At least 487 records · Page 27

Remote spectral identification of surface aggregates by thermal imaging techniques - Progress report

The NASA Thermal Infrared Multispectral Scanner (TIMS) has been successfully used for the remote identification of a variety of soil and aggregate deposits in vegetated areas of two states. Over three million cubic meters of gravel deposits were identified from the imagery during a two year period. Verification was accomplished by ground reconnaissance using drilling machinery and by ground instrumentation. The method has been used to differentiate between fine and coarse grained soils, and gravel deposits. The deposits were found to have been naturally sorted according to grain size by depositional processes, providing each deposit with distinct spectral qualities. It was found that the masking effects of relatively dense vegetation were largely overcome by using imagery acquired at higher altitudes above terrain than 9000 meters, due to loss of resolution of the finer detail. The mechanics of image resolution are discussed, a method of data analysis used is described, and sample spectral signatures are illustrated.

Scholen, Douglas E.↗

Resolution improvement of remote sensing data.

Discussion of the theory of a technique for image restoration in the reconstruction of a spatial input scene mapped by a line scanner. Special attention is given to the application of this technique in reducing the data telemetered from the Infrared Scanning Radiometer of the Apollo 17 spacecraft. The technique is based on the theory of splines and uses the results of optimal approximation studies by Colomb (1959), Sard (1967), and Anselone (1968). A recursive algorithm is also developed to improve the reconstruction. The study treats a one-dimensional case, but the treatment can be readily extended to multi-dimensional situations.

Caprihan, A.↗

Determination of stratospheric temperature and height gradients from Nimbus 3 radiation data

To improve the specification of stratospheric, horizontal, temperature and geopotential height fields needed for high-flying aircraft, we derived a technique to estimate data between satellite tracks using interpolated infrared interferometer spectrometer 15-micron radiation data from Nimbus 3. The interpolation is based on the observed gradients of the medium resolution infrared 15-micron radiances between subsatellite tracks. The technique was verified with radiosonde data taken within 6 hr of the satellite data. Comparison indicates that the technique developed here produces analyses that are in general agreement with those from radiosonde data. In addition, this technique provides details over areas of sparse data not shown by conventional techniques.

Nicholas, G. W.↗

Comparison of column water vapor measurements using downward-looking near-infrared and infrared imaging systems and upward-looking microwave radiometers

Remote soundings of precipitable water vapor from three systems are compared with each other and with ground truth from radiosondes. Ancillary data from a mesoscale network of surface observing stations and from wind-profiling radars are also used in the analysis. The three remote-sounding techniques are: (a) a reflectance technique using spectral data collected by the Airborne Visible-Infrared Imaging Spectrometer; (b) an emission technique using Visible-Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) data acquired from the NOAA's GOES; and (c) a microwave technique using data from a limited network of three ground-based dual-channel microwave radiometers. The data were taken over the Front Range of eastern Colorado on 22-23 March 1990. The generally small differences between the three types of remote-sounding measurements are consistent with the horizontal and temporal resolutions of the instruments. The microwave and optical reflectance measurements agreed to within 0.1 cm; comparisons of the microwave data with radiosondes were also either as good or explainable. The largest differences between the VAS and the microwave radiometer at Elbert were between 0.4 and 0.5 cm and appear to be due to variable terrain within the satellite footprint.

Gao, Bo-Cai↗

Nighttime Cirrus Detection using Atmospheric Infrared Sounder Window Channels and Total Column Water Vapor

A method of cirrus detection at nighttime is presented that utilizes 3.8 and 10.4 (micro)m infrared (IR) window brightness temperature differences (dBT) and total column precipitable water (PW) measurements. This technique is applied to the Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Sounding Unit A (AMSU-A) instrument suite on board EOS-Aqua, where dBT is determined from sets of carefully selected AIRS window channels, while PW is derived from the synergistic AIRS and AMSU-A water vapor retrievals. Simulated and observed dBT for a particular value of PW are not constant; several physical factors impact dBT, including the variability in temperature and relative humidity profiles, surface emissivity, instrument noise, and skin/ near-surface air temperature differences. We simulate clear-sky dBT over a realistic range of PWs using 8350 radiosondes that have varying temperature and relative humidity profiles. Thresholds between cloudy and uncertain sky conditions are derived once the scatter in the clear-sky dBT is determined. Simulations of optically thin cirrus indicate that this technique is most sensitive to cirrus optical depth in the 10 (micro)m window of 0.1-0.15 or greater over the tropical and subtropical oceans, where surface emissivity and skin/near-surface air temperature impacts on the IR radiances are minimal. The method at present is generally valid over oceanic regions only, specifically, the tropics and subtropics. The detection of thin cirrus, and other cloud types, is validated using observations at the Atmospheric Radiation Measurement (ARM) program site located at Manus Island in the tropical western Pacific for 89 coincident EOS-Aqua overpasses. Even though the emphasis of this work is on the detection of thin cirrus at nighttime, this technique is sensitive to a broad cloud morphology. The cloud detection technique agrees with ARM-detected clouds 82-84% of the time, which include thin cirrus, as well as other cloud types. Most of the disagreements are well explained by AIRS footprint-scale heterogeneity compared to ARM point measurements, cirrus overlying lower-layer water clouds, possible mixed phase microphysics in midlevel clouds, and significant IR channel noise for cold BT scenes over deep convective towers.

Atmospheric Radiation Measurement (RAM)↗

Infrared Imaging Of Flows Seeded With SF6

Novel technique enables repeated measurements of flow patterns during flight. Wing-tip vorticity studied in flight by observing infrared emissions from SF6 gas entrained in wing-tip flow. System makes vortical flows visible throughout all altitude and speed ranges of all subsonic aircraft. Also useful for transonic and supersonic speeds. Primary application is testing of aircraft in flight, also proves useful in testing fast land vehicles and structures or devices subject to strong winds.

Manuel, Gregory S.↗

High Resolution Spectroscopy to Support Atmospheric Measurements

Spectroscopic parameters (such as line position, intensity, broadening and shifting coefficients and their temperature dependences, line mixing coefficients etc.) for various molecular species of atmospheric interest are determined. In order to achieve these results, infrared spectra of several molecular bands are obtained using high-resolution recording instruments such as tunable diode laser spectrometer and Fourier transform spectrometers. Using sophisticated analysis routines (Multispectrum nonlinear least squares technique) these high-resolution infrared spectra are processed to determine the various spectral line parameters that are cited above. Spectra were taken using the McMath-Pierce Fourier transform spectrometer (FTS) at the National Solar Observatory on Kitt Peak, Arizona as well as the Bruker FTS at the Pacific Northwest National Laboratory (PNNL) at Richland, Washington. Most of the spectra are acquired not only at room temperature, but also at several different cold temperatures. This procedure is necessary to study the variation of the spectral line parameters as a function of temperature in order to simulate the Earth's and other planetary atmospheric environments. Depending upon the strength or weakness of the various bands recorded and analyzed, the length(s) of the absorption cells in which the gas samples under study are kept varied from a few centimeters up to several meters and the sample temperatures varied from approximately +30 C to -63 C. Research on several infrared bands of various molecular species and their isotopomers are undertaken. Those studies are briefly described.

Venkataraman, Malathy Devi↗

Infrared line parameters at low temperatures relevant to planetary atmospheres

Employing the techniques that were described in several publications for measuring infrared lineshifts, linewidths and line intensities with a tunable diode laser, these parameters were measures for lines in the important infrared bands of several molecules of interest to the planetary astronomer at low temperatures that are relevant to planetary atmospheres using He, Ne, Ar, H2, N2, O2, and air as the perturbers. In addition to obtaining the many original data on the temperature dependence of the intensities and linewidths, it was also the first measurement of the same for the collision-induced lineshift of an infrared line and it showed that it was markedly different from that of the corresponding collision-broadened linewidth.

Varanasi, Prasad↗

Decomposition of NO studied by infrared emission and CO laser absorption

A diagnostic technique for monitoring the concentration of NO using absorption of CO laser radiation was developed and applied in a study of the decomposition kinetics of NO. Simultaneous measurements of infrared emission by NO at 5.3 microns were also made to validate the laser absorption technique. The data were obtained behind incident shocks in NO-N2O-Ar (or Kr) mixtures, with temperatures in the range 2400-4100 K. Rate constants for dominant reactions were inferred from comparisons with computer simulations of the reactive flow.

Hanson, R. K.↗

Infrared absorption spectroscopy of dynamically compressed water

Presentation describes development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decomposition of NO studied by infrared emission and CO laser absorption

A diagnostic technique for monitoring the concentration of NO using absorption of CO laser radiation has been developed and applied in a study of the decomposition kinetics of NO. Simultaneous measurements of infrared emission by NO at 5.3 microns were also made to validate the laser absorption technique. The data were obtained behind incident shocks in NO-N2O-Ar (or Kr) mixtures, with temperatures in the range 2400-4100 K. The rate constant for the dominant reaction of O and NO to yield N and O2 was inferred from comparisons with computer simulations of the reactive flow.

Hanson, R. K.↗

Science with High Spatial Resolution Far-Infrared Data

The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

Terebey, Susan↗

Assessment of a Technique for Estimating Total Column Water Vapor Using Measurements of the Infrared Sky Temperature

A method for estimating the integrated precipitable water (IPW) content of the atmosphere using measurements of indicated infrared zenith sky temperature was validated over east-central Florida. The method uses inexpensive, commercial off the shelf, hand-held infrared thermometers (IRT). Two such IRTs were obtained from a commercial vendor, calibrated against several laboratory reference sources at KSC, and used to make IR zenith sky temperature measurements in the vicinity of KSC and Cape Canaveral Air Force Station (CCAFS). The calibration and comparison data showed that these inexpensive IRTs provided reliable, stable IR temperature measurements that were well correlated with the NOAA IPW observations.

integrated precipitable water (IPW)↗

Method for conducting in situ high-temperature digital image correlation with simultaneous synchrotron measurements under thermomechanical conditions

This work presents a novel method of obtaining in situ strain measurements at high temperature by simultaneous digital image correlation (DIC), which provides the total strain on the specimen surface, and synchrotron x-ray diffraction (XRD), which provides lattice strains of crystalline materials. DIC at high temperature requires specialized techniques to overcome the effects of increased blackbody radiation that would otherwise overexpose the images. The technique presented herein is unique in that it can be used with a sample enclosed in an infrared heater, remotely and simultaneously with synchrotron XRD measurements. The heater included a window for camera access, and the light of the heater lamps is used as illumination. High-temperature paint is used to apply a random speckle pattern to the sample to allow the tracking of displacements and the calculation of the DIC strains. An inexpensive blue theatrical gel filter is used to block interfering visible and infrared light at high temperatures. This technique successfully produces properly exposed images at 870 °C and is expected to perform similarly at higher temperatures. The average strains measured by DIC were validated by an analytical calculation of the theoretical strain. Simultaneous DIC and XRD strain measurements of Inconel 718 (IN718) tensile test specimens were performed under thermal and mechanical loads and evaluated. Finally, this approach uses the fact that with DIC, the total strain is measured, including plastic strain, while with XRD, only elastic strain is captured. The observed differences were discussed with respect to the effective deformation mechanisms.

47 OTHER INSTRUMENTATION↗

Fourier transform infrared and Raman spectroscopic characterization of homogeneous solution concentration gradients near a container wall at different temperatures

Fourier transform infrared (FTIR) and Raman spectroscopic techniques were used to study the solution concentration gradient in succino nitrile-rich and water-rich homogeneous solutions. The spectroscopic data shows significant concentration dependency. Although FTIR-attenuated total reflectance could not yield surface spectra since the evanescent infrared wave penetrated deep into the bulk solution, it showed that water-rich clusters were decreased at higher temperatures. This result is consistent with the calorimetric results reported earlier.

Loo, B. H.↗

High Resolution Infrared Spectroscopy of Highly Reactive Chemical Intermediates: Berkeley Inspiration and a C.B. Moore Retrospective

One of the long-standing paradoxes in chemistry is that the molecular species of greatest interest are often highly reactive chemical intermediates and thus present only at vanishingly small concentrations under typical steady state conditions. Here, this has proven both a key frustration and powerful motivation for physical chemists in probing such species, particularly for high resolution laser spectroscopic methods in the infrared. Over the past 4-5 decades, this fundamental sensitivity challenge has stimulated the development of many novel techniques for efficient generation, cooling, and infrared probing of such transient chemical intermediates, achieving increasingly sophisticated levels of spectroscopic detail, chemical insight, and a testbed for comparison with first principles ab initio quantum calculations. Two of the pioneering contributors to this scientific arena have been George Pimentel and C. Bradley Moore, both responsible for nourishing DJN’s own enduring fascination with spectroscopic IR study of elusive chemical intermediates. This chapter is not intended to provide a comprehensive review of this large and enormously successful field, but it rather more simply attempts to capture a few selective “Moore-centric” snapshots of the Nesbitt group scientific evolution, specifically in i) advances by Pimentel for the original development of rapid scan flash kinetic spectroscopy based on spectrometers with rapidly rotating IR gratings, ii) the modernization/extension of these methods in the Moore group toward the first high resolution IR laser spectroscopy of singlet/triplet methylene 1,3 CH 2 diradical, and finally to iii) the development of slit supersonic discharge expansion methods at JILA for sub-Doppler infrared laser study of multiple radicals, jet cooled molecular ions, and highly reactive chemical intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

Multi-Spectral Cloud Property Retrieval

Despite numerous studies to retrieve cloud properties using infrared measurements the information content of the data has not yet been fully exploited. In an effort to more fully utilize the information content of infrared measurements, we have developed a multi-spectral technique for retrieving effective cloud particle size, optical depth and effective cloud temperature. While applicable to all cloud types, we begin by validating our retrieval technique through analysis of MS spectral radiances obtained during the SUCCESS field campaign over the ARM SGP CART facility, and compare our retrieval product with lidar and MODIS Airborne Simulator (MAS) measurement results. The technique is then applied to the Nimbus-4 MS infrared spectral measurements to obtain global cloud information.

Carlson, Barbara E.↗