Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Evaluation of the heat transfer module (FAHT) of Failure Analysis Nonlinear Thermal And Structural Integrated Code (FANTASTIC)

The heat transfer module of FANTASTIC Code (FAHT) is studied and evaluated to the extend possible during the ten weeks duration of this project. A brief background of the previous studies is given and the governing equations as modeled in FAHT are discussed. FAHT's capabilities and limitations based on these equations and its coding methodology are explained in detail. It is established that with improper choice of element size and time step FAHT's temperature field prediction at some nodes will be below the initial condition. The source of this unrealistic temperature prediction is identified and a procedure is proposed for avoiding this phenomenon. It is further shown that the proposed procedure will converge to an accurate prediction upon mesh refinement. Unfortunately due to lack of time FAHT's ability to accurately account for pyrolysis and surface ablation has not been verified. Therefore, at the present time it can be stated with confidence that FAHT can accurately predict the temperature field for a transient multi-dimensional, orthotropic material with directional dependence, variable property, with nonlinear boundary condition. Such a prediction will provide an upper limit for the temperature field in an ablating decomposing nozzle liner. The pore pressure field, however, will not be known.

Keyhani, Majid↗

Southern Ocean Heat Storage, Reemergence, and Winter Sea Ice Decline Induced by Summertime Winds

The observational record shows a substantial 40-yr upward trend in summertime westerly winds over the Southern Ocean, as characterized by the southern annular mode (SAM) index. Enhanced summertime westerly winds have been linked to cold summertime sea surface temperature (SST) anomalies. Previous studies have suggested that Ekman transport or upwelling is responsible for this seasonal cooling. Here, another process is presented in which enhanced vertical mixing, driven by summertime wind anomalies, moves heat downward, cooling the sea surface and simultaneously warming the subsurface waters. The anomalously cold SSTs draw heat from the atmosphere into the ocean, leading to increased depth-integrated ocean heat content. The subsurface heat is returned to the surface mixed layer during the autumn and winter as the mixed layer deepens, leading to anomalously warm SSTs and potentially reducing sea ice cover. Observational analyses and numerical experiments support our proposed mechanism, showing that enhanced vertical mixing produces subsurface warming and cools the surface mixed layer. Nevertheless, the dominant driver of surface cooling remains uncertain; the relative importance of advective and mixing contributions to the surface cooling is model dependent. Modeling results suggest that sea ice volume is more sensitive to summertime winds than sea ice extent, implying that enhanced summertime westerly winds may lead to thinner sea ice in the following winter, if not lesser ice extent. Thus, strong summertime winds could precondition the sea ice cover for a rapid retreat in the following melt season.

Southern Ocean↗

Micro-scale heat-exchangers for Joule-Thomson cooling.

This project focused on developing a micro-scale counter flow heat exchangers for Joule-Thomson cooling with the potential for both chip and wafer scale integration. This project is differentiated from previous work by focusing on planar, thin film micromachining instead of bulk materials. A process will be developed for fabricating all the devices mentioned above, allowing for highly integrated micro heat exchangers. The use of thin film dielectrics provides thermal isolation, increasing efficiency of the coolers compared to designs based on bulk materials, and it will allow for wafer-scale fabrication and integration. The process is intended to implement a CFHX as part of a Joule-Thomson cooling system for applications with heat loads less than 1mW. This report presents simulation results and investigation of a fabrication process for such devices.

Gross, Andrew John↗

Joule heating in the mesosphere and thermosphere during the July 13, 1982, solar proton event

The solar proton event of July 13, 1982 produced considerable ionization in the polar-cap mesosphere. Energetic solar proton fluxes were measured by the NOAA-6 satellite. The DE-2 satellite measured the low-energy electrons, the ion drift velocity, and other atmospheric and ionospheric properties during the event in the region of the measured maximum electric field (189 mV/m at 2215 UT near 60 deg N), a Joule heating rate of 1-3 K/day is calculated between 70 and 80 km, exceeding the heating due to ozone absorption at noon in the summer hemisphere in that altitude range. The Joule heating rate above 90 km greatly exceeded 20 K/day. The calculated height-integrated Joule heating rate above 100 km in the same region exceeded 400 ergs/sq cm sec, and DE-2 near 350 km measured neutral winds of nearly 1000 m/s and neutral gas temperatures of over 2000 K. The overall ionospheric structure calculated below the DE-2 satellite is described.

Roble, R. G.↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

The thermosphere of Titan

The vertical structure of Titan's thermosphere is calculated down to the mesopause as a function of local time based on Voyager 1 occultation data. The thermal time scales that characterize the diurnal behavior of the thermosphere are discussed, the input model atmosphere used to calculate the temperature profile is presented, and the dominant heating and cooling mechanisms in the thermosphere are examined. The temperature profiles obtained by integrating the heat transfer equation with and without electron heating are presented and discussed. The implications that derived exospheric temperatures have for the neutral hydrogen torus are investigated. The diurnal exospheric temperature is unlikely to exceed 225 K, averages between 187 and 197 K, and has a variational amplitude of 28 K or less. The vertical extent of the hydrogen cloud is too large to be explained in terms of simple thermal escape of hydrogen from the exosphere.

Friedson, A. J.↗

Integrated electron beam tip and sample heating device for a scanning tunneling microscope

An electron beam heating device with the temperature up to 2200 K is provided for heating a sample and a tip for a scanning tunneling microscope (STM). The electron beam heating device includes a base stage for mating respectively with an electron beam sample heating carrier and an electron beam tip heating carrier, both carriers include a filament. The integration of the filament into the transferable electron beam sample heating carrier and electron beam tip heating carrier enables filament exchange without venting the vacuum system. A fixed distance between the sample and the filament enables reproducible sample temperature control and the filament is mounted at a back of the sample, allowing optical access for temperature measurement, and allowing sample preparation processes without changing positions of the sample or the filament. Once the tip is loaded, a fixed relative position between the tip and the filament enables reproducible control of heating. A tip holder includes an electrically isolated post connected to the tip, enabling a separate electrical potential to be applied to the tip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ELM and inter-ELM heat and particle flux to a secondary divertor in the DIII-D tokamak

DIII-D ELMing discharges with a secondary X-point (XPT) inside the vessel were used to evaluate the power distribution between the primary and secondary divertors. The magnetic balance, defined by the distance between the primary and secondary separatrices at the outer midplane (dRsep), was varied from -5 mm (lower-single-null, LSN) to +16 mm (upper-single-null, USN). In this work, we find that the secondary divertor receives up to 1/3 of the total heat flux (primary + secondary divertors), and it is dominated by the ELM-driven flux. Both the radially-integrated and the peak heat flux to the secondary divertor decay below ~50% of the maximum as dRsep is varied from -5 to +6mm, but the integrated heat flux decay flattens out and it would take dRsep above ~25mm to reduce the ELM heat flux to the secondary divertor below 10% of the one deposited to a well-defined SN. Both the secondary inner and outer strike points receive heat flux during ELMs. The peak heat flux is comparable in both strike points for dRsep < 10mm, but the inner strike point receives less than 15% of the total flux. Furthermore, this is experimental evidence that the secondary inner divertor region receives significant ELM flux which should be taken into account for the design of future generation tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inner Magnetospheric Superthermal Electron Transport: Photoelectron and Plasma Sheet Electron Sources

Two time-dependent kinetic models of superthermal electron transport are combined to conduct global calculations of the nonthermal electron distribution function throughout the inner magnetosphere. It is shown that the energy range of validity for this combined model extends down to the superthermal-thermal intersection at a few eV, allowing for the calculation of the en- tire distribution function and thus an accurate heating rate to the thermal plasma. Because of the linearity of the formulas, the source terms are separated to calculate the distributions from the various populations, namely photoelectrons (PEs) and plasma sheet electrons (PSEs). These distributions are discussed in detail, examining the processes responsible for their formation in the various regions of the inner magnetosphere. It is shown that convection, corotation, and Coulomb collisions are the dominant processes in the formation of the PE distribution function and that PSEs are dominated by the interplay between the drift terms. Of note is that the PEs propagate around the nightside in a narrow channel at the edge of the plasmasphere as Coulomb collisions reduce the fluxes inside of this and convection compresses the flux tubes inward. These distributions are then recombined to show the development of the total superthermal electron distribution function in the inner magnetosphere and their influence on the thermal plasma. PEs usually dominate the dayside heating, with integral energy fluxes to the ionosphere reaching 10(exp 10) eV/sq cm/s in the plasmasphere, while heating from the PSEs typically does not exceed 10(exp 8) eV/sq cm/s. On the nightside, the inner plasmasphere is usually unheated by superthermal electrons. A feature of these combined spectra is that the distribution often has upward slopes with energy, particularly at the crossover from PE to PSE dominance, indicating that instabilities are possible.

Khazanov, G. V.↗

Inner Magnetospheric Superthermal Electron Transport: Photoelectron and Plasma Sheet Electron Sources

Two time-dependent kinetic models of superthermal electron transport are combined to conduct global calculations of the nonthermal electron distribution function throughout the inner magnetosphere. It is shown that the energy range of validity for this combined model extends down to the superthermal-thermal intersection at a few eV, allowing for the calculation of the entire distribution function and thus an accurate heating rate to the thermal plasma. Because of the linearity of the formulas, the source terms are separated to calculate the distributions from the various populations, namely photoelectrons (PEs) and plasma sheet electrons (PSEs). These distributions are discussed in detail, examining the processes responsible for their formation in the various regions of the inner magnetosphere. It is shown that convection, corotation, and Coulomb collisions are the dominant processes in the formation of the PE distribution function, and that PSEs are dominated by the interplay between the drift terms. Of note is that the PEs propagate around the nightside in a narrow channel at the edge of the plasmasphere as Coulomb collisions reduce the fluxes inside of this and convection compresses the flux tubes inward. These distributions are then recombined to show the development of the total superthermal electron distribution function in the inner magnetosphere and their influence on the thermal plasma. PEs usually dominate the dayside heating, with integral energy fluxes to the ionosphere reaching 10(exp 10) eV/sq cm/s in the plasmasphere, while heating from the PSEs typically does not exceed 10(exp 8)eV/sq cm/s. On the nightside, the inner plasmasphere is usually unheated by superthermal electrons. A feature of these combined spectra is that the distribution often has upward slopes with energy, particularly at the crossover from PE to PSE dominance, indicating that instabilities are possible.

Khazanov, G. V.↗

A New Framework for Combining a Condenser and Reboiler in a Configuration To Consolidate Distillation Columns

Heat and mass integration to consolidate distillation columns in a configuration is often characterized by elimination of a reboiler and condenser associated with the same components. We study a new and more general approach to column consolidation, of which the conventional approach is a special case. In the new approach, the reboiler of a column is coupled with the condenser of another, through heat and mass integration in an additional section (HMA-section). The introduction of an HMA-section eliminates multiple connecting streams/valves, reduces the number of reboilers, condensers, and distillation columns by one each, and reduces the heat duty of the configuration. We exhaustively enumerate HMA-sections, and lay out a framework to identify all configurations with HMA-sections. Through examples, we show that both heat integration and mass integration resulting from introducing an HMA-section contribute to reduce the heat duty significantly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aerothermodynamic design considerations of an aerobraked spacecraft

The major aerothermodynamic design issues that influenced the VOIR (Venus Orbiting Image Radar) airbrake and mission design are discussed. In the discussion of aerobrake heating, it is pointed out that the heat transfer to the deployed aerobrake is a function of the flow regime encountered during the periapsis pass, the perapsis altitude, and the brake surface geometry. The discussion of spacecraft thermal protection encompasses separated flow heating, aerobrake backface radiation, total solar cell heating, and undeployed aerobrake effects. The aerobrake is designed to protect the spacecraft thermally by limiting the integrated entry heating to the critical solar cell arrays (located on three sides of the spacecraft) due to flow impingement heating, separated flow heating, and backface radiation heating. It is explained that these design considerations led to the selection of a flat-faced aerobrake design located on the front of the spacecraft to provide maximum spacecraft thermal protection. The 8.4-m equivalent diameter aerobrake eliminates direct flow impingement heating and lowers separated flow heating on the spacecraft.

Florence, D.↗

Mars Propellant Liquefaction Modeling in Thermal Desktop

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

Cryogenics↗

Active thermal control systems for lunar and Martian exploration

Several ATCS options including heat pumps, radiator shading devices, and single-phase flow loops were considered. The ATCS chosen for both lunar and Martian habitats consists of a heat pump integral with a nontoxic fluid acquisition and transport loop, and vertically oriented modular reflux-boiler radiators. The heat pump operates only during the lunar day. The lunar and Martian transfer vehicles have an internal single-phase water-acquisition loop and an external two-phase ammonia rejection system with rotating inflatable radiators. The lunar and Martian excursion vehicles incorporate internal single-phase water acquisition, which is connected via heat exchangers to external body-mounted single-phase radiators. A water evaporation system is used for the transfer vehicles during periods of high heating.

Ewert, Michael K.↗