Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Production of medical {sup 99m}Tc isotope via photonuclear reaction

{sup 99m}Tc with a 6 hour half-life is one of the most important medical isotopes used for the Single-Photon Emission Computed Tomography (SPECT) inspection in hospitals of US, Canada, Europe and Japan. {sup 99m}Tc isotopes are extracted by the milking method from parent {sup 99}Mo isotopes with a 66 hour half-life. The supply of {sup 99}Mo isotopes now encounters a serious crisis. Hospitals may not suitably receive {sup 99}Mo medical isotopes in near future, due to difficulties in production by research nuclear reactors. Many countries are now looking for alternative ways to generate {sup 99}Mo isotopes other than those with research reactors. We discuss a sustained availability of {sup 99m}Tc isotopes via the {sup nat}Mo(γ, n) photonuclear reaction, and discuss to solve technical problems for extracting pure {sup 99m}Tc isotopes from other output materials of photonuclear reactions.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling framework for isotopic labeling of heteronuclear moieties

Background: Isotopic labeling is an analytic technique that is used to track the movement of isotopes through reaction networks. In general, the applicability of isotopic labeling techniques is limited to the investigation of reaction networks that consider homonuclear moieties, whose atoms are of one tracer element with two isotopes, distinguished by the presence of one additional neutron. Results: This article presents a reformulation of the modeling framework for isotopic labeling, generalized to arbitrarily large, heteronuclear moieties, arbitrary numbers of isotopic tracer elements, and arbitrary numbers of isotopes per element, distinguished by arbitrary numbers of additional neutrons. Conclusions: With this work, it is now possible to simulate the isotopic labeling states of metabolites in completely arbitrary biochemical reaction networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

California GAMA Special Study: An isotopic and dissolved gas investigation of nitrate source and transport to a public supply well in California's Central Valley

This study investigates nitrate contamination of a deep municipal drinking water production well in Ripon, CA to demonstrate the utility of natural groundwater tracers in constraining the sources and transport of nitrate to deep aquifers in the Central Valley. The goal of the study was to investigate the origin (source) of elevated nitrate and the potential for the deep aquifer to attenuate anthropogenic nitrate. The site is ideal for such an investigation. The production well is screened from 165-325 feet below ground surface and a number of nearby shallow and deep monitoring wells were available for sampling. Furthermore, potential sources of nitrate contamination to the well had been identified, including a fertilizer supply plant located approximately 1000 feet to the east and local almond groves. A variety of natural isotopic and dissolved gas tracers including {sup 3}H-{sup 3}He groundwater age and the isotopic composition of nitrate are applied to identify nitrate sources and to characterize nitrate transport. An advanced method for sampling production wells is employed to help identify contaminant contributions from specific screen intervals. Nitrate transport: Groundwater nitrate at this field site is not being actively denitrified. Groundwater parameters indicate oxic conditions, the dissolved gas data shows no evidence for excess nitrogen as the result of denitrification, and nitrate-N and -O isotope compositions do not display patterns typical of denitrification. Contaminant nitrate source: The ambient nitrate concentration in shallow groundwater at the Ripon site ({approx}12 mg/L as nitrate) is typical of shallow groundwaters affected by recharge from agricultural and urban areas. Nitrate concentrations in Ripon City Well 12 (50-58 mg/L as nitrate) are significantly higher than these ambient concentrations, indicating an additional source of anthropogenic nitrate is affecting groundwater in the capture zone of this municipal drinking water well. This study provides two new pieces of evidence that the Ripon Farm Services Plant is the source of elevated nitrate in Ripon City Well 12. (1) Chemical mass balance calculations using nitrate concentration, nitrate isotopic composition, and initial tritium activity all indicate that that the source water for elevated nitrate to Ripon City Well 12 is a very small component of the water produced by City Well 12 and thus must have extremely high nitrate concentration. The high source water nitrate concentration ({approx}1500 mg/L as nitrate) required by these mass balance calculations precludes common sources of nitrate such as irrigated agriculture, dairy wastewater, and septic discharge. Shallow groundwater under the Ripon Farm Services RFS plant does contain extremely high concentrations of nitrate (>1700 mg/L as nitrate). (2) Nitrogen and oxygen isotope compositions of nitrate indicate that the additional anthropogenic nitrate source to Ripon City Well 12 is significantly enriched in {delta}{sup 18}O-NO{sub 3}, an isotopic signature consistent with synthetic nitrate fertilizer, and not with human or animal wastewater discharge (i.e. dairy operations, septic system discharge, or municipal wastewater discharge), or with organic fertilizer. Monitoring wells on and near the RFS plant also have high {delta}{sup 18}O-NO{sub 3}, and the plant has handled and stored synthetic nitrate fertilizer that will have this isotopic signature. The results described here highlight the complexity of attributing nitrate found in long screened, high capacity wells to specific sources. In this case, the presence of a very high concentration source near the well site combined with sampling using multiple isotopic tracer techniques and specialized depth-specific techniques allowed fingerprinting of the source in the mixed-age samples drawn from the production well.

54 ENVIRONMENTAL SCIENCES↗

California GAMA Special Study: Stable isotopic composition of groundwater boron – Analytical method development

Boron is a ubiquitous dissolved constituent in natural waters due to its high solubility, natural occurrence in continental crust, and anthropogenic use in fertilizers, consumer products, and other non-natural sources. The two stable isotopes of boron, 10 B and 11 B (natural abundances ≈ 19.9 and ≈ 80.1 atom percent, respectively), undergo isotopic fractionation due to a variety of chemical processes related to boron speciation ( 10 B is preferentially incorporated into B(OH) 4 - versus B(OH) 3 , e.g. Byrne et al., 2006). The isotopic composition of dissolved boron in groundwater can be used to determine the source(s) of boron; this information can be used to infer the source(s) of other co-migrating contaminants (e.g. nitrate, pharmaceuticals, etc.). Boron behaves as a conservative element in groundwater and surface water systems (Barth, 2000), and the isotopic signature of boron is most useful in conjunction with other stable and radiogenic isotope systems (e.g. δ 18 O, δ 15 N, δ 13 C, 87 Sr/ 86 Sr; Tirez et al., 2010; Widory et al., 2004; Widory et al., 2005) to determine the source(s) of contaminants of interest. We present here a method for boron purification in natural water samples (groundwater, surface water, and seawater) by ion exchange chemistry and measurement of boron isotopic composition by MC-ICP-MS. These methods can be applied to samples with boron concentrations as low as 10 ppb with precision on δ 11 B measurements better than ± 1 ‰. We utilize boron isotopic measurements of boric acid, groundwater, and seawater standards to validate the methods. We also present boron isotopic measurements of San Diego County domestic well samples to demonstrate how these methods can be applied to any study of natural water samples.

07 ISOTOPE AND RADIATION SOURCES↗

Li Isotope Signatures using Optical Spectroscopies

The primary goal of this work is to investigate the detection capabilities of laser ablation molecular isotopic spectrometry (LAMIS) and Raman spectroscopy for lithium isotopic determination as related to Li enrichment activities. LAMIS is an emerging spectroscopic technique that takes advantage of the fact that molecules exhibit much larger isotopic wavelength shifts in molecular emission spectra than their atomic counterparts. Raman spectroscopy has been shown to exhibit isotopic shifts if a given molecular vibration involves the isotope of interest. Both techniques are comprised of the same basic hardware: a spectrometer, a laser system (pulsed for LAMIS, pulsed or CW for Raman), and an intensified charge-coupled device (ICCD). Shifts in Raman spectra due to lithium isotopes in Li 2 C0 3 and LiOH*H 2 0 were observed. LAMIS measurements of the same compounds have not been successful yet, as no lithium containing molecular emissions have been identified to this point. However, an isotopic shift of the self-reversal of an atomic lithium emission was observed, which is another optical technique used to measure isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

ENRICHED STABLE ISOTOPE TARGET PREPARATION AT THE OAK RIDGE NATIONAL LABORATORY

Since the 1960s the Department of Energy (DOE) Isotope Program, through the Isotope Development Group at the Oak Ridge National Laboratory, has been developing and supplying, among other things, enriched stable isotope targets for nuclear research around the world. This group also maintains and distributes the DOE inventory of enriched stable isotopes. Chemical and pyrochemical techniques are used to prepare enriched stable isotopes from this inventory in the desired chemical form. Metallurgical, ceramic, or vacuum processing methods are then used to prepare the isotopes in a wide range of physical forms from thin films, foils, and coatings to large fabricated shapes to meet the needs of experimenters. Significant characterization capabilities are also available to assist in the preparation and evaluation of these custom materials. This work is part of the DOE Isotope Program, which recently transferred to the Office of Nuclear Physics, DOE Office of Science, resulting in a stronger emphasis on enabling R&D. This presentation will focus on the custom preparation of enriched stable isotope targets and other research materials.

accelerator targets↗

Femtosecond filament-laser ablation molecular isotopic spectrometry

A new remote sensing technology for real-time isotopic analysis is introduced: Femtosecond Filament-Induced Laser Ablation Molecular Isotopic Spectrometry (F 2 -LAMIS). The technique combines femtosecond (fs) laser filamentation and ablation-based molecular isotopic spectroscopy, thereby enabling isotopic analysis of samples at a distance, in ambient air and at ambient pressure conditions. Isotopic analysis of zirconium (Zr) samples by F 2 -LAMIS is demonstrated, and the molecular and atomic emission intensity, and properties of the filament-induced plasma generated at different filament propagation distances were investigated. Spectral fitting of F 2 -LAMIS spectra enabled semi-quantitative isotopic analysis without the use of calibration standards, which was independent of the filament propagation distance for the studied range. As a result, this technology provides new capabilities for direct isotopic ratio measurements at remote distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upper limits for the existence of long-lived isotopes of roentgenium in natural gold

A sensitive search for isotopes of a superheavy element (SHE) in natural gold materials has been performed with accelerator mass spectrometry at the Vienna Environmental Research Accelerator, which is based on a 3-MV tandem accelerator. Because the most likely SHE in gold is roentgenium (Rg, Z = 111), the search concentrated on Rg isotopes. Two different mass regions were explored: (i) For the neutron-deficient isotopes {sup 261}Rg and {sup 265}Rg, abundance limits in gold of 3x10{sup -16} were reached (no events observed). This is in stark contrast to the findings of Marinov et al.[Int. J. Mod. Phys. E 18, 621 (2009)], who reported positive identification of these isotopes with inductively coupled plasma sector field mass spectrometry in the (1-10)x10{sup -10} abundance range. (ii) Theoretical models of SHEs predict a region of increased stability around the proton and neutron shell closures of Z = 114 and N = 184. We therefore investigated eight heavy Rg isotopes, {sup A}Rg, A = 289, 290, 291, 292, 293, 294, 295, and 296. For six isotopes no events were observed, setting limits also in the 10{sup -16} abundance range. For {sup 291}Rg and {sup 294}Rg we observed two and nine events, respectively, which results in an abundance in the 10{sup -15} range. However, pileup of a particularly strong background in these cases makes a positive identification as Rg isotopes--even after pileup correction--unlikely.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oxygen isotopic investigation of silicic magmatism in the Stillwater caldera complex, Nevada: Generation of large-volume, low-δ 18 O rhyolitic tuffs and assessment of their regional context in the Great Basin of the western United States

Successive caldera-forming eruptions from ca. 30 to 25 Ma generated a large nested caldera complex in western Nevada that was subsequently dissected by Basin and Range extension, providing extraordinary cross-sectional views through diverse volcanic and plutonic rocks. A high-resolution oxygen isotopic study was conducted on units that represent all major parts of the Job Canyon, Louderback Mountains, Poco Canyon, and Elevenmile Canyon caldera cycles (29.2–25.1 Ma), and several Cretaceous plutons that flank the Stillwater caldera complex. We provide new oxygen and strontium isotope data for 12 additional caldera centers in the Great Basin, which are synthesized with >150 published oxygen and strontium isotope analyses for regional Mesozoic basement rocks. Stillwater zircons span a large isotopic range (δ 18 O zircon of 3.6‰–8.2‰), and all caldera cycles possess low-δ 18 O zircons. In some cases, they are a small proportion of the total populations, and in others, they dominate, such as in the low-δ 18 O rhyolitic tuffs of Job Canyon and Poco Canyon (δ 18 O zircon = 4.0‰–4.3‰; δ 18 O magma = 5.5‰–6‰). These are the first low-δ 18 O rhyolites documented in middle Cenozoic calderas of the Great Basin, adding to the global occurrence of these important magma types that fingerprint recycling of shallow crust altered by low-δ 18 O meteoric waters. The appearance of low-δ 18 O rhyolites in the Stillwater caldera complex is overprinted on a Great Basin–wide trend of miogeoclinal sediment contribution to silicic magmas that elevates δ 18 O compositions, making identification of 18 O depletions difficult. Though not a nominally low-δ 18 O rhyolite, the tuff of Elevenmile Canyon possesses both low-δ 18 O and high-δ 18 O zircon cores that are overgrown by homogenized zircon rims that approximate the bulk zircon average, pointing to batch assembly of isotopically diverse upper crustal melts to generate one of the most voluminous (2500–5000 km 3 ) tuff eruptions in the Great Basin. Despite overlapping in space and time, each caldera-forming cycle of the Stillwater complex has a unique oxygen isotope record as retained in single zircons. Most plutons that were spatially and temporally coincident with calderas have isotopic compositions that diverge from the caldera-forming tuffs and cannot be their cogenetic remnants.

58 GEOSCIENCES↗

NEUTRON-RICH CHROMIUM ISOTOPE ANOMALIES IN SUPERNOVA NANOPARTICLES

Neutron-rich isotopes with masses near that of iron are produced in Type Ia and II supernovae (SNeIa and SNeII). Traces of such nucleosynthesis are found in primitive meteorites in the form of variations in the isotopic abundance of {sup 54}Cr, the most neutron-rich stable isotope of chromium. The hosts of these isotopic anomalies must be presolar grains that condensed in the outflows of SNe, offering the opportunity to study the nucleosynthesis of iron-peak nuclei in ways that complement spectroscopic observations and can inform models of stellar evolution. However, despite almost two decades of extensive search, the carrier of {sup 54}Cr anomalies is still unknown, presumably because it is fine grained and is chemically labile. Here, we identify in the primitive meteorite Orgueil the carrier of {sup 54}Cr anomalies as nanoparticles (<100 nm), most likely spinels that show large enrichments in {sup 54}Cr relative to solar composition ({sup 54}Cr/{sup 52}Cr ratio >3.6 x solar). Such large enrichments in {sup 54}Cr can only be produced in SNe. The mineralogy of the grains supports condensation in the O/Ne-O/C zones of an SNII, although a Type Ia origin cannot be excluded. We suggest that planetary materials incorporated different amounts of these nanoparticles, possibly due to late injection by a nearby SN that also delivered {sup 26}Al and {sup 60}Fe to the solar system. This idea explains why the relative abundance of {sup 54}Cr and other neutron-rich isotopes vary between planets and meteorites. We anticipate that future isotopic studies of the grains identified here will shed new light on the birth of the solar system and the conditions in SNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Sulfur isotope analysis of microcrystalline iron sulfides using secondary ion mass spectrometry imaging: Extracting local paleo-environmental information from modern and ancient sediments

Rationale: Sulfur isotope ratio measurements of bulk sulfide from marine sediments have often been used to reconstruct environmental conditions associated with their formation. In situ microscale spot analyses by secondary ion mass spectrometry (SIMS) and laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) have been utilized for the same purpose. However, these techniques are often not suitable for studying small (≤10 μm) grains or for detecting intra-grain variability. Methods: In this work, we present a method for the physical extraction (using lithium polytungstate heavy liquid) and subsequent sulfur isotope analysis (using SIMS; CAMECA IMS 7f-GEO) of microcrystalline iron sulfides. SIMS sulfur isotope ratio measurements were made via Cs + bombardment of raster squares with sides of 20–130 μm, using an electron multiplier (EM) detector to collect counts of 32 S - and 34 S - for each pixel (128 × 128 pixel grids) for between 20 and 960 cycles. Results: The extraction procedure did not discernibly alter pyrite grain-size distributions. The apparent inter-grain variability in 34 S/ 32 S in 1–4 μm-sized pyrite and marcasite fragments from isotopically homogeneous hydrothermal crystals was ~ ±2‰ (1σ), comparable with the standard error of the mean for individual measurements (≤ ±2‰, 1σ). In contrast, grain-specific 34 S/ 32 S ratios in modern and ancient sedimentary pyrites and marcasites can have inter- and intra-grain variability >60‰. The distributions of intra-sample isotopic variability are consistent with bulk 34 S/ 32 S values. Conclusions: SIMS analyses of isolated iron sulfide grains yielded distributions that are isotopically representative of bulk 34 S/ 32 S values. Populations of iron sulfide grains from sedimentary samples record the evolution of the S-isotopic composition of pore water sulfide in their S-isotopic compositions. These data allow past local environmental conditions to be inferred.

59 BASIC BIOLOGICAL SCIENCES↗

Applying the principles of isotope analysis in plant and animal ecology to forensic science in the Americas

Forensic science is an applied science that helps investigators answer questions at the heart of a crime: Who, What, When, Where, and How. As part of that process, forensic practitioners use basic laws of chemistry and physics to examine evidence and theories of origin to interpret said evidence. Ecological research has had an extraordinary impact on forensic science through the development and application of a specialized measurement technique useful for examining evidence that appears chemically and physically identical: stable isotope analysis. In this review, we examine the proven utility of stable isotope analysis in forensic settings from an ecological perspective, concentrating on work from the Americas completed within the last three decades. Our primary focus is on the interpretation of stable isotope ratios using plant and animal physiological models for “source inference,” although we also recognize that sample-to-sample comparison of stable isotope ratios can be useful in many forensic settings. Examples of the forensic application of stable isotope analysis cover the gamut, from cotton used in counterfeit bills to anthrax shipped through the U.S. Postal Service, from beer adulterated with cheap adjuncts to human remains discovered in shallow graves and never identified. Recent methodological developments—including isotope analysis of specific compounds, multiple elements, and radioisotopes—and the generation of isotope landscapes, or isoscapes, approaches for data interpretation promises that stable isotope analysis will continue to be used in forensic settings for another three decades… and beyond.

Chesson, Lesley A.↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Uranium Isotopic Fractionation Induced by U(VI) Adsorption onto Common Aquifer Minerals

Uranium groundwater contamination due to U mining and processing affects numerous sites globally. Bioreduction of soluble, mobile U(VI) to U(IV)-bearing solids is potentially a very effective remediation strategy. Uranium isotopes ( 238 U/ 235 U) have been utilized to track the progress of microbial reduction, with laboratory and field studies finding a ~1‰ isotopic fractionation, with the U(IV) product enriched in 238 U. However, the isotopic fractionation produced by adsorption may complicate the use of 238 U/ 235 U to trace microbial reduction. A previous study found that adsorption of U(VI) onto Mn oxides produced a -0.2‰ fractionation with the adsorbed U(VI) depleted in 238 U. In this paper, adsorption to quartz, goethite, birnessite, illite, and aquifer sediments induced an average isotopic fractionation of -0.15‰ with the adsorbed U(VI) isotopically lighter than coexisting aqueous U(VI). In bicarbonate-bearing matrices, the fractionation depended little on the nature of the sorbent, with only birnessite producing an atypically large fractionation. In the case of solutions with ionic strengths much lower than those of typical groundwater, less isotopic fractionation was produced than U(VI) solutions with greater ionic strength. Finally, studies using U isotope data to assess U(VI) reduction must consider adsorption as a lesser, but significant isotope fractionation process.

54 ENVIRONMENTAL SCIENCES↗

The Application and Potential Artifacts of Zeeman Cold Vapor Atomic Absorption Spectrometry in Mercury Stable Isotope Analysis

Zeeman cold vapor atomic absorption spectrometry (CVAAS) has been widely used for environmental mercury (Hg) detection and quantification for decades, but little is known about its utility and potential artifacts in analyzing Hg with varying isotope compositions. We show that each Hg isotope responds differently by CVAAS analysis, with 200 Hg and 202 Hg isotopes exhibiting signal intensities ~10 times greater than those of 198 Hg and 201 Hg isotopes. However, all Hg isotopes show a linear correlation between Hg concentration and signal intensity, validated by both measurements and theoretical simulations. Zeeman CVAAS could thus offer a convenient, inexpensive tool for determining Hg isotopes, particularly in using one or two enriched Hg isotopes for tracing Hg biogeochemical transformations, such as partitioning, ion exchange, sorption–desorption, and methylation–demethylation in environmental matrices. Additionally, we caution that care must be taken when CVAAS is used for quantifying Hg in samples with changing isotope compositions to avoid measurement errors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoselective isotope fractionation dynamics of N 2 with cosmo and atmospheric chemistry perspectives

Stable isotope ratio measurements provide valuable insights into a broad range of natural processes, from planetary atmospheres and climate to interstellar chemistry. Nitrogen, which has two stable isotopes, exhibits varying isotope ratios across the solar system. To model these observations, the isotope fraction as a function of energy is essential. At the Advanced Light Source (ALS), we measured the photodissociation of molecular nitrogen (N 2 ) with vacuum UV photons where a single photon is sufficiently energetic to dissociate the strong bond. The nitrogen atoms produced are scavenged with H 2 to form ammonia, whose isotopic makeup is determined. Blending the experiments with dynamical computations that include the shielding of light, we examine the isotopic composition and electronic atomic states produced. The measured photodissociation of N 2 at a natural isotopic composition with a frequency broad light beam exceptionally strongly favors the formation of the heavier nitrogen isotope, 15 N. Computations concur and suggest that the maximum in the quantum yield reflects significant variations in the specific electronic quantum states of the product N atoms that have quite different reactivities. Our quantum computations show that at similar energies, photodissociation of 14 N 14 N and 15 N 14 N can lead to different product channels. The computed dynamics include extensive state-selective spin–orbit and nonadiabatic couplings affecting the light absorption and dissociation pathways that proceed via the triplet manifold of states. Our results are relevant for future exploration missions, both in situ and sample-return and for other molecules such as O 2 and CO.

Komarova, Ksenia [Hebrew Univ. of Jerusalem (Israe↗

Uncovering Magic Isotopes with the Power of HPC

Where do elements come from? How does the strong force bind subatomic particles into nuclei? What can scientists understand from nuclei with unusual proton–neutron ratios? Nuclear physicists at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) are seeking answers to such questions with the help of powerful supercomputers. The element tin is of particular interest to ORNL. In 2010, ORNL researchers discovered that the nucleus of a tin isotope, tin-132, was doubly “magic.” Isotopes are deemed magic when they have nucleons (positively charged proton particles or neutrally charged neutron particles) that complete a shell within the nucleus, making the magic isotopes much more strongly bound than those that are not magic. Isotopes with 2, 8, 20, 28, 50, 82, or 126 neutrons or protons are considered magic. A doubly magic isotope has two of these special numbers—one that describes its number of protons and one that describes its number of neutrons. Tin-132, for example, has 50 protons and 82 neutrons. The discovery of new magic isotopes can significantly affect the chart of nuclides, a table that orders the radioactive behaviors of isotopes. Because magic isotopes are more strongly bound, their structure impacts entire regions of the chart of nuclides and the limit of how many nuclei can exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗