Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Modernization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Detecting and mitigating abnormal events in large scale networks: budget constrained placement on smart grids

Several scenarios exist in the modern interconnected world which call for an efficient network interdiction algorithm. Applications are varied, including various monitoring and load shedding applications on large smart energy grids, computer network security, preventing the spread of Internet worms and malware, policing international smuggling networks, and controlling the spread of diseases. In this paper we consider some natural network optimization questions related to the budget constrained interdiction problem over general graphs, specifically focusing on the sensor/switch placement problem for large-scale energy grids. Many of these questions turn out to be computationally hard to tackle. We present a particular form of the interdiction question which is practically relevant and which we show as computationally tractable. A polynomial-time algorithm will be presented for solving this problem.

97 MATHEMATICS AND COMPUTING↗

Nondestructive measurement of the grid ratio using a single image

The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T{sub p}), and scatter transmission (T{sub s}). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53{+-}0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open-Source Architecture for Multi-Party Update Verification for Data Acquisition Devices

Power grids are integral parts of modern daily life and are increasingly under cyberattack. Common software update processes for grid control devices rely on only one organization to provide verification. This paper roposes a multi-signature software update process to help better secure data acquisition devices from malicious actions by using standard cryptosystems such as TLS. A prototype system build on Linux and off-the-shelf hardware has shown successful update and attack prevention with our customized multi-party update software.

Newberg, Benjamin↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Discontinuous Galerkin Dynamical Core in HOMME

Atmospheric numerical modeling has been going through radical changes over the past decade. One major reason for this trend is due to the recent paradigm change in scientific computing , triggered by the arrival of petascale computing resources with core counts in the tens of thousands to hundreds of thousands range. Modern atmospheric modelers must adapt grid systems and numerical algorithms to facilitate an unprecedented levels of scalability on these modern highly parallel computer architectures. The numerical algorithms which can address these challenges should have the local properties such as high on-processor floating-point operation count to bytes moved and minimum parallel communication overhead.

17 WIND ENERGY↗

Grid Architecture Mapping to Understand Transformation (GAMUT): Concept Definition

The electric power system is undergoing significant transformation driven by changes in the generation mix, increasing reliance on information and communication technologies, evolving customer expectations, and a dynamic cyber-physical environment. To address these challenges, substantial investments will be made over the next decade to create a flexible, affordable, secure, reliable, and resilient electric system. In response, the U.S. Department of Energy's Office of Electricity is developing knowledge management tools aimed at systematically documenting technology pilots and demonstration projects. This initiative seeks to improve understanding of operating contexts, planning steps, and integration requirements for innovative grid technologies. The Department of Energy project leverages Grid Architecture principles to collect and organize insights into the interdependencies, requirements, and capabilities of various grid solutions. By employing a systematic approach, the project aims to perform a feasibility study for the development of a software tool that will support stakeholders, including regulators, transmission and distribution system operators, distributed energy resources aggregators, and technology providers. By offering a systematic, software-based framework to document technologies, understand their benefits and impacts, and inform deployment strategies, the proposed Grid Architecture Mapping to Understand Transformation (GAMUT) Tool is intended to reduce costs, enhance decision-making, and facilitate scaling and effective deployment of new technologies. The feasibility study will evaluate the technical and financial viability of the GAMUT Tool, identifying stakeholder needs and assessing risks and mitigation strategies. Ultimately, the GAMUT team aims to develop an initial minimal viable product, followed by staged improvements, to aid in the modernization of the electric grid, contributing to a more sustainable and resilient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Five Indisputable Facts on Modern Power Systems

This presentation overviews five indisputable facts about modern power systems: Fact one: The grid can handle more renewable generation than previously thought. Fact two: Geographic and resource diversity provide additional reliability to the system. Fact three: Wind and solar forecasting provide significant value. Fact four: Our electric power markets were not originally designed for variable renewables -- but they could be adapted. Fact five: Modern power electronics are creating new sources of essential reliability services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 5: Integration of Renewable Energy Technologies in Buildings and Cities

Sustainable Energy Technologies, such as the solar, wind, and waterpower systems described in other chapters of this book, need to be integrated into our energy systems to expand access to energy while avoiding harmful effects on the environment. The existing utility system or 'grid' is a network that consists of components for generation, transmission, distribution, and control of electric power from producers (also called 'resources') to consumers (also called 'loads' or 'demand'). Public safety necessitates that the grid be reliable, and public policy requires that grid power be affordable and broadly accessible. Much of the existing power grid was constructed before the advent of modern information technology for controls and automation. The existing grid is facing new challenges related to increases in power demand, complexity in managing more diverse and distributed resources, power quality issues introduced by 'non-linear' loads (that have parasitic inductance and capacitance like LED lights or computers), physical and cybersecurity threats, and challenges to the existing economic model of costs and revenues. Increases in power demand include not only growth in population and per-capita electricity use, but also call for electricity to meet the need for heating and transportation as well. Electric vehicles are a rapidly growing example of this electrification of previously fossil-fueled uses. [Your author's Chevrolet Volt vehicle uses about the same amount of electricity as his house, around 300 kWh/month. Fortunately, both are served with solar photovoltaics (PVs)]. Therefore, there is an immediate need for improvement toward a reliable, self-regulating, efficient, and economical grid system that will allow the integration of renewable distributed power generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power Distribution Designing For Resilience Application

The number of power outages have been on the rise as extreme weather patterns have been occurring more frequently due to climate change. These outages have an economic impact in the billions of dollar. The modernization of the power grid and adoption of high penetration of distributed generation such as wind and solar have the potential to reduce the number and length of time of these power outages. However, planners and operators need a way to value the resilience the distributed assets provide to the grid. PowDDeR is a tool that allows them to evaluate the resilience each asset provides as well as how they provide resilience over the connected network.

Phillips, TylerB↗

Renewable Firming EnergyFarm Final Report

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided the U.S. Department of Energy (DOE) with funds to modernize the electric power grid. One program under this initiative is the Smart Grid Demonstration program (SGDP). The SGDP mandate is to demonstrate how a suite of existing and emerging smart grid technologies can be innovatively applied and integrated to prove technical, operational, and business-model feasibility. Primus Power is a provider of low cost, long life and long duration energy storage systems. The Company’s flow batteries are shipping to US and international microgrid, utility, military, commercial and industrial customers. Primus Power’s EnergyPod® is a modular battery system for grid scale applications available in configurations ranging from 25 kW to more than 25 MW. The EnergyPod provides nameplate power for 5 hours. This long duration unlocks economic benefits on both sides of the electric meter. It allows commercial and industrial customers to shift low cost electricity purchased at night to offset afternoon electrical peaks to reduce utility demand charges. It also allows utilities to economically reduce power peaks and defer costly upgrades to distribution infrastructure. An EnergyPod contains one or more EnergyCells-a highly engineered flow battery core made from low cost, readily available materials. An EnergyCell includes a membrane-free stack of titanium electrodes located above a novel liquid electrolyte management system. This patented design enables reliable, low maintenance operation for decades. It is safe and robust, featuring non-flammable aqueous electrolyte, sophisticated fault detection and built-in secondary containment. Unlike Li Ion batteries, the EnergyCell is not susceptible to thermal runaway. This cooperative agreement project was started in Feb 2010. The objectives of the project are: 1. Trigger rapid adoption of grid storage systems in the US by demonstrating a low cost, robust and flexible EnergyFarm®. 2. Accelerate adoption of renewable energy and enhance grid stability by firming the output of wind & solar farms. 3. Demonstrate improved grid asset utilization by storing energy during off-peak periods for dispatch during local load peaks. 4. Establish an advanced battery manufacturing industry in the U.S. 5. Reduce CO2 emissions from utilities. This report summarizes the key milestones, data, results and lessons learned from the project. The desired goals and benefits of the cooperative agreement with the DOE have all been achieved. The project has contributed to reducing power costs, accelerating adoption of renewable energy resources, reducing greenhouse gas emissions and establishing advanced battery manufacturing in the U.S. The Recovery Act funds provided thru the DOE have been leveraged multiple times by additional private equity investment. Primus Power continues to ship low cost, long life and long duration EnergyPod® flow battery systems to utilities, commercial/industrial, microgrid and data center customers. After the conclusion of this project, Primus Power has modified the EnergyPod® design to optimize around energy performance. Primus Power has moved to a prefabricated enclosure instead of multiple EnergyCells in a container. This lowers capital and maintenance costs and can optimize site design. Utilities are starting to adopt energy storage for a variety of functions. The market will grow as the technology is proven and profitable applications expand.

25 ENERGY STORAGE↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - runZero Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator™ (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - Asimily Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator (TM) (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

Solar and Energy Efficiency: Resources to Support Local Initiatives for Low-to-Moderate Income Communities

This SolSmart webinar serves as an educational resource for local governments interested in better understanding market barriers and expanding solar and energy efficiency deployment in low to moderate income (LMI) communities. Viewers will be able to explore and visualize data developed by the National Renewable Energy Lab (NREL) focused on how rooftop solar on LMI housing represents an opportunity to help modernize the U.S electric grid and advance energy affordability in LMI communities. NREL and the American Council on an Energy Efficient Economy (ACEEE) also discuss financing options and incentives for solar development and energy efficiency in LMI communities.

14 SOLAR ENERGY↗

South Asia Group for Energy - Sri Lanka

Sri Lanka set a target of generating 70% of its electricity from renewable energy sources by 2030. This goal includes the addition of 5.8 GW of renewable power capacity, comprising hydropower, solar, wind, and biomass, between 2023 and 2030, with an interim target of adding 2.5 GW of renewable capacity by 2026. To accomplish this, Sri Lanka's power grid needs significant transformation and modernization to handle the integration of variable renewable energy sources effectively. The South Asia Group for Energy (SAGE) is helping Sri Lanka's grid operator, the Ceylon Electricity Board (CEB), understand the gaps for operating the grid with higher renewable share and identifying technology and research requirements to establish a variable renewable energy control center.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Grid‐responsive smart manufacturing: A perspective for an interconnected energy future in the industrial sector

Abstract With the growing amount of renewable energy sources, the grid has become responsible for accounting for intermittency and the flexibility needed to utilize dynamic sources. Expensive peaking plants and energy storage systems have been proposed as ways to mitigate those problems. There is a large group of energy consumers that can respond to grid conditions. Historically, these consumers have been residential and commercial users, but with modern innovations and practices, industrial consumers have the potential to become a major player in this space. Grid‐responsive smart manufacturing can be used to utilize modern tools in manufacturing innovation as enablers for grid response. These modern tools already exist but are not widely used for industrial grid‐side energy management. This article defines grid‐responsive smart manufacturing, identifies five major barriers to its widespread implementation, and portrays the path to getting industrial users to be key players in grid stability and flexibility.

Billings, Blake W.↗