Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A model to assess Zircaloy’s mechanical property changes following a transient beyond critical heat flux

Maintaining the integrity of nuclear fuel rods is essential for ensuring public health and safety in nuclear power generation. During reactor operation, this integrity is confirmed by demonstrating compliance with established regulatory acceptance criteria. For moderate-frequency events, such as limiting transients and anticipated operational occurrences (AOOs), the current fuel integrity criterion is based on preventing boiling transition. This criterion assumes that prevention of boiling transition will prevent excessive cladding heating and, thus, fuel failure during normal operations. While conservative, this approach places significant constraints on core design, fuel cycle economics, and a plant’s ability to perform major power uprates, leading to suboptimal fuel utilization and inefficient carbon-free energy production. A more efficient approach could be achieved by revising the failure criterion to a material-specific limit rather than strictly preventing the boiling transition, since boiling transition per se is not a cause of fuel cladding failure. Here, as a result, a new licensing framework based on material properties, termed time-at-temperature (t@T), is needed. This approach would allow for brief periods of post–critical heat flux operation during an AOO without compromising safety. Implementing the t@T licensing strategy requires a robust technical foundation in material properties, which must be established through comprehensive data collection on both unirradiated and irradiated fuel and cladding materials. This foundation would enable the development of a safety basis that ensures safe operation while providing greater flexibility and efficiency for reactor operation. This paper documents a thorough review of the available data to establish a baseline knowledge that can inform the development of cladding mechanical models, as well as identify experimental data gaps that need to be addressed in future research. Machine learning and data informatics were utilized to extract the importance of parameters on the t@T parameter. Industry tools were used to perform baseline analyses to define the relevant transient conditions for data analysis. The subsequent review successfully identified applicable experimental data, as well as sufficient data to evaluate changes in cladding mechanical properties following an AOO transient. Rather than developing new models, this work coupled existing irradiation annealing and recrystallization models to calculate changes in hardness, yield stress, and ultimate tensile stress following an AOO event. The findings from this review were summarized to highlight the experimental data needs required to fill remaining gaps and support the development of future t@T licensing methodologies.

Cladding performance↗

The turbulent mean-flow, Reynolds-stress, and heat flux equations in mass-averaged dependent variables

The time-dependent, turbulent mean-flow, Reynolds stress, and heat flux equations in mass-averaged dependent variables are presented. These equations are given in conservative form for both generalized orthogonal and axisymmetric coordinates. For the case of small viscosity and thermal conductivity fluctuations, these equations are considerably simpler than the general Reynolds system of dependent variables for a compressible fluid and permit a more direct extension of low speed turbulence modeling to computer codes describing high speed turbulence fields.

Rubesin, M. W.↗

Experimental study of thermocapillary flows in a thin liquid layer with heat fluxes imposed on the free surface

To study thermocapillary flows in a two-dimensional thin liquid layer with heat fluxes imposed on the free surface experimentally, a long tray configuration was employed to simulate the infinite layer. The surface temperature distribution due to thermocapillary convective for different flow regimes was measured and compared with theoretical predictions. A short tray configuration was also employed to study the end wall effects (insulating or conducting). The results show that for a strong convection flow with an insulating wall as the boundary the surface temperature distribution became quite uniform. Consequently, the thermocapillary driving force was greatly reduced. On the other hand, a strong fluid motion always existed adjacent to the conducting wall because of the large surface temperature gradient near the wall.

Lai, Chun-Liang↗

Experimental study of thermocapillary flows in a thin liquid layer with heat fluxes imposed on the free surface

To study thermocapillary flows in a two-dimensional thin liquid layer with heat fluxes imposed on the free surface experimentally, a long tray configuration was employed to simulate the infinite layer. The surface temperature distribution due to thermocapillary convection for different flow regimes was measured and compared with theorectical predictions. A short tray configuration was also employed to study the end wall effects (insulating or conducting). The results show that, for a strong convection flow with an insulating wall as the boundary, the surface temperature distribution became quite uniform. Consequently, the thermocapillary driving force was greatly reduced. On the other hand, a strong fluid motion always existed adjacent to the conducting wall because of the large surface temperature gradient near the wall.

Lai, Chun-Liang↗

Development of a silicone ablator for high-heat-flux and high-shear-rate condition

A silicone material was developed which gives suitable ablative protection in the high heat flux, high shear environments encountered in severe reentry applications, such as nose cones for ballistic vehicles and protection of leading edges or other critical areas of a vehicle. In addition, the ease of handling, low application cost, and room temperature cure make such a silicon material suitable nozzles for the large rockets necessary for vehicle launching. The development of this product is traced from the selection of suitable polymers through the choice of fillers and the finalization of filler loadings.

Campbell, R. A.↗

Bidirectional solar wind electron heat flux events

ISEE 3 plasma and magnetic field data are used here to document the general characteristics of bidirectional electron heat flux events (BEHFEs). Significant field rotations often occur at the beginning and/or end of such events and, at times, the large-field rotations characteristic of 'magnetic clouds' are present. Approximately half of all BEHFEs are associated with and follow interplanetary shocks, while the other events have no obvious shock associations. When shock-associated, the delay from shock passage typically is about 13 hours, corresponding to a radial separation of about 0.16 AU. When independent of any shock association, BEHFEs typically are about 0.13 AU thick in the radial direction. It is suggested that BEHFEs are one of the more prominent signatures of coronal mass ejection events in the solar wind at 1 AU.

Gosling, J. T.↗

Investigation of Critical Heat Flux in Reduced Gravity Using Photomicrographic Techniques

Experiments were performed to examine the effects of body force on flow boiling critical heat flux (CHF). FC-72 was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface just prior to CHF. High-speed video imaging techniques were used to identify dominant CHF mechanisms corresponding to different flow orientations and liquid velocities. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed significant sensitivity to orientation for flow velocities below 0.2 m/s, where extremely low CHF values where measured, especially with downward-facing heated wall and downflow orientations. High flow velocities dampened the effects of orientation considerably. The CHF data were used to assess the suitability of previous CHF models and correlations. It is shown the Interfacial Lift-off Model is very effective at predicting CHF for high velocities at all orientations. The flooding limit, on the other hand, is useful at estimating CHF at low velocities and for downflow orientations. A new method consisting of three dimensionless criteria is developed for determining the minimum flow velocity required to overcome body force effects on near-saturated flow boiling CHF. Vertical upflow boiling experiments were performed in pursuit of identifying the trigger mechanism for subcooled flow boiling CHF. While virtually all prior studies on flow boiling CHF concern the prediction or measurement of conditions that lead to CHF, this study was focused on events that take place during the CHF transient. High-speed video imaging and photomicrographic techniques were used to record the transient behavior of interfacial features from the last steady-state power level before CHF until the moment of power cut-off following CHF. The video records show the development of a wavy vapor layer which propagates along the heated wall, permitting cooling prior to CHF only in wetting fronts corresponding to the wave troughs. Image analysis software was developed to estimate void fraction from the individual video images. The void fraction records for subcooled flow boiling show the CHF transient is accompanied by gradual lift-off of wetting fronts culminating in some maximum vapor layer mean thickness, following which the vapor layer begins to thin down as the transition to film boiling ensues. This study proves the Interfacial Lift-off Model, which has been validated for near-saturated flow boiling CHF, is equally valid for subcooled conditions.

Mudawar, Issam↗

Characteristics of grassy ELMs and their impact on the divertor heat flux width

We report BOUT++ turbulence simulations are conducted for a 60 s steady-state long pulse high β p EAST grassy ELM discharge. BOUT++ linear simulations show that the unstable mode spectrum covers a range of toroidal mode numbers from low-n (n = 10–15) peeling–ballooning modes (P–B) to high-n (n = 40–80) drift-Alfvén instabilities. Nonlinear simulations show that the ELM crash is triggered by low-n peeling modes and fluctuation is generated at the peak pressure gradient position and radially spread outward into the scrape-off-layer, even though the drift-Alfvén instabilities dominate the linear growth phase. However, drift-Alfvén turbulence delays the onset of the grassy ELM and enhances the energy loss with the fluctuation extending to pedestal top region. Simulations further show that if the peeling drive is removed, the fluctuation amplitude drops by an order of magnitude and the ELM crashes disappear. The divertor heat flux width is ~2 times larger than the estimates based on the HD model and the Eich's ITPA multi-tokamak scaling (or empirical Eich scaling) due to the strong radial turbulence transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A network of soil moisture, soil temperature, air temperature, net radiation, ground heat flux and ground water for Chicago, Illinois

This dataset contains environmental monitoring data collected using solar-powered Multi-Function Research (MFR) Long Range Wide Area (LoRaWAN)-enabled nodes at 11 sites in Chicago, Illinois, as part of the DOE Urban Integrated Field Lab CROCUS project. The MFR node system consists of an Input/Output Digital Input Module (IB8) interface box (ICT International) providing wired connections for environmental sensors and an MFR-Node-L data logger that manages power, data processing, and LoRaWAN communication. The wireless data are ingested via Sage network (https://sagecontinuum.org/) nodes that contain LoRaWAN antennae. Measurements were collected from 11 MFR nodes deployed across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), West Woodlawn "Blacks in Green" (BIG), and Indian Boundary Prairies (IBP). Each MFR node supports a consistent suite of sensors measuring atmospheric, soil, and hydrological variables. Atmospheric measurements include 2m air temperature (°C), 2m vapor pressure deficit (kPa), and 2m shortwave/longwave radiation (incoming and outgoing, W/m²) measured using ATH-VPD and Apogee SN500 sensors. Soil measurements include volumetric water content (VWC, %) and temperature (°C) at four depths (15, 30, 45, and 60 cm below surface) using Meter Teros54 sensors, and heat flux (W/m²) at 10 cm depth using Huske HFP01-05 sensors. At selected locations, Meter Hydros21 sensors measure groundwater depth (mm), specific conductivity (dS/m), and temperature (°C). The dataset includes timestamps, site identifiers with location names, device IDs, Global Positioning System (GPS) coordinates, variable names with units, measurement depths, values, sensor names, and Sage node identifiers. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 6-bit binary system indicating physical range violations, step spikes, 24-hour flat-line conditions, 6-hour jitter, 7-day ultra-low variance, and persistent high offset. Data is provided in CSV and CF-compliant NetCDF formats. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Sap Flow Meter (SFM1x) sensors.

Chicago↗

Critical Heat Flux of Liquid Hydrogen, Liquid Methane, and Liquid Oxygen: A Review of Available Data and Predictive Tools

Available experimental data dealing with critical heat flux (CHF) of liquid hydrogen (LH 2 ), liquid methane (LCH 4 ), and liquid oxygen (LO 2 ) in pool and flow boiling are compiled. The compiled data are compared with widely used correlations. Experimental pool boiling CHF data for the aforementioned cryogens are scarce. Based on only 25 data points found in five independent sources, the correlation of Sun and Lienhard (1970) is recommended for predicting the pool CHF of LH 2 . Only two experiments with useful CHF data for the pool boiling of LCH 4 could be found. Four different correlations including the correlation of Lurie and Noyes (1964) can predict the pool boiling CHF of LCH 4 within a factor of two for more than 70% of the data. Furthermore, based on the 19 data points taken from only two available sources, the correlation of Sun and Lienhard (1970) is recommended for the prediction of pool CHF of LO 2 . Flow boiling CHF data for LH 2 could be found in seven experimental studies, five of them from the same source. Based on the 91 data points, it is suggested that the correlation of Katto and Ohno (1984) be used to predict the flow CHF of LH 2 . No useful data could be found for flow boiling CHF of LCH 4 or LO 2 . The available databases for flow boiling of LCH 4 and LO 2 are generally deficient in all boiling regimes. This deficiency is particularly serious with respect to flow boiling.

Multi-Phase Flow↗

Critical Heat Flux of Liquid Hydrogen, Liquid Methane, and Liquid Oxygen: A Review of Available Data and Predictive Tools

Available experimental data dealing with critical heat flux (CHF) of liquid hydrogen (LH2), liquid methane (LCH4), and liquid oxygen (LO2) in pool and flow boiling are compiled. The compiled data are compared with widely used correlations. Experimental pool boiling CHF data for the aforementioned cryogens are scarce. Based on only 25 data points found in five independent sources, the correlation of Sun and Lienhard (1970) is recommended for predicting the pool CHF of LH2. Only two experiments with useful CHF data for the pool boiling of LCH4 could be found. Four different correlations including the correlation of Lurie and Noyes (1964) can predict the pool boiling CHF of LCH4 within a factor of two for more than 70% of the data. Furthermore, based on the 19 data points taken from only two available sources, the correlation of Sun and Lienhard (1970) is recommended for the prediction of pool CHF of LO2. Flow boiling CHF data for LH2 could be found in seven experimental studies, five of them from the same source. Based on the 91 data points, it is suggested that the correlation of Katto and Ohno (1984) be used to predict the flow CHF of LH2. No useful data could be found for flow boiling CHF of LCH4 or LO2. The available databases for flow boiling of LCH4 and LO2 are generally deficient in all boiling regimes. This deficiency is particularly serious with respect to flow boiling.

Multi-Phase Flow↗