Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Online monitoring of oil film using electrical capacitance tomography and level set method

In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-09: The Impact of X-Ray Scattering On Image Noise for Dedicated Breast CT

Purpose: To quantify the impact of detected x-ray scatter on image noise in flat panel based dedicated breast CT systems and to determine the optimal scanning geometry given practical trade-offs between radiation dose and scatter reduction. Methods: Four different uniform polyethylene cylinders (104, 131, 156, and 184 mm in diameter) were scanned as the phantoms on a dedicated breast CT scanner developed in our laboratory. Both stationary projection imaging and rotational cone-beam CT imaging was performed. For each acquisition type, three different x-ray beam collimations were used (12, 24, and 109 mm measured at isocenter). The aim was to quantify image noise properties (pixel variance, SNR, and image NPS) under different levels of x-ray scatter, in order to optimize the scanning geometry. For both projection images and reconstructed CT images, individual pixel variance and NPS were determined and compared. Noise measurement from the CT images were also performed with different detector binning modes and reconstruction matrix sizes. Noise propagation was also tracked throughout the intermediate steps of cone-beam CT reconstruction, including the inverse-logarithmic process, Fourier-filtering before backprojection. Results: Image noise was lower in the presence of higher scatter levels. For the 184 mm polyethylene phantom, the image noise (measured in pixel variance) was ∼30% lower with full cone-beam acquisition compared to a narrow (12 mm) fan-beam acquisition. This trend is consistent across all phantom sizes and throughout all steps of CT image reconstruction. Conclusion: From purely a noise perspective, the cone-beam geometry (i.e. the full cone-angle acquisition) produces lower image noise compared to the lower-scatter fan-beam acquisition for breast CT. While these results are relevant in homogeneous phantoms, the full impact of scatter on noise in bCT should involve contrast-to-noise-ratio measurements in heterogeneous phantoms if the goal is to optimize the scanning geometry for dedicated breast CT. This work was supported by a grant from the National Institute for Biomedical Imaging and Bioengineering (R01 EB002138)

60 APPLIED LIFE SCIENCES↗

SU-E-J-29: Automatic Image Registration Performance of Three IGRT Systems for Prostate Radiotherapy

Purpose: To compare the performance of an automatic image registration algorithm on image sets collected on three commercial image guidance systems, and explore its relationship with imaging parameters such as dose and sharpness. Methods: Images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on the CBCT systems of Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings; and MVCT on a Tomotherapy Hi-ART accelerator with a range of pitch. Using the 6D correlation ratio algorithm of XVI, each image was registered to a mask of the prostate volume with a 5 mm expansion. Registrations were repeated 100 times, with random initial offsets introduced to simulate daily matching. Residual registration errors were calculated by correcting for the initial phantom set-up error. Automatic registration was also repeated after reconstructing images with different sharpness filters. Results: All three systems showed good registration performance, with residual translations <0.5mm (1σ) for typical clinical dose and reconstruction settings. Residual rotational error had larger range, with 0.8°, 1.2° and 1.9° for 1σ in XVI, OBI and Tomotherapy respectively. The registration accuracy of XVI images showed a strong dependence on imaging dose, particularly below 4mGy. No evidence of reduced performance was observed at the lowest dose settings for OBI and Tomotherapy, but these were above 4mGy. Registration failures (maximum target registration error > 3.6 mm on the surface of a 30mm sphere) occurred in 5% to 10% of registrations. Changing the sharpness of image reconstruction had no significant effect on registration performance. Conclusions: Using the present automatic image registration algorithm, all IGRT systems tested provided satisfactory registrations for clinical use, within a normal range of acquisition settings.

60 APPLIED LIFE SCIENCES↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Classification procedure in limited angle tomography system

In this work we propose the use of limited angle reconstruction algorithms combined with a procedure for defect detection and feature evaluation in three dimensions. The procedure consists of the following steps: acquisition of the X-ray projections, approximated limited angle 3D image reconstruction, and image preprocessing and classification.

07 ISOTOPE AND RADIATION SOURCES↗

An improved back projection algorithm of ultrasound tomography

Binary logic back projection algorithm is improved in this work for the development of fast ultrasound tomography system with a better effect of image reconstruction. The new algorithm is characterized by an extra logical value ‘2’ and dual-threshold processing of collected raw data. To compare with the original algorithm, a numerical simulation was conducted by the verification of COMSOL simulations formerly, and then a set of ultrasonic tomography system is established to perform the experiments of one, two and three cylindrical objects. The object images are reconstructed through the inversion of signals matrix acquired by the transducer array after a preconditioning, while the corresponding spatial imaging errors can obviously indicate that the improved back projection method can achieve modified inversion effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-F-18C-02: Increasing Amorphous Selenium Thickness in Direct Conversion Flat-Panel Imagers for Contrast-Enhanced Dual-Energy Breast Imaging

Purpose: Contrast-enhanced (CE) breast imaging using iodinated contrast agents requires imaging with x-ray spectra at energies greater than those used in mammography. Optimizing amorphous selenium (a-Se) flat panel imagers (FPI) for this higher energy range may increase lesion conspicuity. Methods: We compare imaging performance of a conventional FPI with 200 μm a-Se conversion layer to a prototype FPI with 300 μm a-Se layer. Both detectors are evaluated in a Siemens MAMMOMAT Inspiration prototype digital breast tomosynthesis (DBT) system using low-energy (W/Rh 28 kVp) and high-energy (W/Cu 49 kVp) x-ray spectra. Detectability of iodinated lesions in dual-energy images is evaluated using an iodine contrast phantom. Effects of beam obliquity are investigated in projection and reconstructed images using different reconstruction methods. The ideal observer signal-to-noise ratio is used as a figure-of-merit to predict the optimal a-Se thickness for CE lesion detectability without compromising conventional full-field digital mammography (FFDM) and DBT performance. Results: Increasing a-Se thickness from 200 μm to 300 μm preserves imaging performance at typical mammographic energies (e.g. W/Rh 28 kVp), and improves the detective quantum efficiency (DQE) for high energy (W/Cu 49 kVp) by 30%. While the more penetrating high-energy x-ray photons increase geometric blur due to beam obliquity in the FPI with thicker a-Se layer, the effect on lesion detectability in FBP reconstructions is negligible due to the reconstruction filters employed. Ideal observer SNR for CE objects shows improvements in in-plane detectability with increasing a-Se thicknesses, though small lesion detectability begins to degrade in oblique projections for a-Se thickness above 500 μm. Conclusion: Increasing a-Se thickness in direct conversion FPI from 200 μm to 300 μm improves lesion detectability in CE breast imaging with virtually no cost to conventional FFDM and DBT. This work was partially supported by a research grant from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of exit beam phase aberrations on parallel beam coherent x-ray reconstructions

Diffraction artifacts from imperfect x-ray windows near the sample are an important consideration in the design of coherent x-ray diffraction measurements. In this study, we used simulated and experimental diffraction patterns in two and three dimensions to explore the effect of phase imperfections in a beryllium window (such as a void or inclusion) on the convergence behavior of phasing algorithms and on the ultimate reconstruction. A predictive relationship between beam wavelength, sample size, and window position was derived to explain the dependence of reconstruction quality on beryllium defect size. Defects corresponding to this prediction cause the most damage to the sample exit wave and induce signature error oscillations during phasing that can be used as a fingerprint of experimental x-ray window artifacts. The relationship between x-ray window imperfection size and coherent x-ray diffractive imaging reconstruction quality explored in this work can play an important role in designing high-resolution in situ coherent imaging instrumentation and will help interpret the phasing behavior of coherent diffraction measured in these in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of a space-station-associated multiple spacecraft Michelson spatial interferometer

One approach to Michelson spatial interferometry at optical wavelengths involves use of an array of spacecraft in which two widely-separated telescopes collect light from a star and direct it to a third, centrally-located, device which combines the beams in order to detect and measure interference fringes. The original version of a spacecraft array for Michelson spatial interferometry (SAMSI) was modified so that the system uses the fuel resupply capability of a space station. The combination of this fuel resupply capability with a method of obtaining image Fourier transform phase information, necessary for full image reconstruction, permits SAMSI to be used to synthesize images equivalent to those produced by huge apertures in space. Synthesis of apertures in the 100 to 500 meter range is discussed. Reconstruction can be performed to a visual magnitude of at least 8 for a 100 A passband in 9 hours. Data are simultaneously collected for image generation from 0.1 micron to 18 microns. In the one-dimensional mode, measurements can be made every 90 minutes (including acquisition and repointing time) for objects as faint as 19th magnitude in the visible.

Stachnik, R. V.↗

SU-E-J-215: Onboard Split PET Including the Effects of Attenuation, Scatter, and Random Events

Purpose: Positron emission tomography (PET) using split PET geometry was investigated as an on-board system for functional imaging and PET marker tracking, specifically with tomotherapy. The open dual ring PET would allow measurement of both inter and intra-fractional variation, improving the delineation of tumor volume at any stage in the radiation treatment delivery process. We present results from data obtained using Monte Carlo simulations including the effects of attenuation, random events, and scatter. Methods: PET design was accomplished via Monte Carlo simulations with GATE, the Geant4 Application for Emission Tomography. Images were reconstructed using Software for Image Reconstruction (STIR) with a fully 3D ordered subset expectation maximization (OSEM) image reconstruction technique. Results: Monte Carlo simulations of the split PET geometry indicate that including physical factors that degrade image quality such as attenuation, random events, and scatter still prove the feasibility of near real-time PET for both inter and intra-fractional radiation delivery. The image quality of scan times under 1 minute reveals that it is possible to utilize PET scanning and reconstruction during the treatment session intrafractionally. GATE also simulates the depth information but does not correct obliqueness of the path of line of response so the data is much more realistic than the data obtained with ray tracing. Conclusion: Onboard split PET with TomoTherapy can generate quality images under 1 minute scan times without the need to correct for attenuation, scatter, random events, or depth information of the interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image segmentation of nanoscale Zernike phase contrast X-ray computed tomography images

Zernike phase contrast is a useful technique for nanoscale X-ray computed tomography (CT) imaging of materials with a low X-ray absorption coefficient. It enhances the image contrast by phase shifting X-ray waves to create changes in amplitude. However, it creates artifacts that hinder the use of traditional image segmentation techniques. We propose an image restoration method that models the X-ray phase contrast optics and the three-dimensional image reconstruction method. We generate artifact-free images through an optimization problem that inverts this model. Though similar approaches have been used for Zernike phase contrast in visible light microscopy, this optimization employs an effective edge detection method tailored to handle Zernike phase contrast artifacts. We characterize this optics-based restoration method by removing the artifacts in and thresholding multiple Zernike phase contrast X-ray CT images to produce segmented results that are consistent with the physical specimens. We quantitatively evaluate and compare our method to other segmentation techniques to demonstrate its high accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Provable Convergence of Plug-and-Play Priors With MMSE Denoisers

Plug-and-play priors (PnP) is a methodology for regularized image reconstruction that specifies the prior through an image denoiser. While PnP algorithms are well understood for denoisers performing maximum a posteriori probability (MAP) estimation, they have not been analyzed for the minimum mean squared error (MMSE) denoisers. Here we address this gap by establishing the first theoretical convergence result for the iterative shrinkage/thresholding algorithm (ISTA) variant of PnP for MMSE denoisers. We show that the iterates produced by PnP-ISTA with an MMSE denoiser converge to a stationary point of some global cost function. We validate our analysis on sparse signal recovery in compressive sensing by comparing two types of denoisers, namely the exact MMSE denoiser and the approximate MMSE denoiser obtained by training a deep neural net.

97 MATHEMATICS AND COMPUTING↗

Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT

Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.

Encarnação, Pedro M C C↗

Astronomical data analysis software and systems I; Proceedings of the 1st Annual Conference, Tucson, AZ, Nov. 6-8, 1991

Consideration is given to a definition of a distribution format for X-ray data, the Einstein on-line system, the NASA/IPAC extragalactic database, COBE astronomical databases, Cosmic Background Explorer astronomical databases, the ADAM software environment, the Groningen Image Processing System, search for a common data model for astronomical data analysis systems, deconvolution for real and synthetic apertures, pitfalls in image reconstruction, a direct method for spectral and image restoration, and a discription of a Poisson imagery super resolution algorithm. Also discussed are multivariate statistics on HI and IRAS images, a faint object classification using neural networks, a matched filter for improving SNR of radio maps, automated aperture photometry of CCD images, interactive graphics interpreter, the ROSAT extreme ultra-violet sky survey, a quantitative study of optimal extraction, an automated analysis of spectra, applications of synthetic photometry, an algorithm for extra-solar planet system detection and data reduction facilities for the William Herschel telescope.

Worrall, Diana M.↗

Lossless compression of AVIRIS data: Comparison of methods and instrument constraints

A family of lossless compression methods, allowing exact image reconstruction, are evaluated for compressing Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) image data. The methods are used on Differential Pulse Code Modulation (DPCM). The compressed data have an entropy of order 6 bits/pixel. A theoretical model indicates that significantly better lossless compression is unlikely to be achieved because of limits caused by the noise in the AVIRIS channels. AVIRIS data differ from data produced by other visible/near-infrared sensors, such as LANDSAT-TM or SPOT, in several ways. Firstly, the data are recorded at a greater resolution (12 bits, though packed into 16-bit words). Secondly, the spectral channels are relatively narrow and provide continuous coverage of the spectrum so that the data in adjacent channels are generally highly correlated. Thirdly, the noise characteristics of the AVIRIS are defined by the channels' Noise Equivalent Radiances (NER's), and these NER's show that, at some wavelengths, the least significant 5 or 6 bits of data are essentially noise.

Roger, R. E.↗

UPRE method for total variation parameter selection

Total Variation (TV) Regularization is an important method for solving a wide variety of inverse problems in image processing. In order to optimize the reconstructed image, it is important to choose the optimal regularization parameter. The Unbiased Predictive Risk Estimator (UPRE) has been shown to give a very good estimate of this parameter for Tikhonov Regularization. In this paper we propose an approach to extend UPRE method to the TV problem. However, applying the extended UPRE is impractical in the case of inverse problems such as de blurring, due to the large scale of the associated linear problem. We also propose an approach to reducing the large scale problem to a small problem, significantly reducing computational requirements while providing a good approximation to the original problem.

99 GENERAL AND MISCELLANEOUS↗