Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ILs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

CROCUS Forward Scatter Disdrometer Data at Argonne National Laboratory Prairie Site

The Vaisala FD70 is a multi-parameter present weather and visibility sensor designed to measure precipitation type, intensity, and visibility with high accuracy in diverse environmental conditions. It uses a combination of forward-scatter measurement and optical disdrometer technologies to detect drop size, fall speeds, and optical properties, enabling the classification of various precipitation types such as rain, snow, sleet, and freezing rain along is visibility estimates. The FD70 provides quantitative estimates of liquid-equivalent precipitation rate and meteorological optical range (MOR), supporting applications in meteorological research, aviation, and road weather monitoring. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20 acre prairie site at Argonne National Lab, located in Lemont, IL. Data is available in netcdf format. Each file contains one second interval data, for approximately 24 hrs each day. File naming convention includes the project (CROCUS), location (ATMOS), instrument name, data level (raw, a1), and date (year, month, day).

54 ENVIRONMENTAL SCIENCES↗

Processed sap flow and fine-root trait data associated with summer drought responses in temperate trees in Lisle, Illinois, USA (2019–2021)

These data support the manuscript “Acquisitive root exploration strategies help maintain higher peak sap flux rates during summer drought, but more root biomass does not”. The dataset includes processed sap flow measurements and fine-root trait data collected between 2019 and 2021 from temperate monodominant tree plots established in the 1920s to 1930s ranging in size from 0.05 to 0.8 ha at The Morton Arboretum in Lisle, IL. Sap flow was measured with ICT sap flow sensors using the heat ratio method. Fine-root traits were measured from soil cores which includes specific root length (SRL), specific root area (SRA), diameter, biomass, and length for diameter classes ≤1 mm and ≤2 mm. The package contains comma separated value (CSV) data files and associated metadata that can be viewed and analyzed using common software such as spreadsheet programs, R, and Python. These data are used to investigate how variation in fine-root traits relate to tree water use and drought response during summer drought linking belowground root traits and aboveground physiological responses.

drought↗

CROCUS Tipping Bucket Rain Gauge Data from Argonne Deployable Mast Deployed at NEIU Carruthers Center for Inner City Studies (CCICS)

The Tipping Bucket Rain Gauge (TBRG) dataset contains data from a non-heated Met One 12-inch tipping bucket rain gauge that was mounted on the Argonne Deployable Mast (ADM). The ADM is a rapid deployable meteorological trailer that can be outfitted with instrumentation to measure urban heat island effects, urban flooding or urban flux measurements. During the urban flooding field campaign, the ADM was outfitted with multiple precipitation measurement systems, including the TBRG. This dataset contains one minute measurements for precipitation accumulation during the ADM's deployment at the Northeastern Illinois University (NEIU) Carruthers Center for Inner City Studies (CCICS) campus. These data are helpful for identifying periods of precipitation, leading to potential flooding. TBRGs can be used to validate optical rain gauge data and disdrometer data collected during the CROCUS urban flooding campaign. Data were collected at the CCICS building parking lot, located in the south side of Chicago, IL. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (ADM-ccics), instrument name (tbrg), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or act-doe.

1-minute Precipitation Accumulation↗

High-Fidelity Building Emulator

This dataset provides high-fidelity time series data for an emulated commercial office building sited in the Chicago, IL area during a Typical Meteorological Year (TMY). This dataset consists of air-side HVAC measurements and control inputs, and it includes normal operations as well as various implemented faults (with associated ground truth measurements) implemented on selected days. This data could be used to quantify and compare the impacts of different faults, and it could also be used as training or validation data for machine learning algorithms (e.g., reduced-order modelling, fault detection and diagnosis).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling, Design, and Testing of a Novel Biphasic Solvent-Enabled Absorption System for Post-Combustion Carbon Capture

A novel absorption process enabled by a new class of biphasic solvents for post-combustion carbon capture (BiCAP) is presently being developed at the University of Illinois at Urbana-Champaign. The new biphasic solvents are water-lean solvent blends that develop dual liquid phases with the absorbed CO2 highly enriched in one of the phases. These solvents are superior in CO2 capacity and have high thermal and oxidative stability compared to MEA. The BiCAP technology features a unique process configuration of multi-stage CO2 absorption and liquid–liquid phase separation during CO2 absorption, allowing continual separation and removal of the CO2-enriched liquid phase for maintaining low solvent viscosity and a fast absorption rate. A 40 kWe-scale skid has recently been constructed at the Abbott Power Plant in Champaign, IL, to test the BiCAP solvent in continuous operation with a slipstream of real post-combustion flue gas. Along with improvements in the stripping configuration including cold feed bypass, the process is expected to achieve a minimum reboiler duty of 2,210 kJ/kg CO2 captured at a stripper operating pressure of 6 bar.

20 FOSSIL-FUELED POWER PLANTS↗

Higher spin partition functions via the quasinormal mode method in de Sitter quantum gravity

In this note we compute the 1-loop partition function of spin- s s fields on Euclidean de Sitter space S^{2n+1} S 2 n + 1 using the quasinormal mode method. Instead of computing the quasinormal mode frequencies from scratch, we use the analytic continuation prescription L_{\text{AdS}}\to iL_{\text{dS}} L AdS → i L dS , appearing in the dS/CFT correspondence, and Wick rotate the normal mode frequencies of fields on thermal \text{AdS}_{2n+1} AdS 2 n + 1 into the quasinormal mode frequencies of fields on de Sitter space. We compare the quasinormal mode and heat kernel methods of calculating 1-loop determinants, finding exact agreement, and furthermore explicitly relate these methods via a sum over the conformal dimension. We discuss how the Wick rotation of normal modes on thermal \text{AdS}_{2n+1} AdS 2 n + 1 can be generalized to calculating 1-loop partition functions on the thermal spherical quotients S^{2n+1}/\mathbb{Z}_{p} S 2 n + 1 / ℤ p . We further show that the quasinormal mode frequencies encode the group theoretic structure of the spherical spacetimes in question, analogous to the analysis made for thermal AdS in [1-3] .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surveillance of Site A and Plot M Report (2019)

The environmental surveillance program discussed in this report is an ongoing activity that resulted from the 1976-1978 radiological characterization of the former site of Argonne National Laboratory and its predecessor, the University of Chicago's Metallurgical Laboratory. This site was part of the World War II Manhattan Engineer District Project and was located in a forested area southwest of Chicago, IL, owned by the Forest Preserve District of Cook County, now known as the Palos Area Preserves. Research was conducted at two locations in the Palos Area Preserves: Site A, a 19-acre area that contained experimental laboratories and nuclear reactor facilities; and Plot M, a 150 ft x 140 ft area used for the burial of radioactive waste. The location of the Palos Area Preserves is shown in Figure 2.1. The locations of Site A and Plot M are shown in Figure 2.2. Previous comprehensive reports on this subject provide additional detail and illustrations on sampling locations and provide descriptive material along with the results through 1981. Annual reports are available for 1982 through 2018. While earlier data will not be repeated in this report, reference is made to some of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges of Investigating Redox Reactions in Room Temperature Ionic Liquids [Slides]

The goal of this project is to understand the effects of the morphology and chemical properties of ionic liquids (IL) on the heterogeneous electron transfer processes of simple inorganic ions. This project will seek to understand the fundamental chemical and physical phenomena in ionic liquids through electrochemical, and material characterization techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Negative Muon Count for the FNAL Muon g-2 Experiment

The primary goal of the FNAL Muon g-2 Experiment, located in Batavia, IL, USA, is to measure the anomalous magnetic dipole moment, a μ = (g-2)/2, of a muon to a precision of 0.14 ppm. Initial results from the experiment confirm a discrepancy between the experimental value of the muon anomaly compared with the theoretical value first discovered by the Brookhaven Muon g-2 Experiment in 2001. This discrepancy hints at new physics. However, running the experiment with negative muons is essential in order to verify the experimental value of the muon anomaly. As neither experiments nor simulation studies pertaining to the muon anomaly have been performed with negative muons, the goal of this work is to estimate the rates of negative muons arriving at the FNAL Muon g-2 experiment so that scientists can estimate the time required to run the experiment with negative muons. In order to do this, we performed several simulations of the Muon Campus, which delivers muons to the FNAL Muon g-2 Experiment, using the G4Beamline v. 3.06 at the National Energy Research Computing Center. We performed separate simulations for different sections of the muon campus, and simulations were repeated twice, once for negative muons and once for positive muons. An initial 10 9 protons were shot on target for both the negative and positive muon simulations. We found that the rate of negative muons arriving at the experiment was 0.549 times the rate of positive muons arriving at the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intelligent Monitoring System for Real-time Geologic Storage, Optimization, and Reservoir Management

The objective of the subtask was to develop a near-real-time monitoring system for seismic data at the Decatur, IL, geologic carbon sequestration (GCS) site and specifically include fiber-optic cable derived distributed acoustic signal (DAS) data in the process. Owing to the large volumes of data, we opted to utilize existing deep borehole conventional seismic sensors for detection and pull DAS and shallow borehole seismic data once a detection has been made. Unfortunately, the horizontal fiber-optic cables did not yield microseismic signals for use in locating events near the GCS site. Various stacking and filtering approaches were tested without any coherent detection becoming apparent. We attribute the insensitivity to local microseismic events to a lack of coupling in downhole, vertical cable and the non-ideal alignment of the horizontal fiber-optic cable to the vertically polarized seismic energy. Despite the inability to detect and utilize the DAS data from the fiber-optic cables, we developed a general processing framework that enables easy adaptation for future deployment of fiber-optic cables with better suited alignment at Decatur or elsewhere.

Kaven, J. Ole↗

Decontamination and Sterilization of Surfaces using Low Cost Ionic Liquids (CRADA Final Report)

The current study made a comprehensive literature review of the structure activity relationship (SAR) for microcidal and virucidal influence of ionic liquids. It summarized the key structure parameters that have close correlation to the antimicrobial and antiviral properties of the ILs. It proposed an experimental plan on developing and testing an effective ionic liquid from renewable lignocellulosic biomass. The goal is to understand the structure activity relationship (SAR) for virucidal influence of ionic liquids through comprehensive literature search and data analysis. A full experimental plan will be drafted based on the literature summary. Perform a comprehensive literature search to aid the development of an effective and easily deployable method to inactivate SARS-CoV-2 and decontaminate surfaces based on low-cost functional ionic liquids. These designer solvents have the potential to be a compelling and environmentally friendly alternative to common chemical disinfectants. Literature summary report including reported ionic liquid structures, synthesis and testing methods, and the structure activity relationship. Experimental plan on developing a low cost effective antiviral ionic liquid.

59 BASIC BIOLOGICAL SCIENCES↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Full-scale FEED Study for Retrofitting the Prairie State Generating Station with an 816 MWe Capture Plant using Mitsubishi Heavy Industries Post-Combustion CO 2 Capture Technology

A full front-end engineering design (FEED) study to for a carbon capture system for Unit #2 (816 MWe) at the Prairie State Generating Company’s (PSGC) Energy Campus in Marissa, IL based on the KM CDR Process CO 2 capture technology from Mitsubishi Heavy Industries (MHI) using their proprietary solvent KS-21TM. If built this carbon capture plant would be the world's largest to date. The cost of capture of 100 percent of the plant emissions was calculated to be $43.42 per metric tonne of CO 2 based on levelized costs for 30 years of operation (85% capacity factor), and includes Interest on Debt and Return on Equity During Operation.

01 COAL, LIGNITE, AND PEAT↗

Nanoparticle Mediated Delivery of Therapeutic mRNA for Protection Against Lung Damage

Medical countermeasures (MCMs) based on messenger ribonucleic acid (mRNA) are promising due to their programmability, targeting precision and specificity, predictable physicochemical properties, and amenability to scalable manufacture. However, safe and effective delivery vehicles are needed, especially for targeting the lung. We developed a generalized approach to nanoparticle-mediated mRNA delivery to lung, and used it to evaluate candidate therapies. In initial studies, reporter mRNA was delivered using lipid-coated mesoporous silica nanoparticles (LC-MSNs) and lipid nanoparticles (LNPs), the latter with greater consistency. Then, mRNA encoding known protein therapies were delivered using LNPs. These formulations showed some toxicity in mice with lung damage, but those with IL-1RA, sACE2-Ig, and ANGPT1 mRNA were modestly therapeutic on balance. Our work advances the state of the art for mRNA delivery to lung, and provides a foundation for evaluating and characterizing mRNA-based lung therapies, including three that appear to be exceptionally promising.

59 BASIC BIOLOGICAL SCIENCES↗