Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Grey-box and ANN-based building models for multistep-ahead prediction of indoor temperature to implement model predictive control

Model-based predictive control (MPC) strategies for heating, ventilation, and air-conditioning (HVAC) systems present an opportunity to lower building energy consumption and operational costs. Such approaches rely on the development of a model to precisely forecast building thermal dynamics, such as room air temperature or heating/cooling rate, and make control-related decisions. The control-oriented modeling of building energy systems should be accurate in predicting indoor conditions and present low computational complexity. These features are the key challenge of implementing advanced control methods such as MPC. Extant studies on building modeling for MPC have focused on step-ahead forecasting techniques to forecast building thermal dynamics, while multistep-ahead forecasting is essential. Moreover, machine learning model suitable in case of the domain-based engineering expertise are also not available. To this aim, we perform a comparative analysis of the grey-box model based on a resistance-capacitance (RC) thermal network and a machine learning model composed of an artificial neural network (ANN) for multistep-ahead prediction of building thermal dynamics using current and historical data. Actual experimental data obtained from the Flexible Research Platform (FRP) in Oak Ridge National Laboratory (US) are used for estimation and validation purposes. The average root mean squared error (RMSE) of the grey-box and ANN models are 0.89 °C and 1.02°C, respectively. Finally, the results indicate that the grey-box model outperforms the ANN model in the considered validation periods in terms of accuracy and prediction stability.

42 ENGINEERING↗

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

Characterization of the indoor far-field aerosol transmission in a model commercial office building

As businesses gradually reopen and employees return to work, the potential spread of SARS-CoV-2 and its variants through airborne transmission via the heating, ventilation, and air-conditioning (HVAC) systems of commercial building raises concerns. Since the general practice in commercial buildings is to use low-efficiency air filters and given that indoor air is generally recycled, the degree to which cross-zone aerosol transmission occurs is of interest. To quantify the cross-zone aerosol transmission, experiments were conducted using a synthetic test aerosol in the five zones on the first floor of a model commercial office building at the Oak Ridge National Laboratory. Because the synthetic aerosol was tagged with fluorescent salt, the aerosol generated from the source zone can be distinguished from the background aerosols due to its unique fluorescent signal. Data from cross-zone campaigns showed that submicron-aerosol transmission was higher than the micron aerosols. In campaigns with doors closed, the submicron aerosol transmission was less than 16% and less than 11% for micron aerosol transmission. Finally, opening the interior doors that connecting different zones can significantly enhance the aerosol transmission for zones at the close proximity to the source, but has less impact on those farther away.

60 APPLIED LIFE SCIENCES↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In Tube Condensation Heat Transfer and Pressure Drop for R454B and R32—Potential Replacements for R410A

The heating, ventilation and air conditioning (HVAC) industry in the United States seeks near-term alternative refrigerants to replace R-410A in unitary equipment. Two potential replacement refrigerants are R-454B and R-32. It is of interest to investigate the capability and accuracy of existing heat exchanger design methods when applied to these replacement refrigerants. To that end, this work presents empirical condensation quasi-local heat transfer coefficient and pressure drop data for R-454B and R-32. These data were obtained in a $\frac{3}{8}$ in. (9.52 mm) outside diameter (OD) smooth copper tube with a wall thickness of 0.032 in. (0.81 mm). The experimental variables and their ranges included refrigerant absolute pressure ( 1960 ≤ P a b s ≤ 3196 kPa), condensation temperature ( 35 ≤ T c o n d ≤ 50 °C), mass flux ( 100 ≤ G ≤ 200 kg m -2 s -1 ), vapor quality ( 0 ≤ x ≤ 1 ), and heat flux ( 32.9 ≤ q ″ ≤ 62.97 kW m -2 ). It was found that the heat transfer correlation developed by Cavallini et al. Cavallini et al. (2006) predicted the experimental condensation heat transfer data, for both R-454B and R-32, with the greatest accuracy. Using the Cavallini et al. correlation, it was found that the mean absolute percentage error (MAPE) was 10.5% and 15.1% for R-454B and R-32, respectively. Additionally, the pressure drop correlation developed by Friedel Friedel (1979) predicted the experimentally determined pressure gradient with a MAPE of 7.7% and 5.5% for R-454B and R-32, respectively. These results will assist the practicing thermal engineer to choose the most appropriate design correlation for these near-term replacement refrigerants.

42 ENGINEERING↗

Reducing the cost of home energy upgrades in the US: An industry survey

Decarbonizing the US residential building stock requires a substantial acceleration in home energy upgrades. Numerous barriers exist to accelerating adoption of efficient and electric building technologies, but foremost among these is high upfront costs. This study uses an industry survey delivered to a sample of home energy professionals to examine promising cost reduction strategies across a range of project types, including HVAC, water heating, and envelope/insulation projects. The survey included quantitative and qualitative questions to collect evidence on the estimated cost reduction potential of these strategies and their likelihood of use in the construction industry. The 167 survey respondents included contractors, energy consultants, architects, manufacturers, and others with experience in delivering energy upgrades in single-family and multifamily buildings in the US. Results show that significant cost reductions are achievable by minimizing additional infrastructure costs (such as replacing electric panels), streamlining project planning/management, and deploying innovations that simplify installation. We find that for a typical deep retrofit project, including heat pumps for space and water heating in addition to envelope upgrades, the strategies could result in a total installed cost reduction of nearly 50%, dramatically improving the customer economics of such a project. This research makes a novel contribution to the literature on strategies to reduce the costs of residential retrofits. We discuss how our study's insights on the highest-value cost reduction strategies for home energy upgrades can further accelerate their uptake in the US housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An overview of data tools for representing and managing building information and performance data

Building information modeling (BIM) has been widely adopted for representing and exchanging building data across disciplines during building design and construction. However, BIM's use in the building operation phase is limited. With the increasing deployment of low-cost sensors and meters, as well as affordable digital storage and computing technologies, growing volumes of data have been collected from buildings, their energy services systems, and occupants. Such data are crucial to help decision makers understand what, how, and when energy is consumed in buildings—a critical step to improving building performance for energy efficiency, demand flexibility, and resilience. However, practical analyses and use of the collected data are very limited due to various reasons, including poor data quality, ad-hoc representation of data, and lack of data science skills. To unlock value from building data, there is a strong need for a toolchain to curate and represent building information and performance data in common standardized terminologies and schemas, to enable interoperability between tools and applications. This study selected and reviewed 24 data tools based on common use cases of data across the building life cycle, from design to construction, commissioning, operation, and retrofits. The selected data tools are grouped into three categories: (1) data dictionary or terminology, (2) data ontology and schemas, and (3) data platforms. The data are grouped into ten typologies covering most types of data collected in buildings. This study resulted in five main findings: (1) most data representation tools can represent their intended data typologies well, such as Green Button for smart meter data and Brick schema for metadata of sensors in buildings and HVAC systems, but none of the tools cover all ten types of data; (2) there is a need for data schemas to represent the basis of design data and metadata of occupant data; (3) standard terminologies such as those defined in BEDES are only adopted in a few data tools; (4) integrating data across various stages in the building life cycle remains a challenge; and (5) most data tools were developed and maintained by different parties for different purposes, their flexibility and interoperability can be improved to support broader use cases. Finally, recommendations for future research on building data tools are provided for the data and buildings community based on the FAIR principles to make data Findable, Accessible, Interoperable, and Reusable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of future weather data for assessing climate change impacts on buildings and energy systems

The effectiveness of climate change impact assessments and the development of adaptation strategies depend on the availability of high-quality future weather data. However, significant gaps exist between the needs of the energy research community and the focus of the climate modeling community, primarily due to a historical lack of communication and collaboration between the two groups. Here, to address this issue, this work provides a comprehensive overview of the critical aspects involved in creating future weather data for building and energy system modeling, including emissions scenarios, general circulation models, downscaling methods, categories of future weather data, and uncertainties in climate simulations. Moreover, it critically evaluates the applicability and suitability of various types of future weather data in five key application scenarios: energy use analysis, resilience analysis, HVAC design, utility-scale analysis, and renewable energy analysis. Finally, this work presents recommendations for high-level actions and research directions to foster collaboration between the energy research and climate modeling communities and to promote the integration of future weather data into energy codes and the design practices of buildings and energy systems.

Climate change↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Localized Actual Meteorological Year File Creator (LAF): A tool for using locally observed weather data in building energy simulations

The Localized Actual Meteorological Year File Creator (LAF) application provides web-based access to real meteorological data and processes it into a weather file suitable for building energy modeling. Building energy consumption is affected by what is inside the building (such as occupants, appliances, HVAC systems, etc.) and by what is outside: the weather conditions the building is exposed to. However, freely available weather data files are limited to a number of specific locations, usually airports, which are often located away from city centers where buildings are concentrated. The authors have developed a new tool that supports the investigation and quantification of micro-climate conditions on building energy consumption. LAF is built on the Python open-source programming language and has a Graphical User Interface (GUI) that allows users to create custom weather data files for building energy simulations. Many sets of actual meteorological year weather data for long time periods are publicly available online (such as the MesoWest database) for thousands of locations in the US. LAF selects weather data according to user specifications and automatically processes it through an API across multiple weather stations and multiple time periods. The user may easily select a specific location, time frame, and time step that best meets their needs. This article presents a useful tool for energy modelers, building designers and operators to assist with building performance analysis and optimization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗