one decade. The outlet water temperature prediction by fuzzy modeling technique is analyzed by using 3 models, one with three inputs (inlet water temperature, ambient temperature, solar irradiance), next with two inputs (inlet water temperature, solar irradiance) and last one with single input (solar irradiance/inlet water temperature). An improved prediction performance is observed with three inputs fuzzy model. (author)

14 SOLAR ENERGY↗

Theoretical and testing performance of an innovative indirect evaporative chiller

An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller successfully satisfy the indoor air conditioning load for the demo building. The indirect evaporative chiller has a potentially wide application in dry regions, especially for large scale commercial buildings. Finally, this paper presented the geographic regions suitable for the technology worldwide. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of a SiC-Si moving packed-bed particle-to-sCO 2 heat exchanger for high temperature concentrating solar power applications

Particle-based concentrating solar power systems integrated with sCO 2 power cycles offer high thermal efficiencies but require durable heat exchangers to transfer heat from high-temperature particles to the sCO 2 working fluid. Here, this study presents the design and optimization of a silicon carbide-silicon moving packed-bed heat exchanger for fabrication via binder jetting additive manufacturing. The heat exchanger was designed to withstand a 20 MPa sCO 2 pressure and operate at particle inlet temperatures up to 750 °C. The final design features 152 sCO 2 channels distributed across 19 plates, with elliptical corners and a minimum wall thickness of 3 mm. Flow restrictors at the sCO 2 channel inlets significantly improved flow uniformity, reducing thermal stresses and achieving a structural reliability of 99 % under representative operating conditions. The heat exchanger delivers a thermal duty of 9 kW and a volumetric power density of approximately 1 MW/m 3 in the channel region. Sensitivity studies confirmed the heat exchanger’s robustness under varying operating conditions, demonstrating its viability as a high-performance alternative to metallic heat exchangers for particle-based high-temperature concentrating solar power applications.

Barua, Bipul [Argonne National Laboratory (ANL), A↗

Experimental characterization of extreme temperature granular flows for solar thermal energy transport and storage

High-temperature, dense granular flows along an inclined plane were considered for solar thermal energy transport and storage with sintered bauxite particles. A series of experiments was performed for particle inlet temperatures of ~ 200, 400, 600, and 800 °C to understand the mechanisms of granular flows at extreme temperatures. Mass flow rates were measured using a load cell and free-surface velocities were measured and computed using particle image velocimetry. Surface temperatures were measured using infrared cameras. A significant decrease in steady-state particle mass flow rate was observed with increasing temperature due to changing flow properties. A decrease in bulk particle free-surface velocities was observed at higher temperatures. Free-surface velocity measurement error between experiments were within 20% of the average. The particle surface temperatures decreased from inlet to outlet with larger gradients at higher temperatures observed due to increasing convection and radiative heat losses. Here, a decrease in temperature was observed along the side walls due to a decrease in particle velocities.

14 SOLAR ENERGY↗