Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fusion diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Augmenting machine learning of Grad–Shafranov equilibrium reconstruction with Green's functions

This work presents a method for predicting plasma equilibria in tokamak fusion experiments and reactors. The approach involves representing the plasma current as a linear combination of basis functions using principal component analysis of plasma toroidal current densities (J t ) from the EFIT-AI equilibrium database. Then utilizing EFIT's Green's function tables, basis functions are created for the poloidal flux (ψ) and diagnostics generated from the toroidal current (J t ). Similar to the idea of a physics-informed neural network (NN), this physically enforces consistency between ψ, J t , and the synthetic diagnostics. First, the predictive capability of a least squares technique to minimize the error on the synthetic diagnostics is employed. The results show that the method achieves high accuracy in predicting ψ and moderate accuracy in predicting J t with median R 2 = 0.9993 and R 2 = 0.978, respectively. A comprehensive NN using a network architecture search is also employed to predict the coefficients of the basis functions. The NN demonstrates significantly better performance compared to the least squares method with median R 2 = 0.9997 and 0.9916 for J t and ψ, respectively. The robustness of the method is evaluated by handling missing or incorrect data through the least squares filling of missing data, which shows that the NN prediction remains strong even with a reduced number of diagnostics. Additionally, the method is tested on plasmas outside of the training range showing reasonable results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal structure of blobs in NSTX

The time dependence of the blob pulse shape and the waiting time between blobs was found using data from the gas puff imaging diagnostic in NSTX. The database used was of 103 shots from 2010 as described in a previous paper (Zweben et al., Phys. Plasmas 29, 012505 (2022).]. The blob pulse shape was well fit by an exponential rise and fall where the average rise time was τ r = 9.0 ± 2.7 μs and the average fall time was τ f = 16.6 ± 5.8 μs. The waiting times between blob pulses above a threshold of three times the mean had a broad distribution with an average of τ w = 1.2 ± 0.85 ms over the database. The blob intermittency parameter γ b = τ d /τ w , where the blob pulse duration was τ d = τ r + τ f , ranged from γ b ~1% to 5% for shots in this database and increased almost linearly with the blob fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Regimes During Plasma Catalytic Ammonia Synthesis

Herein, we demonstrate that the performance of mesoporous silica SBA-15 and SBA-15-Ag during plasma ammonia synthesis depends on the plasma conditions. At high power, the mesoporous silica SBA-15 without Ag produces the largest amount of ammonia, but the addition of Ag provides a minor benefit at lower powers. Plasma conditions were analyzed through optical emission spectroscopy using N 2 , N 2 + , and NH molecular bands and H α line. Stark broadening of H α line was used to find electron density, and N 2 molecular bands were used to assess N 2 vibrational excitation, important for plasma nitrogen decomposition. At similar input conditions, reactors with SBA-15 have higher electron density and higher N 2 vibrational temperature. Consistent with higher electron density, SBA-15 reactors have stronger N 2 + emission intensity relative to the neutral N 2 . The addition of Ag results in higher N 2 rotational temperature, possibly due to localized heating. From the materials point of view, SBA-15 is a more robust catalyst with good surface area retention after plasma exposure due to the lack of local heating generated when a metal is in the structure. Furthermore, we identify two possible regimes during ammonia synthesis, a metal and a surface-plasma driven. At lower plasma densities, the addition of metal is beneficial, while at higher power and plasma density, the best performance is achieved without the aid of a metal catalyst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-domain modelling and thermometry of the CH 4 v 1 Q-branch using hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

Here, we present time-domain measurements and modelling of the CH 4 v 1 vibrational Q-branch, as well as simultaneous temperature acquisition from the CH 4 and N 2 vibrational Q-branches using broadband hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Accurate measurements with fs/ps CARS require knowledge of the time-domain response of the probed molecule at different temperatures and pressures. In this work, a fs/ps CARS model was developed for theCH 4 v 1 Q-branch and validated using time-resolved probe delay scans at pressures between 70 and 600 Torr and temperatures between 295 and 1000 K. A simplified modified exponential energy gap model was used to determine the linewidths of the Raman transitions within the Q-branch. Total Q-branch linewidths for the entire explored parameter space were also determined from the probe delay scans. This enabled quantitative measurements of CH 4 with fs/ps CARS as well as the temperature through the hot bands of the CH 4 v 1 Q-branch. With a broadband fs laser pulse in a two-beam phase matching scheme, the N 2 Q-branch and CH 4 v 1 Q-branch were simultaneously measured in a heated cell, and the temperatures from each molecule's spectra was evaluated. Here, the fitted temperatures corresponded well with differences ranging from 4 to 17%. It was also shown that exchanging 90% of CH 4 for N 2 or Ar at 295 K and 500 Torr did not significantly impact the normalized time-domain signal prior to a 100 picosecond probe delay. Spatially resolved one-dimensional (1-D) thermometry using the CH 4 Q-branch was also demonstrated with an imaged spatial resolution of 40 µm. With the developed model, 1-D quantitative measurements of CH 4 concentration and temperature can be measured with time resolution of tens of picoseconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning-aided line intensity ratio technique applied to deuterium plasmas

It has been demonstrated that the electron density, n e , and temperature, T e , are successfully evaluated from He I line intensity ratios coupled with machine learning (ML). In this paper, the ML-aided line intensity ratio technique is applied to deuterium (D) plasmas with 0.031 < n e (10 18 m –3 ) < 0.67 and 2.3 < T e (eV) < 5.1 in the PISCES-A linear plasma device. Two line intensity ratios, D α /D γ and D α /D β , are used to develop a predictive model for n e and T e separately. Reasonable agreement of both ne and Te with those from single Langmuir probe measurements is obtained at n e > 0.1 × 10 18 m –3 . Addition of the D 2 /D α intensity ratio, where the D 2 band emission intensity is integrated in a wavelength range of λ ~ 557.4–643.0 nm, is found to improve the prediction of, in particular, n e , and T e . It is also confirmed that the technique works for D plasmas with 0.067 < n e (10 18 m –3 ) < 6.1 and 0.8 < T e (eV) < 15 in another linear plasma device, PISCES-RF. The two training datasets from PISCES-A and PISCES-RF are combined, and unified predictive models for n e and T e give reasonable agreement with probe measurements in both devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Facing Component Characterization and Correlation With Plasma Conditions in Lithium Tokamak Experiment-β

Lithium coatings in the Lithium Tokamak eXperiment (LTX) led to flat temperature profiles. The flat temperature profiles were observed along with a hot, low density edge, implying a broad, collisionless scrape-off layer (SOL). Additionally, in vacuo X-ray photoelectron spectroscopy (XPS) measurements established that lithium coatings evaporatively deposited onto high-Z plasma facing components (PFCs) became oxidized while retaining the ability to achieve good plasma performance long after lithium was applied to the PFCs. Longstanding theory predicted flat temperature profiles with low recycling walls, which was presumed to be due to hydrogen binding with elemental lithium to form lithium hydride. The presence of oxidized lithium, however, raised questions regarding the exact mechanism of hydrogen retention in LTX. To investigate these questions, the upgraded facility LTX- β includes a new sample exposure probe (SEP) for more detailed in vacuo analysis of PFC samples. The SEP is equipped with a vacuum suitcase capable of transporting samples representative of the LTX- β outer midplane PFCs to a stand-alone XPS system while maintaining pressures lower than the LTX- β base vacuum to limit the contamination between sample exposure and analysis. The low-energy resolution XPS system used in past experiments could only enable the determination of elemental percentages on the PFC sample surfaces. Because the new XPS system has higher energy resolution, it is more direct to assign chemical compounds to the measured binding energies. This capability has been confirmed by comparing XPS data from PFC test samples with measurements using a commercial high-resolution XPS system. Quartz crystal microbalances (QCMs) were used to quantify the thickness of the deposited lithium on the LTX- β PFCs. This article describes the application of the SEP to characterize the PFC surfaces using XPS and their relationship to plasma conditions.

Maan, Anurag↗

Comparison of excitation and kinetic temperatures in a laser-produced plasma using absorption spectroscopy

High-resolution tunable laser absorption spectroscopy is used to measure time-resolved absorption spectra for six neutral uranium transitions in a laser-produced plasma. Here analysis of the spectra shows that kinetic temperatures are similar for all six transitions, but excitation temperatures are higher than kinetic temperatures from 10–100 μs, indicating departures from local thermodynamic equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data for reproducing the figures of the paper Multimodal Super-Resolution: Discovering hidden physics and its application to fusion plasmas

This deposit contains the raw data for reproducing research results of the paper Multimodal Super-Resolution: Discovering hidden physics and its application to fusion plasmas. The main contribution of this work is to utilize machine learning techniques to reconstruct and enhance the resolution of a diagnostic measurement from other available diagnostics in a system. The proposed techniques is called Diag2Diag.

diag2diag↗

Wire, hybrid, and laser-cut X-pinches as Talbot–Lau backlighters for electron density diagnostics

Talbot–Lau x-ray deflectometry (TXD) enables refraction-based imaging for high-energy-density physics experiments, and thus, it has been studied and developed with the goal of diagnosing plasmas relevant to inertial confinement and magnetic liner inertial fusion. X-pinches, known for reliably generating fast (~1 ns), small (~1 µm) x-ray sources, were driven on the compact current driver generator for ablation structure and implosion studies (~200 kA, 150 ns) as a potential backlighter source for TXD. Considering that different X-pinch configurations have characteristic advantages and drawbacks as x-ray generating loads, three distinct copper X-pinch configurations were studied: the wire X-pinch, the hybrid X-pinch, and the laser-cut X-pinch. Furthermore, the Cu K-shell emission from each configuration was characterized and analyzed regarding the specific backlighter requirements for an 8 keV TXD system: spatial and temporal resolution, number of sources, time of emission, spectrum, and reproducibility. Recommendations for future experimental improvements and applications are presented. The electron density of static objects was retrieved from Moiré images obtained through TXD. This allowed to calculate the mass density of static samples within 4% of the expected value for laser-cut X-pinches, which were found to be the optimal X-pinch configuration for TXD due to their high reproducibility, small source size (≤5 µm), short duration (~1 ns), and up to 106 W peak power near 8 keV photon energy. Plasma loads were imaged through TXD for the first-time using laser-cut X-pinch backlighting. Experimental images were compared with simulations from the x-ray wave-front propagation code, demonstrating that TXD can be a powerful x-ray refraction-based diagnostic for dense Z-pinch loads. Future plans for Talbot–Lau interferometry diagnostics in the pulsed-power environment are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Birefringence in thermally anisotropic relativistic plasmas and its impact on laser–plasma interactions

One of the paradigm-shifting phenomena triggered in laser–plasma interactions at relativistic intensities is the so-called relativistic transparency. As the electrons become heated by the laser to relativistic energies, the plasma becomes transparent to the laser light even though the plasma density is sufficiently high to reflect the laser pulse in the non-relativistic case. This paper highlights the impact that relativistic transparency can have on laser-matter interactions by focusing on a collective phenomenon that is associated with the onset of relativistic transparency: plasma birefringence in thermally anisotropic relativistic plasmas. Here, the optical properties of such a system become dependent on the polarization of light, and this can serve as the basis for plasma-based optical devices or novel diagnostic capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomographic imaging of atmospheric pressure plasma on complex surfaces

Many plasma types and behaviors such as streamer, arcs, cathode spots, anode spots, ionization waves, and magnetic field interactions create non-symmetric, fully 3D plasma structures. The plasma distribution in 3D space is heavily influenced by complex surfaces and the coupling interactions between plasma properties and the interfacing material properties. For example, ionization waves propagate in directions where ionization rates are highest, leading to complex configurations that are not fully understood or well characterized. Recent advances in laser diagnostics and models have been able to investigate well-controlled idealized plasmas in 2D fashion, but the complex structure in actual plasmas requires a technique than can provide a more complete 3D picture. However, 3D plasma diagnostics do not currently exist. To address this limitation, this activity will leverage available equipment to build a new tomographic optical imaging capability and advance the state-of-the-art in plasma diagnostics to investigate 3D phenomena on complex surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of RF-induced E×B flows in the mitigation of scrape-off-layer convective transport during ion cyclotron resonance heating

Abstract While multiple experiments have reported a decrease in intermittent fluctuations in the far Scrape-Off-Layer (SOL) during ion cyclotron resonance heating (Antar et al 2010 Phys. Rev. Lett. 105 165001, Li et al 2022 Nucl. Eng. Technol. 54 207–19, Antar et al 2012 Nucl. Fusion 52 103005), the physical mechanism behind this observation has not been fully established yet. In this work, we demonstrate, for the first time, a direct correlation between the amplitude of RF-induced E×B flows and turbulence suppression in the far SOL. Using the Gas Puff Imaging (GPI) diagnostic on Alcator C-Mod, we show again that Ion Cyclotron Range of Frequencies can significantly alter the flow in the SOL and introduce a shear layer in regions magnetically connected close to the antenna (Cziegler et al 2012 Plasma Phys. Control. Fusion 54 105019). With the 4-strap field-aligned antenna operated in dipole phasing, the ratio of the power coupled by the central two straps to the power coupled by the outer two straps was varied. The resulting RF-induced radial electric field magnitude thus varied, and we show that the impact on the far SOL turbulence correlates with the modified E×B velocity. We then apply a newly-developed blob tracking algorithm (Han et al 2022 Sci. Rep. 12 18142) to higher-resolution GPI videos in order to directly observe the process of blob shearing by RF-induced E×B flows. We show that the radially sheared poloidal flows act as a transport barrier by stretching, stopping, and destroying filaments, which is consistent with the observed difference in turbulence statistics.

Diab, R. (ORCID:0000000342065868)↗

Outlier classification using autoencoders: application for fluctuation driven flows in fusion plasmas

Understanding the statistics of fluctuation driven flows in the boundary layer of magnetically confined plasmas is desired to accurately model the lifetime of the vacuum vessel components. Mirror Langmuir probes (MLPs) are a novel diagnostic that uniquely allow us to sample the plasma parameters on a time scale shorter than the characteristic time scale of their fluctuations. Sudden large-amplitude fluctuations in the plasma degrade the precision and accuracy of the plasma parameters reported by MLPs for cases in which the probe bias range is of insufficient amplitude. While some data samples can readily be classified as valid and invalid, we find that such a classification may be ambiguous for up to 40% of data sampled for the plasma parameters and bias voltages considered in this study. In this contribution, we employ an autoencoder (AE) to learn a low-dimensional representation of valid data samples. By definition, the coordinates in this space are the features that mostly characterize valid data. Ambiguous data samples are classified in this space using standard classifiers for vectorial data. In this way, we avoid defining complicated threshold rules to identify outliers, which require strong assumptions and introduce biases in the analysis. By removing the outliers that are identified in the latent low-dimensional space of the AE, we find that the average conductive and convective radial heat fluxes are between approximately 5% and 15% lower as when removing outliers identified by threshold values. For contributions to the radial heat flux due to triple correlations, the difference is up to 40%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗