Thermal Stability of Quasi-1D NbS 3 Nanoribbons and Their Transformation to 2D NbS 2 : Insights from in Situ Electron Microscopy and Spectroscopy

Here in situ electron microscopy imaging and spectroscopy enabled us to study the evolution of quasi-1D NbS 3 -IV nanoribbons with respect to morphology and chemical structure at temperatures between room temperature and 1000 °C. Scanning transmission electron microscopy (STEM) experiments included imaging in the secondary electron, (transmitted) bright field, and high-angle annular dark-field modes while operating in the low kV regime. The results showed that NbS 3 -IV samples transform dramatically from smooth nanoribbons into highly textured configurations featuring polyhedral divots and steps. Similar in situ heating experiments conducted with aberration-corrected STEM revealed that bilayers of NbS 3 -IV chains convert topotactically into aligned 2H-NbS 2 sheets upon loss of sulfur. Atomic resolution imaging, fast Fourier transform analysis, and electron energy loss spectroscopy confirmed these chemical changes, from which we propose an atomistic mechanism for the NbS 3 -IV → 2H-NbS 2 conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wavelength-precise slit spectroscopy with optical fiber image scramblers

The application of optical-fiber image scramblers in wavelength-precise slit spectroscopy is discussed together with the design strategy for the optimal instrument configuration incorporating an optical-fiber image scrambler. Particular attention is given to the aspects of data analysis and interpretation techniques which must be specially designed for high-precision spectroscopy. In a specific application to an existing coude spectrograph, the instrumentation and data reduction techniques described in this paper demonstrate an achievable precision corresponding to a systematic radial velocity error of about 30 m/sec.

Heacox, William D.↗

Self-scanned Digicon - A digital image tube for astronomical spectroscopy

We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.

Tull, R. G.↗

Photodetachment spectroscopy and resonant photoelectron imaging of cryogenically cooled 1-pyrenolate

We report an investigation of the 1-pyrenolate anion (PyO - ) and the 1-pyrenoxy radical (PyO) using photodetachment spectroscopy and resonant photoelectron imaging of cryogenically-cooled anions. The electron affinity of PyO is measured to be 2.4772(4) eV (19,980 ± 3 cm -1 ) from high-resolution photoelectron spectroscopy. Photodetachment spectroscopy reveals a dipole-bound state (DBS) for PyO - 280 cm-1 below the detachment threshold, as well as a broad and intense valence excited state (shape resonance) 1,077 cm-1 above the detachment threshold. The shape resonance with an excitation energy of 21,055 cm -1 is due to excitation of an electron from the highest occupied molecular orbital of PyO - to its lowest unoccupied molecular orbital in the continuum. Twenty-nine vibrational levels of the DBS are observed, including twenty-seven above-threshold vibrational levels (vibrational Feshbach resonances). Twenty-seven resonant photoelectron spectra are obtained by tuning the detachment laser to the vibrational Feshbach resonances, resulting in highly non-Franck-Condon photoelectron spectra and rich vibrational information. In total, the frequencies of twenty-one vibrational modes are obtained for the PyO radical by the combination of the photodetachment and resonant photoelectron spectroscopy, including thirteen out-of-plane bending modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photodetachment spectroscopy and resonant photoelectron imaging of the 2-naphthoxide anion via dipole-bound excited states

We report a photodetachment spectroscopy and high-resolution resonant photoelectron imaging study of cryogenically-cooled 2-naphthoxide anions (C 10 H 7 O - ). The photodetachment spectrum revealed a dipole-bound state (DBS) 202(4) cm -1 below the detachment threshold and thirty-eight resonances corresponding to the vibrational levels of the DBS. By tuning the detachment laser to these above-threshold resonances, we obtained thirty-eight resonantly-enhanced photoelectron spectra, which were highly non-Franck-Condon as a result of mode-selective vibrational auto-detachment from the DBS. The resonances were assigned by comparing the resonant and non-resonant photoelectron spectra, assisted by the computed vibrational frequencies. Specifically, vibrational features with low Franck-Condon factors or from Franck-Condon-forbidden vibrational modes were significantly enhanced in the resonant photoelectron spectra, resulting in much richer spectroscopic information. The electron affinity of the 2-naphthoxy radical was measured accurately to be 19,387(4) cm -1 or 2.4037(5) eV. In addition, a total of seventeen vibrational frequencies were obtained for the 2-naphthoxy radical. In particular, seven Franck-Condon-forbidden out-of-plane bending modes, including the two lowest frequency modes (ν 48 at 102 cm -1 and ν47 at 171 cm -1 ), were observed, demonstrating the advantages of combining photodetachment spectroscopy and resonant photoelectron spectroscopy in obtaining vibrational information for polar radical species via DBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the redistribution of charge in La 0.7 Sr 0.3 CrO 3 /La 0.7 Sr 0.3 MnO 3 multilayer thin films

The atomic and electronic structures of La 0.7 Sr 0.3 MnO 3 (LSMO)/La 0.7 Sr 0.3 CrO 3 (LSCO) multilayer thin films are investigated using aberration corrected scanning transmission electron microscopy (STEM) imaging and spectroscopy. Atomic resolution high angle annular dark-field reveals that LSMO layers have an expanded out-of-plane lattice parameter compared to compressed LSCO layers, contrasting with x-ray diffraction measurements. The expansion is found to result from preferential oxygen vacancy formation in LSMO during STEM sample preparation as determined by electron energy-loss spectroscopy. The La/Sr atom column intensity is also found to oscillate by about 4% between the LSMO and LSCO layers, indicative of La/Sr concentration variation. Using energy-dispersive x-ray spectroscopy in combination with image simulations, we confirm the La/Sr inhomogeneity and elucidate the origin of charge redistribution within the multilayer. These results illuminate the sensitivity of the technique to subtle structural, chemical, and electronic features that can arise to compensate charge imbalances in complex oxide heterostructures.

36 MATERIALS SCIENCE↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗

Ultrafast method for scanning tunneling spectroscopy

A scanning tunneling microscope (STM) combines unique capabilities in imaging and spectroscopy with atomic precision, and it can obtain energy-resolved spectroscopic data with atomic resolution. In this paper, we utilize a recently proposed modification to the STM feedback control loop to acquire high quality d 2 I/dV 2 images. We have developed a constant differential conductance imaging method by closing the STM feedback loop with a high precision dI/dV measurement. In this mode, the tip’s vertical position is adjusted so as to keep the differential conductance constant during raster scanning of the surface. Based on this imaging mode, we propose a new technique to acquire fast and reliable scanning tunneling spectroscopy (STS) data simultaneously with the imaging.

47 OTHER INSTRUMENTATION↗

RapidEELS: machine learning for denoising and classification in rapid acquisition electron energy loss spectroscopy

Recent advances in detectors for imaging and spectroscopy have afforded in situ, rapid acquisition of hyperspectral data. While electron energy loss spectroscopy (EELS) data acquisition speeds with electron counting are regularly reaching 400 frames per second with near-zero read noise, signal to noise ratio (SNR) remains a challenge owing to fundamental counting statistics. In order to advance understanding of transient materials phenomena during rapid acquisition EELS, trustworthy analysis of noisy spectra must be demonstrated. In this study, we applied machine learning techniques to denoise high frame rate spectra, benchmarking with slower frame rate “ground truths”. The results provide a foundation for reliable use of low SNR data acquired in rapid, in-situ spectroscopy experiments. Such a tool-set is a first step toward both automation in microscopy as well as use of these methods to interrogate otherwise poorly understood transformations.

36 MATERIALS SCIENCE↗

Applications of ultrafast nano-spectroscopy and nano-imaging with tip-based microscopy

Innovation in microscopy has often been critical in advancing both fundamental science and technological progress. Notably, the evolution of ultrafast near-field optical nano-spectroscopy and nano-imaging has unlocked the ability to image at spatial scales from nanometers to ångströms and temporal scales from nanoseconds to femtoseconds. This approach revealed a plethora of fascinating light-matter states and quantum phenomena, including various species of polaritons, quantum phases, and complex many-body effects. This review focuses on the working principles and state-of-the-art development of ultrafast tip-enhanced and near-field microscopy, integrating diverse optical pump-probe methods across the terahertz (THz) to ultraviolet (UV) spectral ranges. It highlights their utility in examining a broad range of materials, including two-dimensional (2D), organic molecular, and hybrid materials. The review concludes with a spatio-spectral-temporal comparison of ultrafast nano-imaging techniques, both within already well-defined domains, and offering an outlook on future developments of ultrafast tip-based microscopy and their potential to address a wider range of materials.

Zhao, Zhichen [Tongji University, Shanghai (China)↗

On the application of optical-fiber image scramblers to astronomical spectroscopy

Single, step-index optical fibers, when properly employed, can function as optically efficient image scramblers. Their use as optical feeds for astronomical slit spectrographs can reduce zonal error levels in those instruments by orders of magnitude. As a consequence, the application of optical-fiber couplers to new and existing spectrographs may greatly increase the wavelength metric quality of conventional astronomical spectroscopy. The optical efficiencies of fiber couplers of a few tens of meters in length can be comparable to those of typical coude mirror trains in the visible portions of the spectrum. Elements of the design of fiber couplers are illustrated by discussion of a currently operational instrument.

Heacox, W. D.↗

In planta single-molecule imaging and holographic force spectroscopy to study real-time, multimodal turnover dynamics of polysaccharides and associated carbohydrate metabolites

Cellular production of polysaccharides from simple sugar molecules serves critical roles in a variety of metabolic processes essential to the survival of every living organism. In the context of photosynthetically fixed carbon, cell wall polysaccharides synthesis is particularly of interest for increased biomass accumulation for human food, animal feed, and bioenergy related applications. Despite a long history of research in plant cell biology, our understanding of in planta cell wall biosynthesis and its regulation is far from complete due to lack of a comprehensive microscopy toolkit that encompass the multiple spatial and temporal scales in which cell wall polysaccharides fibrils are synthesized and assembled into intricate cell wall networks. In this project, a multidisciplinary team of scientists from Rutgers University, Vanderbilt University, and Oak Ridge National Laboratory carried out innovative multimodal, multiscale microscopy studies of cell wall synthesis using single-molecule force-spectroscopy, super-resolution fluorescence microscopy, and in vivo live cell imaging. Our novel multimodal and holistic imaging approach revealed plant cell wall polysaccharides synthesis processes in unprecedented detail across multiple spatiotemporal scales, from a single-molecule to a single-cell. Besides, the team has made technical and scientific innovations across multiple research fields—microscopy, bioengineering, single-molecule biophysics, and plant biology, etc.—to accomplish the goals. The results from this project will greatly advance the mechanistic and holistic understanding of in planta cell wall synthesis, which will accelerate the development of better transgenic crops for bioenergy applications. Moreover, the new toolbox, combining powerful advanced microscopy assays with cell/protein engineering, will have broader impacts on molecular and cellular biology fields by paving the way for studying cellular processes occurring across multiple physical scales with multimodal microscopy methodologies.

59 BASIC BIOLOGICAL SCIENCES↗

Nancy Grace Roman Space Telescope Observatory Implementation and Challenges

NASA’s Nancy Grace Roman Space Telescope (Roman) is a deep space infrared observatory with a Hubble-sized telescope and wide field of regard with a boresight view greater than 200 times that of the Hubble Wide Field Camera 3infrared field of view, that will conduct a suite of science surveys to characterize dark energy and expand the census of exoplanets in our galaxy. Roman will also demonstrate exoplanet coronagraphy with active wavefront control technology and provide general investigator opportunities for the science community. Roman is finishing the critical design phase and is planning for launch in 2026. It will operate at the second Sun-Earth-Moon Lagrange for a five-year primary mission life. The Observatory features a telescope with an existing, repurposed 2.4m primary mirror, a Wide Field Instrument with a near-infrared detector focal plane array and optical elements for imaging and spectroscopy, as well as a Coronagraph instrument technology demonstration for direct imaging and spectroscopy of exoplanets. The telescope and instruments are mounted to an Instrument Carrier for optical metering and isolation from Spacecraft-induced disturbances. The Spacecraft includes a Bus, Solar Array Sunshield, Deployable Aperture Cover, Outer Barrel Assembly, and Star Tracker/Inertial Reference Unit Bench. When fully integrated, Roman will be the largest Observatory assembled and tested at NASA’s Goddard Space Flight Center. The development of scientific satellites is challenging and pushes engineering boundaries to broaden scientific knowledge. The Roman mission implementation is a prime example and expected challenges have been amplified by the foundational decision to use existing, repurposed telescope components. Other unique aspects of the Roman mission, including its survey nature, large data volume, and Observatory packaging, create constrained design spaces that drive competing requirements across Observatory subsystems. Given these challenges, systems engineering has been a critical discipline in balancing implementation decisions and will continue to play a key role in the development of the Roman mission. This paper will discuss details of the Roman Observatory configuration, systems engineering challenges and the decision-making process used to mature the Roman Space Telescope from preliminary design to implementation.

Lisa M L Bartusek↗

High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2 deg becomes practical by combining position-sensitive germanium detectors having a segment thickness of a few millimeters with a one-dimensional coded aperture located about a meter from the detectors. Correspondingly higher angular resolutions are possible with larger separations between the detectors and the coded aperture. Two-dimensional images can be obtained by rotating the instrument. Although the basic concept is similar to optical or X-ray coded-aperture imaging techniques, several complicating effects arise because of the penetrating nature of gamma rays. The complications include partial transmission through the coded aperture elements, Compton scattering in the germanium detectors, and high background count rates. Extensive electron-photon Monte Carlo modeling of a realistic detector/coded-aperture/collimator system has been performed. Results show that these complicating effects can be characterized and accounted for with no significant loss in instrument sensitivity.

Callas, J. L.↗

Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

Mungas, Greg S.↗

Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

Mungas, Greg S.↗