Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

The Formation Mechanism of Helium-Rich Subdwarf B Stars

This program used the Far Ultraviolet Spectroscopic Explorer (FUSE) to measure the surface abundances of three helium-rich hot subdwarfs in the Galactic field, to test our hypothesis that such stars form via a late helium flash while descending the white dwarf cooling curve. If these stars form via a late He flash, the stellar envelope should be mixed with the interior, enhancing the surface carbon abundance enormously while depleting the surface hydrogen. The first observation of PG1544+488 was incomplete because detector 2 was turned off, but the repeat observations were fully successful. The observations of LB1766 had no problems and were fully successful. The observations of PG1127+019 became infeasible when FUSE lost some of its pointing control, so it was replaced with JL87, which was also observed successfully.

Luers, Jeannine N.↗

Cryostat system for temperatures on the order of 2 deg K or less

A cryostat system for cooling a device to a temperature on the order of 2 K or less includes a dewar, in which helium, in other than the superfluid state, is stored. Helium flows from the dewar through a heat exchanger tube and a restrictor tube, which controls the helium flow rate, into the cavity of a heat exchanger, to whose outer wall the device to be cooled is attached. A pressure regulator value controls the pressure in the cavity to be very low. As the helium exits the restrictor tube into the cavity, due to low pressure cavity, it becomes an aerosol mixture of helium gas and superfluid helium droplets at the desired temperature. The latter form a thin layer or film of superfluid helium on the inner side of the heat exchanger wall and thereby cool the device, which is attached to the wall to the desired temperature.

Miller, C. G.↗

Basic data on hydrogen-deficient stars

The current state of knowledge on the diistribution and motions of various types of hydrogen-deficient stars, and of their positions in the H-R diagram, is reviewed. It is concluded that the extreme helium stars (with the exception of the H-deficient binaries) and cool hydrogen-deficient stars belong to the population of the Galactic nuclear bulge, whereas the intermediate helium stars are young stars of Population I. The helium-rich sdO stars appear to be a local sample which is predominantly Population I.

Drilling, J. S.↗

Helium Incorporation into Scandium Fluoride, a Model Negative Thermal Expansion Material

Scandium trifluoride is a model negative thermal expansion (NTE) material. Its simple structure can be described as an A-site vacant perovskite, and it shows isotropic NTE over a very wide temperature range (up to ~1100 K), due to transverse vibrational motion of the fluoride. Like many framework NTE materials, it undergoes a phase transition at low pressures, adopting a rhombohedral (R3̅c) structure at >0.7 GPa and 300 K in commonly used nonpenetrating pressure media, such as silicone oil. High pressure X-ray diffraction data and gas uptake/release measurements indicate that, on compression in helium above ~200 K, helium is inserted into ScF 3 to form the defect perovskite He x ScF 3 . The incorporation of helium stiffens the structure and changes its phase behavior. At room temperature, complete filling of the structure with helium does not occur until >1.5 GPa. On compression, a cubic perovskite structure is maintained until ~5 GPa. As the pressure was increased to ~9.5 GPa, a further transition occurred at ~7 GPa. The first transition at ~5 GPa is likely to a tetragonal (P4/mbm) perovskite, but the detailed structure of the perovskite phase formed on compression above ~7 GPa is unclear. Cooling down from 300 to 100 K in helium at ~0.4 GPa leads to an approximate composition of He 0.1 ScF 3 . High pressure neutron diffraction measurements, in the temperature range 15–150 K show that the incorporation of helium increases the pressure at which the cubic (Pm3̅m) to rhombohedral (R3̅c) putative quantum structural phase transition occurs from close to 0 GPa to ~0.2 GPa at 0 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Channel Flow with Square Ribs for Blanket First-Wall Cooling: Geometry-Specific Tuning of k-ω Model Using Adjoint Method

Cooling of the plasma-facing first wall is challenging in the design of blanket components because of the high heat flux (on the order of 𝑀𝑊/𝑚2) from the plasma, especially when a low thermal mass medium like helium is chosen as the coolant. Therefore, heat transfer enhancement in which the convective heat transfer rate is augmented by the addition of turbulence-promoting structures becomes a key initiative for providing sufficient cooling capability with helium. Previously, computational fluid dynamics simulations had been performed on pipe flows with different transverse and longitudinal ribbed geometries at Oak Ridge National Laboratory to compare the enhancement performance among different ribbed geometries. Rib shape morphing had been conducted to obtain an optimized rib profile. In the work presented here, the adjoint method is adopted in the ANSYS Fluent solver for turbulence model augmentation, and the Generalized k-ω (GEKO) turbulence model is employed because of its ability of tuning the turbulence model. The Nusselt number and pressure drop obtained from the channel flow with bottom ribbed wall experiments are used as the targets. Sensitivity analysis provides information as guidance to improve the turbulence model accuracy. The augmented GEKO model is tuned for the studied ribbed channel geometry and flow conditions, providing improved predictive accuracy within this context. Extension to other configurations offers potential but may require additional tuning and validation.

Xu, Tracy [ORNL] (ORCID:0009000193700887)↗

Improved Cryostat for Cooling a Wide Panel

An improved cryostat has been developed for cooling a wide panel evenly over its surface to a temperature of -423 F (approximately equal to -253 C) by use of liquid helium. Originally, the cryostat was to be used in measuring apparent strains in wide aluminum/lithium panels as functions of temperature in order to develop data for temperature compensation of the readings of strain gauges on a tank containing liquid hydrogen. Relative to the cryostat used previously for this purpose, the improved cryostat can be prepared for a test in less time, and it loses less helium during each test. Each wide panel to be tested is instrumented with thermocouples in preparation for a test. The previous cryostat was made of two aluminum halves that, for each test, were sandwiched together and sealed around the instrumented wide panel to be tested. The panel was thus enclosed in a plenum. The cryostat and adjacent panel areas protruding from the cryostat were then coated with a thermally insulating foam. During a test, liquid helium was made to flow into the plenum through a port on the bottom. The helium vaporized and expanded, filling the plenum with cold helium gas, which eventually flowed out of the plenum through a port on the top. The nature of the flow was such that a significant portion of the helium did not come into contact with the wide panel; hence, cooling was less efficient than it might otherwise have been. After completion of each test, the foam and the cryostat were separated from the panel. The cryostat was cleaned and prepared for installation on another instrumented wide panel for the next test. It took 28 hours to install the cryostat onto the instrumented panel, apply the foam, and perform ancillary operations in preparation for a test. The volume of liquid helium consumed during each test was 750 liters. The improved cryostat (see figure) includes an upper section and a lower section, both of which include permanent housings made of a thermally insulating foam 2-in. (approximately equal to 5-cm) thick. A liquid-helium- injection manifold is attached to the inside of the top section. The bottom section includes an outlet for helium gas. The manifold contains slots that, when the cryostat is installed on the panel, are located approximately 1 in. (approximately equal to 2.5 cm) from the wide panel. The array of slots spans a substantial portion of the area of the panel. The top and bottom sections of the cryostat are sealed to the panel by use of polytetrafluoroethylene cord and aluminum tape. Liquid helium is fed into the manifold from the top. The helium leaves the manifold through the slots and thus impinges directly on the panel. Hence, all the helium entering the cryostat must come into contact with the panel before leaving the cryostat. After a test, the cryostat is removed from the panel and reinstalled onto another panel for the next test. Installation of the cryostat on an instrumented panel takes a negligible amount of time, in comparison with the 28 hours associated with the previous cryostat. The amount of liquid helium consumed during a test in the improved cryostat is 500 liters - 250 liters less than before.

Clifton, W. B.↗

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Thermal design of a Shuttle infrared telescope facility /SIRTF/

A thermal design concept has been developed for a cryogenically-cooled infrared telescope facility which will be carried aboard the Space Shuttle for missions of 14 to 30 days. Supercitical helium at 6 K is the principal coolant. Auxiliary tanks of superfluid helium at 2 K are utilized to provide additional low-temperature cooling requirements of specific instruments. The preliminary thermal design described enables SIRTF to provide the low-temperature environment for the telescope and instruments, while maintaining thermally-induced optical degradations within acceptable limits with a cryogen utilization rate compatible with weight and volumetric constraints.

Stoll, R.↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Milestone 2.8: Preliminary Radiolytic Gas Generation Measurements from Helium-Backfilled Samples

The Department of Energy (DOE) is currently managing nearly 13 metric tons of aluminum-clad spent nuclear fuel (ASNF) with the intention of extended (> 50 years) dry storage in helium-backfilled canisters. Due to in-reactor and cooling pond conditions, oxyhydroxide corrosion layers have formed on the surface of the ASNF elements. These corrosion layers are susceptible to radiolysis and the formation of molecular hydrogen gas (H 2 ) due to the fuel’s inherent radiation field. Consequently, a rigorous evaluation of the effect of helium gas on radiolytic H 2 production is necessary to support the Technical Considerations and Challenges for Extended (> 50 yrs) Dry Storage of ASNF program, especially as previous Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution work demonstrated a significant effect of gas composition on the radiolytic yield (G-value) of H 2 . Here we report preliminary G-values for the radiolytic formation of H 2 from the gamma irradiation of pre-corroded aluminum alloy 1100 coupons flame sealed in helium environments. Irradiations yielded G(H 2 ) values of (5.1 ± 0.5) x 10 –4 and (9.4 ± 0.9) x 10 –4 µmol J –1 for pristine coupons, and (10.1 ± 0.4) x 10 –4 and (15.1 ± 1.2) x 10 –4 µmol J –1 for pre-corroded coupons for 0% and 50% relative humidity, respectively. These helium environment G(H 2 ) values are between 28% and 58% higher than previously reported values for argon environments. This enhancement is attributed to the significant difference in first ionization energy between helium (24.59 eV) and argon (15.76) facilitating additional processes, e.g., Penning ionization. These new preliminary helium environment G(H 2 ) values will be employed by Task 3 - Sealed and Vented System Episodic Breathing and Gas Generation Prediction to model the effect of radiolytic H 2 accumulation in helium environments to evaluate the practicality of the extended storage standard canister design.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Manufacturing High-Quality Carbon Nanotubes at Lower Cost

A modified electric-arc welding process has been developed for manufacturing high-quality batches of carbon nanotubes at relatively low cost. Unlike in some other processes for making carbon nanotubes, metal catalysts are not used and, consequently, it is not necessary to perform extensive cleaning and purification. Also, unlike some other processes, this process is carried out at atmospheric pressure under a hood instead of in a closed, pressurized chamber; as a result, the present process can be implemented more easily. Although the present welding-based process includes an electric arc, it differs from a prior electric-arc nanotube-production process. The welding equipment used in this process includes an AC/DC welding power source with an integral helium-gas delivery system and circulating water for cooling an assembly that holds one of the welding electrodes (in this case, the anode). The cathode is a hollow carbon (optionally, graphite) rod having an outside diameter of 2 in. (approximately equal to 5.1 cm) and an inside diameter of 5/8 in. (approximately equal to 1.6 cm). The cathode is partly immersed in a water bath, such that it protrudes about 2 in. (about 5.1 cm) above the surface of the water. The bottom end of the cathode is held underwater by a clamp, to which is connected the grounding cable of the welding power source. The anode is a carbon rod 1/8 in. (approximately equal to 0.3 cm) in diameter. The assembly that holds the anode includes a thumbknob- driven mechanism for controlling the height of the anode. A small hood is placed over the anode to direct a flow of helium downward from the anode to the cathode during the welding process. A bell-shaped exhaust hood collects the helium and other gases from the process. During the process, as the anode is consumed, the height of the anode is adjusted to maintain an anode-to-cathode gap of 1 mm. The arc-welding process is continued until the upper end of the anode has been lowered to a specified height above the surface of the water bath. The process causes carbon nanotubes to form in the lowest 2.5 cm of the anode. It also causes a deposit reminiscent of a sandcastle to form on the cathode. The nanotube-containing material is harvested. The cathode and anode can then be cleaned (or the anode is replaced, if necessary) and the process repeated to produce more nanotubes. Tests have shown that the process results in approximately equal to 50-percent yield of carbon nanotubes (mostly of the single-wall type) of various sizes. Whereas the unit cost of purified single-wall carbon nanotubes produced by other process is about $1,000/g in the year 2000, it has been estimated that for the present process, the corresponding cost would be about $10/g.

Benavides, Jeanette M.↗